BACnet Protocol Implementation Conformance Statement

Similar documents
Product Model Number: Applications Software Version: Firmware Revision: BACnet Protocol Revision: 1.14

AN-140. Protege WX SALLIS Integration Application Note

HART Communications Board

HyperSecureLink V6.0x User Guide

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Using MATLAB with CANoe

PRODUCT MANUAL. Diver-MOD

AGW SYSTEMS. Blue Clock W38X

Bidirectional Forwarding Detection Routing

Meter Data Distribution Market Trials

Help Manual. (ROAD Edition)

Typical Wayside Reader System Quotation

Operational Settings:

M-BUS communication protocol

Laboratory 2(a): Interfacing WiiMote. Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments)

Help Manual. (ROAD Edition)

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

Electronic Volume Correctors

Track and Field Interface

Control System Nur Istianah-THP-FTP-UB-2014

High usability and simple configuration or extensive additional functions the choice between Airlock Login or Airlock IAM is yours!

Global Information System of Fencing Competitions (Standard SEMI 1.0) Introduction

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

XC2 Client/Server Installation & Configuration

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700

Help Manual. (ROAD Edition)

PRODUCT MANUAL. Diver-DCX

Connect with Confidence NO POWER NO PROBLEM

ICD-10-CM IN VERSION 10

How to Download a Red App

QuantityWare Working Paper. NGL & LPG Measurement Standard Comparison

Help Manual. (MTB Edition)

Dräger X-dock Frequently Asked Questions

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

JACE Drivers. Niagara: Andover Infinity Niagara: ASI Driver for Jace 7 (Maxline)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

APP NOTES Onsight Connect Cisco Integration. July 2016

Technical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003

Oracle Utilities Meter Data Management Release Utility Reference Model MDM.Manage VEE and VEE Exceptions

VMware Inc., NSX Edge SSL VPN-Plus

Diver Training Options

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Mac Software Manual for FITstep Pro Version 2

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

Sales Create Outbound Delivery from Sales Order S01- Lean Baseline Package

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

CLUB REGISTRATION & SUPPORT / TICKETING

Wind Plant Operator Data User's Guide

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Sales Quotation For: Tyler Software & Related Services. City of Cape Girardeau Page 1 of 9

An STPA Tool. Dajiang Suo, John Thomas

5) Match timer: Hanged on the court, display the match time synchronous with scoring system.

Chapter 22 Testing Protocols

Residential Ultrasonic Gas Meters

TYPE DOSAODOR-D SOFTWARE FOR CONFIGURATION OF TYPE DOSAODOR-D ODORANT INJECTION SYSTEM

STARLOG. Capacitive Water Depth Probe

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Microsoft Windows Software Manual for FITstep Stream Version 4

On interoperability and seamless within the context of SWIM

Smart Card based application for IITK Swimming Pool management

TH-1800-T TRX-700-CNG Converter

General Specifications

HumiSys HF High Flow RH Generator

Ingersoll Rand. X-Series System Automation

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

SonoSelect 10 and SonoSafe 10 energy meters

LED Proposal for Basketball Stadium

Burner Management System DEMO Operating instructions

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Veronafiere ottobre Gli atti dei convegni e più di contenuti su

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

GNX 20/21 Owner s Manual

[XACT INTEGRATION] The Race Director. Xact Integration

WORLD LEADER IN ALTERNATIVE FUEL SYSTEMS CALIBRATION PARAMETERS

CLI Mapping Reference

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Mass Flow Controller (MFC) for Gases

CNC Communication Protocol

LT GasAnalyzer beyond standards

TA Instruments Installation Requirements for the Thermal Discovery Series

Meter Data Distribution User Manual

SWIM MEET MANAGER 5.0 NEW FEATURES

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Application Instruction Manual

High Ping Rate Profile Water Mode 12

Flow Vision I MX Gas Blending Station

Configuring Bidirectional Forwarding Detection for BGP

NASCAR Media Group CASE STUDY: LOCATION: Charlotte, NC GOAL: SOLUTION:

SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products

RELEASE NOTES Onsight Connect for ios Software Version 8.1

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

Wärtsilä ELAC VE 5900

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

Product Overview. Product Description CHAPTER

Introducing Version 7R2

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

PRODUCT MANUAL. Diver-Mobile for Android

Courseware Sample F0

Transcription:

Page 1 of 10 BACnet Protocol Implementation Conformance Statement Date: September 28, 2016 Vendor Name: Vendor ID: 85 Product Name: savic-net Product Model Number: BS-700 models Application Software Version: 1.0 Firmware Revision: 11.2.6.13528 BACnet Protocol Revision: 12 (135-2010) Product Description The savic-net is a suite of Building Management System Software that can act as a BACnet Operator Workstation (B-OWS). The savic-net is able to communicate with BACnet devices via BACnet-/IP. BACnet Standardized Device Profile (Annex L) BACnet Operator Workstation (B-OWS) BACnet Advanced Operator Workstation (B-AWS) BACnet Operator Display (B-OD) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA)

Page 2 of 10 BACnet Interoperability Building Blocks supported (Annex K) BIBBs Support Data Sharing DS-RP-A ReadProperty-A DS-RP-B ReadProperty-B DS-RPM-A ReadPropertyMultipule-A DS-WP-A WriteProperty-A DS-WP-B WriteProperty-B DS-WPM-A WritePropertyMultipule-A DS-V-A View-A DS-M-A Modify-A DS-COV-A COV-A DS-COVP-A COVP-A Alarm & Event AE-N-A Notification-A AE-ACK-A ACK-A AE-ASUM-A Alarm Summary-A AE-ESUM-A Enrollment Summary-A AE-INFO-A Information-A AE-AS-A Alarm Summary-A AE-VM-A View and Modify-A AE-VN-A View Notifications-A Scheduling SCHED-A Scheduling-A SCHED-VM-A View and Modify-A Trending T-VMT-A View and Modify Trends-A T-V-A View-A Device & Network DM-DDB-A Dynamic Device Binding-A Management DM-DDB-B Dynamic Device Binding-B DM-DOB-B Dynamic Object Binding-B DM-ANM-A Automatic Network Mapping-A DM-ADM-A Automatic Device Mapping-A DM-LM-A List Manipulation-A DM-LM-B List Manipulation-B DM-MTS-A Manual Time Synchronization-A DM-TS-A Time Synchronization-A DM-UTC-A UTC Time Synchronization-A

Page 3 of 10 Segmentation Capability Segmented requests supported Segmented responses supported Window Size: Configurable Window Size: Configurable Standard Object Types - The savic-net as BACnet server Optional Device Yes No Location Description Max_Segments_Accepted Local_Time Local_Date UTC_Offset Daylight_Savings_Status APDU_Segment_Timeout Time_Synchronization_Recipients UTC_Time_Synchronization_Recipients Time_Synchronization_Interval Align_Intervals Interval_Offset - - The savic-net as BACnet client The following description defines all objects that the savic-net is able to read as a BACnet client. That doesn t mean these objects may be present in the savic-net. Optional Access-credential Yes No All Yes *1 Access-door Yes No All Yes *1 Access-point Yes No All Yes *1 Access-rights Yes No All Yes *1 Access-user Yes No All Yes *1 Access-zone Yes No All Yes *1 Accumulator Yes No All Yes *1 Analog-input Yes No All Yes *1 Analog-output Yes No All Yes *1

Page 4 of 10 Optional Analog-value Yes No All Yes *1 Averaging Yes No All Yes *1 Binary-input Yes No All Yes *1 Binary-output Yes No All Yes *1 Binary-value Yes No All Yes *1 Bitstring-value Yes No All Yes *1 Calendar Yes No All Yes *1 Characterstring-value Yes No All Yes *1 Command Yes No All Yes *1 Credential-data-input Yes No All Yes *1 Date-pattern-value Yes No All Yes *1 Date-value Yes No All Yes *1 Datetime-pattern-value Yes No All Yes *1 Datetime-value Yes No All Yes *1 Device Yes No All Yes *1 Event-enrollment Yes No All Yes *1 Event-log Yes No All Yes *1 File Yes No All Yes *1 Global-group Yes No All Yes *1 Group Yes No All Yes *1 Integer-value Yes No All Yes *1 Large-analog-value Yes No All Yes *1 Life-safety-point Yes No All Yes *1 Life-safety-zone Yes No All Yes *1 Load-control Yes No All Yes *1 Loop Yes No All Yes *1 Multi-state-input Yes No All Yes *1 Multi-state-output Yes No All Yes *1 Multi-state-value Yes No All Yes *1 Network-security Yes No All Yes *1 Notification-class Yes No All Yes *1 Octetstring-value Yes No All Yes *1 Positive-integer-value Yes No All Yes *1 Program Yes No All Yes *1 Pulse-converter Yes No All Yes *1 Schedule Yes No All Yes *1 Structured-view Yes No All Yes *1

Page 5 of 10 Optional Trend-log Yes No All Yes *1 Trend-log-Multiple Yes No All Yes *1 Time-pattern-value Yes No All Yes *1 Time-value Yes No All Yes *1 *1: According to the datatype (primitive data types). Data Link Layer Options BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ATA 878.1, EIA-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: BACnet/Zigbee (Annex O): Other: Device Address Binding: Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No Networking Options: Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc.: Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Does the BBMD support network address translation? Yes No Character Sets : Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (UCS-4) JIS X 0208 (JIS C 6226) ISO 10646 (UTF-8)

Page 6 of 10 Network Security Options: Non-secure Device is capable of operating without BACnet Network Security Secure Device is capable of using BACnet Network Security (NS-SD BIBB) Multiple Application-Specific Keys Supports encryption (NS-ED BIBB) Key Server (NS-KS BIBB) Trademark information: savic-net is a trademark of in Japan or in other countries. LonTalk is a trademark of Echelon Corporation registered in the United States and other countries. Copyright 2016 by All rights reserved. No part of this documentation may be reproduced or transmitted in any form or by any means without permission from.