PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Similar documents
PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED CHECK VALVE - Series VC4V

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

PRESSURE SEQUENCE VALVE TYPE UZK

Electrically Operated Pressure-Relief Cartridge, Size 10

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

PRESSURE COMPENSATORS TECNORD

Inverse Proportional Pressure-Relief Cartridge, Size 10

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Proportional Pressure-Relief Cartridge Valve, Size 2...4

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure reducing valve, pilot operated, Model 3DR

PVQ 13 A2 R SE 1 S 20 C-11 D

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Pressure reducing valve, direct operated

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

IFP C175-* REMOTE CONTROL RELIEF VALVE

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure reducing valve, direct operated

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Check valve hydraulically pilot operated

Proportional Throttle Cartridges, Size 16

Pressure-Relief Cartridge Valve, Size 4

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Leak free Pipe Rupture Valve for Excavators

Pressure reducing valve, pilot operated

2-way flow control valve Model 2FRM 6

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

PLD 03 T A CASAPPA S.p.A.

Directional Controls

Safety and Shut-off Block SAF/DSV

3-Way Pressure-Reducing Cartridge, Size 2 4

Directional Controls

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

shutoff valves 900 Series psig Manual Shutoff Valves

VSD03M DIRECTIONAL CONTROL VALVES

Axial piston pumps type PVC

Axial piston pumps type PVC

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Axial Piston Variable Pump A10V(S)O (US-Version)

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Leak-Free Load-Control Valve SAE ½ psi flange

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

OMS Technical Information. Versions OMS. Versions

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Pressure Reducing Valves Catalog Quick Reference

P.C. Flow Regulator Valve Series FR101. General Description

180 Series Rotary Shear Directional Control Valve

4/2 way Pneumatic Solenoid Valve

Intrinsically safe solenoid valves on/off controls - ATEX certification

Safety and Shut-off Block SAF/DSV

Double Pilot Operated Cartridge Check Valve, Size 8

Axial piston-variable motor A10VM Plug-in version A10VE

Solenoid valves VZWF, force pilot operated

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

DNS. Monoblock directional control valves DNS - Directional control valve

Cover headline. Cover subheadline. Check Valves

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Digital directional & flow control valves D-DF(R)G

Air preparation units

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Pressure reducing/relief valve, pilot operated type UZCP10

3-Way Safety Block DSV

SDM to 8 sections monoblock valve D1WWDA02A

Pressure relief valve, direct operated Type DBD

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

SOLENOID VALVES AND PNEUMATIC VALVES

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Hand & mechanical directional valves

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Safety and Shut-off Block SAF/DSV

SystemStak Valves. ISO4401 Size 02

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

2/2-Way Solenoid Control Valve

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Pressure relief valve, direct operated

D62 - D63 Directional Control Valve l/min

Cooler-Bypass Thermostat Valve, Size 16

Leak-Free Load-Control Valve, Size 20

Transcription:

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is maintained as set by control knob on the pilot or by an external pilot source. In some application,vr4r is used to maintain a lower pressure in the secondary circuit to limit the force available from certain actuators. X VR4R consists of a high flow poppet type seat valve section controlled by the low flow, adjustable pilot section mounted on top. Pressure setting is achieved by means of a knurled knob. For tamper proof setting, acorn nut with lead seal is available as an option. Optional vent valve VVVO1 sandwiched between pilot section and main body can be used for venting the VR4R valves. Extremely accurate settings can be obtained due to the precise construction of control components. The design of poppet allows for the minimum of friction and hysteresis giving a sensitive response to conditional changes. 1 OPTIONL Normally, port is connected to the secondary part of the hydraulic circuit and port to the primary part. When the secondary port is unpressurised, the main poppet opens downwards against a spring by the pressure at primary Port. Flow passes from primary port to secondary port. Pressure at port passes to the pilot section and to the top of main poppet through an orifice. No flow takes place in this section until the pressure demand exceeds the setting of the X pilot head,as determined/set by the control knob. The pilot cone lifts from its seat against the setting spring and allows a maintained pilot flow to pass to external drain. The effect of this is to limit the pressure available on top of the main poppet. In this condition the main poppet moves up and floats allowing enough flow to the secondary circuit ( port ) to maintain the set pressure. If the secondary circuit exceeds the pilot head setting, the main poppet moves up further and closes preventing flow to a secondary circuit. Possibilities of any pressure intensification in the secondary part is eliminated by the small check valve when it opens and allows flow to pilot drain.

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R SPECIFICTIONS General Type : Pilot operated Pressure reducer Valve Design : Poppet type Mounting : Threaded/Subplate/Cartridge Mounting position : Optional Port sizes (nominal) : 3/8, 3/4, 1 1/4 Direction of flow : mbient temperature : --2 C...+6 C (--4 F...+14 F) Special working conditions : Consult VELJN Hydraulics Pressure control range : Minimum - depends on flow Maximum - 5 psi (35 bar) Maximum operating pressure : Port ( primary ) 5 psi (35 bar) Port ( secondary ) 5 psi (35 bar) Port X (pilot) Port, 1 (Pilot drain ) 5 psi (35 bar) Without pressure to tank : VR4R 3 ( 3/ ) VR4R 6 ( 3 8 / 4 ) VR4R 1 ( 1 1/ 4 ) Nominal flow gpm ( lpm) : 15.8 (6) 52.9 (2) 119. (45) Maximum flow gpm ( lpm) : 23.8 (9) 79.4 (3) 158.7 (6) Fluid : Mineral oil as per DIN 51524/25 or other fluids on request Fluid Temperature Range : -18 C...+ 8 C ( F...+176 F) Viscosity Range : 1 to 65 cst (6 to 39 SSU) Optimum operating viscosity : 3 cst (18 SSU) Seal compatibility : Code 1 (una N) or Code 5 (Viton) (contact Veljan with specific oil details) Cleanliness recommended : etter than NS 1638 Class 8 or ISO 17/14 djustment Manual : Handwheel Rotation : 3.75 rev. Operating torque :.72 Nm Electricals ( Vent Valve VVV1) : Solenoid Nominal voltage : Refer to Ordering Code Permissible voltage fluctuation : +5%...--1% Max. coil temperature : +155 C (311 F) Type of current : lternating Current (C)/Direct Current (DC) Input power : 31 W Holding : 78 V Inrush : 264 V Relative operating period : 1% Type of protection : I P 65

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R ORDERING CODE VR4R 6-5 6 5-1 - 9 - W7-1 *** Series Size 3 3 - / 8 6-3/ 4 1-11/ 4 Max. Pressure of Valve ody - for cartridges only 5-5psi (35 bar) ody Mounting Cartridge - Cartridge X 1 + 1port = 1/ 4 NPTF E - Cartridge X 1 + 1 port = SE - 4 ( 7/16-2 UNF) G- Cartridge X 1 + 1 port = G 1/ 4 Threaded body 1 1 - Threaded body - VR4R3 = 2/ NPTF ;,1ports (2- Ports,1-Port) = 1 - Threaded body VR4R6 = 3/ / 4 4 NPTF NPTF (1-Port,1-Port) 1 6 - Threaded body VR4R3 = 2/.S.P.P ; (2-Ports,1-Port),1ports D - Threaded body VR4R6 = 3/.S.P.P ; =G 1/ 4 4 (1-Port,1-Port) 4 - Threaded body VR4R3 - SE - 8 X 1,1ports (2- Ports,1-Port) =SE-4 - Threaded body VR4R6 - SE - 12, (7/16 - (1-Port,1-Port) 2 UNF) Subplate mounting 3 - Subplate mounting X 1+ 1 port = 1/ 4 NPTF 7 - Subplate mounting X+ ports=se-4( 7 / 1 1 16-2UNF) 9 - Subplate mounting X 1+ 1 Ports = G1/ 4 Pressure setting range 1-1 - 15 psi (7-15 bar) 3-1 - 3 psi (7-21 bar) 5-1 - 5 psi (7-35 bar) Solenoid Voltage (Omit for non vent version) Drain line Modification Seal Class 1 5 - una N ( Standard) - Viton Design letter W1-115V/6 Hz C GOR - 12V DC W2-23V/6 Hz C GOQ - 24V DC W6-115V/5 Hz C GOH - 48V DC W7-23V/5 Hz C Electrical Vent (3way VENT VLVE VVV1) Omit for non vent version 9 - With manual override (Solenoid de-energized : open to tank. Solenoid energized : vent line blocked) 1 - Without manual override (Solenoid de-energized : open to tank. Solenoid energized : vent line blocked) 11 - With manual override (Solenoid de-energized : vent line blocked Solenoid energized : open to tank) 12 - Without manual override (Solenoid de-energized : vent line blocked Solenoid energized : open to tank) 1 2 - drain to manifold (only for cartridge) - External from subplate or manifold () - External from pilot head ( 1) Type of Control t subplate mounting only with body code 3,7,9 1-Hand knob (32mm dia) 2-Hand knob (5mm dia) (not for version with vent valve VVV1) 3-corn nut with lead seal

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R PERFORMNCE CURVES ps min - qv characteristics VR4R3 Minimum Differential Pressure between Inlet & Outlet Pressure at Various Flow Rates Variation in Outlet Pressure for variation in Flow Rate The effect of increase of Inlet Pressure on Outlet Pressure setting Differential pressure in bar (psi) 25 (362.5) 2 (29.) 15 (217.5) 1 (145) 5 (72.5) 2 4 6 8 1 (5.3) (1.6) (15.9) (21.2) (26.5) Outlet pressure in bar (psi) 35 (575) 3 (435) 25 (3625) 2 (29) 15 (2175) 1 (145) 5 (725) Inlet 35 bar (5 psi) Inlet 28bar (4 psi) Inlet 21 bar (3 psi) Inlet 15 bar (15 psi) 2 4 6 8 1 (5.3) (1.6) (15.9) (21.2) (26.5) Outlet pressure in bar (psi) 25 (3625) 2 (29) 15 (2175) 1 (145) 5 (725) qv=22 lpm (5.8 gpm) 5 1 15 2 25 3 35 (725) (2175) (3625) (575) (145) (29) (435) Flow qv lpm(gpm) Flow qv lpm(gpm) Inlet Pressure in bar (psi) VR4R6 & VR4R1 Differential pressure in bar (psi) 25 (362.5) 2 (29) 15 (217.5) 1 (145) 5 (72.5) Minimum Differential Pressure between Inlet & Outlet Pressure at Various flow Rates 1 2 3 (26.5) (53.) (79.5) Outlet pressure in bar (psi) 35 (575) 3 (435) 25 (3625) 2 (29) 15 (2175) 1 (145) 5 (725) Variation in Outlet Pressure for variation in Flow Rate Inlet 35 bar (5 psi) Inlet 28bar (4 psi) Inlet 21bar (3 psi) Inlet 14 bar (2 psi) Inlet 7 bar (1 psi) 1 2 3 (26.5) (53.) (77.5) Outlet pressure in bar (psi) 3 (435) 25 (3625) 2 (29) 15 (2175) 1 (145) 5 (725) The effect of increase of Inlet Pressure on Outlet Pressure setting Q=18 lpm (47.36 gpm) 5 1 15 2 25 3 35 (725) (145) (2175) (29) (3625) (435) (575) Flow qv lpm(gpm) Flow qv lpm(gpm) Inlet Pressure in bar (psi) Note : ll Performance Data given is typical and can be influenced by application. Oil Temperature = 45 C (113 F) ; Oil Viscosity = 4cSt (24SSU).

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R CRTRIDGES WITH PILOT VLVES VR4R6/VR4R1 ( #, #E & #G ) (1/4 NPTF or G1/4" or SE-4) Weight : 2.64 lbs (1.2 kg) 45 ø ø 1 15 5 X 1.6 1.6 ø max 15.3 ø6 max 4 3 2 2.5 1 r Max C7 r Max øc9 max C8 ø ø ø 3/8-24 UNF x.79 dp. (M1 x 2 dp.) C7 C8 C9 1 2 3 4 5 6 ø1.73/1.77 ø1.5 ø1.52 1.99/2. 1.28.8.8 r.16 r 1.2 ø1.1 ø.25.4 1.75 1.8/1.1.4.6 ø1.26 ø44./45. ø38.1 ø38.139 5.73/5.8 32.5 2. 2. r.4 r 26. ø28. ø6.3 1. 44.5 27.5/28. 11. 1.6 ø32. 2.367/2.383 6.12/6.52 1.24/1.26 31.55/31.95 ø.126 ø3.2 1.38 35. 1.12 ø.126 ø.236 28.5 ø3.2 ø6. Ports X, 1 Function Primary (Inlet) Secondary (Outlet) Internal pilot pressure Remote control or vent connection External drain or 4 Mounting screws* 3/8-24 UNF x 1 3 /4 lg. M1 x 45mm, DIN 912-12.9 Order - No. V359-1522 or V7-7162 * Mounting screws must be ordered separately

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R VR4R1 (1 1/4 ) SUPLTE MOUNTING OD ( #3, #7 & #9 ) 4 3 2 1 1 max Panel opening Weight : 13.18 lbs (6. kg) 1 ø 11 6 5 7 ø12 9 8 ø1 1 lock mounting face Flatness.1 mm/1 mm length Surface finish CL 1.27 µm 2 3 1 ø7 D7 D8 ø2 ø1 ø3 6 5 3/8"-16 UNC x.71 dp.. (M1 x 18 dp.) D9 Location hole 4 1 2 3 4 5 6 7 8 9 1 11 12 5.55 141. 2.34 59.5 1.41 35.8.14 3.6 4.645 118. 3.846 97.7 3.15 8. 5.645 143.5.25 6.4 ø.41 ø1.5 1.14 29. ø.65 ø16.5 1 2 3 4 5 6 7 1.181 3. 4.72 12. 3.8 96.52 4.51 3.315 1.657 114.5 84.2 42.1 ø1.26 ø32. Ports,( 1) Function Primary (inlet) Secondary (Outlet) Remote control or vent connection External drain 6.3 16. 1.456 37. 3.315 ø.35 5.433 4.88 84.2 ø9. 138. 124. D7 D8 D9 1 2 3 3.315 2.657 2.342 84.2 67.5 59.5 1.657.657 42.1 16.7 3.81 96.8 1.96 48.4.15 3.8 2.468 62.7 4.724 12. ø.28 ø1.26 ø7.1 ø32. ø.28 x ø7.1 x.315 dp. 8. dp. Note : For details of Subplate & mtg.screws please refer page 74

PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Subplate for VR4R1 Weight : 19.1 lbs ( 8.5 kg) 1 2 3 4 5 6 3/8-16 UNC x.71 dp. (M1 x 18 dp.) 12 1 ø17 7 9 ø16 15 14 ø19 ø18 ø4 8 ø1 2 r 11 13 3 Location hole 2 Note: Not used,must be plugged before installation (1/4 NPTF or G1/4 ) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 3.315 2.657 2.342 1.657.968.657 3.811.811 3.653 1.95 2.468.15 6.535 6.5 5.43 1.26 ø.28 ø.28 x.315 dp. ø.28.4 r 84.2 67.5 59.5 42.1 24.6 16.7 96.8 2.6 92.8 48.4 62.7 3.8 166. 165. 138. 32. ø7.1 ø7.1 x 8. dp. ø7.1 1. r 1 2 3 4 ø.351 ø9. 1.97 1.38 5. 35. ø.59 ø15. 3.315 84.2 2.342 59.5.97 24.6 4.66 118.4 2.716 69..764 19.4 Order No. + Port sizes Dimension 4 Mounting screws* Order No. min.tensile strength VSS - P -16 - G 114 VSS - -12 - G 115 VSS - - 16 - G 115 1 NPTF 3/4.S.P.P. 1.S.P.P 1/4 NPTF 1/4.S.P.P. 3/8-16UNC 1 3 /4 lg M1 x 45mm DIN 912-12.9 V359-1622 V7-7162 2 at p< 21 bar = 1 dan/mm - (Torque 68 Nm) 2 at p>21 bar = 12 dan/mm (Torque 82 Nm) * Mounting screws are included in subplate order. For valves ordered without subplate, mounting screws must be ordered seperately.

PILOT PILOT OPERTED PRESSURE REDUCER VLVE VLVE - Series - Series VR4R VR4R OPTIONL CONTROL Type of control - Code 3 cron nut with lead seal Type of control - Code 2 Hand knob 5mm dia (not for version with vent valve VVV1) 1 1 1 1 Weight (VVV1) : 3.73 lbs (1.7 kg) Screws for additional vent valve installation. 4 x M1 X 9 long Pilot valve Vent valve VVV1 Manual override Main valve Plug-in connector DIN 4365 (supplied as standard) PG 9/11 ø 1 Max. 2 2 3 4 in mm in mm 1 2 5.51 1.49 14. 38. 1 2 3 4 5.55 1.67 1.49 ø1.96 141. 42.5 38. ø5. Version with Vent Valve VVV1 1 Code External Drain X 2 2 X Z 11 or 12 X X X 1 1 9 or 1 X X D7 D8 D9 C 149 DC 16 Solenoid coil can be positioned -at 9 intervals (C) -In any position (DC) 1.85 47. D7 D8 D9 1 in ø.41 2.3 1.25.18.12.81 2.31 2.37 3.49.51 2.75 mm ø1.5 51.8 31.8 4.8 3.2 2.6 58.7 6.3 88.7 13. 7.