Are you ready for WorkSafe BC s new crystalline silica regulations?

Similar documents
Exposure Control Plan for Drilling/Grinding Concrete

SILICA EXPOSURE PREVENTION PROGRAM

SILICA EXPOSURE CONTROL PLAN

Silica Awareness PPT-SM-SILICA 2014

OSHA s Final Rule on Occupational Exposure to Respirable Crystalline Silica: The Construction Standard

Silica Dust Safety Program

OSHA s Final Rule on Occupational Exposure to Respirable Crystalline Silica

Highlights of Respirable Crystalline Silica. Jim Shelton, CAS Houston North Area Office

Silica Intro. Silica is the second most common element on earth It is 28% of the earth s crust Several forms. Found: dirt, rocks, drywall.

Respirable Crystalline Silica

Managing worker exposure to dust in mines and quarries

OSHA s Respirable Crystalline Silica Standard for Construction. OSHA Cranes & Derricks Subpart CC

University of Delaware Respirable Crystalline Silica Dust Program June 2018

E Light Electric Services, Inc. Workplace Crystalline Silica Exposure Control Policy

OSHA S CRYSTALLINE SILICA RULE: What does it mean for you?

OSHA s Construction Standard for Occupational Exposure to Respirable Crystalline Silica 29 CFR

CHAPTER 39: SILICA AWARENESS

Presented by: Laura Cullom Phillips 66 Rodeo Jay Prescott Shell Martinez Refinery

Specifically. Construction

Silica Protection Plan

OSHA's New Silica Rule Everything You Need to Know. Defined. Respirable Crystalline Silica Dust

OSHA Final Rule: Occupational Exposure to Respirable Crystalline Silica

2. True or False: Inhaling very small crystalline silica can be hazardous to employee health.

John Olaechea Compliance Assistance Specialist OSHA Region VIII 1244 Speer Blvd Suite 551 Denver, CO

Palm Beach State College. Florida s First Public Community College SILICA EXPOSURE CONTROL PLAN

TECHNICAL BULLETIN September 17, 2001

Respirable Crystalline Silica

Practicing Proactive Silica Dust Housekeeping by: Nilfisk, Inc.

SILICA WEBINAR. Chris Chipponeri Chief Operations Officer Hazard Management Services, Inc.

November Head Safety... P. 2-3 Winter Driving Safety... P. 4-5 Do Not Obstruct (Emergency Equipment)... P. 6-7 Power Actuated Tool... P.

Silica Exposure Control Plan. University of Maryland, Baltimore

University of Minnesota Respirable Crystalline Silica Exposure Control Plan. Effective September, 2017

Construction Silica Exposures and Solutions

Silica Exposure Control Program

The New OSHA Silica Standard

Introduction. Welcome to this course! Intended for: Duration: 60 minutes. Respirable Crystalline Silica for Exposed Construction Workers

Respirable Crystalline Silica Program

OSHA S RULE FOR RESPIRABLE CRYSTALLINE SILICA

Health, Safety and Environment Management System. Crystalline Silica Exposure Control Plan PROCEDURE

Vision Painting Inc Safety Management System

Presented By: Kary S. Amin Nova Environmental, Inc. Nova Environmental, Inc.

SILICA EXPOSURE SAFETY POLICY & WRITTEN EXPOSURE CONTROL PLAN

Respirable Crystalline Silica Program

Silica Health Standard. Subpart Z 29 CFR

Mine Dust Management Plan

OSHA s Proposed Silica Rule Randy Nicholls Northwestern Energy

OSHA Respirable Crystalline Silica Standard: Tips for Developing a Compliance Strategy June 2016

Respirable Crystalline Silica Exposure Control Plan

TRAIN THE TRAINER FIELD GUIDE SILICA SAFETY

Health, Safety, Security and Environment

Crystalline Silica Program

(a) Scope and application. This section applies to all occupational exposures to respirable

Respirable Crystalline Silica Exposure Control Program

SILICA EXPOSURE MEASUREMENT IN REAL-TIME FOR CONSTRUCTION

CRYSTALLINE SILICA. Silica (Silicon dioxide) is one of the most common chemical compounds found in nature.

Management of Silica Dust.

SAMPLE. Respirable Silica Exposure Control Plan

OSHA CRYSTALLINE SILICA STANDARD CRYSTALLINE SILICA STANDARD 29 CFR rpbsafety.com

No November 28, 2016 OSHA ISSUES SMALL ENTITY COMPLIANCE GUIDE FOR SILICA IN CONSTRUCTION

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

MATERIAL SAFETY DATA SHEET FOR CONCRETE MASONRY

OSHA Small Entity Compliance Guide for the Respirable Crystalline Silica Standard for General Industry and Maritime

OSHA Small Entity Compliance Guide for the Respirable Crystalline Silica Standard for Construction

Compliance with OSHA s Silica Rule

The MSDS format adheres to the standards and regulatory requirements of the United States and may not meet regulatory requirements in other countries.

Rule s obligations and implementation dates NAPA s guidance documents and other assistance Milling and brooming equipment

SAFETY/RISK/HAZARD ASSESSMENT

OSHA Silica Regulation s Upcoming Impact

OSHA s New Respirable Crystalline Silica Standard for Construction What You Need to Know

GUIDELINE SILICA ON CONSTRUCTION PROJECTS

Competent Person Training. OSHA Silica Standard

Creating a Written Silica Control Plan

Two Main Risks Associated with Foundry Work

How OSHA's New Crystalline Silica Rule Will Affect Your Operations

Edwin L. Heim Company Silica Exposure Written Control Plan

Silica Dust in Construction: Real Case Studies in Exposure Assessment and Hazard Control

TABLE OF CONTENTS PART 8 - MATERIALS AND STORAGE

Occupational Safety and Health Administration

Engineering the Silica Out of Foundries

TAMMY K. CLARK SAFETY & HEALTH CONSULTANT, CONSTRUCTION INDUSTRY

BEGINNING THE MEETING

Safe Work Practices / Procedures / Instruction ASBESTOS. (See also Asbestos Exposure Control Plan )

Breathe Safer. REFERENCE GUIDE This reference guide deals only with the standards for respirable silica for the construction industry.

EBERT CONSTRUCTION CRYSTALLINE SILICA EXPOSURE CONTROL PLAN, PROGRAM & PROCEDURE

Doc No. AQWG_2_0.21. Silica Dust Awareness

Asbestos Operations and Maintenance Plan

Safety Essentials 3/14/2018. Introduction to the NEW NADCA Safety Manual. Greg Santo

Best practice Working safely with fibre cement products

HANDLING AND USE OF ASPHALT MIXING PLANT. A Good Practice Guide on Asphalt Workers Health Protection

Managing Chemical Hazards Silica

There is a list of duties for your employees and a section that explains your duties to comply with the social dialogue agreement.

Seed Treatment Safety and Regulations Crop Protection Perspective. Chip Witcher / Staff Industrial Hygienist / Syngenta Crop Protection

BEST PRACTICE FOR IRON ORE & COAL DUST ENVIRONMENTS

MATERIAL SAFETY DATA SHEET KU20 INDUSTRIAL GRANULES

ISSUE NUMBER: 2 (two) 7 Pages. Identification of Substance / Preparation & Company / Undertaking

Safety Data Sheet White Marble TCC Materials Version 1.0

4/18/2018. What is silica? Respirable Crystalline Silica. Concern: 3 forms of crystalline silica. Silica is found in rock, soil, and sand

Great Western Painting Abrasive Blasting ABRASIVE BLASTING 29 CFR Ventilation 29 CFR Power-operated hand tools.

: PROMATECT -H : Self-supporting calcium silicate board. : Article.

MATERIAL SAFETY DATA SHEET EFFECTIVE DATE: I. IDENTIFICATION

Transcription:

Are you ready for WorkSafe BC s new crystalline silica regulations? As of May 1, 2017, there are changes to sections 6.110-6.115 of WorkSafe BC s Occupational Health & Safety (OHS) Regulation and related OHS Guidelines. What is silica? As a basic component of soil, sand and rock, silica is one of the most widespread minerals on earth. It s most commonly found in quartz, which in turn is used in products like concrete, brick, ceramic tiles, dental fillings, jewelry, tombstones and more. Though it exists in many forms, it becomes crystalline and airborne when exposed to high heat or intense pressure like abrasive cutting, crushing and sawing. That s when you need to be aware. Workers at risk of exposure to respirable crystalline silica Mining, quarrying, farming, foundries, oil & gas Abrasive blasting (e.g., of concrete structures) Jackhammering, chipping, sawing, grinding, hammering, or drilling of rock, concrete, or masonry structures Cutting brick or tiles Sawing or grinding concrete Tuck-point grinding Road construction Loading, hauling, and dumping gravel Sweeping concrete dust Demolition of structures containing concrete Crushing, loading, hauling, or dumping of rock Many building demolition processes Facade renovation, including tuck-point work Abrasive or hydro blasting of concrete Clean-up activities such as dry sweeping or pressurized air blowing of concrete or sand dust Tunneling, excavation, or earth moving of soils with high silica content Date: May 1, 2017 1

Silicosis When crystalline silica particles are inhaled, they make their way deep into your lungs, which, in turn, begin to develop scar tissue nodules around the particles. Though it can take years for full symptoms to appear, silica exposure has been directly linked to lung cancer, kidney disease and chronic obstructive pulmonary diseases. One of the highest risks for workers repeatedly exposed to silica is silicosis, a non-reversible lung disease with symptoms that can range from shortness of breath and chest pains, to an eventual inability to breathe, which could turn fatal. For people with a smoking habit or existing lung conditions such as asthma, exposure to silica can seriously compound debilitating lung and breathing problems. A worker may develop any of three types of silicosis, depending on the airborne concentration of crystalline silica: Chronic silicosis: 10+ years of exposure, relatively low concentrations Accelerated silicosis: 5-10 years after the initial exposure, high concentrations Acute silicosis: from a few weeks to 4-5 years after exposure, very high concentrations (100 X Occupational Exposure Limits [OEL]). While it is rare in humans, it has been observed during sandblasting or tunneling where exposure controls were minimal. Acute silicosis may result in death within a few years. Potential effects of long term exposure: Cancer Long-term unprotected exposures can result in lung cancer. IARC, the International Agency for Research on Cancer, has classified respirable crystalline as Group 1: carcinogenic to humans. AGCIH, the American Conference of Governmental Industrial Hygienists, has classified crystalline silica as A2: Suspected Human Carcinogen. Changes to the OHSR Part 6, Section 6.110 to 6.115.1 Respirable Crystalline Silica and Rock Dust The current legislation is for Rock Dust and was not specific for all work activities that involved potential exposures to respirable crystalline. The section name will be changing to Respirable Crystalline Silica and Rock Dust. Although the majority of changes impact risk assessments, work procedures and controls that are used, there are new requirements for industrial hygiene air monitoring. Because of the low OEL, concentrations of crystalline silica can quickly become a concern on construction and other related work sites where there is a likelihood for silica to be present. The new changes are effective as of May 1, 2017. A full summary is attached to this bulletin. Occupational Exposure Limit for Respirable Crystalline Silica These are the current 8-hour OELs for respirable crystalline silica in BC: Crystalline silica as quartz: 0.025 mg/m3 Crystalline silica as crystobolite: 0.025 mg/m3 Respiratory Protective Equipment Options The following table outlines available solutions for respirators to help protect workers from exposures to crystalline silica. The maximum use concentration of each type of respirator has been provided. If you know what the measured concentrations are from air monitoring, this table will help you select the appropriate level of respirator to protect your workers. Date: May 1, 2017 2

Crystalline Silica Concentration APF Respirator Example Up to 0.25 mg/m3 (10 times the OEL) 10 Half face respirator equipped with a filter (95/99/100 N/P/R) Up to 0.63 mg/m3 (25 times the OEL) 25 Powered air purifying respirator equipped with a HEPA filter Up to 1.25 mg/m3 (50 times the OEL) 50 Full face respirator equipped with a filter (95/99/100 N/P/R) Up to 25 mg/m3 (1000 times the OEL) 1000 Full face powered air purifying respirator equipped with HEPA filter Comments or questions Please contact 1-800-265-1840 to be connected with a 3M Personal Safety Sales Representative in your region. For technical assistance: 1-800-267-4414 References www.cdc.gov/niosh/topics/silica/ ccinfoweb2.ccohs.ca/cheminfo/action.lasso?-database=cheminfo&-layout=display&-response=detail.html&-op=eq& CHEMINFO+RECORD+NUMBER=79E&-search minerals.usgs.gov/minerals/pubs/commodity/silica/780292.pdf www2.worksafebc.com/portals/construction/hazardousmaterials.asp?reportid=34096 References accessed April 19, 2017 Information and resources www2.worksafebc.com/portals/construction/hazardousmaterials.asp?reportid=34096 Download toolbox meeting guides from http://www2.worksafebc.com/portals/construction/toolboxmeetingguides-topic. asp?reportid=34825 Download sample exposure control plans from http://www.worksafebc.com/publications/health_and_safety/by_topic/ occupational_hygiene/default.asp#silica Approved Changes to 6.110-6.115.1 effective May 1, 2017 www.worksafebc.com/en/law-policy/public-hearings-consultations/closed-public-hearings-and-consultations/ bod-approves-amendments-ohsr www.worksafebcmedia.com/enews/insight/170201/_story2.htm Date: May 1, 2017 3

WorkSafe BC OHSR Respirable Crystalline Silica and Rock Dust (formerly called Rock Dust) Section Current Requirement Section 6.110 Rock Dust 6.111 Dust Control 6.112 Restricted Access Sections 6.110 to 6.115 apply to rock crushing, drilling, mucking, excavation, loading, transportation, road grading, road construction or conveying of rock or similar operations. (1) The employer must ensure that dust concentrations to which a worker may be exposed are maintained at or below the established exposure limits, by one or a combination of: (a) mechanical ventilation, (b) the use of water spray, (c) other equally effective methods. (2) When practicable, ventilation systems for removing dust must be equipped with effective filtration. 6.110 Respirable Crystalline Silica and Rock Dust 6.111 Application 6.112 Risk Assessment New Requirement Effective May 1, 2017 The title of the section has changed from Rock Dust to Respirable Crystalline Silica and Rock Dust. This section is also being replaced with a definition section. Definitions for abrasive blasting, blasting enclosure, cleaning of castings, concrete or masonry material, control measures, dust reduction system, exposure limit, RCS dust, risk assessment, sandblasting, silica flour, silica process, and siliceous are included. Sections 6.112 to 6.112.7 apply to a workplace where a worker is or may be (a) engaged in a silica process, or (b) exposed to potentially harmful levels of RCS dust. (1) In this section: existing monitoring data means data (a) gathered under section 5.53 or 6.112.3, or (b) as described in section 6.112.4(2)(b). (2) An employer must not permit workers to engage in a work activity or a silica process that may expose workers to RCS dust unless a risk assessment has first been completed by a qualified person. (3) The risk assessment must include consideration of all of the following: (a) the hazards of RCS dust, including the exposure limit; (b) any information contained on a label or in a safety data sheet provided by a supplier, manufacturer or employer in respect of (i) the crystalline silica content in the materials to be used in the silica process, and (ii) the health effects of RCS dust exposure; (c) the scope, circumstances and nature of the work activity or silica process, including (i) whether section 5.50 applies, given the length of the shift, (ii) any changes between shifts in the scope, circumstances or nature of the work activity or silica process, (iii) the potential level and duration of exposure to RCS dust during the work activity or while engaging in the silica process; (d) the effectiveness of existing and planned control measures, as determined through exposure monitoring, to prevent or minimize worker exposure to RCS dust, including with respect to access to the workplace by unprotected workers; (e) any additional information the employer needs to complete the risk assessment. (4) A qualified person may rely on existing monitoring data for the purpose of assessing control measures under subsection 3(d) only if it is reasonable to do so based on (a) the relevance of the existing monitoring data, and (b) whether additional air monitoring may be needed to reassess the effectiveness of existing and planned control measures because of changes in personnel or to the scope, circumstances or nature of the work activity or silica process. (5) An employer must ensure that the risk assessment is reviewed by a qualified person if any of the following occur: (a) there is reason to believe the risk assessment is no longer valid; (b) there has been a significant change in the scope, nature or circumstances of the work activity or silica process to which the risk assessment relates; (c) the results of any exposure monitoring show it to be necessary. (6) If changes to the risk assessment are necessary as a result of the review under subsection (5), the employer must ensure that the risk assessment is changed accordingly. Comment The expanded definitions help employers understand when, where and for what work activities the regulations apply. Consult the regulations for full definitions. Proposed amendments for RCS dust section 6.112.1 to 6.112.7 apply to workplaces where a worker is or may be engaged in a silica process or exposed to potentially harmful levels of RCS dust. If silica is present on the worksite, this section will likely apply. Risk depends on: How long workers are exposed to dust. The concentration of RCS dust that workers are exposed to, usually determined by air monitoring. Size of the dust particulate. Must be done by qualified people. Date: May 1, 2017 4

WorkSafe BC OHSR Respirable Crystalline Silica and Rock Dust (formerly called Rock Dust) continued 6.112.1 New section/requirement 6.112.1 Exposure Control Plan (ECP) (1) If a risk assessment indicates that a worker is or may be exposed to RCS dust, the employer must (a) ensure that a qualified person develops an exposure control plan meeting the requirements of section 5.54 and subsection (3) of this section, and (b) implement the exposure control plan. (2) If a risk assessment is changed under section 6.112(6), the employer must ensure that (a) the exposure control plan is amended to address the changes to the risk assessment, and (b) the amendments to the exposure control plan are implemented. (3) For the purposes of section 5.54(2)(d), the written work procedures within an exposure control plan must address at least the following: (a) the containment of silica processes, if used as a control measure; (b) the effective control of worker exposure to RCS dust using dust reduction systems; (c) safe work practices and procedures; (d) the correct selection, use, care and maintenance of any required personal protective equipment and clothing; (e) emergency procedures; (f) the removal, cleanup and disposal of RCS dust and debris, including the measures that will be used for the purposes of meeting the requirements of section 6.112.6. RCS dust is a designated substance under OHSR Section 5.57. Exposure Control Plans must be developed by qualified individuals who meet requirements of 5.54. 6.112.2 New section/requirement 6.112.2 Elimination or Control of Exposure (1) An employer must, to the extent it is practicable, avoid the use of products or materials containing crystalline silica by replacing them with substances or processes that, under normal conditions of use, eliminate the risk of worker exposure to RCS dust. (2) If it is not practicable to eliminate the risk of worker exposure to RCS dust, the employer must control the risk below the applicable exposure limit under section 5.48 by applying control measures that (a) are appropriate to the work activity, (b) are consistent with the risk assessment and with sections 5.55 and 5.57, and (c) include, in order of priority, (i) the design and use of engineering controls, including appropriate dust reduction systems, containment of silica processes, and the provision and use of suitable work equipment and materials, (ii) the control of RCS dust exposure through administrative controls, including work practice controls, and (iii) if the control measures set out in paragraphs (i) and (ii) are not adequate to control exposure, the provision and use of suitable personal protective equipment in addition to those control measures. The order of hierarchy of controls is now clearly implied in this section. Current Section 5.55 could be interpreted as a choice: Substitution/Elimination Administrative Personal Protective Equipment Routine full shift use of Respiratory Protective Equipment should be avoided whenever possible. 6.112.3 New section/requirement 6.112.3 Air Monitoring for RCS Dust (1) If there is a potential for hazardous exposure to RCS dust in a work activity or silica process, the employer must (a) ensure that air monitoring is conducted using a sampling and analytical method referred to in subsection (2) (i) during the first shift of the work activity or silica process, and (ii) as necessary throughout the work activity or silica process to ensure that control measures are effective to prevent or minimize worker exposure to RCS dust, and (b) keep, for at least 10 years, records of the results of air monitoring conducted under this section. (2) Acceptable sampling and analytical methods for the purpose of subsection (1) are as follows: (a) a method detailed in a standard occupational hygiene reference published by (i) the National Institute for Occupational Safety and Health, or (ii) the Occupational Safety and Health Administration; (b) another method acceptable to the board. Air monitoring is now required and results must be kept on file for 10 years. Required when there is potential for hazardous exposure to RCS dust. Airborne concentration levels reaching or exceeding 50% of the OEL. Date: May 1, 2017 5

WorkSafe BC OHSR Respirable Crystalline Silica and Rock Dust (formerly called Rock Dust) continued 6.112.4 New section/requirement 6.112.5 New section/requirement 6.112.4 Exceptions to Monitoring Requirements 6.112.5 Blasting Enclosures (1) In this section, equivalent work operations means work operations closely matching the silica processes, types of materials, work practices, control measures and environmental conditions prevailing in the employer s current work operations. (2) Despite section 6.112.3, an employer is not required to monitor the exposure of workers to RCS dust if a qualified person determines that (a) existing control measures are effective in keeping worker exposure as low as reasonably achievable below the exposure limit, and (b) the employer (i) has previously monitored for RCS dust exposure during equivalent work operations and there is no reason to believe that the results of the previous monitoring would not continue to apply, or (ii) has objective air monitoring data that was collected during equivalent work operations through industry surveys or peer-reviewed or scientific studies that use sampling and analytical methods referred to in section 6.112.3(2). (3) An employer must keep, for at least of 10 years, a record documenting the following, as applicable: (a) the previous monitoring data used for the purpose of subsection (2)(b)(i); (b) the source of the objective exposure monitoring data, and the data itself, referred to in subsection (2)(b)(ii). An employer must ensure that that a blasting enclosure is used for the following activities only: (a) abrasive blasting; (b) maintenance of the blasting enclosure and all associated equipment, including ventilation and blasting equipment. Previous air monitoring results for RCS dust may be used if the results are for similar operations and there is no reason to believe that the results of the previous air monitoring would not continue to apply. Blasting enclosure can only be used for abrasive blasting. Other work activities are not permitted inside blasting enclosures unless for maintenance of enclosure or maintenance of blasting related equipment. 6.112.6 New section/requirement 6.112.6 Housekeeping (1) In addition to the requirements of section 5.82(2), an employer must ensure that all of the following requirements are met: (a) all workplaces and work-related areas and equipment where RCS dust may accumulate must be cleaned at the end of every shift, if practicable, using one or a combination of (i) a vacuum or similar device, (ii) wet cleanup methods, or (iii) another method that is effective and in accordance with the safe work practices contained in the exposure control plan; (b) if a vacuum or other similar device is used, the vacuum or device must be (i) designed, maintained, tested and used in accordance with (A) the manufacturer s specifications, or (B) the instructions of a professional engineer, and (ii) equipped with an effective HEPA filter on the exhaust; (c) if wet clean-up methods are used, any slurry generated by those methods must be removed when the work is completed in such a manner as to avoid a secondary RCS dust exposure hazard; (d) waste material must be placed in sealable containers and promptly disposed of to prevent RCS dust from re-entering the workplace. (2) An employer must not permit the use of blowers, compressed air, dry sweeping or dry mopping to clean up or remove RCS dust. No blowers, compressed air, dry sweeping or dry mopping to clean or remove RCS dust. Wet clean-up methods or properly maintained HEPA vacuums must be used. All workplaces, areas and surfaces that can accumulate dust must be cleaned at the end of every shift (i.e., cabs of trucks, heavy equipment, site office, etc.). Waste materials must be in sealed containers to prevent RCS from re-entering the workplace. Date: May 1, 2017 6

WorkSafe BC OHSR Respirable Crystalline Silica and Rock Dust (formerly called Rock Dust) continued 6.112.7 New section/requirement 6.113 Rock Drills A rock drill, other than a manually powered rock drill, must be equipped with a dust suppression system, acceptable to the Board, that (a) uses water jet, spray, or other equally effective means to suppress drilling dust effectively, and (b) operates whenever the drill is in use. 6.112.7 Instruction and Training An employer must ensure that a worker who is or may be exposed to RCS dust receives adequate instruction and training in all of the following: (a) the hazards and health effects of inhaling RCS dust; (b) safe work practices and procedures; (c) the correct operation and use of any required equipment and engineering controls; (d) the purpose and limitations of personal protective equipment, and the correct selection, fitting, use, care and maintenance of that equipment; (e) housekeeping practices described in section 6.112.6. Workers must be properly trained about the hazards and how to protect themselves from silica. No changes No changes Not applicable 6.114 Rock Crushing Plants 6.115 Asphalt Mixing Plants Rock crushing plants must be equipped with the following dust controls: (a) rock crushers, including jaw, roll, cone, or hammer-mills must have an effective mechanical exhaust system; (b) screens releasing dust must be partially covered and have an effective mechanical exhaust system or an effective water spray system; (c) the screen discharge hopper must be enclosed and if dust is released must have an effective mechanical exhaust system or an effective water spray system; (d) material transfer points releasing dust must have an effective mechanical exhaust system or an effective water spray system; (e) a suitable dust collector must be installed on a mechanical exhaust system; (f) dust discharged from a mechanical exhaust ventilation system must not be recirculated into work areas; (g) when practicable, the operator must be enclosed in a pressurized cab equipped with air filtration and noise suppression. Asphalt mixing plants must be equipped with the following dust controls: (a) a dust-tight seal must be installed at the dryer discharge to the hot stone elevator; (b) the screen enclosure must have a mechanical exhaust system that maintains a negative pressure within the screen enclosure and the elevator feed system; (c) the mixing chamber must have a mechanical exhaust system that maintains a negative pressure on the bin discharge to the mixer or elevator feed system; (d) on continuous-mix plants the conveyor feeding the mixing chamber must be enclosed and connected to the mechanical exhaust system; (e) the screen overflow chutes and hoppers handling screen overflow must be enclosed, and the waste fines conveyor system must be enclosed at all material transfer and discharge points; No changes No changes Not applicable No changes No changes Not applicable Date: May 1, 2017 7

WorkSafe BC OHSR Respirable Crystalline Silica and Rock Dust (formerly called Rock Dust) continued (f) the discharge of overflow or waste fines material must be to an enclosed container, which must be emptied in a manner that prevents contamination of the work area; (g) material transfer points between sections of the asphalt mixing plant must be fitted with effective dust seals; (h) conveyor and elevator cover seals must be dust-tight; (i) on batch-mix plants, dust-tight seals must be installed on manual draw chute levers and on the weigh-hopper and bin; (j) a suitable dust collector must be installed on the mechanical exhaust system, with the discharge from the dust collector located so as to prevent the recirculation of contaminated air to areas occupied by workers. 6.115.1 New section/requirement 6.115.1 Application of RCS Dust Provisions For greater certainty, in respect of a workplace described in section 6.111, the requirements set out in sections 6.113 to 6.115 are in addition to the requirements set out in sections 6.112 to 6.112.7. 6.115.1 does state that requirements of 6.113, 6.114 & 6.115 are in addition to 6.110 to 6.112. Rock crushing/drilling operations and asphalt mixing plants may need to re-evaluate their work practices and controls and update their ECPs. 3M Personal Safety Division 3M Canada P.O. Box 5757 London, ON N6A 4T1 Phone 1-800-364-3577 Web www.3m.ca/safety Date: May 1, 2017 3M and 3M Science. Applied to Life. are trademarks of 3M. Used under license in Canada. 2017, 3M. All rights reserved. 1704-08439 E BA-16-23553 8