The routine maintenance and inspection of local exhaust ventilation (LEV)

Similar documents
GSA POLICY ON LOCAL EXHAUST AND OTHER VENTILATION (FUME CUPBOARDS)

Proficiency Module Syllabus. P601 - Thorough Examination and Testing of Local Exhaust Ventilation Systems

TExT Thorough Examination & Test of LEV Local Exhaust Ventilation Systems

Work Equipment: LOCAL EXHAUST VENTILATION

LEV Issues. Local Exhaust Ventilation. A Salesman Approaches! Why is LEV important? What is it supposed to do? What comprises an LEV system?

LEV GUIDANCE FOR SAFE USAGE, TESTING AND MAINTENANCE OF LOCAL EXHAUST VENTILATION SYSTEMS WITHIN ANGLIA RUSKIN UNIVERSITY RISK MANAGEMENT

LEV Inspection & Test Report

Vertex VP Operation and Maintenance

Thorough Examination and Test of Local Exhaust Ventilation Systems to Regulation 9 of the COSHH Regulations 2002 (as amended)

Maintenance, examination and testing of local. exhaust ventilation

Laboratory Ventilation. Environmental, Health, and Safety

ESTATES OFFICE OPERATIONS WORKS INSTRUCTIONS WI 6. Fume Cupboards, Ventilated Cabinets, Local Exhaust Ventilation

Reviewed: November 2013 POLICY AND GUIDELINES THE DESIGN INSTALLATION AND ONGOING MAINTENANCE & TESTING OF LOCAL EXTRACT VENTILATION

Personal Protective Equipment

Index to the Control Guidance Sheets

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable.

Vision Painting Inc Safety Management System

Local Exhaust Ventilation (LEV)

Controlling airborne contaminants at work

Safety Services. Introduction

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

New Licensed Asbestos Operative Training

Helping you to correctly select and use respirators. With support from

Refresher Licensed Asbestos Supervisor Training

New Licensed Asbestos Manager Training

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

USER MANUAL. JET TST and JET TST S.

POLICY FOR COSHH (CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH) POLICY

Pressure Systems Safety Regulation

Control of Allergies to Laboratory Animals

Level 4 Certificate in Asbestos Removal for Contract Managers

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

LABORATORY SAFETY SERIES: Laboratory Hoods

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd

Safety Services Guidance. Guidance on: The Provision and Use of Work Equipment Regulations 1998 (PUWER)

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

in Australian Workplaces

"LABORATORY SAFETY SERIES"

Kansas State University Fume Hood Operation

RISK ASSESSMENT A UNIVERSITY GUIDE TO PRACTICAL RISK ASSESSMENT UNDER THE MANAGEMENT OF HEALTH AND SAFETY AT WORK REGULATIONS 1992

HAS2400 Hepa Air Scrubber

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

Choosing and Installing Microbiological Safety Cabinets

SEMMPF201 Complying with Statutory Regulations and Organisational Safety Requirements

Highlights of Respirable Crystalline Silica. Jim Shelton, CAS Houston North Area Office

Selection, use and maintenance of Microbiological Safety Cabinets

Seed Treatment Safety and Regulations Crop Protection Perspective. Chip Witcher / Staff Industrial Hygienist / Syngenta Crop Protection

CTG Certification Protocol -- Version 3.0 SUMMARY

HEALTH & SAFETY GUIDANCE

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

A. Evaluation of the written program

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

Hampstead Hill School Health and Safety Policy: Confined Spaces

PLANT HAZARD REPORT. Plant Description: Element Aspect Plant Hazards and Controls Advice. Circular Saw

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Respiratory Protection

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

UHSE. Bath University HR Department UHSE. Safe Use of Fume Cupboards. Document Information

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

2.25 Work Equipment Policy and Procedure Table of Contents

Unit PS1. Element 3: Common Hazards, Risks and Controls in the Chemical Industry. (Material correct Summer 2013)

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

Respiratory Protective Equipment

The inspection and maintenance of work equipment

Evaluating Industrial Ventilation Systems: Five Overlooked Aspects of Evaluating Industrial Ventilation Systems. Brought to you by:

Design & Technology Department Health & Safety Policy. Outwood Academy Ripon

Managing worker exposure to dust in mines and quarries

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015

Toolkit for safe Use of Microbiological Safety Cabinets(MSC s)

SOP. Working in Confined Spaces

SKAC25 Operate plant to maintain the quality of pool water

SEMBIT SQA Unit Code F9JC 04 Complying with statutory regulations and organisational safety requirements

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Wilkins Safety Group

INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Appendix A: Induction check list

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

Good things come in threes

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

LEGIONELLA MANAGEMENT PROCEDURE

TOXIC GAS DETECTORS IN THE WORKPLACE UK REGULATIONS AND STANDARDS

Abrasive Blasting Removal Systems

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

2017 Edition GUIDANCE NOTE GN 8 INVERTER DRIVES FOR FANS AND PUMPS GN 8 - INVERTER DRIVES FOR FANS AND PUMPS

Exposure Control Plan for Drilling/Grinding Concrete

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.

Hot tubs for Business why you need the PWTAG publication. Janice Calvert MSc,CChem,FRSC,FRSPH,FPWTAG Chair PWTAG

Revision 1. Review Date 1/9/2013

Transcription:

The routine maintenance and inspection of local exhaust ventilation (LEV) This document details the standards for inspection and maintenance that should be achieved for all local exhaust ventilation owned and operated by the University. The requirements are based on best practice and when met will ensure the University meets its legal obligations to provide and maintain safe equipment and a safe working environment. It is outside the scope of this document to provide detailed guidance for specific testing methods or maintenance activities. The inspection and maintenance required to ensure systems continue to perform to an acceptable standard will be detailed in the user manual for each system. Staff undertaking the routine maintenance and inspection of LEV systems may need additional information, instruction and training. Equipment to measure air flow and measure the concentration of contaminants in air will be necessary. Summary of requirements Local exhaust ventilation is maintained in an efficient state, in efficient working order and in good repair at all times. Annually, as a minimum, the Head of Technical Services will check to ensure that Technicians maintain a comprehensive manual for LEV systems in their area. A suitable log book and user manual, containing the commissioning details, is available for each LEV system at its location. Competent people are identified to carry out the routine maintenance and inspection of each LEV system and have been provided with the training and equipment necessary to carry out these duties. The results of all maintenance and inspections are recorded and the records kept for the period specified in the H&S document retention schedule (see intranet pages for details). All staff using and operating LEV have sufficient information, instruction and training to do so. Related Documents UAL Health and Safety Standard The inspection and maintenance of work equipment INDG 408 Clearing the air a simple guide to buying and using local exhaust ventilation HSE HSG 258 Controlling airborne contaminants at work A guide to local exhaust ventilation HSE 2011 Related legislation The Control of Substances Hazardous to Health Regulations 2002 The Provision and Use of Work Equipment Regulations 1998 The Management of Health and Safety at Work Regulations 1999 Page 1 of 8

Contents Introduction.... 3 Principles of an LEV system.... 3 User manuals and log books... 4 User manual... 4 LEV system log book... 5 What should be included in a routine inspection?... 5 Examples of what should appear in the log book s checklists include the daily, weekly and monthly for each item in the system for example:... 6 Methods to assess perfomance... 6 Maintenance... 7 Page 2 of 8

Introduction. 1. Local Exhaust Ventilation is complex machinery that requires careful installation, commissioning and on-going maintenance and inspection. LEV should never be modified by anyone other than a competent LEV engineer or designer. 2. LEV will only be installed when there is a significant risk to health from airborne contaminants; dust, mist, fume, vapour or gas. To control these risks LEV must be maintained in an efficient state, efficient working order and in good repair at all times. 3. The Control of Substances Hazardous to Health Regulations 2002 (COSHH) requires that all LEV is subject to a thorough examination and test at specified frequencies (see appendix 1). LEV will also require regular inspections and routine maintenance in addition to the thorough inspection and testing to ensure the equipment is working as intended. 4. A well-designed and implemented regime of maintenance and inspection should identify any faults with the LEV system and prevent equipment failing the thorough inspection and test. 5. In addition to routine maintenance and inspection of LEV systems periodic measurements of the level of contaminant in the air should also be carried out. This should be done at least every 12 months. Principles of an LEV system. 6. LEV is an engineering control system to reduce exposure to airborne contaminants such as dust, mist, fume, vapour or gas in a work place. Most systems have the following components. Air mover Discharge Ducting Air cleaner Hood Inlet Hood Ducting Air cleaner or arrestor Air mover Discharge This is where the contaminant cloud enters the LEV This conducts air and the contaminant from the hood to the discharge point This filters or cleans the extracted air. Not all systems need air cleaning The engine that powers the extraction, usually a fan Releases the extracted air to a safe place. Usually to a collection bag, filter or the atmosphere. Page 3 of 8

7. To work efficiently the velocity of the air at both the hood and in the ducting must be maintained within the design parameters. To ensure this each part of the system has to be working properly with minimal damage, loss of power or function. Routine maintenance and inspection, in addition to the thorough examination and inspections, is the only way to ensure the system remains in good working order. User manuals and log books 8. All LEV systems must have a log book and user manual. The user manual will include commissioning details. The manufacturer should provide these documents when handing over the system. If these documents are not available they must be replaced as they are essential to identifying suitable inspection and maintenance regimes. Replacement documents must be prepared by a competent person i.e. an LEV engineer or an occupational hygienist specialising in LEV. The original supplier may also be able to provide replacement documents. User manual 9. A comprehensive user manual should be in two parts; the first section provides simple getting started instructions. The second section provides detailed technical information for operators and maintenance/ repair engineers. The detailed technical information usually includes: The purpose and description of the LEV system, including diagrams and drawings. How to use the LEV.* The schedule, frequency and description of checks, maintenance and replacement including signs of wear and control failure.* A detailed description of the specific statutory thorough examination and test requirements and benchmarks. The performance information from commissioning. A listing of replacement parts (and numbers). * The content of these sections of a user manual are most relevant to this document and are expanded in Table 1 below. Page 4 of 8

Table 1: Technical information included in the User Manual How to use LEV Inspection checks and maintenance The details of operation and use could The details of checking and maintenance include: should include: Identification of adjustable controls that Ductwork condition, especially flexible affect the system s performance e.g., ducts. dampers. Mechanical integrity, e.g. corrosion, The position of hoods, sash openings damage, seals, dampers, sash etc., for optimum performance. suspensions etc. Operator practice, including positioning Cleanliness of hoods, especially of process equipment and methods of canopies and duct interiors. working. Operation of monitors, air flow Other factors affecting LEV indicators etc. performance such as draughts from Pressure relief or inerting systems, if open doors and the use of additional applicable. fans for cooling. Test for leakage. Illumination in booths and hoods. Noise levels. Alarm systems operating correctly. Water quality, if appropriate. Make-up air without draughts or blockages. List of spare parts required. LEV system log book 10. All LEV systems must have a log book and the log book should be kept up to date. The log book contains: Schedules for regular checks and maintenance. Records of regular checks, maintenance, replacements and repairs. Checks of compliance with the correct way of working with the LEV system. The name of the person who made these checks. What should be included in a routine inspection? 11. The user manual and log book will detail what inspection checks should be carried out and the frequency of these checks. These will have been determined by the designer of the LEV system or, if being prepared for an existing system, an LEV engineer or an occupational hygienist specialising in LEV. 12. The recommendations in the user manual and log book should always be followed unless it can be shown that there is a more suitable process for ensuring, as far as is reasonably practicable, the equipment is in an efficient state, in efficient working order and in good repair at all times. These three requirements have slightly different meanings. Page 5 of 8

Efficient state Efficient working order Good repair General safe condition of the equipment Everything that might have a bearing on safety is working as it should Appropriate repairs and maintenance have been done to the correct standard Examples of what should appear in the log book s checklists include the daily, weekly and monthly checks for each component of the system. For example the: Hoods, including airflow indicators, physical damage and blockages. Ducts, including damage, wear and partial blockage. Dampers position. Air Cleaner, including damage, static pressure across the cleaner and failure alarms. Air mover, including power consumption and changes in noise and vibration. Maintenance carried out. Replacements made. Planned and unplanned repairs. Operator s use of LEV check they are following the correct procedures. Space to report the results of each check against item. Signature and date. Specific examples include: Clearance time for booth. Receiving hood position, particularly for moveable hoods. Capturing hood and working zone within the capture zone. Operator making sure the source is well within a partial enclosure. Clutter obstructing LEV. Checking the fan noise and keeping the impellers clean. Fan bearing replacement. Filter material replacement. Methods to assess performance 13. There are a variety of methods to assess the performance of LEV and the most appropriate method will be described in the user manual. Below is an outline of some of the most common methods. Full enclosures- Measure the static pressure between the interior of the enclosure and the workroom. The pressure in the interior must be lower than the workroom. Partial enclosures Booths/fume cupboards - Measure the face velocity. Readings should not vary excessively. Fume cupboards and safety cabinets should also be further tested according to appropriate BS or EN Standards. Receiving hoods including canopies and capturing hoods - Measure the face velocity. For larger hoods, measure at several points over the face. Readings should not vary excessively. Capturing hoods Slots - Measure the air velocities at equidistant points along the entire length and average the readings. Readings should not vary excessively. Page 6 of 8

Hood static pressure - Measure the hood static pressure. If an airflow monitor is fitted, check the reading is correct. Plenums - Measure the static pressure of the plenum (the enclosure behind certain types of hood) as well as the hood duct measurement. Ducts - Measure the air velocity in the duct serving each hood, where this is possible. Measure in a straight section of duct the measuring point should be well downstream of bends and other turbulence sources. Fan/air mover - Measure the static pressure at the fan inlet and the volume flow rate. Measure the volume flow rate either on the fan inlet or outlet, wherever there is a reasonably straight section of duct the measuring point should be well downstream of bends and other turbulence. For a belt-driven fan, measure the rate of revolution of the fan shaft with a tachometer. See manufacturer s instructions. Filters - Measure the static pressure across the filter. Where a fabric filter has a shakedown cleaning device, operate the shake-down before taking measurements. If the air volume passing through the filter is the same as that through the fan, the filter flow rate need not be measured. Fitted pressure gauges - Check the functioning and accuracy of any fitted pressure gauges. Special filter - Filtration of toxic particles requires a high performance filter, for example high efficiency particle arrestors ( HEPA or absolute filters). Follow an appropriate British, European or ISO standard to test such filters in situ. Wet scrubber - Measure the static pressure at the inlet and outlet, and the water ph if relevant to the scrubbing performance. Maintenance 14. Maintenance tasks will vary and will be detailed in the user manual. Maintenance will be designed to ensure, as far as is reasonably practicable, that the equipment remains in an efficient state, in efficient working order and good repair. As with inspection, maintenance regimes will have been determined by the designer of the LEV, an LEV engineer or Occupational Which specialising in LEV and should be complied with. 15. The UAL H&S Standard The inspection and maintenance of work equipment has more detail about designing maintenance schedules and record keeping. Page 7 of 8

Appendix 1 Frequencies of thorough examination and testing of LEV Process Processes in which blasting is carried out in, or incidental to, the cleaning of metal castings, in connection with their manufacture Processes other than wet processes, in which metal articles, other than gold, platinum or iridium) are ground, abraded or polished using mechanical power, in any room for more than 12 hours a week Processes giving off dust or fume in which non-ferrous metal castings are produced. Other processes Minimum frequency I month 6 months 6 months 14 months Page 8 of 8