More safety for your patient

Similar documents
Supporting you in saving lives!

Safe ventilation at rest and on the move

With INTELLiVENT -ASV, the world s first fully closed loop ventilation. The next era of Intelligent Ventilation

Intelligent Ventilation solution from ICU to MRI

Safe ventilation at rest and on the move

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Minimum size for maximum performance

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

ASV. Adaptive Support Ventilation

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

HAMILTON-C3. The compact high-end ventilator

INTELLiVENT -ASV. The world s first Ventilation Autopilot

HAMILTON-C6. The next generation of intelligent ICU ventilators

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

HAMILTON-G5. The modular high-end ventilation solution

HAMILTON-T1 Intelligent transport ventilation for armed forces

Safe and Intuitive Neonatal Ventilation

fabian Therapy evolution Our 2-in-1 device

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

D Beyond essentials DRÄGER SAVINA 300 SELECT

Blease900 Ventilator PATIENT CENTERED VENTILATION


2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

fabian HFO: Modular, Powerful, Versatile.

Mechanical Ventilation

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

ekom Compressor for Medical Air Sonata with Ekom

Flight Medical presents the F60

Inspiration 7i Ventilator

Focused on essentials DRÄGER SAVINA 300

fabian HFO Our 4-in-1 device

HAMILTON-MR1. Technical specifications HAMILTON-MR1

HAMILTON-C1 neo. Technical specifications

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Advisedly design for all critical juncture. ihope RS/RV Series turbine based ventilatior

D Beyond essentials DRÄGER SAVINA 300 SELECT

evolution 3e Ventilators

IEC C LASSIFICATIONS:

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Hospital and Transport for Controlled Breathing

A9600 Anesthesia Workstation. Your healthcare, we care.

Focused on essentials DRÄGER SAVINA 300

Emergency Transport and Ventilation

How Ventilators Work. Chapter 3

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Monnal T60. Touch and Breathe.

Milestones of Aeonmed Ventilators

GE Healthcare. Aestiva/5. More than superior ventilation

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

D Designed for non-invasive ventilation DRÄGER CARINA

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

An intuitive and innovative answer to your anaesthesia challenges

Potential Conflicts of Interest Received research grants from Hamilton, Covidien, Drager, General lel Electric, Newport, and Cardinal Medical Received

Corporate Overview and Product Summary

Entry to the premium class!

Organis TestChest. Flight Simulator for Intensive Care Clinicians

SLE5000 Infant Ventilator with HFO

ihope Series Ventilator Nov. 2017

Airox Supportair Ventilator

New A7 Anesthesia Workstation

Panther 5 Acute Care Ventilator

Supporting your patients every breath

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Oxylog 3000 plus Emergency & Transport Ventilation

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Selecting the Ventilator and the Mode. Chapter 6

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Setting new trends in ventilation. DRÄGER EVITA INFINITY V500

Dräger Savina Sub-Acute Care Ventilation

Giving neonates a future

MT Excellent performance and reliability EVITA 4 EDITION

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

NEONATAL/INFANT VENTILATOR

Anesthesia Workstation

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Patient Setup Information

The centerpiece of a comprehensive anaesthesia workstation

INTENSIVE CARE VENTILATORS

Technical Data and Specifications

Mechanical Ventilation

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

State-of-the-art anesthesia technology

HAMILTON-C1. Technical specifications

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Lung recruitment maneuvers

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Made to meet your needs DRÄGER SAVINA 300

Apollo Safety Features

Medical Instruments in the Developing World

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Transcription:

The big picture in Intelligent Ventilation

www.hamilton-medical.com/c3 More safety for your patient The world s population is growing. As people are getting older and sicker, the number of ventilated patients in the ICU increases 1,2. The estimated cost for intensive care and mechanical ventilation is expected to increase from 16 billion USD in 2003 to 60 billion USD by 2020 3. The clinical impact will be significant. An increased number of older patients will lead to more complex patient care, while ICUs will be facing a lack of specialized staff 4. Get your ICU ready The 2009 Vienna Declaration 5 by the ESICM Executive Committee stresses the importance of quality and safety for patient care, especially when looking at future demographic changes. The declaration pledges to do what is necessary to provide safe ICU environments and to design safer and more efficient devices and drugs. HAMILTON MEDICAL has the answer As a manufacturer of ICU ventilators, we are committed to supporting this declaration. To do so, we follow the example of other high-risk industries such as aviation and nuclear power in embracing automation and user interface design. 6 The HAMILTON-C3 provides you with: a 12.1 inch high-resolution widescreen display for more information at a glance its unique Ventilation Cockpit that is designed to improve safety through intuitive operation and monitoring proven closed-loop ventilation that automatically applies lung-protective strategies reducing the risk of operator errors and promoting early weaning a single, versatile source of invasive and non-invasive ven- tilation for adults, pediatrics and neonatal ICUs, emer- gency and recovery rooms, subacute care, and intrafacility transport integrated turbine and hot-swappable batteries providing maximum mobility for up to 6.5 hours 1 Needham DM, Bronskill SE, Calinawan JR, Sibbald WJ, Pronovost PJ, Laupacis A. Crit Care Med 2005 Mar;333:574-9. 2 U.S. Census Bureau, Systems Support Division, Last Revised: July 14, 2009 3 Zilberberg M et al. BMC Health Services Research 2008;8:242 4 Prospects: The 2008 Revision. Committee on Quality of Healthcare in America. To Err is Human. Institute of Medicine, 1999. Angus D. JAMA 2000, Martin GS. CCM 2006, Poncet MC. AJRCCM 2007, Embriaco N. AJRCCM2007 5 http://patientsafety.esicm.org/declaration.asp 6 Richard JC, Kacmarek RM. Intensive Care Med. 2009 Oct;35(10):1662-3. The HAMILTON-C3 was designed to provide Intelligent Ventilation, delivering:

Ease of use Visualizing complex information in an intuitive way Improved patient outcome Fully closed-loop ventilation promotes early weaning Efficiency through innovation Reduce the patient s time on the ventilator

www.hamilton-medical.com/c3 Ease of use In mechanical ventilation, monitoring means curves, numbers and more numbers. Conventional ventilation requires significant clinical expertise and numerous manual adjustments. This can be challenging and stressful since respiratory experts cannot be at the bedside all the time. Ventilators clearly need to be simpler to use so the clinician can concentrate on the patient, not the ventilator. See and understand all important information at a glance Our Unique Ventilation Cockpit on the HAMILTON-C3 reduces complexity by visually displaying the patient s respiratory mechanics, current condition and ventilation support in an intuitive way. The HAMILTON-C3 graphically displays this information on a single 12.1-inch high-resolution window, providing you with a continuous ventilation therapy big picture. Proven technology you can trust The HAMILTON-C3 comes with ASV Adaptive Support Ventilation technology which provides major improvements. Conventional modes require you to set numerous parameters. Closed-loop ventilation with ASV adjusts ventilation settings automatically which reduces the risk of human error and improves patient safety. 1 Studies show that ASV : ventilates virtually all intubated patients whether active or passive regardless of their lung disease 2 requires less user interaction, adapts to patient s breathing activity more frequently, and causes fewer alarms 3 adapts to changes in the patient s lung mechanics over time 4 Vt/IBW (ml/kg) 9 8 7 6 ARDS Normal COPD ASV adapts to lung mechanics by automatically applying lower tidal volumes in ARDS patients. The graph shows tidal volumes applied in ARDS patients over 7 days. 4 1 Vignaux L, Tassaux D, Jolliet P. Intensive Care Med. 2009 Oct;35(10):1687-91 2 Arnal JM, Durand-Gasselin J. Intensive Care Med. 2008 Jan;34(1):75-81. 3 Petter AH et al. Anesth Analg 2003;97:1743-50. 4 Adaptive support ventilation (ASV) automatically adapts a protective ventilation in ARDS patients. Arnal JM, Garcin F, Wysocki M, Corno G, Orlando A, Durand-Gasselin J. Intensive Care Med 2006:32 suppl 1: 0452 Simple ventilation setting Set your patient s height and gender, choose your ventilation mode and start ventilation with the optimal setting for controls and alarm limits.

Normal compliance and resistance Low compliance (stiff lung) and high resistance Understand lung mechanics The Dynamic Lung expands and contracts in synchrony with actual breaths. It visualizes in real-time: tidal volume lung compliance resistance patient activity

www.hamilton-medical.com/c3 Improved patient outcome and safety In a root cause analysis of deaths or injuries related to longterm ventilation, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) found that inadequate briefing / training and failure to communicate between staff members were by far the most important causes. 1 As a leading manufacturer of ICU ventilators, transparent patient-centered care is of key importance at HAMILTON MEDICAL when developing new devices. Increased safety of operation The Ventilation Cockpit s 12.1-inch high-resolution widescreen display plays a crucial role in simplifying the operation of the ventilator and the interpretation of monitored data. In addition, the specially designed alarm lamp at the top of the unit ensures that an alarming ventilator is immediately identified, visually, in addition to audibly 2. HAMILTON MEDICAL ventilators are designed to achieve optimum patient compliance with the applied ventilation therapy. For example, reduced sounds and dimmable lights let the patient rest during the night. Optimal synchronization of breath delivery with patient efforts support early and weak patient activities. Monitoring and alarming are adapted to the challenges 3 of non-invasive ventilation. The use of speaking-valves is possible, allowing the patient to communicate with the environment. Lung protective strategies and patient comfort HAMILTON MEDICAL s ASV employs lung protective strategies to minimize complications from AutoPEEP and as a result, 4 volutrauma/barotrauma. ASV also prevents apnea, tachypnea, excessive dead space ventilation, and excessively long breaths. ASV promotes free breathing for patients in all ventilation modes and phases. It encourages spontaneous activ- ity right from the start of ventilation and promotes weaning from first deployment. 5, 6 1 Preventing ventilator-related deaths and injuries. Jt Comm Perspect. 2002 Apr;22(4):14-5. 2 Vignaux L, Tassaux D, Jolliet P. Intensive Care Med. 2009 Okt;35(10):1687-91 3 Tassaux D, P, Jolliet P. Crit Care Med. 2002 Apr;30(4):801-7. 4 Arnal JM, Durand-Gasselin J. Intensive Care Med. 2008 Jan;34(1):75-81. 5 Chen CW, Huang YC. Respir Care. 2011 Jul;56(7):976-83. 6 Jung B, Jaber S. Anesthesiology. 2010 Jun;112(6):1435-43. 7 Gruber et al., Anesthesiology. 2008; 109:81-7 IntelliTrig Changing breathing patterns or circuit leaks are a challenge in non-invasive ventilation. With the innovative IntelliTrig technology, the HAMILTON-C3 automatically responds to varying leaks and adapts sensitivity thresholds for optimal response to the patient s breath.

Understand changes in the patient condition and how ASV reacts The ASV Breathing Map shows how the adaptive lung controller is approaching its targets. It shows both the target and actual parameters for tidal volume, frequency, pressure, and minute ventilation. Reduce time on the ventilator by over 50 % ASV facilitates shorter times on the ventilator: 6 hours with ASV as compared to 14 hours with conventional ventilation. 7 Cumulative rate of extubation 0.0 0.2 0.4 0.6 0.8 1.0 6hrs ASV Control 14hrs 0 2 4 6 8 10 12 14 Time (hours)

www.hamilton-medical.com/c3 Efficiency through innovation Intelligent Ventilation with ASV means fewer days on the ventilator and the use of less-invasive ventilation modes. As a result, clinicians can spend more time with their patients and ensure shorter stays in the ICU. The HAMILTON-C3 lets you optimize clinical resources and skills while reducing cost of ownership and management overhead. Most importantly, it can help reduce the patient s time on the ventilator. Know when to take the patient off the ventilator The Ventilation Cockpit s Vent Status panel provides intuitive visualization of the most important parameters and settings related to patient-ventilator dependency. This innovation helps you decide when to take the patient off the ventilator. Studies have shown that notifying caregivers about the patient s recovery from respiratory failure can significantly reduce the duration and total cost of ventilation. 1 Start weaning at intubation ASV, the closed-loop ventilation system, automatically promotes free breathing for patients in all ventilation modes and phases. It encourages spontaneous activity right from the start of ventilation and promotes weaning from first deployment. Studies show the results: shorter ventilation times (see graph on the previous page). 2,3, 4 At the bedside or during transport: benefit from a double-duty solution The HAMILTON-C3 s compact design and independence from external power and air supplies allow for maximum mobility throughout the hospital. 1 Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF. N Engl J Med. 1996 Dec 19;335(25):1864-9. 2 Kirakli C, Ozkan. Eur Respir J. 2011 Oct;38(4):774-80. 3 Chen CW, Huang YC. Respir Care. 2011 Jul;56(7):976-83. 4 Cassina T, Chioléro R, Mauri R, Revelly JP. J Cardiothorac Vasc Anesth. 2003 Oct;17(5):571-5. Ergonomic and intuitive humidification With the HAMILTON-H900 humid i fi e r,hamilton MEDICAL provides the optimal solution for conditioning patient s breathing air. The HAMILTON-H900 provides you with single-handed disposable replacement and wall heated smoothbore circuits to effectively prevent rainout.

Highly dependent patient Low dependency consider taking the patient off the ventilator. How to know when to take the patient off the ventilator? The Vent Status panel gives you a visual represen tation of 6 parameters related to patient-ventilator dependency, grouped into: oxygenation CO 2 elimination patient activity Since the panel is user-configurable, it helps you enforce your ICU s weaning protocol.

www.hamilton-medical.com/c3 A comprehensive ventilator In addition to its unique features, the HAMILTON-C3 with ASV includes everything you expect from a state-of-the-art ventilation solution, including: a choice of manually and/or fully controlled modes for invasive and non-invasive ventilation an extensive monitoring package the ability to ventilate adult, pediatric, and neonatal patients IntelliTrig With the innovative IntelliTrig technology, the HAMILTON-C3 auto matically responds to varying leaks and adapts sensitivity thresholds for optimal response to the patient s breathing pattern. ASV Adaptive Support Ventilation (ASV) is a closed loop mode based on a breath-by-breath assess, optimize and achieve concept: 1. Assess the patient s lung mechanics. 2. Optimize the tidal volume/respiratory frequency combination based on lung mechanics. 3. Achieve optimum tidal volume/ respiratory frequency by automatically adjusting mandatory rate and inspiratory pressure applying lung-protective strategy rules. IntelliSync Makes ventilation easier and more comfortable for the patient by automatically switching between controlled and spontaneous ventilation. Configurable Ventilation Cockpit The Ventilation Cockpit lets you configure your patient s monitored data the way you want. You can choose from various layouts to display a combination of Intelligent Panels, including Dynamic Lung, Vent Status, and ASV target graphics, plus traditional waveforms. Available Options: Volumetric (Mainstream) CO 2 Sidestream CO 2 NeoNIV (nasal CPAP) TRC DuoPAP/APRV Non invasive ventilation For a complete overview of all features, functions, simulation software and latest news, please refer to: www.hamilton-medical.com/c3

12.1-inch high resolution wide touchscreen and single-knob operation You can operate the HAMILTON-C3 via the touchscreen or by using a single knob. Hard keys give direct access to the most important functions. 360 alarm lamp You can immediately identify an alarming ventilator by the alarm lamp at the top even when you are at a dis- tance or when several devices are operated in the same room. Serial interface for PDMS or patient monitor The serial RS-232 interface provides a port connecting hospital monitors and Patient Data Management Systems (PDMS). Extended battery backup option With the extended battery option, your HAMILTON-C3 can run indefinitely on hot-swappable batteries. With 2 fully charged batteries independent operation of 6.5 hours can be achieved. High-performance, ultra-quiet turbine The turbine can deliver a flow of up to 240 l/min. The flow is precisely dosed by the inspiratory valve. Patented noise reduction allows you to use the HAMILTON-C3 even in an ultra-quiet environment. Flexible device configuration You can con figure the device mounting ways to adapt the HAMILTON-C3 to your environment: on a standard trolley, with optional humidifier and O 2 cylinder mounts with an adaptable plate to any support you like

For further information about the HAMILTON-C3 please contact: HAMILTON MEDICAL AG Via Crusch 8 CH-7402 Bonaduz Switzerland (+41) 81 660 60 10 (+41) 81 660 60 20 www.hamilton-medical.com 689473/01 Specifications are subject to change without notice. INTELLiVENT, ASV and DuoPAP are trademarks of HAMILTON MEDICAL. 2012 HAMILTON MEDICAL AG. All rights reserved. Printed in Switzerland. Special thanks to the Spital Zollikerberg Switzerland.