HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

Similar documents
HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Minimum size for maximum performance

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

ASV. Adaptive Support Ventilation

HAMILTON-C3. The compact high-end ventilator

HAMILTON-G5. The modular high-end ventilation solution

Supporting you in saving lives!

HAMILTON-C6. The next generation of intelligent ICU ventilators

Intelligent Ventilation solution from ICU to MRI

Safe ventilation at rest and on the move

INTELLiVENT -ASV. The world s first Ventilation Autopilot

Safe ventilation at rest and on the move

With INTELLiVENT -ASV, the world s first fully closed loop ventilation. The next era of Intelligent Ventilation

HAMILTON-T1 Intelligent transport ventilation for armed forces

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

More safety for your patient

fabian Therapy evolution Our 2-in-1 device

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Flight Medical presents the F60

evolution 3e Ventilators

Inspiration 7i Ventilator

IEC C LASSIFICATIONS:

fabian HFO Our 4-in-1 device

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Mechanical Ventilation

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

fabian HFO: Modular, Powerful, Versatile.

Milestones of Aeonmed Ventilators

Panther 5 Acute Care Ventilator

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Safe and Intuitive Neonatal Ventilation

HAMILTON-MR1. Technical specifications HAMILTON-MR1

Blease900 Ventilator PATIENT CENTERED VENTILATION

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

HAMILTON-C1 neo. Technical specifications

Monnal T60. Touch and Breathe.

Technical Data and Specifications

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Supporting your patients every breath

Dräger Savina Sub-Acute Care Ventilation

GE Healthcare. Aestiva/5. More than superior ventilation

Oxylog 3000 plus Emergency & Transport Ventilation

D Beyond essentials DRÄGER SAVINA 300 SELECT

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

D Beyond essentials DRÄGER SAVINA 300 SELECT

INTENSIVE CARE VENTILATORS

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Focused on essentials DRÄGER SAVINA 300

A9600 Anesthesia Workstation. Your healthcare, we care.

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Emergency Transport and Ventilation

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Airox Supportair Ventilator


Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

WILAmed INTENSA. Intensive Care Ventilator System

Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

Using Common Ventilator Graphics to Provide Optimal Ventilation

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

How Ventilators Work. Chapter 3

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

fabian HFOi Our 4-in-1 device

Hospital and Transport for Controlled Breathing

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

DATA SHEET. VENTILATION SERVO-s

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

MT Excellent performance and reliability EVITA 4 EDITION

ekom Compressor for Medical Air Sonata with Ekom

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

D Designed for non-invasive ventilation DRÄGER CARINA

Entry to the premium class!

The centerpiece of a comprehensive anaesthesia workstation

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Giving neonates a future

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ

Anesthesia Workstation

Focused on essentials DRÄGER SAVINA 300

Selecting the Ventilator and the Mode. Chapter 6

An intuitive and innovative answer to your anaesthesia challenges

V8800 Ventilator System. Your healthcare, we care.

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

Lung recruitment maneuvers

RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

Puritan Bennett 840 Universal Ventilator

SLE5000 Infant Ventilator with HFO

Intensa GO Alternate Care Ventilator

SLE5000 Neonatal Ventilator with High Frequency Oscillation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Mechanical Ventilation. Flow-Triggering. Flow-Triggering. Advanced Concepts. Advanced Concepts in Mechanical Ventilation

Operator s Manual Addendum

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

NEONATAL/INFANT VENTILATOR

Technical specifications for SW version 2.0.x. Mode form Mode name Mode Adult/Ped Neonatal

Transcription:

HAMILTON-C3 HAMILTON-C3 The compact high-end ventilator

The compact high-end ventilator HAMILTON-C3 - The all-rounder for ICUs The HAMILTON-C3 ventilator is a modular high-end ventilation solution for all patient groups. The compact design and independence from compressed air allow maximum mobility throughout the hospital. The integrated high-flow turbine guarantees an optimal pneumatic performance even in the presence of leakage (NIV). P/V Tool Pro: Protective Ventilation Tool for lung assessment and recruitment High-performance NIV ventilation Compact and independent from compressed air Adult, pediatric, and neonatal ventilation To a colleague I would recommend the HAMILTON-C3. It s an all-in-one vent. It has great transport capabilities with the battery life and the turbine, and your patients, for the most part, never have to change to another ventilator. Kathy Lira, Neonatal Pediatric Education Coordinator, University Medical Center, Lubbock (TX), USA Hamilton Medical HAMILTON-C3 3

Intelligent Ventilation solutions Automated lung-protective ventilation with ASV The HAMILTON-C3 features the Intelligent Ventilation mode, Adaptive Support Ventilation (ASV ). ASV maintains an operator-set minute volume, and continuously determines respiratory rate, tidal volume, inspiratory pressure, and inspiratory time automatically depending on the patient s lung mechanics and effort. ASV adapts ventilation breath by breath, 24 hours a day, from intubation to extubation. P/V Tool Pro: Protective Ventilation Tool for lung assessment and recruitment The optional P/V Tool Pro performs a respiratory mechanics maneuver that records a quasi-static pressure/volume curve showing both the inflation and deflation curves. This data can then be analyzed to determine the lung recruitability and recruitment strategy to apply. The P/V Tool can also be used for lung-recruitment maneuvers and to display the recruited lung volume. The P/V Tool is particularly helpful for ARDS patients, as appropriate lung recruitment and the correct setting of PEEP as an anti-derecruiting force are critical. Invasive ventilation P/V Tool Pro for lung assessment and recruitment 4

For various needs Optimal performance for noninvasive ventilation The integrated high-flow turbine provides impressive pneumatic performance. The HAMILTON-C3 turbine delivers a peak flow rate of up to 240 l/min, providing optimal performance, even with noninvasive ventilation. Mobility for intrahospital transport The HAMILTON-C3 s compact design and independence from external power and air supplies allow for mobility and easy handling throughout the hospital. The HAMILTON-C3 can be easily mounted onto a trolley. Mobility for intrahospital transport Noninvasive ventilation Hamilton Medical HAMILTON-C3 5

Product overview 1 Integrated handle 2 Patient interfaces and ports 3 4 Press & turn control knob Ventilation Cockpit 4 5 360 visible alarm lamp 6 CO2, SpO2, Nurse call (optional communication board) 1

5 3 2 6

- Patients in the medical intensive care unit could be extubated earlier following the introduction of ASV. 5

More safety and comfort for your patients Enhanced patient comfort Each Hamilton Medical ventilator features the Intelligent Ventilation mode ASV (Adaptive Support Ventilation). ASV measures the patient s lung mechanics and activity on a breath-by-breath basis and automatically adjusts ventilation, from intubation to extubation. ASV is well established in intensive care units and, as the standard mode for the transport of intubated patients since 1998, has been shown to improve patient/ventilator 1), 2) interaction. 1 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9. 2 Sulzer CF. Anesthesiology. 2001 Dec;95(6):1339-45. 3 Sulemanji D. Anesthesiology. 2009 Oct;111(4):863-70. 4 Kirakli C. Eur Respir J. 2011 Oct;38(4):774-80 5 Chen CW. Respir Care. 2011 Jul;56(7):976-83. Lung-protective ventilation ASV ensures via an optimal breathing pattern that the patient receives the set minute volume, irrespective of the patient s activity. As part of this process, ASV employs lung-protective strategies to minimize complications from AutoPEEP and volutrauma/barotrauma. ASV also prevents apnea, tachypnea, excessive dead space ventilation, and excessively large breaths. 3) Decreased ventilation time Clinical studies show that 4), 5) ASV supports earliest possible spontaneous breathing by the patient 4), 5) ASV shortens the ventilation time in various patient groups Hamilton Medical HAMILTON-C3 9

Ease of use Intuitive operation In close cooperation with users and ventilation experts, our engineers have designed the HAMILTON-C3 user interface to allow intuitive operation and direct access to important settings. All Hamilton Medical ventilators are operated according to the same principles, which makes switching between different devices very easy. Easy-to-understand monitoring Ventilators display large amounts of data that is often difficult to interpret. The configurable touch screen display, referred to as the Ventilation Cockpit, consolidates the diverse monitoring data, and presents it numerically and in various graphics panels. These easy-to-understand views provide an at-a-glance overview of the patient s current ventilation status, and offer a reliable basis for therapy decisions. More time for your patients In ASV mode, the ventilator continuously adjusts to the patient s breathing activity and lung conditions. This means fewer user interactions are required and fewer alarms are generated 1), giving you more time for your patients. Configurable display HAMILTON-C3 display, providing an at-a-glance overview of the patient s status. 1 Beijers AJ. Intensive Care Med. 2014 May:40(5):752-3 2 Zhu F. Anesthesiology. 2015 Apr;122(4):832-40 10

4 2 3 1 The Ventilation Cockpit 1 Dynamic lung - Provides a real-time display of lung compliance, resistance, and breathing activity 5a 2 Direct access to the most important settings 3 The four most important monitoring parameters 4 5 Configurable waveforms for flow, pressure, and CO2, SpO2 Display options of the Ventilation Cockpit: a) ASV Graph b) Vent Status c) Trends (not shown) d) Loops (not shown) 5b Hamilton Medical HAMILTON-C3 11

What ASV does for us as therapists is it allows us to make sure that we are crafting the breath in the absolutely best possible way for that patient at that time. Craig Jolly, Adult Clinical Education Coordinator University Medical Center, Lubbock (TX), USA

Increased efficiency Integrated commercial considerations Ventilators are capital goods that need to be evaluated for cost efficiency. Factors including treatment costs and the use of human resources play an important role in this process. Assembled with an extensive standard equipment package that is easy to maintain, Hamilton Medical ventilators are an attractive investment with respect to purchase price and operating costs. Reduction of treatment costs Each eliminated ventilation day significantly reduces treatment costs on average by 1,500 USD. 1) It has been shown that the use of Hamilton Medical ventilators and ASV can reduce ventilation time. In addition, the ventilator is now available for the next patient much earlier. A shorter ventilation time also reduces the risk of ventilator associated pneumonia (VAP), which can result in costs of up to 57,000 USD per case. 2) Better use of human resources 1 Dasta JF et al. Critical Care Med. 2005 Jun;33:1266-71 2 Cocanour CS et al. Surg Infect. 2005 Spring;6:65-72 3 Iotti GA. Intensive Care Med. 2010 Aug;36(8):1371-9 4 Petter AH. Anesth Analg. 2003 Dec;97(6):1743-50 Hamilton Medical ventilators, along with ASV, can reduce the time needed for standard settings and alarm management while maintaining ventilation quality. 3), 4) This frees up time for other aspects of patient care. Thanks to the ease of operation, consistent operating concepts across devices, and the free e-learning offerings from Hamilton Medical, the effort for education and training is also reduced. Hamilton Medical HAMILTON-C3 13

Attention to detail On-screen help for alarm troubleshooting The HAMILTON-C3 helps troubleshooting with an integrated on-screen help system. Whenever there is a problem, the HAMILTON-C3 not only generates an alarm using the alarm lamp, sound, and message bar on the display, but also helps you identify where the problem is. As a result, you can immediately start with the troubleshooting. Customizable user interface You can configure the display layout with different waveforms, loops, trends, or intelligent panel graphics to suit your institution s needs and protocols. Nurses and clinicians can have their own preferred layout. Access the Monitoring window with the touch of a button at any time during active ventilation. Free and open e-learning on mechanical ventilation Join over 15,000 users on the Hamilton Medical College e-learning platform. It provides free and open e-learning modules on the basics of mechanical ventilation, as well as on Hamilton Medical products and features. Register now at college.hamilton-medical.com. For some modules, a certificate is issued upon successful completion. You can even receive Continuing Respiratory Care Education (CRCE) credits from the American Association of Respiratory Care (AARC) for some modules. Integrated on-screen help system for troubleshooting Clinicians using the e-learning platform 14

Neonatal ventilation Tidal volumes as low as 2 ml With the Neonatal option, the HAMILTON-C3 provides tidal volumes as low as 2 ml for effective, safe, and lung-protective ventilation even for the smallest patients. 1) The proximal flow sensor specifically developed for neonates precisely measures the pressure, volume, and flow directly at the infant s airway opening, ensuring the required trigger sensitivity. This provides improved synchronization and less work of breathing. Adaptive synchronization, even with uncuffed tubes Leaks are one of the issues encountered in the ventilation of neonates as a result of using uncuffed tubes. The IntelliTrig leak compensation function automatically adjusts the inspiratory and expiratory trigger sensitivity to leaks. This enables adaptive synchronization with the neonate s breathing pattern. ncpap-ps mode 1 Volume-targeted versus pressure-limited ventilation in the neonate (Review), 2011 Morley CJ The ncpap-ps mode is designed so that you set the desired CPAP and inspiratory pressure. Flow and pressure measurement recognizes patient efforts and supports each breath up to the desired inspiratory pressure. A backup rate guarantees a minimum patient ventilation. Flow is adjusted automatically based on patient conditions and leaks. ncpap-ps tries to avoid unintended peak pressures as well as apnea, enables highly efficient leak compensation, and helps to reduce oxygen consumption. Neonate with ncpap mask Neonatal ventilation with the HAMILTON-C3 Hamilton Medical HAMILTON-C3 15

Hamilton Medical Intelligent Ventilation since 1983 In 1983 Hamilton Medical was founded with a vision: To develop Intelligent Ventilation solutions that make life easier for patients in critical care and for the people who care for them. Today, Hamilton Medical is a leading manufacturer of critical care ventilation solutions for a wide variety of patient populations, applications, and environments. The right ventilation solution for every situation The ventilators from Hamilton Medical ventilate all of your patients: in the intensive care unit, during an MRI procedure, and in all transport situations, from the neonate to the adult. Each of these ventilators is equipped with the same standardized user interface and uses the same Intelligent Ventilation technologies. This enables Hamilton Medical ventilators to help you to Increase the comfort and safety of your patients Make life easier for the caregivers Increase efficiency and return on investment ELO20160206N.01 Specifications are subject to change without notice. ASV is a trademark of Hamilton Medical. Not all options are available in all countries. 2016 Hamilton Medical AG. Hamilton Medical, Inc. 4990 Energy Way, Reno, NV 89502 +1 800 426 6331 info@hamilton-medical.com www.hamilton-medical.com