arxiv: v1 [physics.ins-det] 4 May 2016

Similar documents
Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

Analysis of RPC Performance with Different Gas Mixture

arxiv: v1 [hep-ex] 18 Sep 2012

arxiv: v1 [physics.ins-det] 16 Aug 2014

arxiv: v1 [physics.ins-det] 6 May 2016

ATLAS RPC QA results at INFN Lecce

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

GAS ANALYSIS AND MONITORING SYSTEMS

Long term stability tests of INO RPC prototypes

PERFORMANCE OF THE GAS GAIN MONITORING

Performance of a triple-gem detector for high rate charged particle triggering

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Development of small, easy to build and low gas consumming timing RPCs

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Study of Mixed Gas Flow Pattern Inside RPC

Kinetic-Molecular Theory

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

This test shall be carried out on all vehicles equipped with open type traction batteries.

Impact Fatigue on Suction Valve Reed: New Experimental Approach

Gas Pressure. Pressure is the force exerted per unit area by gas molecules as they strike the surfaces around them.

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

GEA FOR ADVANCED STRUCTURAL DYNAMIC ANALYSIS

Detecting sound wave of bubbles produced in a boiling liquid

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

SAFE AND ENVIRONMENTALLY FRIENDLY

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

AN EXPERIMENTAL AND ANALYTICAL STUDY OF PLASMA CLOSING SWITCHES FILLED WITH ENVIRONMENTALLY FRIENDLY GASES

Pressure Strength Test Requirements for Hermetic Refrigerant Compressor Housings Using Fatigue Analysis

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

Dissolved Oxygen Guide

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

Operation manual Oxygen sensor

A high-sensitivity large volume cryogenic detector for radon in gas

Improve Process Reliability

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

CHEM 3351 Physical Chemistry I, Fall 2017

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Design and Construction of a GEM-TPC Prototype for R&D Purposes

Lab 1. Adiabatic and reversible compression of a gas

LGWP & HC Refrigerants Solubility Tests Performed in Running Scroll Compressor

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

The TOTEM Gas System

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

MIL-STD-883G METHOD

CHEMISTRY - CLUTCH CH.5 - GASES.

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

Name /74. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Chapter 12. Properties of Gases

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

An Innovative Solution for Water Bottling Using PET

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

LUMAZOTE T ECHNICAL BRO CHU RE

Innovation Electrical Industry

End of Chapter Exercises

Multifunctional Screw Compressor Rotors

Chemistry A Molecular Approach. Fourth Edition. Chapter 5. Gases. Copyright 2017, 2014, 2011 Pearson Education, Inc. All Rights Reserved

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Ball Beating Lubrication in Refrigetation Compressors

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Flow in a shock tube

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Pedestrian crossings survey in Europe

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Phase Changes * OpenStax

Introductory Lab: Vacuum Methods

Inprocess Operator Training Programme

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

MITIGATE GAS COMBUSTION IN CASE OF INTERNAL ARC

CORESTA RECOMMENDED METHOD N 6

LEAP CO 2 Laboratory CO 2 mixtures test facility

ISO INTERNATIONAL STANDARD

To convert to millimeters of mercury, we derive a unit factor related to the equivalent relationship 29.9 in. Hg = 760 mm Hg.

Application Note AN-107

Experience with the ZEUS central tracking detector

QUALIFICATION OF SUB-ATMOSPHERIC PRESSURE SENSORS FOR THE CRYOMAGNET BAYONET HEAT EXCHANGERS OF THE LARGE HADRON COLLIDER

Investigation of Suction Process of Scroll Compressors

The Experts in Vacuum Solutions

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

End of Chapter Exercises

Chapter 11 Waves. Waves transport energy without transporting matter. The intensity is the average power per unit area. It is measured in W/m 2.

Badan Jadrowych Nuclear Research Institute. Report INR No. 739/XIX/D CERN LIBRARIES, GENEVA CM-P Differential Recombination Chamber

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Worksheet 12 - Partial Pressures and the Kinetic Molecular Theory of Gases

Fail Operational Controls for an Independent Metering Valve

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Transcription:

Preprint typeset in JINST style - HYPER VERSION arxiv:1605.01691v1 [physics.ins-det] 4 May 2016 Eco-friendly gas mixtures for Resistive Plate Chambers based on Tetrafluoropropene and Helium M. Abbrescia 1, L. Benussi 2, S. Bianco 2, M. Ferrini 3, S. Muhammad 3, L. Passamonti 2, D. Pierluigi 2, D. Piccolo 2, F. Primavera 2, A. Russo 2, G. Saviano 3 1 INFN and Dipartimento di Fisica, Università di Bari, Bari, Italy 2 INFN Laboratori Nazionali di Frascati, Frascati (RM), Italy 3 INFN Laboratori Nazionali di Frascati and Facoltá di Ingegneria Roma1 (RM), Italy E-mail: marcello.abbrescia@ba.infn.it, davide.piccolo@lnf.infn.it ABSTRACT: Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems of the LHC experiments will be most probably phased out of production in the coming years. Identifying possible replacements with the adequate characteristics requires an intense R&D, which was recently started, also in collaborations across the various experiments. Possible candidates have been proposed and are thoroughly investigated. Some tests on one of the most promising candidate - HFO-1234ze, an allotropic form of tetrafluoropropane- have already been reported. Here an innovative approach, based on the use of Helium, to solve the problems related to the too elevate operating voltage of HFO-1234ze based gas mixtures, is discussed and the relative first results are shown. KEYWORDS: tetrafluoroethane, tetrafluoropropane, helium, eco-friendly gas mixtures, Global Warming Power.

Contents 1. Introduction 1 2. Experimental set-up 3 3. Results from Helium and Tetrafluoropropane based gas mixtures 4 4. Conclusions 6 1. Introduction Resistive Plate Chambers (RPCs in the following) were invented at the beginning of 1980s and originally thought to be operated in streamer mode, using Argon based gas mixtures [1]. Later on, when they were proposed for the experiments at Large Hadron Collider, the rate limitation intrinsic to operate these devices in streamer mode was overcome by passing to some kind of "saturated" avalanche mode, obtained by filling them with Freon based gas mixtures and transferring part of the needed amplification from the gas to the front-end electronics [2] [3]. The first Freon used in RPC, CF 3 Br (at first added just in small percentages to the Argon based mixtures, and later on used as the main component in the first attempts towards the avalanche mode) was soon prohibited due to regulations about environment protection, since it was known to damage the ozone atmospheric layer. Tetrafluoroethane C 2 H 2 F 4 (commercially known as R-1234a), characterized by a negligible ozone depletion power, was introduced to replace it, and soon adopted by all LHC experiments as the main component of their RPC gas mixtures. It was successfully used throughout all R&D tests, the experiments commissioning phase, Run-1 and it is currently used during Run-2. RPCs filled with it contributed to the Higgs boson and other important discoveries. Nevertheless, C 2 H 2 F 4 is characterized by a Global Warming Power (GWP) around 1430 (the reference being the one of carbon dioxide GWP(CO 2 )=1), and recent regulations from the European Community derived from the adoption of the Kyoto protocol, prohibit for many applications the use of gas mixtures with a GWP>150. Even if scientific laboratories are explicitly excluded from this prohibition, CERN is pushing the LHC experiments collaborations to investigate for possible replacements of C 2 H 2 F 4 with other more eco-friendly gases. This has led to many R&D studies, sometimes coordinated across the different experiments. This was necessary, since finding a new RPC gas mixture is quite complicated, due to the many possible candidates, many possible combinations and different percentages that could in principle be used and need to be tested. 1

One of the possible ideas to follow, proposed some time ago by one of the authors of this paper [4], relies on finding the molecule most similar to C 2 H 4 F 4 characterized by a low enough GWP. Of course, this is not sufficient to assure that the new gas would be suitable for RPC operation, and the corresponding tests to assure that RPCs filled with this mixture provide the necessary efficiency, time resolution, rate capability, aging tolerance, are anyhow needed. On the other hand, the criteria proposed above seem to be quite reasonable to make educated guesses about possible candidates in the huge amount of possibilities. A molecule quite similar to C 2 H 2 F 4 but characterized with a GWP<150 is tetrafluoropropane, C 3 H 2 F 4 ; the two molecules, essentially, differ by a one single atom (one carbon atom more with respect to the tetrafluorethane). Tetrafluoropropane also comes in two allotropic forms, commercially indicated as HFO-1234yf and HFO-1234ze. Both gases satisfy the requirement about their GWP, being GWP(HFO-1234yf)=4, and GWP(HFO-1234ze)=6. However, one of the two, HFO-1234yf, is reported to be mildly flammable, and this induces to start testing the other. Both of them are quite expensive at the moment (around ten times the cost of R-1234a), but it must be stressed that R-1234a is extensively used as refrigerator, for instance in automobiles refrigerating plants; once that it will be phased out, HFO-1234ze is one of the most interesting candidates to replace it, and this would let us suppose that its price will be progressively decreasing in the coming years. Tests on mixtures obtained replacing increasing fractions of tetrafluoroetane with tetrafluoropropane have already been performed, and are still in progress [5] [6]. Basically, they demonstrate that HFO-1234ze based gas mixtures could be a promising solution validating the proposal made above, but with the main drawback that the operating voltage is shifted toward much higher values with respect to tetrafluoroethane based gas mixtures. 2 mm gap RPCs of the type used in CMS and ATLAS filled with HFO gas mixtures, for instance, would typically operate at operating voltage much higher than 10 kv, the exact value depending on the precise mixture composition. This is related to the fact that HFO-1234ze has an effective first Townsend coefficient lower, at the same electric field, with respect to tetrafluroethane. In principle, this would not be a problem. However, the present RPC systems of the LHC experiments are designed to operate at voltages lower than 10 kv (in particular in terms of high voltage cables and connectors), therefore it would be interesting to identify a gas mixture with the requirement -in addition to the ones already cited- that the present RPCs could operate at voltages lower than 10 kv. This could be obtained adding Helium to HFO-1234ze based gas mixtures. Helium is a gas characterized by no vibrational and rotational degrees of freedom, and with a large first ionization energy, being around 24.6 ev, much higher than tetrafluoroethane or tetrafluoropropane. This has the consequence that, in a mixture composed mainly by tetrafluoroethane or tetrafluoropropane, most ionising interactions take place on these two gases and not on Helium, and that when the average energy of the electron avalanche is not large enough, most electron interactions with Helium atoms are essentially elastic. In this approximation Helium does not take any part in the avalanche process, but behaves just as a "space holder" in the gas volume; as a consequence the partial pressure of the "active" gas mixture, in this case composed essentially by tetrafluoroethane or tetrafluoropropane, is reduced by an amount corresponding to the fraction of Helium in the mixture. It is well know that a reduction in the pressure of the gas mixture has the consequence to reduce 2

also the operating voltage of RPCs (or other gaseous detectors), since it increases the average mean free path, and consequently the first effective Townsend coefficient. Roughly, gas parameters are the same for the same value of the E/d ratio, where E is the electric field strength and d in the gas density [7] [8]. So, in presence of gas mixtures characterized by a high operating voltage, it is a natural idea to add a fraction of Helium to reduce their partial pressure and lower the operating voltage while the performance keeps stable. This has already been proved some years ago [9], with quite encouraging results. In this paper, the first results of tests using HFO-124ze based gas mixtures, to which some fraction of Helium has been added, will be reported. 2. Experimental set-up This work was performed using the very same experimental set-up already employed to obtain the results described in [5]; therefore just its main characteristics will be reported here. It consists of twelve bakelite 50 50 cm 2 single-gap Resistive Plate Chambers located at the Frascati National Laboratories of the Italian Institute for Nuclear Physics, and arranged on top of each other in a telescope for cosmic rays. Each chamber is read-out by means of two copper pads glued on the opposite external sides of the electrode plates. The pads are read out by a custom circuit which algebraically subtracts the signals coming from the two gaps; since these are of opposite polarities, this eliminates the coherent noise and adds up the signals induced by the charges moving inside the gas gap, increasing significantly the signal to noise ratio. The trigger is provided by two scintillators located on the top and bottom of the RPC stack; given the measured 1 Hz average trigger rate, 1000 events are collected in about 20 minutes. Signals from the pads are digitalized by means of a Lecroy oscilloscope, with a 1 GHz bandwidth; for each signals 5 Gsamples are taken per event, covering a time span of about 1 µs. For these tests, just two RPCs were read out, both flushed with the gas mixtures under study. One of them, however, was kept at fixed voltage and used as an additional off-line trigger, to furtherly reduce trigger accidentals. For the RPC under test, measurements were taken at different effective High Voltages (henceforth labelled as HV e f f ), using the standard formula HV e f f = HV appl p 0 /p T/T 0 derived from [7] to relate it to the applied voltage HV appl, where, in this case using p 0 = 990 mbar and T 0 = 293.15 K have been used as reference pressure and temperature respectively. In order to reduce the environmental noise picked up from the system, a 200 MHz filter was connected in input to the oscilloscope; this, in addition to using pad read-out electrodes, has the effect to increase the signal rise time, slightly worsening the measured time resolution; the measured induced charge, on the contrary, being an integral quantity, should not be affected. For analysis purposes, waveforms acquired by means of the oscilloscope and stored, are divided into four "regions". The region of 200 ns centerd around the trigger is the "signal region", used to measure signal characteristics. The 50 ns region before it, where signals are absent, is the "baseline region", and it is used to measure the average baseline to be subtracted to the measured values taken in the "signal region". In addition, the 200 ns before the "baseline window" is called 3

Figure 1. Efficiency (solid line) and streamer probability (dashed line) as a function of effective voltage HV e f f, for tetrafluoropropene/iso-buthane/helium based gas mixtures the "control region" and is used to check the width of the charge distribution and of the peak voltage, in absence of signal, to define the correct threshold to identify RPC signals. The 200 ns after the "signal region" is called "delayed region" and is used to search for signals delayed with respect to the main one that could be related to streamers. Induced charge is computed by integrating the waveform -after baseline subtraction- in the "signal window", and dividing the result by the oscilloscope input impedance. To distinguish RPC signals from noise, it is required that they are characterized by an integrated charge greater than 300 fc, which is quite close to the usual thresholds used for the RPC in CMS and ATLAS. In addition the signals are required to be higher than a minimum voltage of 0.4 mv, in absolute value. A streamer is defined as a signal characterized by an integrated charge larger than 40 pc in the 400 ns time window defined by the "signal" plus "delayed" regions. Finally the time resolution is obtained by measuring the time the signals from the two RPCs cross over a threshold of -0.8 mv and plotting the difference. The time resolution of the trigger RPC is deduced looking at the time difference distribution taken when both trigger and test RPCs have the same effective voltage. Assuming that at the same voltage both RPCs have the same resolution, the time resolution of the trigger RPC is deduced dividing by 2 the sigma of the difference distribution. Finally the time resolution of the test RPC at different applied voltages is extracted subtracting in quadrature the trigger RPC resolution to the measured sigma of the time differences at each voltage. 3. Results from Helium and Tetrafluoropropane based gas mixtures In this section the first results of tests using HFO based gas mixtures to which some fraction of Helium has been added are reported. In order to validate the Helium power to reduce the working 4

Figure 2. Integrated induced charge as a function of the effective voltage HV e f f, for tetrafluoropropene/isobuthane/helium based gas mixtures voltage, we started from a gas mixture made from 65 % of tetrafluoroethane, 30 % of tetrafluoropropane and 5 % of iso-buthane. With this gas mixture the working voltage is around 12 kv. Note that this gas mixture does not fullfill the requirement GWP<150 (essentially because of the presence of C 2 H 2 F 4, nevertheless it is useful to understand the role of the various gases with respect to the operating voltae. To this gas mixture increasing fractions of Helium were added; also the ratio between tetrafluroethane and tetrafluoropropane was modified. The effects of adding Helium is clearly visible in figure 1. The efficiency (in solid line) and the streamer probability (in dashed line) are shown in the plot as a function of the effective voltage HV e f f, as defined in the previous section. The black line refers to the gas mixture used as a starting point, composed by 65 % of R-134a, 30 % of HFO-1234ze and 5 % of iso-buthane; the red line refers to the same gas mixture, but with the addition of 20 % of Helium, while keeping constant the ratios among R134a, HFO-1234ze and iso-buthane. Adding 20 % of Helium has the effect to shift the efficiency curves toward lower values of HV e f f, of an amount of around 2 kv, as expected. In the same plot, the green line shows the effect of increasing the relative fraction of HFO- 1234ze (and correspondigly reducing the one of R-134a), while keeping Helium and iso-buthane to 20 and 4 % respectively. Finally the Helium fraction was increased to 40 %, while keeping iso-buthane at 5 % and completed the mixture with HFO-1234ze, and this is shown by the blue line. This last mixture (shown with blue trianlges upside-down in the plot) is particularly interesting, since it is an eco-friendly gas mixture (with a GWP<150), and the 2 mm RPC used in this test were able to operate at a working voltage around 10 kv. Unfortunately, in this case, the range of voltage the RPCs could be operated is quite narrow, since the streamer probability exceeds 40 % when 5

Figure 3. Time resolution as a function of the effective voltage HV e f f, for tetrafluoropropene/isobuthane/helium based gas mixtures efficiency is still below 90 %. The total induced charge and the time resolution as a function of the effective voltage HV e f f for the gas mixtures tested are shown in Figures 2 and 3 respectively. Due to the double pad readout used on the RPC used, the total induced charge should be divided by a factor about 2 in order to compare these results with devices in which the readout is done with a single pad or strips. In order to reduce the streamer fraction with these gas mixtures, the effect of the addition of small quantities of SF 6 was studied. This is not a drawback, since SF 6 is used is so small quantities, that the overall GWP of the gas mixture is still under the 150 limit value. The efficiency, streamer probability, total charge and time resolution as a function of effective voltage for Helium, HFO-1234ze, iso-buthane and SF 6 based gas mixtures are shown in Figures 4, 5 and 6 respectively. The presence of SF 6 fractions of the order of 1-1.5 % has the effect to limt the streamer probability to values below 20 % at efficienies greater than 90 % and represent a good starting point in the direction of an ecological gas mixtures to be used in the hostile environment of the LHC experiments. The performance of the gas mixtures tested are summarized in table 1, which reports the gas mixture, the effective voltage at 90 % efficiency (HV 90 ), the streamer probability, the total charge and the time resolution at HV 90. 4. Conclusions The replacement of gases characterized by a Global Warming Power > 150 in the gas mixtures presently used in RPCs is one of the priorities in the R&D on gaseous detectors in this period. Some of them could go out of production in the coming years, while the community has to assure 6

Figure 4. Efficiency (solid line) and streamer probability (dashed line) as a function of effective voltage HV e f f, for SF 6 /tetrafluoropropene/iso-buthane/helium based gas mixtures Figure 5. Integrated induced charge as a function of the effective voltage HV e f f, for SF 6 /tetrafluoropropene/iso-buthane/helium based gas mixtures that the RPCs installed at the LHC experiments continue operating with a stable performance up to the end of the High Luminosity phase of LHC, foreseen to be around 2030s. The most natural replacement of tetrafluoroethane, the main component of the gas mixture 7

Figure 6. Time resolution as a function of the effective voltage, for SF 6 /tetrafluoropropene/isobuthane/helium based gas mixtures Table 1. effective voltage at 90% efficiency (HV 90 ), streamer probability, total charge and time resolution at HV 90 for the gas mixtures investigated in this study Gas mixture HV 90 (kv) Strm. prob. (%) 2 Q tot (pc) σ t (ns) HFOze-iC 4 H 10 -R134a (30/5/65) 11.6 0.7 4 2 HFOze-iC 4 H 10 -R134a-He (24/4/52/20) 9.8 1.2 6 2 HFOze-iC 4 H 10 -R134a-He (38/4/38/20) 10.8 2 7 2.4 HFOze-iC 4 H 10 -He (59/4/37) 10.4 28 36 1.7 HFOze-iC 4 H 10 -He-SF 6 (60/4.7/36.6/0.7) 11 1 7 2.4 HFOze-iC 4 H 10 -He-SF 6 (54/3.7/41/1.3) 10.5 3 8 2.2 standardly used in the RPC of the two main LHC experiments, is tetrafluoropropane, and many studies about its behavior are currently being carried on. In this paper, some tests have been presented, demonstrating the suitability of this gas as a possible component of the future mixtures for RPCs, characterized by GWP < 150. However, its operating voltage is higher that tetrafluoroetane based gas mixtures, in particular higher than 10 kv, and this would require the use of specific electrical components, with the corresponding additional costs. The solution could be represented by the addition of some fraction of Helium to these new gas mixtures, which has the effect of reducing the operating voltage. Here the first tests using these new gas mixtures have been reported, which demonstrate the effectiveness of this approach. More tests are needed to find the optimal proportions these components have to be mixed, and this represents the plan for the future. 8

References [1] R. Santonico et al., Development of Resistive Plate Counters, Nucl. Instr. and Meth. 187, 377-390 (1981) [2] R. Cardarelli et al., Performance of a resistive plate chamber operating with pure CF 3 Br, Nucl. Instr. and Meth. 333, 399-403 (1993) [3] P. Camarri et al., Streamer suppression with SF 6 in RPCs operated in avalanche mode, Nucl. Instr. and Meth. A 414, 317-324 (1998) [4] M. Abbrescia, Possible replacemente of C 2 H 2 HF 4 in CMS/RPC gas mixture, internal talk to the CMS collaboration [5] L. Benussi et al., A study of HFO-1234ze (1,3,3,3-Tetrafluoropropene) as an eco-friendly replacement in RPC detectors, ArXiv:1505.01648v1 [physics.ins-det] (2014). [6] R. Cardarelli et al., New RPC gas mixtures for large area apparatuses, JINST 9, C11003 (2014) [7] M. Abbrescia et al., Resistive Plate Chamber performances at cosmic rays fluxes, Nucl. Instr. and Meth. 359, 603-609 (1995) [8] M. Abbrescia et al., Resistive Plate Chamber performances at low pressure, Nucl. Instr. and Meth. 394, 341-348 (1997) [9] M. Abbrescia et al., New gas mixtures for Resistive Plate Chambers operated in avalanche mode, Nucl. Instr. and Meth. A 661, S190-S193 (2012) 9