DCA Modified Alkyd Conformal Coating (SCC3)

Similar documents
SCC3 Conformal Coating

XIAMETER RSN-0997 Resin

PSR-4000 HFX Series (UL Name: PSR-4000DE / CA-40HF)

44GN098 Water Reducible High Performance Epoxy Primer

10P20-13 High Solids Primer

0TECHNICAL DATA SHEET

SOLAR ENERGY. solutions. adhesives, sealants, and Potting encapsulants For solar energy applications

Heresite VR-514 T E C H N I C A L D A T A S H E E T

Mix ratio (by volume): 44GN011 (base component) 44GN011CAT (catalyst component) Reducer (Distilled or Deionized water) MCS0200 Grade E

Eco-Prime EWDE072 Military Water-Borne Epoxy Primer

3M Thermally Conductive Epoxy Adhesive TC-2810

44GN008A Water Reducible Type II Epoxy Primer

EC75/C9071 Epoxy Clear Coat. EC75/C9071 (Base) ACT65 (Activator) 0.33 part (spray application)

TECHNICAL DATA SHEET 513X408B. DeSoto 513X408B Military Water-Borne Primer. Product Description. Components. Specifications

EC96 HS Epoxy Topcoat. 1 part. ACT197 (Activator) near matt. 1 part

TECHNICAL DATA SHEET CA7040. CA7040 HS CF Polyurethane Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

TECHNICAL DATA SHEET

PSR-9000 FXT Series (UL Name: PSR-9000AC/CA-90AC)

AkzoNobel Aerospace Coatings. Primerr. Product Group. Epoxy primer. Characteristics Product Information. resistance. Components * TR-114. permits.

PR219 Epoxy Primer Undercoat

TECTYL 1422S APPLICATION PROCEDURES AND TROUBLESHOOTING GUIDE

44GN072 Water Reducible Low Density Epoxy Primer

Eco-Prime EEAE154 Military Epoxy Primer

SHELF LIFE. Appearance Color 1 (Gardner) Pot life 21 C (70 F) Increased by 15-60% 5 Thin Film Set Time 21 C Increased by % 5

Mix ratio (by volume): 513K009 (base component) (activator component)

02GN093 Chrome-Free Epoxy Primer. Kit size 02GN093 base 02GN093CAT Gallon 96oz/2.84L 32oz/946mL Quart 24oz/710mL 8oz/237mL

Desoprime HS CA7233 Military Epoxy Primer

two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

Compatible with Desothane HS topcoats Excellent adhesion and corrosion resistance Service temperature -54 C to 177 C (-65 F to 350 F)

Mix ratio (by volume): 519X303 (base component) 910X357 (activator component) 020X324 (thinner component)

TECHNICAL DATA SHEET 02GN070A. 02GN070A Epoxy Primer. Product Description. Components. Specifications

Technical Data Megacote

TECHNICAL DATA SHEET EC75. EC75 Epoxy Topcoat. Product Description. Components. Specifications

As Supplied : 1.67 lbs/gal (200 g/l) Plasite Thinner #71 : 10% by volume 2.18 lbs/gal (261 g/l)

TECHNICAL DATA SHEET 44Y Y032 Water Reducible Epoxy Primer. Product Description. Components. Specifications

Two coats are normally recommended. Some service may require mils DFT

Aerodur 2111 Chrome Free Primer

Mix ratio (by volume): 515K011 (base component) (activator component) Grade A A8B91-S LES 1091 BAMS Grade A

TECHNICAL DATA SHEET 515X410. DeSoto 515X410 Military Epoxy Polyamide Primer. Product Description. Components. Specifications

Super Koropon 515X333 fluid resistant primer is a chemical and solvent resistant epoxy coating used in areas exposed to hydraulic fluid.

TECHNICAL DATA SHEET 528X310. DeSoto 528X310 Conductive Coating. Product Description. Components. Specifications

Property Test/Standard Description

Desoprime HS CA7422 Chrome-Free Epoxy Primer

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

5541/9000 UV Resistant Varnish Semi Gloss. 0701/9000 (Activator) 5541/9000 meets the requirements of : AIMS

PAC33NV Polyurethane Primer. Mix Ratio (by volume) 4359/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0477/9000 (Thinner) 3 parts

*RTS not recommended for immersion service. Do not exceed 10 mils in a single coat (without additives)

PAC33 Polyurethane Primer. Mix Ratio (by volume) 4355/3600 (Base) 5 parts 0701/9000 (Activator) 1 part 0433/9000 (Thinner) 4-5 parts

Desoprime HS 533K004 Military Epoxy Polyamide Primer

PACKAGING: Component A W-THANE HBA CD (2,7 L) Component B W-THANE 5057 CD (0,9 L)

Epoxy Curing Agents and Modifiers

Mix ratio (by volume): (base component) (activator component)

ITW RANSBURG REA AND VECTOR

Self-priming. May be applied over most generic types of coatings.

PSR-4000 MP (UL Name: PSR-4000MP / CA-40MP)

PSR-4000BN Series (UL Name: PSR-4000BN / CA-40 BN)

Carboguard 893 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

S0200V. Product Data Sheet August Primecoat P FOR PROFESSIONAL USE ONLY. Product Description

HR39/801 Heat Resistant Topcoat Matt Black. HR39/801 is a heat resistant topcoat suitable for interior and exterior use.

*Valid if manufactured at a certified location. Light Grey (0700), White (0800), and Light Blue (0100). Colors are unmatched

PSR-4000 LDI (US) (UL Name: PSR-4000 JA / CA-40 JA)

Desofill HS CA8620G Sanding Surfacer. Mix ratio (by volume): CA8620G (base component) CA8000B (activator component) CA8000C (thinner component)

Desoprime HS CA7755 with BE Activator

ICYNENE INSTALLATION INSTRUCTIONS

two component solvent free amine cured phenolic epoxy coating

Desothane HS CA9800 Military Advanced Performance Topcoat

TECHNICAL DATASHEET CARAPACE EMP110 W- LED

PSR-4000BN DI Colors (UL Name: PSR-4000BN / CA-40 BN)

Hardener: at least 24 months when stored cool and dry

Surf Clear EVO Epoxy system for surfboards

Mix ratio (by volume for base and activator): CA8022/B7022 (base component) CA8020DX (activator component) 920K058 (pumice component)

Polidura Glossy PU Topcoat Component A: 6103 Component B: 6199

Desothane CA8311 HS Polyurethane Topcoat Matt

The Application Guide offers product details and recommended practices for the use of the product.

Before application, test the atmospheric conditions in the vicinity of the substrate for the dew formation according to ISO

Designed for both global and coastal trade. Recommended for exposure to both sea and fresh water during newbuilding outfitting. Antifouling.

COATINGS SPRAY GUIDE Urethane 520

Desoprime HS CA7700 with B Activator

TECHNICAL DATA SHEET PP404. PP404 Epoxide Primer. Product Description. Components. Specifications. Surface Preparation and Pretreatment

ProAir Clear LV 2 Pack

CV117 Hydraulic Fluid Resistant PU Lacquer. ACT34 (Activator) NOTE: No thinner is required for brush application

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 33 C calculated VOC-USA / VOC Hong Kong EPA Method 24

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong

PR143 (ACT 149) Epoxy Primer

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 35 C calculated IED (2010/75/EU) (theoretical)

5014 PU Surfacer. Highly flexible Water resistant Good fluid resistance including phosphate ester hydraulic fluids Transparent to ultrasound & radar

Mix ratio (by volume): 513X384 (base component) 910X456 (activator component)

DFT in excess of 8.0 mils per coat is not recommended.

DP40 is a versatile 2K Epoxy Surfacer. It is light grey in colour, chromate-free and has good corrosion resistance over bare metal.

Desothane HS CA8925 buffable stain resistant topcoats are high solids topcoats used to protect the exterior of an aircraft.

PRODUCT SPECIFICATION

Cylinder Adhesive for Geotextile Seaming

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 36 C calculated VOC-US/Hong Kong US EPA method 24 (tested)

GACOFLEX TWO-COMPONENT LIQUID POLYURETHANE SPRAY GUIDE UA-60, U-64, UB-64, UA-7090, U-66

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 55 C VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Approved. Marine: Exterior areas, specially designed for outside hull, may be used on superstructure, decks and other external areas.

The Application Guide offers product details and recommended practices for the use of the product.

Transcription:

Page 1 DCA Modified Alkyd Conformal Coating (SCC3) DCA is a flexible, transparent and unique modified alkyd conformal coating specifically designed for the protection of electronic circuitry. It has been formulated to meet the highest defence standards in both Europe and the United States. It holds approvals including the British Ministry of Defence (MOD) DEF-STAN 59/47 Issue 4, and Underwriters Laboratories UL746E-QMJU2. Can be cured at ambient or elevated temperatures; optimum properties achieved by heat curing Heat-cured coating is resistant to many solvents used within aerospace and automotive industries Suitable for use at temperature extremes; very wide operating temperature range Can be reworked using specialist removal product, Electrolube CCRG Approvals RoHS-2 Compliant (2011/65/EU): Yes UL746E-QMJU2: Approved File Number: E138403 DEF-STAN 59/47 (Issue 4): Yes IPC-CC-830: Meets approval NATO Stock Numbers: 6850996642823 (DCA05L) 6850992530057 (DCA200H) Liquid Properties Appearance: Clear Pale Straw Density @ 20 C (g/ml): 0.97 (Bulk), 0.78 (Aerosol) VOC Content: 63% (Bulk) 73% (Aerosol) Flash Point: 27 C (Bulk), <23 C (Aerosol) Solids content: 37% (Bulk), 27% (Aerosol) Viscosity @ 20 C (mpa s): 180-250 (Bulk) Touch Dry: 50-55 minutes Recommended Curing Schedule*: 2 Hours @ 20 C followed by: 2-24 Hours @ 90 C to 120 C *(Maximum Solvent Resistance Achieved @ 120 C; Ambient Curing Schedule: 24 Hours @ 20-25 C) Coverage @ 25 µm: 14.8m² per litre (Bulk), 2.16m² (200ml Aerosol) Cured Film Coating Colour: Colourless Operating Temperature Range: -70 C to +200 C Flammability: UL94 V-1 Thermal Cycling (IPC-CC-830): Meets approval Coefficient of Expansion: 90ppm Dielectric Strength: 90 kv/mm Dielectric Constant: 3.95 @ 1 MHz Insulation Resistance: 1 x 10 15 Ohm (DEF-STAN 59/47) Dissipation Factor (@1 MHz, 25 C): 0.037 Moisture Resistance (IPC-CC-830): Meets approval

Page 2 Description Packaging Order Code Shelf Life DCA Conformal Coating 200ml Aerosol DCA200ML 36 Months 1 Litre Bulk DCA01L 48 Months 5 Litre Bulk DCA05L 48 Months Conformal Coating Thinners 1 Litre DCT01L 36 Months 5 Litre Bulk DCT05L 36 Months Conformal Coating Removal Gel 1 Litre Bulk CCRG01L 36 Months Directions for Use DCA can be sprayed, dipped or brushed. The thickness of the coating depends on the method of application (typically 25-75 microns). Temperatures of less than 16 C or relative humidity in excess of 75% are unsuitable for the application of DCA. As is the case for all solvent based conformal coatings, adequate extraction should be used (refer to MSDS for further information). Substrates should be thoroughly cleaned before coating. This is required to ensure that satisfactory adhesion to the substrate is achieved. Also, all flux residues must be removed as they may become corrosive if left on the PCB. Electrolube manufacture a range of cleaning products using both hydrocarbon solvent and aqueous technology. Electrolube cleaning products produce results within Military specification. Spraying Bulk DCA needs to be diluted with the appropriate thinners (DCT) before spraying. The optimum viscosity to give coating quality and thickness depends on the spray equipment and conditions, but normally a dilution ratio of 2:1 (DCA:DCT) is required. Suitable spray viscosity is typically 50-80mPa s. If bulk coating material has been agitated, allow to stand until air bubbles have dispersed. DCA is suitable both for use in manual spray guns and selective coating equipment. The selected nozzle should enable a suitable even spray to be applied in addition to suiting the prevailing viscosity. The normal spray gun pressure required is 274 to 413 kpa (40-60 lbs/sq.inch). After spraying, the boards should be placed in an air-circulating drying cabinet following the curing schedule highlighted on page 4/5.

Viscosity (mpa s) Viscosity (mpa s) Page 3 Viscosity Change with Temperature - DCA 250 200 150 100 50 0 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Temperature (⁰C) Viscosity Chart - DCA:DCT 250 200 150 100 50 0 1:0 20:1 10:1 5:1 2:1 1:1 1:1.5 1:2 1:2.5 1:3 Mix Ratio - DCA:DCT Spraying - Aerosol When applying DCA in aerosol form care must be taken to ensure the can is not shaken before use. Shaking the can will introduce excessive air bubbles and will give a poor coating finish. The can should be held at 45, and 200mm from the substrate to be coated. The valve should then be depressed when the can is pointing slightly off target and moved at about 100mm/s across the target. To ensure the best coating results are achieved try to use a smooth sweeping motion with small overlap for successive rows.

Page 4 To ensure penetration of the coating beneath the components and in confined spaces, spray the assembly from all directions to give an even coating. After spraying, the boards should be placed in an air-circulating drying cabinet following the curing schedule highlighted on page 4/5. Dip Coating Ensure that the coating material in the container has been agitated thoroughly and has been allowed to stand for at least 2 hours for all the air bubbles to disperse. Conformal Coating Thinners (DCT) should be used to keep the DCA coating at a suitable viscosity for dipping (180 250mPa s @ 20 C). DCT is added periodically as the solvent evaporates. The viscosity should be checked using a viscosity meter or "flow cup". The board assemblies should be immersed in the DCA dipping tank in the vertical position, or at an angle as close to the vertical as possible. Connectors should not be immersed in the liquid unless they are very carefully masked. Electrolube Peelable Coating Masks (PCM/PCS) are ideal for this application. Leave submerged for approximately 10 seconds until the air bubbles have dispersed. The board or boards should then be withdrawn slowly (1 to 2s/mm) so that an even film covers the surface. After withdrawing, the boards should be left to drain over the tank or drip tray until the majority of residual coating has left the surface. After the draining operation is complete, the boards should be placed in an air-circulating drying cabinet following the curing schedule (shown below). Brushing Ensure that the coating material has been agitated thoroughly and has been allowed to settle for at least 2 hours. The coating should be kept at ambient temperature. When the brushing operation is complete, the boards should be placed in an air-circulating drying cabinet following the curing schedule (shown below). Drying Times and Curing Conditions The properties gained from DCA are dependent on the curing schedule employed. It is essential that the coating be allowed a minimum of two hours drying time at ambient temperature prior to any heat curing. This is necessary to allow the solvent system to evaporate. Ambient Ambient curing is via solvent evaporation only. Eliminating the heat curing step will reduce solvent resistance. Other properties, such as resistance to humid and corrosive environments, may also reduce but still meet the requirements of many industry standards. Coated boards should be left at room temperature for the solvent to evaporate; extraction is required in the curing area.

Page 5 Commercial Military Most commercial users will gain satisfactory performance from this coating by curing for two hours at 90 C after the two-hour ambient cure. This will give limited resistance to solvents. If the assemblies are to be used under conditions of high temperature or be exposed to extremes of thermal cycling, the coating should be cured for 12 hours at ambient followed by 24 hours at 90 C. For maximum solvent resistance cure at 2 hours at ambient following by 24 hours @ 120 C. This curing schedule will give resistance to the more aggressive solvents. It is recommended that the coating be thoroughly cured on circuits, which have design areas of very high impedance that require adjustment after application. Inspection DCA contains a UV trace, which allows inspection of the PCB after coating to ensure complete and even coverage; the stronger the reflected UV light, the thicker the coating layer is. UV light in the region of 375nm should be used for inspection. Revision 4: Oct 2017