Original Operating Manual Pressure Reducer DM DK SD

Similar documents
Pressure Reducing Valve for Steam Type 2333 A

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

CAST IRON SAFETY VALVE TYPE 6301

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Pressure relief valve

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

OPERATING INSTRUCTIONS

Pressure relief valve

Engineering Data Sheet

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Materials : Stainless steel ASTM A351 CF8M

Safety Valves. Product Information. It s all at Albion

Manual Actuated Boiler Blowdown Valves

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Telefon (+45) Telefax (+45)

Type BBS-03, BBS-05, BBS-06, BBS-25

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Pressure Reducing Valve DMV 750 set range: bar

Declaration of Conformity as per Directive 97/23/EC

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Instruction Manual Contact Pressure Vacuum Gauge

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10

Model: 43T. Bermad Pressure Relief Valve

Operating and maintenance manual Filter and reducing station Series / 1.0

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Pressure Reducing Valve DMV 750

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Declaration of Conformity as per Directive 97/23/EC

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

6301 TYPE CAST IRON SAFETY VALVES

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Inverted Bucket Steam Trap IB 16A-7

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure Relief Valve DHV 718

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

SV5 Safety Valve Installation and Maintenance Instructions

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions

STAINLESS STEEL OVERFLOW VALVE TYPE 417

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Pressure Independent Control Series

Operating instructions - Translation of the original -

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Spirax Compact FREME Flash Recovery Energy Management Equipment

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

Bermad Pressure Reducing. Model: 42T

Two-stage valve type NE

Installation and Maintenance Instruction Manual

Operating and installation instructions

ITT RICHTER CHEMIE-TECHNIK

Materials : Brass body dezincification-resistant up to DN1 1/4

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Self-operated Pressure Regulators for special applications

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

PV4 and PV6 Piston Valves

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Float Operated Level Controllers

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

776 Cryogenic Safety Valve

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Transcription:

Original Operating Manual Pressure Reducer DM DK SD END-Armaturen GmbH & Co. KG Postfach (PLZ 353) 1 31 Oberbecksener Str. 78 D-357 Bad Oeynhausen Telefon (5731) 79- Telefax (5731) 79-199 http://www.end.de

Impressum by END-Armaturen GmbH & Co. KG All rights reserved. No part of this publication may be copied or published by means of printing, photocopying, microfilm or otherwise without prior written consent of END-Armaturen GmbH & Co.KG. This restriction also applies to the corresponding drawings. END-Armaturen GmbH & Co. KG has the right to change parts of the valves at any time without prior or direct notice to the client. The contents of this publication are subject to change without notice. This publication has been written with great care. However, END-Armaturen GmbH & Co. KG cannot be held responsible, either for any errors occurring in this publication or for their consequences. The products are specified by the statements in this documentation; no assurance of the properties is given. END-Armaturen GmbH & Co. KG Oberbecksener Straße 78 D-357 Bad Oeynhausen Telefon: 5731 / 79 - Telefax: 5731 / 79-199 Internet: http://www.end.de E-Mail: post@end.de Edition: 9.1 http://www.end.de 9.1

Contents Contents 1 Foreword General advice 5.1 Validity 5. Inward monitoring 5.3 Complaints 5. Warranty 5.5 Symbols and their Signification 6 3. Safety advice 7 3.1. Personal protection 7 3.1.1. Safety advice for mounting 7 3.1. Safety advice for adjustment and starting 8 3.1.3 Safety advice for maintaining / repairing 8 3. Device safety 9 Name-plate 1 5 Pressure reducer 11 5.1 General 11 5. Corresponding use 11 5.3 Mounting position 11 5. Mounting / Disassembly 1 5..1 Mounting with threaded connection 1 5.. Mounting with screw pipe connection 1 5..3 Mounting with welded connection 15 5.. Mounting with flanged connection 16 5.6 Maintenance 18 5.5.1 Cleaning of the mesh (only Art. SD) 18 6 Index 7 Declaration in conformity as defined by Pressure-Equipment-Directive 97/3/EC 9.1 http://www.end.de 3

Foreword 1 Foreword Dear customer, Dear assembler / user, these operation and installation manuals are intended to give you the knowledge which is necessary for you to be able to carry out the mounting and adjustment of an pressure reducer rapidly and correctly. Please read these instructions carefully and pay particular attention to the advice and warning notes. Only instructed and qualified mechanician should mount, adjust or maintain the pressure reducer. If you have any questions in relation to the pressure reducer, we shall be pleased to answer them. The telephone number will be found on the inside cover of these operation and installtion manual. Yours END-Armaturen GmbH & Co. KG http://www.end.de 9.1

General Advice General advice.1 Validity These mounting and installation manual is valid for the standard version of the pressure reducer.. Inward monitoring Please check - directly after delivery the pressure reducer for any transport damages and deficiencies - with reference to the accompanying delivery note the number of parts. Do not leave any parts in the package..3 Complaints Claims for replacement of goods which relate to transport damage can only be considered valid if the delivery company is notified without delay. In case of returns (because of transport damage/repairs), please make a damage protocol and send the parts back to the manufacturer, if possible in the original packaging. In case of return, please mention the following: Name and address of the consignee Stock-/ordering-/article-number Description of the defect. Warranty For our pressure reducer we give a guarantee period in accordance with the sales contract. The warranty and guarantee rules of END-Armaturen GmbH & Co. KG are applicable. 9.1 http://www.end.de 5

Symbols and their Signification.5 Symbols and their Signification Paragraphs which are identified with this symbol contain very important advices; this also includes advices for averting health risks. Observe these paragraphs without fail! Paragraphs which are identified with this symbol contain very important advices; this also includes how to avoid damage to property. Observe these paragraphs without fail! This symbol indicates paragraphs which contain comments/advice or tips. This bullet identifies the description of actions which you should carry out. 6 http://www.end.de 9.1

Safety Advice 3. Safety advice Depending on the technical circumstances and the time under and at which the pressure reducer is mounted, adjusted and commissioned, you must in each case take into account particular safety aspects! If, for example, the pressure reducer works in an operational chemical plant, the potential hazards of commissioning have another dimension from that when this is only being carried out for test purposes an a dry part of the plant in the assembly room. Since we do not know the circumstances at the time of the mounting/adjustment/commissioning, you may find advice on hazards in the following descriptions which are not relevant to you. Please observe (only) the advice which applies to your situation! 3.1. Personal protection 3.1.1. Safety advice for mounting We wish to point out expressly that the mounting, the electrical installation and the adjustment of the pressure reducer and the accessories must be carried out only by trained specialist personnel having mechanical and electrical knowledge! Switch off all the devices / machines / plant affected by mounting or repair. If appropriate, isolate the devices / machines / plant from the mains. Check (for example in chemical plants) whether the switching off of devices / machines / plant will cause potential danger. If appropriate, in the event of a fault in the pressure reducer (in a plant which is in operation) inform the shift foreman / safety engineer or the works manager without delay about the fault, in order, for example, to avoid an outflow / overflow of chemicals or the discharge of gases in good time by means of suitable measures! Before mounting or repair, remove the pressure from pneumatic / hydraulic devices / machines / plant. Empty the conduit from medium. If necessary, set up warning signs in order to prevent the inadvertent starting up of the devices / machines / plant. Observe the respective relevant professional safety and accident prevention regulations when carrying out the mounting / repair work. Check the correct functioning of the safety equipment (for example the emergency push off buttons/ safety valves, etc)! 9.1 http://www.end.de 7

Safety Advice 3.1. Safety advice for adjustment and starting As a result of the starting of a pressure reducer the flow of gases, steam, liquids, etc. may be enabled or interrupted! Satisfy yourself that, as the result of the starting or the test adjustments of the pressure reducer, no potential hazards will be produced for the personnel or the environment! If necessary, set up warning signs in order to prevent the inadvertent starting up or shutting down of the devices / machines / plant. By ending mounting check the correct function and the tightness of the valve. Check the right function of all safety devices (for example emergency off push buttons / safety valves, etc. )! Carry out the starting and the adjustments only in accordance with the instructions described in this documentation! 3.1.3 Safety advice for maintaining / repairing Do not carry out any maintenances / repairs if the pressure reducer will be under pressure. Before disassembling a pressure reducer some essential points should be clarified! Will the pressure reducer to be disassembled be replaced by another immediately? If appropriate, does the production process of the plant needed to be stopped? Is it necessary to inform specific personnel about the disassembly? If necessary, inform the shift foreman/ safety engineer or the manager about the maintenance or repair without delay in order, for example, to avoid an outflow/ overflow of chemicals or a discharge of gases in good time by means of suitable measures. Switch off pilot pressure and the power supply and relieve the pressure in the pipes. If necessary set up warning signs in order to prevent the inadvertent starting up of the devices/machines/plants in which the pressure reducer is mounted the switching on of pilot medium supply, pilot power supply and/or the power supply of actuators and accessories. In case of defect in the pressure reducer make contact to the supplier. The telephone number will be found on the back cover of these mounting and installation manual. If you ascertain a damage of the pressure reducer, isolate the device from the mains. Please observe the safety advices. Do not mount, start or adjust the pressure reducer if itself, the pipes or a mounted actuator will be damaged. 8 http://www.end.de 9.1

Safety Advice 3. Device safety The pressure reducers are quality products which are produced in accordance to the recognized industrial regulations. left the manufacturer`s work in a perfect safety condition. In order to maintain this condition, as installer / user you must carry out your task in accordance with the description in these instructions, technically correctly and with the greatest possible precision. We assume, as a trained specialist you are having mechanical and electrical knowledge! Satisfy yourself that the pressure reducers will only be used within their admissible limiting value (see the technical data). The pressure reducers must be used only for a purpose corresponding to their construction! The pressure reducers must be used within the values specified in the technical data! The operating of the pressure reducers outside the nominal temperature range could destroy the seals and the bearings. The operating of the pressure reducers outside the nominal pressure range could destroy the inner parts and the body. Never remove a cap or a other component part if the pressure reducers will be under pressure. Do not mount, start or adjust the pressure reducers if itself, the pipes or a mounted actuator will be damaged. After the maintenance or repair check the right function of the pressure reducers and the tightness of the pipe connections. Pressure reducer are not shut-off elements providing leak-proof seating. 9.1 http://www.end.de 9

Name-plate Name-plate The pressure reducers will be provided with a name-plate, which permits a definite identification of the pressure reducers and shows the most important technical data to you. The name-plate should not be displaced or changed. END-Armaturen GmbH & Co. KG D-357 Bad Oeynhausen +9 ()5731-79- www.end.de Art.Nr.: DM3313 Serial: 17/136 Inlet pressure: max 8 bar Outlet pressure:,-3 bar G/DN: 1 /" Temperature (TS): -3 C to +18 C Testing pressure (PT): 1 bar Fluidgroup: 1 Date of manufactoring:15/ Fig..1 -name-plate Art.Nr. Article number of the pressure reducer Serial Order- or production number Inlet pressure max. admissible inlet pressure of the pressure reducer [bar] Outlet pressure outlet pressure range of the pressure reducer [bar] Temperature (TS) temperature range of the pressure reducer [ C] G/DN connecting size of the valve Testing pressure (PT) testing pressure of the pressure reducer Fluidgroup allowed fluid group of the pressure reducer Date of manufacturing Week and year of the manufacturing 1 http://www.end.de 9.1

1 1 3 3 EN837-1 5 6 8 7 6 5 Mounting position 5 Pressure reducer 5.1 General Before mounting /disassembly the pressure reducer we assume that you have read the advices and warnings from chapter 3. safety advice If you have not read chapter 3. until now, read these important advices now and turn back to this page. 5. Corresponding use Pressure reducers will be used to reduce the medium pressure (inlet pressure) upstream of the pressure reducer to a reduced pressure (outlet pressure) downstream of pressure reducer. It should only be used clean liquids and gases without doubts concerning the material resistance of the pressure reducer. Pollution or using outside the nominal pressure range and/or the nominal temperature range should causes damages on the pressure reducer especially on the diaphragm. Pressure reducer are regulating devices, not shut-off elements providing leak-proof seating. A leakage rate of,5% of the Kvs- value is permitted. Therefore we recommend the installation of a shut-off valve. 5.3 Mounting position The preferred location of pressure reducers in pipework systems is where the operating conditions are stable, that is not immediately upstream or downstream from bends, branches, pressure devices, stop valve fittings or similar restricting elements, and not adjacent to consumer points. Pressure reducer should be fitted to horizontal sections of the pipe. Mounting position at liquid and gaseous media PN DN5 1.8 psi bar DN5 PN 1.8 Fig. 5.1 - Pressure reducer, Mounting position at liquid and gaseous media 9.1 http://www.end.de 11

1 1 3 3 EN837-1 5 6 8 7 6 5 Mounting position At liquid and gaseous media the piston design pressure reducer and the diaphragm design pressure reducer with size: 1/3/5 can be fitted with vertical up and vertical down standing spring bonnet. Diaphragm design pressure reduce for extremely low outlet pressures must be fitted with vertical down standing spring bonnet. At steam application all pressure reducers must be fitted with vertical down standing spring bonnet. mounting position medium steam PN DN5 1.8 psi bar Fig. 5. - pressure reducer, mounting position medium steam 5. Mounting / Disassembly The mechanical installation are the same by all variants. It differs by the type of connection only. Consider the flow direction of the medium, specified on the valve body. Pressure reducers should be install with released spring. We recommend the installation of a shut-off valves in front of and behind the pressure reducer to enable to clean the pressure reducer without empty of the conduit. Remove the hole packing material (e.g. caps and plugs). Take care that there will be no packing material or other pollution in the pressure reducer. Before mounting the pressure reducer clean up the pipes. If fouling during operation is unavoidable, a strainer must be fitted in front of the pressure reducer. Avoid strains on the body by non align pipes. Screw a manometer into the manometer port. Not used ports must be closed by fit plugs. In same cases the installation of a safety valve behind the pressure reducer will be necessary to prevent the maximum permissible pressure from being exceeded in the downstream section of the pipe. 1 http://www.end.de 9.1

AUF OPEN ZU CLOSE END-Armaturen GmbH & Co. KG 357 Bad Oeynhausen Germany http://www.end.de post@end.de AUF OPEN ZU CLOSE END-Armaturen GmbH & Co. KG 357 Bad Oeynhausen Germany http://www.end.de post@end.de 1 1 3 5 3 EN837-1 6 7 8 psi bar 6 5 1 1 3 3 EN837-1 psi bar 5 6 8 7 6 5 3 5 3 EN837-1 6 1 7 5 1 8 psi 6 bar 1 1 3 3 EN837-1 psi bar 5 6 8 7 6 5 AUF OPEN ZU CLOSE END-Armaturen GmbH & Co. KG 357 Bad Oeynhausen Germany http://www.end.de post@end.de AUF OPEN ZU CLOSE END-Armaturen GmbH & Co. KG 357 Bad Oeynhausen Germany http://www.end.de post@end.de Mounting / Disassembly 1 5 3 DN5 PN 1.8 1 pressure reducer shut-off valve 3 strainer manometer 5 safety valve Fig. 5.3 - pressure reducer, mounting diagram S E S A S E 5 x DN S A 1 x DN Where a fault in the pressure reducer could result in an unacceptable breakdown of downstream consumer units, a by-pass with a shut-off device must be provided. In the event of a fault, emergency operation can be maintained via by-pass. The by-pass must be kept closed during normal operation. AUF OPEN ZU CLOSE END-Armaturen GmbH & Co. KG 357 Bad Oeynhausen Germany http://www.end.de post@end.de 1 5 3 5 DN5 PN 1.8 1 pressure reducer shut-off valve 3 strainer manometer 5 safety valve 5xDN 1xDN S E 5 x DN S A 1 x DN Fig. 5. - pressure reducer, mounting diagram with by-pass Special Advice,- installation in boiler systems Pressure reducer have to be installed in the upstream (cold water) of the system to avoid calcification. The distance to the check valve has to be far enough that the pressure reducer can not be reached by hot water even if the check valve is defective. Please refer to DIN 1988 and AD leaflet A3 DIN 753. 9.1 http://www.end.de 13

Mounting / Disassembly 5..1 Mounting with threaded connection Before lay on sealing compounds, check the hardly screwing by the pipes into the pressure reducer`s body. Lay on the correct sealing compounds on the pipes end. By using PTFE- ribbon or hemp seals consider the screw direction. Don t use sealing compounds which are not prescribed for your employment. Screw the pipes into the threaded ends of the pressure reducer. Don t use the bonnet of the spring as a lever. Strike up the pipes with pressure after that time the manufacturer of the sealing compounds pretends for harden it. Check the tightness of all connections. 5.. Mounting with screw pipe connection Before lay on sealing compounds, check the hardly screwing by the pipes into the pressure reducer`s body. Lay on the correct sealing compounds on the pipes end. By using PTFE- ribbon or hemp seals observe the screw direction. Don t use sealing compounds which are not prescribed for your employment. Put the screw caps onto the pipes and screw the screw pipe connections into the pipes. sealing compound harden o.k. S EN837-1 3 5 1 1.571 bar KL1,6 6 flow direction Fig. 5.5 - pressure reducer, mounting with screw pipe connection (Fig. Art. SD5). Option: manometer Art.MO73xx 1 http://www.end.de 9.1

Mounting / Disassembly Put the pressure reducer with the seals between the screw pipe connections and tighten the screw caps. Adjust the pressure reducer to the pipes. Tighten the screw caps. Strike up the pipes with pressure after that time the manufacturer of the sealing compounds pretends for harden it. Check the tightness of all connections. 5..3 Mounting with welded connection The safety demands by welding are depending on the place and the position of the point of weld. Welding the parts at a serviceable device/machine/plant the potential of danger is as higher as welding the parts in a welding room. If appropriate, inform the shift foreman / safety engineer or the works manager and the fire brigade of your factory By welding observe your own national guide lines about safety and prevention of accidents. By welding the body of the pressure reducer with the pipes observe appropriate demands and guide lines. o.k. flow direction Abb. 5.6 - pressure reducer, mounting, welded connection, use of heat absorbing paste (Fig. Art. DM3336). 9.1 http://www.end.de 15

Mounting / Disassembly To protect the seals of the of a pressure actuated valve you have to apply a amount of heat absorbing paste (e.g. TECHNOLIT heat absorbing paste, BLOC-IT heat absorbing paste, METAFLUX THER- MEX) to the area to be protected. By using the heat absorbing paste you have to observe the instructions of the manufacturer. By making multiple welding seam, the valve will have to be cool down after every working operation. After welding check the function of the pressure reducer. Check the tightness of all the connections. 5.. Mounting with flanged connection We assume, that you have mounted the flanges at the end of pipes and they are cooled down. (e.g. welded flanges). Push the body of the pressure reducer between the flanges by using the appropriate seals. Aligns the flange boring and put the fit screws through the holes. S EN837-1 3 5 1 1.571 bar KL1,6 6 Fig. 5.7 - pressure reducer, mouting with flanged connection (Fig.: Art. DM333). Option: manometer Art.MO73xx 16 http://www.end.de 9.1

Operation Screw the fit nuts onto the screws and tighten it up crosswise. By doing this consider the maximum torque moment of the screws. Check the tightness of all connections. 5.5 Operation Before putting the the pressure reducer into operation the regulation spring should be released by turning the toggle spindle anticlockwise. The upstream shut-off valve must be opened slowly until the inlet pressure reaches the limit. Next adjust the outlet pressure by turning the toggle spindle clockwise There must be some medium consumption on the outlet side to set the required outlet pressure. Adjusting the desired outlet pressure at zero consumption observe that the outlet pressure will decrease below the adjusted range in case of medium consumption. The pressure decrease is depending on the medium consumption. Adjusting the desired outlet pressure at medium consumption observe the outlet pressure will increase above the adjusted range in case of zero consumption. Once the adjustment is complete, the toggle spindle should be secured with the lock nut. During the adjustment a sharply fluctuating flow or shock pressure loading are to be avoided. In case of using the pressure reducer for steam applications the tightening of the screws and the ground cap once the pressure reduce has throughly heated up will be necessary. decrease outlet pressure increase outlet pressure Fig. 5.8 - pressure reducer, adjustment of the outlet pressure (Fig. shows Art. DM3333). 9.1 http://www.end.de 17

Maintenance 5.6 Maintenance Before you maintain or shut down the pressure reducer you have to read Safety advice If you have not read the safety advices until now, read these important advices now and turn back to this page. On normal accounts the pressure reducer is maintenance free. In periodical turns you have to: Check the function of the pressure reducer Check or clean the mesh (only Art. SD) Check the right outlet pressure Check the tightness off all the connection In case of a defect of the pressure reducer make a contact to the supplier. The telephone number will be found on the back or these operation and installation manual. If you determinate that there is a damage to the pressure reducer switch off the device/ machine/ plant! However before doing this, it is essential to refer to the Safety advice. 5.5.1 Cleaning of the mesh (only Art. SD) Cut off the medium flow on both sides of the pressure reducer and release the pressure in the pressure reducer. Keep ready some fit tanks to catch up leaking liquids. Before disassembling the pressure reducer you have to release the spring to prevent the fly around of the pieces. Heavy injuries of persons or damages of the pieces would be the result. Turn the adjustment screw anti clockwise until the spring is totally released. Loosen the bonnet with a fit spanner (Art. SD). Take off the bonnet of pressure reducer and take it by side carefully. Take off all the inner parts of the pressure reducer and take them by side carefully. Now the mesh could be taken out of the body of the pressure reducer. By mounting please consider, that the cam or peg will be placed exactly above the counter part at the body, that the inner parts will not be braced by the placement into the body 18 http://www.end.de 9.1

Maintenance the correct placement of the seals, that there will be no pollution on the seals. After mounting check the function of the pressure reducer. Check the tightness of all connections. spring loaded 3 S EN837-1 5 1 1.571 bar KL1,6 6 Fig.. 5.9 -pressure reducer, cleaning of the mesh( Art. SD5). Option: manometer Art.MO73xx 9.1 http://www.end.de 19

Index 6 Index Index A AD leaflet A3 DIN 753... 13 C Cleaning of the mesh... 18 Complaints... 5 Corresponding use... 11 D Date of manufacturing... 1 Device safety... 9 DIN 1988... 13 Disassembly... 1 F Fluidgroup... 1 Foreword... G General advice... 5 H Heat absorbing paste... 15, 16 I Inlet pressure... 17 Inlet pressure... 1 Input pressure... 17 Installation in boiler systems... 13 Inward monitoring... 5 K Kvs- value... 11 M Maintenance... 18 Mounting... 1 Mounting diagram... 13 Mounting diagram with by-pass... 13 Mounting position... 11 Mounting position at liquid and gaseous media... 11 Mounting position medium steam... 1 Mounting with flanged connection... 16 Mounting with screw pipe connection... 1 Mounting with threaded connection... 1 Mounting with welded connection... 15 Multiple welding seam... 16 N Name-plate... 1 O Operation... 17 Outlet pressure...1,17 Outlet pressure - decrease... 17 Outlet pressure - increase... 17 P Personal protection... 7 R Regulation spring... 17 S Safety advice... 7 Safety advice for adjustment... 8 Safety advice for maintaining... 8 Safety advice for mounting... 7 Safety advice for repairing... 8 Safety advice for starting... 8 Serial...1 Shock pressure loading... 17 Steam application... 1 Steam applications... 17 Strainer... 1 Symbols and their Signification... 6 T Temperature... 1 Testing pressure... 1 V Validity... 5 W Warranty... 5 http://www.end.de 9.1

(1) Declaration in conformity () as defined by Pressure-Equipment-Directive 97/3/EC (3) This declaration apply to the article groups with the nominal sizes: Articles Nominal size Pressure Reducer DK ½... DK DN15... DN5 DM ¼... 1½ DM DN1... DN5 SD "... " and all variations of these articles () of the company END-Armaturen GmbH & Co. KG D-357 Bad Oeynhausen Germany (5) Herewith we declare that the above-mentioned articles in the conditions of our delivery are in conformity with the regulations of Article 3 Part 3 of the directive 97/3/EG. These products bear no CE mark, but are in line to the good engineering practice designed and manufactured. (6) Applied harmonized standards, in particular: DIN EN 1516:5 Industriearmaturen - Gehäusefestigkeit (7) Bad Oeynhausen, 1. Oktober 11 Michael End Quality Manager END-Armaturen GmbH & Co. KG Oberbecksener Str. 78 357 Bad Oeynhausen Germany Telefon: +9 ()5731-79- Telefax: +9 ()5731-79-199 http://www.end.de post@end.de Declaration without signature or company stamp shall not be valid. The declaration may be circulated only without alternation. Extracts or alternations are subject to approval by END-Armaturen GmbH & Co. KG. END-Armaturen GmbH & Co. KG Postfach (PLZ 353) 1 31 Oberbecksener Str. 78 D-357 Bad Oeynhausen (Germany) Telefon +9-5731 - 79- Telefax +9-5731 - 79-199 http://www.end.de

Notice http://www.end.de 9.1

Notice 9.1 http://www.end.de 3

watergates knife-gate-valves - Stoffschieber END-Armaturen GmbH & Co. KG Oberbecksener Str.78 D-357 Bad Oeynhausen Postfach (PLZ 353) 1 31 Telefon +9 () 5731 / 79- Telefax +9 () 5731 / 79-199 Internet http://www.end.de E-Mail post@end.de Watergates GmbH & Co. KG Oberbecksener Str.7 D-357 Bad Oeynhausen Postfach (PLZ 353) 1 31 Telefon +9 () 5731 / 79- Telefax +9 () 5731 / 79-199 Internet http://www.watergates.de E-Mail post@watergates.de http://www.end.de 9.1