HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Similar documents
HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Minimum size for maximum performance

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

ASV. Adaptive Support Ventilation

Supporting you in saving lives!

HAMILTON-C3. The compact high-end ventilator

Intelligent Ventilation solution from ICU to MRI

HAMILTON-G5. The modular high-end ventilation solution

Safe ventilation at rest and on the move

HAMILTON-C6. The next generation of intelligent ICU ventilators

Safe ventilation at rest and on the move

INTELLiVENT -ASV. The world s first Ventilation Autopilot

HAMILTON-T1 Intelligent transport ventilation for armed forces

With INTELLiVENT -ASV, the world s first fully closed loop ventilation. The next era of Intelligent Ventilation

More safety for your patient

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Milestones of Aeonmed Ventilators

Safe and Intuitive Neonatal Ventilation

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Mechanical Ventilation

fabian Therapy evolution Our 2-in-1 device

HAMILTON-C1 neo. Technical specifications

fabian HFO: Modular, Powerful, Versatile.

IEC C LASSIFICATIONS:


2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

HAMILTON-MR1. Technical specifications HAMILTON-MR1

Inspiration 7i Ventilator

Flight Medical presents the F60

D Beyond essentials DRÄGER SAVINA 300 SELECT

evolution 3e Ventilators

Monnal T60. Touch and Breathe.

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Focused on essentials DRÄGER SAVINA 300

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

fabian HFO Our 4-in-1 device

D Beyond essentials DRÄGER SAVINA 300 SELECT

Panther 5 Acute Care Ventilator

Blease900 Ventilator PATIENT CENTERED VENTILATION

Oxylog 3000 plus Emergency & Transport Ventilation

Dräger Savina Sub-Acute Care Ventilation

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

A9600 Anesthesia Workstation. Your healthcare, we care.

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Supporting your patients every breath

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

V8800 Ventilator System. Your healthcare, we care.

Technical Data and Specifications

INTENSIVE CARE VENTILATORS

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Giving neonates a future

Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

How Ventilators Work. Chapter 3

Emergency Transport and Ventilation

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Focused on essentials DRÄGER SAVINA 300

Entry to the premium class!

Puritan Bennett 840 Universal Ventilator

GE Healthcare. Aestiva/5. More than superior ventilation

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

DATA SHEET. VENTILATION SERVO-s

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Anesthesia Workstation

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Hospital and Transport for Controlled Breathing

Selecting the Ventilator and the Mode. Chapter 6

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

The centerpiece of a comprehensive anaesthesia workstation

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Airox Supportair Ventilator

WILAmed INTENSA. Intensive Care Ventilator System

ekom Compressor for Medical Air Sonata with Ekom

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Technical specifications for SW version 2.0.x. Mode form Mode name Mode Adult/Ped Neonatal

D Designed for non-invasive ventilation DRÄGER CARINA

Ventilator Training Module

SLE5000 Infant Ventilator with HFO

New A7 Anesthesia Workstation

Using Common Ventilator Graphics to Provide Optimal Ventilation

NEONATAL/INFANT VENTILATOR

Operator s Manual Addendum

State-of-the-art anesthesia technology

MT Excellent performance and reliability EVITA 4 EDITION

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Transport Ventilators

Software enhancements

fabian HFOi Our 4-in-1 device

Corporate Overview and Product Summary

An intuitive and innovative answer to your anaesthesia challenges

Transcription:

HAMILTON-C2 HAMILTON-C2 The universal ventilation solution

The universal ventilation solution HAMILTON-C2 - The compact ventilation solution The HAMILTON-C2 mechanical ventilator is a universal ventilation solution for all patient groups. The HAMILTON-C2 s compact design and independence from external power and air supplies allow for maximum mobility throughout the hospital. The integrated high-performance turbine guarantees optimal performance even with noninvasive ventilation. General purpose device for all patient groups, from neonates to adults More than 6 hours of battery operating time Independence from gas cylinders or compressors Compact design for maximum mobility High-performance NIV ventilation I am particularly excited about the turbine-driven line of ventilators that Hamilton Medical provides. Evidence shows that these machines are more responsive to the patients inspiratory demand than the gas-driven machines. Thomas Berlin, Director of Respiratory Care, Florida Hospital, Orlando (FL), USA Hamilton Medical HAMILTON-C2 3

Intelligent ventilation for various situations Enhanced safety for your intensive care patients The Ventilation Cockpit of the HAMILTON-C2 allows the user to check critical parameters at a glance and provides the patient s status as a valuable tool for clinical assessment. The ASV mode provides increased safety and comfort for your patients by adjusting the ventilation to the patients normal breathing pattern. In doing so, ASV prevents abnormal breathing patterns as well as apnea and tachypnea. Integrated high-performance turbine The integrated high-performance turbine provides pneumatic performance that can match any compressed-airbased intensive care ventilator. A peak-flow rate of up to 240 l/min even allows the HAMILTON-C2 to provide noninvasive ventilation. Mobility for intrahospital transport The high-performance turbine enables the HAMILTON-C2 to be completely independent from compressed air, and its integrated battery allows you to ventilate your patients during intrahospital transport for more than six hours without the need of an external power source. The compact design of the HAMILTON-C2 makes handling of the ventilator much easier. Noninvasive ventilation Intrahospital transport 4

Performance From neonates to adults The HAMILTON-C2 provides a tidal volume range of 20 2000 ml for adult and pediatric patients, or optionally 2 300 ml for neonates. This allows for the effective, safe, and lung-protective ventilation of all patient groups. Automatic synchronization The IntelliTrig function automatically adjusts the inspiratory and expiratory trigger sensitivity to potential leaks and ensures synchronization with the patient s breathing pattern, for both invasively and noninvasively ventilated patients. Pressure, volume, and flow measurement The proximal flow sensor measures the pressure, volume, and flow directly at the patient s airway opening. This provides the required sensitivity and response time, and prevents dead space ventilation. Your patient is better synchronized and has less work of breathing as a result. Neonatal ventilation Invasive ventilation Hamilton Medical HAMILTON-C2 5

Product overview 1 Integrated handle 2 3 Patient interfaces and ports Press & turn control knob 4 4 Ventilation Cockpit 5 360 visible alarm lamp 6 CO 2, Nurse call (optional communication board) 1

5 3 2 6

- Patients in the medical intensive care unit could be extubated earlier following the introduction of ASV. 5

More safety and comfort for your patients Enhanced patient comfort Each Hamilton Medical ventilator features the intelligent ventilation mode ASV (Adaptive Support Ventilation). ASV measures the patient s lung mechanics and activity on a breath-by-breath basis and automatically adjusts ventilation, from intubation to extubation. ASV is well established in intensive care units and, as the standard mode for the transport of intubated patients since 1998, has been shown to improve patient/ventilator 1), 2) interaction. 1 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9. 2 Sulzer CF. Anesthesiology. 2001 Dec;95(6):1339-45. 3 Sulemanji D. Anesthesiology. 2009 Oct;111(4):863-70. 4 Kirakli C. Eur Respir J. 2011 Oct;38(4):774-80 5 Chen CW. Respir Care. 2011 Jul;56(7):976-83. Lung-protective ventilation ASV ensures via an optimal breathing pattern that the patient receives the set minute volume, irrespective of the patient s activity. As part of this process, ASV employs lung-protective strategies to minimize complications from AutoPEEP and volutrauma/barotrauma. ASV also prevents apnea, tachypnea, excessive dead space ventilation, and excessively large breaths. 3) Decreased ventilation time Clinical studies show that 4), 5) ASV supports earliest possible spontaneous breathing by the patient 4), 5) ASV shortens the ventilation time in various patient groups Hamilton Medical HAMILTON-C2 9

Ease of use Intuitive operation In close cooperation with users and ventilation experts, our engineers have designed the HAMILTON-C2 user interface to allow intuitive operation and direct access to important settings. All Hamilton Medical ventilators are operated according to the same principles, which makes switching between different devices very easy. Easy-to-understand monitoring Ventilators display large amounts of data that is often difficult to interpret. The configurable touch screen display, referred to as the Ventilation Cockpit, consolidates the diverse monitoring data, and presents it numerically and in various graphics panels. These easy-to-understand views provide an at-a-glance overview of the patient s current ventilation status, and offer a reliable basis for therapy decisions. More time for your patients In ASV mode, the ventilator continuously adjusts to the patient s breathing activity and lung conditions. This means fewer user interactions are required and fewer alarms are generated 1), giving you more time for your patients. Monitoring window More time for your patient 1 Zhu F. Anesthesiology. 2015 Apr;122(4):832-40 10

2 4 3 1 The Ventilation Cockpit 1 Dynamic lung - Provides a real-time display of lung compliance, resistance, and breathing activity 5a 2 Direct access to the most important settings 3 The four most important monitoring parameters 4 5 Configurable waveforms for flow, pressure, and CO 2 Display options of the Ventilation Cockpit: a) ASV Graph b) Vent Status c) Trends (not shown) d) Loops (not shown) 5b Hamilton Medical HAMILTON-C2 11

What ASV does for us as therapists is it allows us to make sure that we are crafting the breath in the absolutely best possible way for that patient at that time. Craig Jolly, Adult Clinical Education Coordinator University Medical Center, Lubbock (TX), USA

Increased efficiency Integrated commercial considerations Ventilators are capital goods that need to be evaluated for cost efficiency. Factors including treatment costs and the use of human resources play an important role in this process. Assembled with an extensive standard equipment package that is easy to maintain, Hamilton Medical ventilators are an attractive investment with respect to purchase price and operating costs. Reduction of treatment costs Each eliminated ventilation day significantly reduces treatment costs on average by 1,500 USD. 1) It has been shown that the use of Hamilton Medical ventilators and ASV can reduce ventilation time. In addition, the ventilator is now available for the next patient much earlier. A shorter ventilation time also reduces the risk of ventilator associated pneumonia (VAP), which can result in costs of up to 57,000 USD per case. 2) Better use of human resources 1 Dasta JF et al. Critical Care Med. 2005 Jun;33:1266-71 2 Cocanour CS et al. Surg Infect. 2005 Spring;6:65-72 3 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9 4 Petter AH. Anesth Analg. 2003 Dec;97(6):1743-50 Hamilton Medical ventilators, along with ASV, can reduce the time needed for standard settings and alarm management while maintaining ventilation quality. 3), 4) This frees up time for other aspects of patient care. Thanks to the ease of operation, consistent operating concepts across devices, and the free e-learning offerings from Hamilton Medical, the effort for education and training is also reduced. Hamilton Medical HAMILTON-C2 13

Attention to detail Operation via touch screen or press & turn knob You can operate the HAMILTON-C2 via the touch screen or by using a single knob. Hard keys provide direct access to the most important functions. Customizable user interface You can configure the display layout with different waveforms, loops, trends, or intelligent panel graphics to suit your institution s needs and protocols. Nurses and clinicians can have their own preferred layout. Access the Monitoring window with the touch of a button at any time during active ventilation. Free and open e-learning on mechanical ventilation Join over 15,000 users on the Hamilton Medical College e-learning platform. It provides free and open e-learning modules on the basics of mechanical ventilation, as well as on Hamilton Medical products and features. Register now at college.hamilton-medical.com. For some modules, a certificate is issued upon successful completion. You can even receive Continuing Respiratory Care Education (CRCE) credits from the American Association of Respiratory Care (AARC) for some modules. Customizable user interface Clinicians using the e-learning platform 14

Neonatal ventilation Tidal volumes as low as 2 ml With the Neonatal option, the HAMILTON-C2 provides tidal volumes as low as 2 ml for effective, safe, and lung-protective ventilation even for the smallest patients. 1) The proximal flow sensor specifically developed for neonates precisely measures the pressure, volume, and flow directly at the infant s airway opening, ensuring the required trigger sensitivity. This provides improved synchronization and less work of breathing. Adaptive synchronization, even with uncuffed tubes Leaks are one of the issues encountered in the ventilation of neonates as a result of using uncuffed tubes. The IntelliTrig leak compensation function automatically adjusts the inspiratory and expiratory trigger sensitivity to leaks. This enables adaptive synchronization with the neonate s breathing pattern. ncpap-ps mode 1 Volume-targeted versus pressure-limited ventilation in the neonate (Review), 2011 Morley CJ The ncpap-ps mode is designed in such a way that you set the desired CPAP and inspiratory pressure. Flow and pressure measurement recognizes patient efforts and supports each breath up to the desired inspiratory pressure. A backup rate guarantees minimum patient ventilation. Flow is adjusted automatically based on patient conditions and leaks. ncpap-ps tries to avoid unintended peak pressures as well as apnea, enables highly efficient leak compensation, and helps to reduce oxygen consumption. Neonatal ventilation with the HAMILTON-C2 Neonatal ventilation during intrahospital transport Hamilton Medical HAMILTON-C2 15

Hamilton Medical Intelligent Ventilation since 1983 In 1983 Hamilton Medical was founded with a vision: To develop intelligent ventilation solutions that make life easier for patients in critical care and for the people who care for them. Today, Hamilton Medical is a leading manufacturer of critical care ventilation solutions for a wide variety of patient populations, applications, and environments. The right ventilation solution for every situation The ventilators from Hamilton Medical ventilate all of your patients; in the intensive care unit, during an MRI procedure and in all transport situations, from the neonate to the adult. Each of these ventilators is equipped with the same standardized user interface and uses the same Intelligent Ventilation technologies. This enables Hamilton Medical ventilators to help you to Increase the comfort and safety of your patients Make life easier for the caregivers Increase efficiency and return on investment 689272.03 Specifications are subject to change without notice. ASV and INTELLiVENT are trademarks of Hamilton Medical. Not all options are available in all countries. 2016 Hamilton Medical AG. Hamilton Medical AG Via Crusch 8 7402 Bonaduz, Switzerland +41 58 610 10 20 info@hamilton-medical.com www.hamilton-medical.com