Math Review. Overview

Similar documents
Dosimetric Calculations. Lonny Trestrail

Review of fundamental photon dosimetry quantities

Monitor Unit Calculations Part 2. Calculation of machine setting. Collimator setting

1. Question Answer cgy / MU cgy / MU 2. Question Answer

Relative Dosimetry. Photons

Monitor Unit Calculations Part 1. Return to our first patient. Purpose. 62 yr old woman with Stage IIIB (T1N3M0) NSCLC rt lower lobe Dose prescription

The Royal Australian and New Zealand College of Radiologists. FRANZCR Examination Part I Radiation Oncology. Radiotherapeutic Physics.

Radiotherapy physics & Equipments

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Field size and depth dependence of wedge factor for internal wedge of dual energy linear accelerator

Commissioning an IMRT System for MLC Delivery. Gary A. Ezzell., Ph.D. Mayo Clinic Scottsdale

Monitor Unit Verification for Small Fields

CHAPTER-2. Wedge filters are the most important beam modifiers used in

3D Treatment Planning and verification with hand calculations

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

OUTPUT at dmax in tissue 8x8 20x20 At 100cm SSD At 100cm SAD

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 4, FALL 2002

Treatment Planning Techniques for Larger Body Habitus Patients for Breast/Chestwall and Regional Lymph Nodal Irradiation

Constancy checks of well-type ionization chambers with external-beam radiation units

Commissioning and quality assurance of a commercial intensity modulated radiotherapy (IMRT) treatment planning system PrecisePLAN

Planning Assignment (3 field rectum)

Clinical Implementation of Volumetric Modulated Arc Therapy

Zoubir Ouhib Lynn Cancer Institute

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

SnapShot IMRT with compensators and FFF beams

CLINICAL IMPLEMENTATION OF RAPIDARC Treatment Planning Strategies to Improve Dose Distributions

WEDGE FILTERS FOR MEGAVOLTAGE ROENTGEN RAY BEAMS

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

ANALYSIS OF OFF-AXIS ENHANCDED DYNAMIC WEDGE DOSIMETRY USING A 2D DIODE ARRAY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

Introduction. Materials and Methods

Introduction. Introduction. The CyberKnife SRS/SBRT System. Introduction. Contour Structures. CyberKnife Components

THE development of more advanced techniques in radiotherapy,

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

1. BEAM MODIFIERS IN RADIOTHERAPY

The dose distribution of medium energy electron boosts to the laryngectomy stoma

A dose delivery verification method for conventional and intensitymodulated radiation therapy using measured field fluence distributions

Scientific Journal of Nuclear Medicine & Radiation Therapy

Absorption measurements for a carbon fiber couch top and its modelling in a treatment planning system

High Speed Direct SAD Radiosurgery Beam Scanner

The Effect of Immobilisation Devices on Radiotherapy Dose Distributions. Alison Gray August 2007

A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimation

Commissioning of Elekta 6MV FFF Versa HD and Pinnacle

A clinical comparison and analysis between conventional MLC based and solid compensator based IMRT treatment techniques

Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy

Treatment plan complexity metrics for predicting IMRT pretreatment. assurance results. Scott Crowe, QUT

A beam-matching concept for medical linear accelerators

Electronic Oncology Systems the Management and the Safety Measures. Hansen Chen, Director, TDSI

Commissioning and periodic tests of the Esteya electronic brachytherapy system

IMRT in clinical practice at the UMC-Utrecht. Utrecht

Iranian Journal of Medical Physics

TG219: IT'S USE, STRENGTHS AND WEAKNESSES

How to Design Medical Accelerator Systems for Reliability: IBA PT System

TEST REPORT BEAMSCAN WITH HALCYON

Clinical Implementation of the IPEM 2003 Code of Practice for Electron Dosimetry

Ultrasound Dose Calculations

7.65 ±0.05 mm of lead. The maximum energy of the bremsstrahlung photons was calibrated using the threshold for the D(-y,n)H reaction at

Commissioning of a new total body irradiation protocol

Comparison of ionization chambers of various volumes for IMRT absolute dose verification

COMPARISON BETWEEN PHYSICAL WEDGES AND VIRTUAL WEDGES IN LINAC

Validation of Treatment Planning Dose Calculations: Experience Working with Medical Physics Practice Guideline 5.a.

GEANT4 SIMULATION OF AN ACCELERATOR HEAD FOR INTENSITY MODULATED RADIOTHERAPY

The MC commissioning of CyberKnife with MLC (Tips and Tricks)

USER MANUAL PROGRAM VERSION 1.0.1

TG-61 deals with: This part of the refresher course: Phantoms. Chambers. Practical Implementation of TG-61:

AAPM s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams

Development of Graphical User Interfaces (GUI) software and database for radiation therapy applications

Practical Course in Reference Dosimetry, National Physical Laboratory February 2014 MV Photon Dosimetry in the Clinic Page 1 of 11

Surface buildup dose dependence on photon field delivery technique for IMRT

Implementation of respiratory-gated VMAT on a Versa HD linear accelerator

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

FLUKA Simulations of Radiation Field in Second Accelerator Tunnel

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

Breast Treatment System REFERENCE MANUAL

Arithmetic with Units of Measure

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

TG-51: Experience from 150 institutions, common errors, and helpful hints

Radiation Producing Machines Radiation Safety Training for X-ray Diffraction Units

Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

Problem 1. A cuboid of length x, width 5 less than x and a height of half the length has a surface area of 250 cm 2. Show that 4x 2 15x 250 = 0

Abstract: Introduction:

Larry A. DeWerd, Ph.D., FAAPM UW ADCL & Dept. of Medical Physics University of Wisconsin

Walk - Run Activity --An S and P Wave Travel Time Simulation ( S minus P Earthquake Location Method)

Exposure System Selection

Firestop Products and Systems Estimating Guide

INTRODUCTION TABLE OF CONTENTS

MIT Analytical X-Ray Safety Policies and Procedures

Perimeter. Perimeter is the distance around a figure. Add to find the perimeter (P) of each figure. P

Disclosures. What Is So Hard? End of ITV: Gating is the Best ITV Killer 8/3/2016. Daniel A. Low, Ph.D. UCLA. Varian Grant Siemens Grant Accuray Grant

COMPASS. Dr. Lutz Müller. AK IMRT Bamberg April D IMRT Verification in Patient Anatomy

Dynamic wedges dosimetry and quality control

39 WAYS TO USE CUISENAIRE RODS VISIT OUR NEW WEBSITE

Density and Archimedes Principle 11-cor

Physics and Quality Assurance

Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator

ON THE RELATIVE ADEQUACY OF SOME AMERICAN CHAMBERS FOR MEASUREMENTS IN THE GRENZ RAY RANGE*

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

LAB 7. ROTATION. 7.1 Problem. 7.2 Equipment. 7.3 Activities

Transcription:

Drawn by Steve Yan, CMD Math Review Shirley Ann Pinegar-Johnston MS RT(R)(T)CMD Overview Drawn by Steve Yan, CMD

Divergence & Intensity DIVERGENCE X-rays travel in Straight but Divergent lines INTENSITY Energy radiated per unit time per unit area

How do we calculate? Divergence Formula calculates the SIZE of the radiation field Inverse Square Formula helps us calculate the INTENSITY of a radiation beam Isocenter Point around which a gantry rotates Intersection of the collimator axis and the axis of rotation

If the field size is 10x15 at 100cm, what is it on a port film at 125cm? 100cm Image Receptor

Divergence If the field size is 10x15 at 100cm, what is it on a port film at 125cm? 100cm from the source 10 cm??? cm Field Size on portal film at 125cm Field width 1 = distance 1 10 = 100 Field width 2 distance 2 x 125 x = 12.5 Field length 1 = distance 1 15 = 100 Field length 2 distance 2 y 125 y = 18.75 Magnification 100cm from the source 10 cm 12.5 cm Field Size on portal film at 125cm Comparing: Field Sizes 12.5/10 = 1.25 or Distances 125/100 = 1.25 Magnification Factor is 1.25

Field length 1 = distance 1 Field length 2 distance 2 40 = 100 56 new SSD (56)(100) = (40)(new SSD) 140cm = new SSD

Divergence Gap Problem Gap = ( field size 1 xdepth ) + (field size 2 xdepth) 2 SSD 2 SSD What is the gap needed between two adjacent fields to a depth of 6cm. The field lengths of the fields are 8cm and 20cm, respectively at 100cm SSD? Gap = ( 8 x 6 ) + (20 x 6 ) 2 100 2 100 (4 x.06) + (10 x.06) Gap =.84cm.24 +.6 (Image from Stanton & Stinson p 242 Applied Physics for Radiation Oncology Revised Edition)

Feathering Initial Plan Used w permission TJU Graduate MD Student 2nd Plan - Feathered 1cm inferiorly 3rd Plan- Feathered additional 1 cm inferiorly

Used w permission TJU Graduate MD Student Feathering - CSI

Inverse Square Law states that the intensity is inversely proportional to the square of the distance from the source Inverse Square Formula Intensity 1 = (Distance 2 ) 2 Intensity 2 (Distance 1 ) 2 OR (Distance where Intensity is KNOWN) 2 x Intensity (Distance where Intensity is UNKNOWN) 2

Inverse Square Problem If the Intensity at 100cm is 200cGy, what is the Intensity at 50cm? 50cm??cGy 100cm 200cGy Inverse Square Problem If the Intensity at 100cm is 200cGy, what is the Intensity at 50cm? Intensity 1 = (Distance 2 ) 2 Intensity 2 (Distance 1 ) 2 200cGy = (50) 2 = Intensity at 50cm = 800cGy x (100) 2 (Distance where Intensity is KNOWN) 2 x Intensity (Distance where Intensity is UNKNOWN) 2 (100) 2 X 200cGy = Intensity at 50cm = 800cGy (50) 2

Drawn by Steve Yan, CMD Definitions Isocenter Point around which a gantry rotates Intersection of the collimator axis and the axis of rotation

SSD - SOURCE TO SKIN DISTANCE Source CENTRAL AXIS SSD 100cm SSD Field size is defined at SKIN surface SAD SOURCE TO AXIS DISTANCE SOURCE SAD 100cm CENTRAL AXIS SSD 92cm SSD + depth = SAD Field size is measured INSIDE the 92 + depth = 100 patient

Elapsed Days Elapsed Days Example Sun Mon Tues Wed Thur Fri Sat No Rx 180cGy 180cGy 180cGy 180cGy 180cGy No Rx No Rx 180cGy 180cGy 180cGy 180cGy 180cGy No Rx This chart shows 10 fractions at 180cGy per fraction over how many elapsed days?

Is the first treatment day considered Day 0 OR Day 1 Elapsed Days Example Sun Mon Tues Wed Thur Fri Sat No Rx 180cGy 180cGy 180cGy 180cGy 180cGy No Rx Day 0 Day 1 Day 2 Day 3 Day 4 Day 5 No Rx 180cGy 180cGy 180cGy 180cGy 180cGy No Rx Day 6 Day 7 Day 8 Day 9 Day 10 Day 11

Equivalent Square Find the equivalent square for a rectangular treatment field Sterling s Formula FS eq. 4 Area Perimeter 14 cm 10 cm Example 1 FS eq. 4 Area Perimeter L x W 2 (L + W) or sum of sides 10 x 14 = 140 = 2.917 2(10 + 14) 48 4 x 2.917 FS eq. 11.667 cm

10 cm 2 cm 14 cm 3 cm Example 2 Area FS eq. 4 Area Perimeter (10 14) (2 2) (3 3) Perimeter 8 2 2 12 7 3 3 11 FS eq. 127 4 48 FS eq. 10.58 cm L x W 2 (L + W) or sum of sides

Can Swing Over Short Grenz Ray < 10-15 KvP HVL in mm AL Contact Therapy 40-50 KvP HVL mm AL Superficial 50-150 Kvp Orthovoltage 1921 HVL in mm AL 150-500 KvP HVL in mm Cu uses Thoreaus filter Tin, Copper, Aluminum from tube to patient Supervoltage 500-1000 Kvp Megavoltage 1961 > 1000 KvP HVL in mm Pb Image from Selman s The Basic Physics of Radiation Therapy 2 nd edition

Some D/Max Depths to Know Beam Energy Cobalt 60 4Mv 6Mv 10Mv 18Mv D/Max Depth.5cm 1.0cm 1.5cm 2.0cm 3.0cm Remember: D/max Depth is Primarily dependent on Beam Energy Effect of Energy on Isodose Curves **Normalized to D/Max Measured in Water Phantom** 60 Co 4Mv Build-Up Region Penumbra Image from Radiation Therapy Planning 2 nd Edition Gunilla C. Bentel 6Mv 15Mv

6Mv Beam From Bentel 2 nd edition p 101 Example of DVH DVH would be used to look at doses to normal structures/volume For example: Lung volume receiving https://www.google.com/search?q=lung+dvh&rlz=1c1ggrv_enus754us754&tbm=isch&source=iu&ictx=1&fir=rbzx6voirkuppm%253a%252camlqva4gyqf3em%252c_&usg= JpGDmM3S6 2KLoii8K6bSE8MHheQ%3D&sa=X&ved=0ahUKEwjA54GC2KvbAhVG2lMKHcfPAYcQ9QEIPzAB#imgrc=RbzX6VoiRkuPPM:

Beam Energy Whole Brain Equal dose from R/L Lateral 6Mv 15Mv Beam Weighting When the dose from EACH beam is the same, the beams are said to be Equally Weighted Different doses from EACH beam is called Unequally Weighted For example: AP:PA :: 2:1 dose ratio Anterior (120cGy) 2x + 1x = 180cGy 3x = 180cGy x = 60cGy Posterior (60cGy) Stanton & Stinson p261

3DCRT 3-Field Rectum Posterior Lateral Generally, a LOW Beam Energy was considered for the POSTERIOR Field HIGH Beam Energy was used on LATERAL Fields Monitor Units Calculations PDDs TARs/ TMRs Irregular Field

Percentage Depth Dose (PDD or %DD) Ratio of Dose at Depth compared to the dose at D/Max expressed as a percentage PDD at D/Max for ANY field Size, SSD, Beam Energy is 100% = 1.00 (decimal form)

PDD Table for 6Mv Factors Affecting PDD Field Size Beam Energy - Go deeper into patient - PDD Source to Skin Distance - (Mayneord s F Factor) **Mayneord s F Factor Calculation is no longer tested in the RTT Exam**

Percentage Depth Dose (PDD or %DD) Ratio of Dose at Depth compared to the dose at D/Max expressed as a percentage Mayneord s F Factor This is used when there is a change in the SSD from the chart. It is an application of the INVERSE SQUARE LAW!! F = (old SSD + depth) 2 X (new SSD + D/Max) 2 (old SSD + D/Max )2 (new SSD + depth) 2 F x old %DD value = %DD at new SSD

Radiation Source Calculate the adjusted PDD value for a 60 Co machine using a treatment SSD of 110cm for a field size of 10x10 depth 5cm ****DO PROBLEM***** F = (old SSD + depth) 2 X (new SSD + D/Max) 2 (old SSD + D/Max )2 (new SSD + depth) 2 F x old PDD (.751) = new PDD at 125cm SSD Monitor Unit (MU) Calculations Using PDD MU = Tumor Dose Reference Dose Rate x Sc x Sp x PDD x (any other factors as needed) (at distance of Rx SSD + D/Max)

Monitor Unit Calculations Using PDD SOURCE SSD Field Size measured on SKIN Reference Dose Rate at SSD + D/max Reference Field Size generally 10x10 Scatter (Output) Factor This factor adjusts the machine output when the Treatment Field Size is different than 10x10 If the Field Size is greater than 10x10, the Output Factor will be GREATER than 1.0 (more scatter) If the Field Size is smaller than 10x10, the Output Factor will be Less than 1.0 (less scatter) The Output Factor can be subdivided into Collimator Scatter (Sc) and Phantom Scatter (Sp) Tumor Dose Reference Dose Rate x Sc x Sp x PDD x (any other factors as needed) (at distance of Rx SSD + D/Max)

Scatter Factor Tables 10x10 Reference Field Size Table from Washington & Leaver Monitor Unit Calculations Using PDD MU = Tumor Dose Reference Dose Rate x Sc x Sp x PDD x (any other factors as needed) (at distance of Rx SSD + D/Max)

Monitor Units Calculation Using PDD Calculate the MU necessary to deliver: 200cGy to a depth of 3cm (PDD value = 95.1%) 10x10 field size 6Mv Linear Accelerator 100cmSSD Reference Dose Rate at 101.5cm from source is 1.0cGy/monitor unit Scatter Factor Tables 10x10 Reference Field Size Table from Washington & Leaver

PDD Table for 6Mv Monitor Units Calculation Using PDD 6Mv Linear Accelerator 200cGy = 210.3 MU 1.0cGy/MU x 1.0 x 1.0 x.951 Reference Dose Rate at Sc Sp PDD (in decimal form) Rx SSD + D/max (100 + 1.5cm)

Dose to Another Point Along CAX Using PDD To calculate the dose at some point along the central axis use direct proportion. Dose at Point A = Dose at Point B %DD at Point A %DD at Point B Problem: For a 6Mv beam, what is the dose to the depth of 5cm when the dose at 3cm is 200cGy? PDD value at D3 =.951 PDD value at D5 =.876 Dose to Another Point Along CAX Using PDD Hint: Since 5cm depth is further AWAY from the source, the dose would be LESS than the dose at 3cm Source CENTRAL AXIS SSD 100cm D/max 200cGy at 3cm PDD =.951?? cgy at 5cm. PDD =.876

Dose to Another Point Along CAX Using PDD PDD value at D3 =.951 PDD value at D5 =.876 Dose at D3 = Dose at D5 PDD at D3 PDD at D5 200cGy = x.951.876 dose at 5cm Depth x = 184.23 cgy Dose to Another Point Along CAX Using PDD Problem: For a 6Mv beam, what is the dose to the D/Max when the dose at 3cm is 200cGy? PDD value at D3 =.951 Dose at D3 = Dose at D/Max PDD at D3 PDD at D/Max

Dose to Another Point Along CAX Using PDD Hint: Since 1.5cm depth (D/max depth for 6MV) is closer TOWARDS the source, the dose would be MORE than the dose at 3cm Source CENTRAL AXIS SSD 100cm D/max??? Dose at D/max... PDD = 1.00 200cGy at 3cm. PDD =.951 Dose to Another Point Along CAX Using PDD Problem: For a 6Mv beam, what is the dose to the D/Max when the dose at 3cm is 200cGy? PDD value at D3 =.951 Dose at D3 = Dose at D/Max PDD at D3 PDD at D/Max 200cGy = x.951 1.00 dose at D/Max x = 210.30 cgy

Dose to Another Point OFF CAX Using PDD Image and Text from Radiation Therapy Planning 2 nd Edition Gunilla C. Bentel

Tissue to Air Ratio (TAR) Developed by Johns to be used in Rotational Therapy Rotational Therapy has the gantry moving DURING the treatment while the beam is ON. A full 360 0 treatment is called a Rotation Any treatment < 360 0 is called an arc Tissue Air Ratio (TAR) ****TAR at D/Max is also called Back Scatter Factor****

Factors Affecting TAR Field Size Beam Energy - Go deeper into patient - ****Source to Skin Distance DOES NOT AFFECT TAR (~2% accuracy)**** 6Mv TAR 0 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 24 26 28 30 32 35

Monitor Unit Calculations Using TAR SOURCE SAD 100cm CENTRAL AXIS SSD 82cm **Machine Output AND Field Size measured at Treatment SAD** Monitor Units Calculation Using TAR 6Mv Linear Accelerator Calculate the MUs necessary to deliver 180cGy to a 5cm depth TAR at D5 = 95.2% 10x10 field size 100cmSAD 6Mv Linear Accelerator Machine output at 100cm from source is 1cGy/MU

Monitor Unit Calculation Using TAR MU = Tumor Dose Machine output x S c x TAR x (any other factors as needed) (at distance of Rx SAD) Monitor Units Calculation Using TAR 6Mv Linear Accelerator 180 1.0cGy/MU x 1.0 x.952 = 189.08 MU machine output at Rx SAD S c TAR

PDD vs. TAR/TMR PDD was commonly used when SSD techniques were prevalent in radiotherapy. The use of 3DCRT and IMRT have required SAD treatment to become standard, and TAR/TMR is a more straightforward calculation system when using SAD treatment (SSD independent) As a rule on the exam, anytime a SSD treatment is mentions, use a PDD. For SAD treatments, use TAR or TMR Tissue Maximum Ratio Because of Measurement difficulties, the TMR was developed. The SAME factors which influence TAR, affect TMR in the same way

TAR compared to TMR Tissue to Air Tissue Air Ratio **************************************************************** epth of Interest Tissue Maximum Ratio Factors Affecting TMR Field Size Beam Energy - Go deeper into patient - ****Source to Skin Distance DOES NOT AFFECT TMR (~2% accuracy)****

Monitor Units Calculations Using TMR Calculate the MUs necessary to deliver 180cGy to a 5cm depth 10x10 field size 100cmSAD TMR = 97.7% 6Mv Linear Accelerator Machine output at 100cm from source is 1cGy/MU Monitor Units Calculation Using TMR MU = Tumor Dose Machine output x Sc x Sp x TMR x (any other factors as needed) (at distance of Rx SAD)

Monitor Units Calculation Using TMR 6Mv Linear Accelerator 180 1.0cGy/MU x 1.0 x 1.0 x.977 = 184.24 MU machine output at Rx SAD Sc Sp TMR Gantry Speed for Rotational Treatments

Speed of Gantry for Rotational Treatment To set speed of gantry during a moving field treatment Treatment Monitor units number of degrees of treatment arc Problem for the Speed of the Gantry for Rotational Treatment What would be the monitor units per degree (aka speed of gantry) when The monitor units is 255 for an anterior arc of 180 degrees? Treatment Monitor units number of degrees of treatment arc 255/180 = 1.4166 = 1.42 MU/degree

Where is the FINISHING angle for the arc? 0 270 90 180 If the MU are 255 and the MU/degree is 1.42 and the gantry starts at gantry angle of 270, travels clockwise WHERE is the FINISHING (aka STOP) gantry angle for this treatment? Where is the FINISHING angle for the arc? 1. Determine the number of degrees in the arc Treatment Monitor units number of degrees of treatment arc = gantry speed 255 = 1.42?????? = 180 degrees in the arc 2. Look at gantry angle orientation AND direction of the gantry movement

Where is the FINISHING angle for the arc? 0 START here 270 90 180 AND.the FINISHING angle is.

Blocking/MLC Kahn s 4 th Edition BLOCKS Shape the Radiation Field to shield/protect normal tissues Must be at least 5 HVL thick to allow < 5% transmission Made of Cerrobend (Lipowitz s metal) Bismuth, Lead, Tin & Cadmium Main Advantage Low Melting Point

Cerrobend Ratio to Lead Since cerrobend is a Lead alloy, we need MORE cerrobend to do the same shielding as Pure Lead ***1.25 cm Cerrobend ~ 1.00cm Pure Lead*** Problem: How much cerrobend is needed for blocks to be used on a machine whose HVL = 1.1cm Lead? 1.25 x 1.1= 1.375cm cerrobend x 5 = 6.875cm

Tray Factor Amount of Transmission through the plastic tray which holds the Cerrobend blocks Dose With Tray in place = 97cGy Dose Without Tray = 100cGy Transmission Factor = 97/100 =.97 (Same concept can be applied to compensator/physical wedges) Clarkson Calculation Also called Irregular Field Calculation corrects for the lack of scatter due to blocking The Tissue Air Ratio value needed to calculate the Monitor Unit, is made up of contributions from both the Primary radiation - 0x0 field size (TAR 0 ) when e- hits target, photons produced = primary beam added to scatter (SAR) TAR = TAR 0 + SAR

6Mv TAR 0 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 24 26 28 30 32 35 TAR for 15x15 (open field) at 10cm depth =.844 TAR 0 for 0x0 at 10cm depth =.676 TAR = TAR 0 + SAR.844 =.676 + SAR.844 -.676 = SAR.168 = SAR

Clarkson Calculation 1. Divide Field into Segments 2. Look up SAR value for EACH Radius Length 3. Get Average SAR value 4. Add Average SAR value to TAR 0 5. Use adjusted TAR value for MU Calculation Image from Bentel Radiation Therapy Planning 2 nd Edition p.94 Drawn by Steve Yan, CMD Wedges

Wedges The most FREQUENTLY used Beam Modifying Device The Physical wedges are shaped like a foot. Thick edge is called HEEL. Thin edge is called TOE (Image from Kahn The Physics of Radiation Therapy 4 th Edition p 182) Dynamic Wedge The upper collimator moves DURING the treatment giving a wedge effect

Wedge Angle Wedge Angle angle through which an isodose curve is tilted at the central ray of a beam at a specified depth. The range of wedge angles is generally 15-60 degrees. wedge angle formula = 90 (.5 x hinge angle) Kahn wedge angle measurements recommended to be measured at 10cm depth 15 degree wedge 30 degree wedge 45 degree wedge 60 degree wedge

Hinge Angle Hinge Angle angle between the central rays of two fields optimum hinge angle = 180 (2 x wedge angle) (Image from Stanton & Stinson p242 Applied Physics for Radiation Oncology Revised Edition) Wedge Problems Determine the wedge angle to be used with a 150 0 hinge angle wedge angle formula = 90 (.5 x hinge angle) = 90 (.5 x 150) = 90 (75) = 15 0 wedge angle Determine the optimum hinge angle to be used with 15 0 wedges optimum hinge angle = 180 (2 x wedge angle) = 180 (2 x 15) = 180 (30) = 150 0 hinge angle

Wedge & Hinge Angles Table Wedge Angle Hinge Angle 15 150 30 120 45 90 60 60 Wedge Factor Amount of Transmission through the physical wedge Dose With Wedge in place = 68cGy Dose Without Wedge = 100cGy Transmission Factor = 68/100 =.68 68% of beam TRANSMITTED through wedge 32% of radiation is attenuated

ALMOST Done. Electrons Electrons are generally used for boost treatments To determine the approximate depth of an electron isodose line to cover the deepest part of a tumor, the following rules of thumb can be used: Therapeutic Range Practical range Mev/4 ~ depth of 90% isodose line Mev/3 ~ depth of 80% isodose line Mev/2 ~ depth of 10% isodose line Khan 90% IDL Mev/3.2 80% IDL Mev/2.8

Electron Problem Determine the appropriate electron energy to treat a tumor at 4cm depth if the physician wants to treat to the 80% isodose line. (Image from Stanton & Stinson p242 Applied Physics for Radiation Oncology Revised Edition) Electron Problem 4cm to be covered by 80% IDL Available electron Energies: Rule of Thumb Mev/3 ~ depth of 80% isodose line 7Mev 10Mev 13Mev 16Mev 7Mev/3 = 2.33cm 10Mev/3 = 3.33cm 13Mev/3 = 4.33cm

Any Questions? Contact Shirley.Johnston@jefferson.edu