A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor

Similar documents
Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

The Portable Gas Analyzer Based on the Spectrum

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

u = Open Access Reliability Analysis and Optimization of the Ship Ballast Water System Tang Ming 1, Zhu Fa-xin 2,* and Li Yu-le 2 " ) x # m," > 0

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Online DGA-monitoring of power transformers

2. Introduction of nitrogen injection displacement for fire extinguishment

Laser Gas Analyzer LG2000. The Laser Technologies

General Information. Department of Physics, Kansas State University, 116 Cardwell Hall Manhattan, KS 66506, USA. Education

Online gas monitoring by using Raman spectroscopy

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

FTIR Users Group Meeting FTIR development

Measuring Sound Speed in Gas Mixtures Using a Photoacoustic Generator

A new method for noninvasive venous blood oxygen detection

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

TGA100A Trace Gas Analyzer Overview

DESIGN OF REMOTE CONTROL SYSTEM FOR FAR-INFRARED LASER INTERFEROMETER

Vibration Analysis and Test of Backup Roll in Temper Mill

FOURIER TRANSFORM INFRARED SPECTROSCOPY

Level MEASUREMENT 1/2016

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Basketball field goal percentage prediction model research and application based on BP neural network

Module 5 : Pulse propagation through third order nonlinear optical medium. Lecture 38 : Long distance soliton transmission system.

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

Mid-IR Lasers Market Review and Forecast 2010

The FLUX-METER: implementation of a portable integrated instrumentation for the measurement of CO 2 and CH 4 diffuse flux from landfill soil cover.

Thermo Scientific Model 146i Principle of Operation

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Study on the shape parameters of bulbous bow of. tuna longline fishing vessel

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface

Implementation of Height Measurement System Based on Pressure Sensor BMP085

Computer Aided Drafting, Design and Manufacturing Volume 26, Number 2, June 2016, Page 53. The design of exoskeleton lower limbs rehabilitation robot

Experimental Research on Oxygen-enriched Air Supply System for Gasoline Engine

A study of advection of short wind waves by long waves from surface slope images

Introductions for a Multi-function Portable SF 6 Leaking Alarm Testing Device Based on a Two-level Configure Gas Technology

FLUORESCENCE DETERMINATION OF OXYGEN

Proceedings of Meetings on Acoustics

sensors ISSN

EasyLine Continuous Gas Analyzers. So smart, they re simple

67. Sectional normalization and recognization on the PV-Diagram of reciprocating compressor

Instruments for Measurement of Dissolved CO 2 and O 2 in Beverages

Statistical Process Control Lab

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1


Journal of Chemical and Pharmaceutical Research, 2014, 6(3): Research Article

ANALYSIS OF THE POSITIVE FORCES EXHIBITING ON THE MOORING LINE OF COMPOSITE-TYPE SEA CAGE

The analysis of complex multicomponent

Critical Gust Pressures on Tall Building Frames-Review of Codal Provisions

LFE OEM TCD - Thermal Conductivity Detector

Real-time PCB Gas Monitoring System (MOHMS-21GP)

Numerical simulation of three-dimensional flow field in three-line rollers and four-line rollers compact spinning systems using finite element method

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

A Fault Diagnosis Monitoring System of Reciprocating Pump

Optical-Polymer and Polymer-Clad- Silica-Fiber Data Buses for Vehicles and Airplanes Principles, Limits and New Trends

Modeling Diffusion Rates of a Gas in an Enclosed Space

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

S on equipment and pipelines along with the constant threat to personnel safety justify major investment in H 2

EVALUATION OF ENVISAT ASAR WAVE MODE RETRIEVAL ALGORITHMS FOR SEA-STATE FORECASTING AND WAVE CLIMATE ASSESSMENT

Study on Fire Plume in Large Spaces Using Ground Heating

Research on ESC Hydraulic Control Unit Property and Pressure Estimation

Optical measurement in carbon nanotubes formation by pulsed laser ablation

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Minimal influence of wind and tidal height on underwater noise in Haro Strait

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

RESEARCH OF BLOCKAGE SEGMENT DETECTION IN WATER SUPPLY PIPELINE BASED ON FLUID TRANSIENT ANALYSIS ABSTRACT

Predictive Control of Dissolved Oxygen Concentration in Cynoglossus Semilaevis Industrial Aquaculture

Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study

THE APPLICATION OF BASKETBALL COACH S ASSISTANT DECISION SUPPORT SYSTEM

Influence of Ventilation Tube Rupture from Fires on Gas Distribution in Tunnel

Numerical Simulation of the Basketball Flight Trajectory based on FLUENT Fluid Solid Coupling Mechanics Yanhong Pan

HiBarSens: Measurement of barrier properties by tunable diode laser absorption spectroscopy (TDLAS)

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

SAF WATER LEAK DETECTION BY THE MEASUREMENT OF GASEOUS WATER VAPOUR

THE PRIMARY SOURCES OF SHIP NOISE OBSERVED ON THE BOTTOM OF SEA KAROL LISTEWNIK

Three-Dimensional Plasmonic Hydrogel Architecture: Facile Synthesis and Its Macro Scale Effective Space

RESPIRATORY PHYSIOLOGY, PHYSICS AND

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

The instrument should have a mass range from 2 to 2000 m/z or better Interface

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Chapter 7. SCIIB Pressure Sensor Performance Evaluations: Experiments, Results and Discussions

INDEPENDENT TESTING OF SPARKLIKE LASER NON-DESTRUCTIVE INSULATING GLASS GAS FILL ANALYZER

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Experimental research on instability fault of high-speed aerostatic bearing-rotor system

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

EXPERIMENTAL RESEARCH ON COEFFICIENT OF WAVE TRANSMISSION THROUGH IMMERSED VERTICAL BARRIER OF OPEN-TYPE BREAKWATER

The Helium Leak Detector

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Transcription:

PHOTONIC SENSORS / Vol. 5, No. 1, 215: 67 71 A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor Yubin WEI 1,2, Jun CHANG 1*, Jie LIAN 1, and Tongyu LIU 2 1 School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Jinan, 251, China 2 Laser Research Institute of Shandong Sciences Academy, Jinan, 2514, China * Corresponding author: Jun CHANG E-mail: changjun@sdu.edu.cn Abstract: Spontaneous combustion of the coal mine goaf is one of the main disasters in the coal mine. The detection technology based on symbolic gas is the main means to realize the spontaneous combustion prediction of the coal mine goaf, and ethylene gas is an important symbol gas of spontaneous combustion in the coal accelerated oxidation stage. In order to overcome the problem of current coal ethylene detection, the paper presents a mine optical fiber multi-point ethylene concentration sensor based on the tunable diode laser absorption spectroscopy. Based on the experiments and analysis of the near-infrared spectrum of ethylene, the system employed the 1.62 μm (DFB) wavelength fiber coupled distributed feedback laser as the light source. By using the wavelength scanning technique and developing a stable fiber coupled Herriot type long path gas absorption cell, a ppm-level high sensitivity detecting system for the concentration of ethylene gas was realized, which could meet the needs of coal mine fire prevention goaf prediction. Keywords: Spontaneous combustion, signature gas, ethylene, tunable diode laser absorption spectroscopy (TDLAS), distributed feedback laser (DFB), Herriott cell Citation: Yubin WEI, Jun CHANG, Jie LIAN, and Tongyu LIU, A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor, Photonic Sensors, 215, 5(1): 67 71. 1. Introduction Mine fire is one of the main disasters in coal mines, and 56% coal mines in China had spontaneous combustion disasters, among them, the goaf spontaneous combustion possessed a great proportion. According to statistics, China s state-owned key coal mines with spontaneous combustion dangerous mines accounted for about 51.3% of the total. Mine fire may influence the safety in production, even burning coal resources and materials equipment, causing casualties, and even leading to gas or coal dust explosion. Therefore, goaf coal spontaneous combustion prediction and early warning and positioning have the important significance for reducing the loss of life and property. To solve this problem of the exploitation of coal spontaneous combustion tendency, researchers have established a series of prediction technologies. The signature gases analysis method is used mainly to determine the process of coal spontaneous combustion or the development trend of coal spontaneous combustion according to the gas production of CO, C 2 H 2, C 2 H 4, and alkane. The ethylene gas is one of the important signature gases generated in the process of the coal accelerated Received: 25 February 214 / Revised version: 12 May 214 The Author(s) 214. This article is published with open access at Springerlink.com DOI: 1.17/s1332-14-26-z Article type: Regular

68 Photonic Sensors oxidation stage, which has the important significance for the spontaneous combustion prediction. At present, generally the tube pipe monitoring analysis system based on the gas chromatography is adopted, which has the disadvantages of equipment complex, long sampling and analysis cycle, long distance sample pipeline leak easily leading to inaccurate measurement, and the urgent need to improve the performance [1, 2]. TDLAS is a high-sensitivity, real-time, and dynamic trace gas detection technique. Owing to the high monochromaticity of the laser diode, the absorption spectra of gases can be detected using an isolated absorption line of each gas molecule. In this way, different molecules can be identified while avoiding interference from other spectra. According to this technique, the near-infrared waveband is matched with the low-loss window of an optical fiber, and by using such optical fibers, the remote transport of a light beam is realized [3 6]. Moreover, the remote, on-line, and real-time detection of the gas concentration is achieved by combining TDLAS and optical fiber sensing techniques. Owing to the whole system being based on an optical fiber, the sensor is able to enter the goaf to carry out field tests, instead of pumping out gases, thus avoiding measurement errors during pipe sampling [9]. To overcome the problems with current ethylene detection methods used in the coal mine, a mine-used, multi-point optical fiber-based sensor for detecting the ethylene gas concentration was presented based on the TDLAS approach. On the basis of experiments and analysis of ethylene using the near-infrared spectroscopy, the fiber coupling distributed feedback laser (DFB) in the near-infrared waveband at a wavelength of 1.62 µm was chosen as the light source. Furthermore, a wavelength scanning technique was used, and a long optical path length based gas cell was developed with a stable and reliable fiber coupling using the Herriot principle. Using this gas cell, the ethylene concentration could be detected at ppm-level high sensitivity. It provides a novel detection method for the forecasting of spontaneous combustion in the coal goaf. 2. Test principle In different conditions, the wavelength, intensity, and polarization, etc of molecules absorption or emission spectra and the material structure characteristic have their intrinsic relationships. Different gas molecule structures correspond to different absorption spectra; the same gas with different concentrations in the same absorption peak position has different absorption intensities, so by detecting the gas absorption intensity on the specific wavelength light, the composition and concentration of gas can be determined. According to the Lambert-Beer law, when a beam of parallel light with an intensity I (λ) passes through a gas cell filled with the gas under test and provided that the spectrum of the light source encompasses one or more of the absorption lines of the gas, the relationship among the transmitted light intensity I(λ), incident intensity I (λ), and the gas concentration C is [7, 8] I( ) I( )exp[ ( ) CL] I( )exp[ PS( T ) ( ) CL] (1) where ( ) is the absorption coefficient of the gas; L [cm] is the length of the gas absorbing light; function, which represents the shape of the absorption spectral lines which is associated with the 2 1 ST ( )[cm atm ] is the intensity of the temperature, total pressure, and proportional characteristic spectral line of the gas, which represents the absorption intensity of the spectral lines which is related to temperature; P [atm] is the total pressure of the gas; C is the volume concentration of the gas; ( )[cm] is a line-shape composition of the gas. The most commonly used line-shape functions are those: Lorentz, Gauss, and Voigt functions. After taking logarithm of (1), the integration over the whole frequency domain is

Yubin WEI et al.: A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor 69 I PCS( T ) L ln( ) d A. (2) I The gas concentration is therefore calculated from I ln( ) d I A. (3) C PS( T ) L PS( T ) L Given that parameters such as the pressure, line intensity, and length of the gas absorbing light path are known, the integral value of ln( I I ) in the frequency domain is substituted into (3), and the final gas concentration can then be obtained [1]. 3. Absorption lines of ethylene gas in the near-infrared region Under normal detection conditions, the moisture and carbon dioxide contents in air are the most important sources of interference with gas measurement. To avoid cross-interference from other gases, the absorption lines are required to be carefully selected, and they can be directly obtained from the high-resolution transmission molecular absorption database (HITRAN), as shown in Fig. 1 where the intrinsic absorption peak of ethylene lies near 3.3 µm. However, there are no absorption data for ethylene at 1.7 µm in the HITRAN database. Absorption line intensity (cm 1 molecule cm 2 ) 1.2E-2 1.E-2 8.E-21 6.E-21 4.E-21 2.E-21.E+ 16 18 2 22 24 26 28 3 32 34 Wavelength (nm) Absorption line intensity Fig. 1 Absorption lines of ethylene in the near-infrared region (1.5 µm to 3.5 µm). The authors found the absorption lines of ethylene at around 1.7 µm from the PNNL database (Fig. 2). However, an accurate and complete absorption spectrum for ethylene remains to be found. To obtain accurate absorption lines, the standard ethylene gas was tested under broadband light at 165 nm (range: 155 nm to 17 nm), at an ethylene gas concentration of 2 %, using a gas cell with an optical path of 1 cm across its absorption cavity, and with the absorption spectrum data obtained by an AQ637 spectrometer. The gas cell was firstly cleaned using the pure nitrogen gas, and then the transmittance signal in the clean gas cell was tested using the light source. Afterwards, the ethylene gas was injected into the gas cell to detect the absorbed transmittance signal. After normalization, the absorption lines of the ethylene gas were acquired. As shown in Fig. 3, ethylene presented a strong absorption at 1626 nm, and there were strong absorption bands at approximately 162 nm and 163 nm. They could be used as signature absorption lines. In the proposed system, the absorption line at 162 nm was chosen as the determining wavelength to avoid cross-absorption of interference gases, because of its preferable line-type and high absorption intensity. Above all, this wavelength lay at the edge of the L-waveband in optical communications, and a laser device able to operate at this wavelength was easily obtained and cheap. Abs. intensity 1 21 /cm 2 /molecule 6 4 2 C 2H 4 1.62 1.64 1.66 1.68 1.7 1.72 Wavelength (microns) Fig. 2 Absorption lines of ethylene in the near-infrared region (PNNL database). Absorption ratio (a.u).18.16.14.12.1.8.6.4.2 162 nm abs. line Abs. ratio. 161 162 163 164 165 Wavelength (nm) Fig. 3 Absorption lines of ethylene in the infrared region.

7 Photonic Sensors 4. Optical fiber ethylene sensor system: experimental work The structure of the proposed optical fiber-based ethylene monitoring system is shown in Fig. 4. The DFB laser device was driven by a current-driving, and its working temperature was controlled by a temperature control. Then, the laser device output a continuous spectrum with a central wavelength of 162 nm to realize wavelength modulation. The gas cells were 9.3 m in length. An InGaAs photoelectric detector was employed to encompass the range from 6 nm to 17 nm. Three PIN detectors PD1, PD2, and PD3 were used to detect the output intensity of the light after passing through the gas cell, the light intensity of the output signal of the light source after passing through two couplers, and the output intensity of the light after passing through the reference gas cell, respectively. The reference gas cell was filled with C 2 H 4 gas at 1% concentration to find the position of the peak absorption. Afterwards, three detection signals were collected using a data acquisition unit and then normalized. The normalized signal was subjected to a least square fit against the standard signal to calculate the concentration of C 2 H 4 gas [11]. Bias current Temperature control Saw tooth wave 1*2 split Laser 5:95 coupler Light source PD Computer Fiber Data acquisition unit Sensor gas cell 1 Sensor gas cell 2 Sensor gas cell 3 Reference gas cell Fig. 4 Structure of the optical fiber ethylene monitoring system. The software based on LabVIEW 8. was programmed to collect data, display results in real time, store data, set the over-limit alarm value, and process the least squares fitting algorithm, etc. The real-time display showed the concentration of the PD4 PD1 PD2 PD3 gas under test: all data were stored in an SQL-server database at different pre-set time intervals. In the experiment, we used nitrogen gas as the background gas. Then, pure nitrogen gas and signature ethylene gases at concentrations of 2 ppm, 79.8 ppm, 12 ppm, and 15 ppm were injected into the gas cells, respectively. To eliminate the system and optical noises produced in the Herriot cell, we collected the signal after 1 times average. Figure 5 shows the ethylene gas absorption signals at different concentrations. Abs.ratio (a.u).4.35.3.25.2.15.1.5. ppm 35 ppm 79.8 ppm 12 ppm 15 ppm 2 4 6 8 1 Data points Fig. 5 Spectrum absorption curves for five unknown gas concentrations. Figure 6 shows that the absorption ratio was well correlated with the concentration of the signature gas. The linear relationship between the gas concentration and absorptivity is Gas concentration (ppm) 16 14 12 1 8 6 4 2 2 Equation Adj. R-square Gas co ncent rat io n Gas con cent rat ion Gas concentration Linear fit of gas concentration y=a+b.999 45 Value Standard error Interce pt 1.14 1 1 4 1.11 9 5 5 Slope 5 911.31 5 46 598.13 48..5.1.15.2.25.3 Abs. ratio (au) Fig. 6 Absorption ratio versus concentration of signature gas. y = 5911.3155 x 1.1411 (4) with an R-square of.9996 and a standard error of 1.12. Equation (4) is put into software, then verified using an ethylene gas concentration of 2 ppm.

Yubin WEI et al.: A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor 71 Figure 7 shows that the error lay within ± 2 ppm and was very stable. By calculating a five-point moving average across the calculated concentration data, the concentration stability of final detection was shown to be less than 1 ppm, which met the accurate requirements for fire forecasting in coal mines. Gas concentration (ppm) 3 25 2 15 1 5 Gas concentration 5 1 15 2 Time (min) Fig. 7 Long-term stability of signature ethylene at a concentration of 2 ppm. 5. Conclusions In order to solve the problem of ethylene online detection for the prediction of coal spontaneous combustion, the paper presents a mine optical fiber multi-point ethylene concentration sensor based on the tunable diode laser absorption spectroscopy. Based on the experiments and analysis of the near-infrared spectrum of ethylene, the system employed the 1.62 µm (DFB) wavelength fiber coupled distributed feedback laser as the light source. By using the wavelength scanning technique and with the development of a stable fiber coupled Herriot type long path gas absorption cell, a ppm-level high sensitivity detecting system for the concentration of ethylene gas was realized, which can meet the needs of coal mine goaf fire prediction and provides a new means for the prediction of spontaneous combustion of the coal mine goaf. Acknowledgement This work was supported by the National Natural Science Foundation of China (697758 & 6147585) and Fundamental Research Funds of Shandong University (214YQ11). Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. Reference [1] X. Xian, H. Wang, D. Jiang, and B. Liu, China coal mine fire fighting technology research, Engineering Science, 21, 3(12): 28 32. [2] H. Luo and Y. Liang, Status and prospects of coal spontaneous combustion prediction technology, China Safety Science Journal, 23, 13(3): 76 8. [3] N. Li, Research on gas detection and 2D distribution reconstruction by tunable diode laser absorption spectroscopy technique, Ph.D. dissertation, Zhejiang University, China, 28. [4] J. Reid and D. Labrie, Second harmonic detection with tunable diode lasers-comparision of experiment and theory, Applied Physics B, 1981, 26(3): 23 21. [5] J. M. Supple, E. A. Whittaker, and W. Lenth, Theoretical description of frequency modulation and wavelength modulation spectroscopy, Applied Optics, 1994, 33(27): 6294 632. [6] X. Tu, W. Liu, Y. Zhang, F. Dong, M. Wang, T. Wang, et al., Second-harmonic detection with tunable diode laser absorption spectroscopy of CO and CO 2 at 1.58 μm, Spectroscopy and Spectral Analysis, 26, 26(7): 119 1194. [7] Y. Shang, Y. Wei, C. Wang, T. Lei, and Z. Song, The research of acetylene gas concentration on-line monitoring system based on absorption spectra, Chinese Journal of Sensors and Actuators, 21, 23(2): 171 174. [8] S. Zhang, Q. Wang, Y. Zhang, F. Song, K. Chen, G. chou, et al., Water vapor detection system based on scanning spectra, Photonic Sensors, 212, 2(1): 71 76. [9] D. S. Borns, D. C. Hovde, S. Chen, and J. A. Sivler, Early fire sensing using near IR diode laser spectroscopy, in Proc. SPIE, vol. 4817, pp. 73 81, 22. [1] G. Lv, J. Chang, Q. Wang, Q. Wang, and W. Wei, Research progress of optical H 2 O sensor with a DFB diode laser, Photonic Sensors, 214, 4(2): 113 119. [11] D. P. Leleux, R. Claps, W. Chen, F. K. Tittel, and T. L. Harman, Applications of Kalman filtering to real-time trace gas concentration measurements, Applied Physics B, 22, 74(1): 85 93.