Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Similar documents
Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Cover headline. Cover subheadline. Check Valves

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

PRESSURE COMPENSATORS TECNORD

Directional Controls

Directional Controls

Leak-Free Load-Control Valve SAE ½ psi flange

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Leak free Pipe Rupture Valve for Excavators

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Pilot Operated Check Valves Catalog Quick Reference

Double Pilot Operated Cartridge Check Valve, Size 8

Motion Controls Valve locator

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Chapter 10: Bidirectional Flow Controls

SystemStak Valves. ISO4401 Size 02

3-Way Pressure-Reducing Cartridge, Size 2 4

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

P.C. Flow Regulator Valve Series FR101. General Description

Electrically Operated Pressure-Relief Cartridge, Size 10

Axial piston pumps type PVC

Axial piston pumps type PVC

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Inverse Proportional Pressure-Relief Cartridge, Size 10

Proportional Throttle Cartridges, Size 16

ANTI SHOCK RELIEF VALVE

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

IFP C175-* REMOTE CONTROL RELIEF VALVE

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Full Range Pressure Compensating Variable Flow Control

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Lesson 6: Flow Control Valves

Pressure Reducing Valves Catalog Quick Reference

Directional Control Valves Technical Information Model 1500

Pressure reducing valve, direct operated

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Cooler-Bypass Thermostat Valve, Size 16

directional control valve series cv691

Proportional Pressure-Relief Cartridge Valve, Size 2...4

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Inverse Prop. Pressure-Relief Cart., Size 2 4

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Leak-Free Load-Control Valve, Size 20

BACK PRESSURE / SUSTAINING

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

PVQ 13 A2 R SE 1 S 20 C-11 D

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Inverse Proportional Pressure-Relief Cart., Size 2 4

BACK PRESSURE / SUSTAINING

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Pressure reducing valve, direct operated

2-way flow control valve Model 2FRM 6

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Precision and Instrument Regulators 1/4" port size

Target Cleanliness Worksheet. Systemic Contamination Control

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Monoblock Directional Control Valve RMB 202

Pilot Operated Check Valves

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Models 106-RF / 206-RF Rate of Flow Control Valve

Pressure-Relief Cartridge Valve, Size 4

Directional Valves. Hydraulic Operated Directional Valves

Air preparation units

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Controllers DR, DP, FR and DFR

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Inverse Proportional Pressure-Relief Cart., Size 2 4

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

Fixed Displacement Plug-In Motor A2FE

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Cartridge Valves Technical Information Proportional Valves Quick Reference

Rate of Flow Valve Series 120

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

Bermad Pressure Reducing. Model: 42T

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Cartridge Valves Technical Information Motor Mount HICs Quick Reference

OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE

Transcription:

Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7

ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min (USgpm) PGE Introduction Pressure control functions pplication examples Flow control functions 5 Directional control functions 8 Three-way bridge / Four-way bridge 9 PS () 8 () PS 6 () () PS PS Pressure compensator () 89 (5) () 8 () 6 PS 6 () () 8 PS () 89 (5) MOS MOS 6 Modulating orifice () 8 ( ) () ( 5) DPS 9 () 6 (5) 6 DPS 6 Differential pressure sensing valve 9 () 89 (5) 8 DPS 9 () (8) DPS Spool type functional symbols DPS Poppet type functional symbols -**-(S) -**- Standard cavity dimensions 5 -**-S luminum housings 6 Supporting products Roughing & Finishing tools 7 pplication data 8

Introduction For over 7 years, Vickers has provided its customers with quality products and innovative solutions for all their power and motion control needs. The products featured in this catalog represent the very best in screw-in cartridge logic element valve technology. We are committed to maintaining this position by offering the most comprehensive range of cartridge valves for industrial and mobile equipment. This catalog gives basic specifications for Vickers logic elements screw-in cartridge valves. Its purpose is to provide a quick, convenient reference tool when choosing Vickers cartridge valves or designing a system using these components. ll cartridges have hardened and ground poppets and sharp-edged ground steel seats. This provides an excellent product that is dirt-tolerant, has reliable seating, and is suitable for fast cycling with long life. These Vickers cartridges provide the system designer with a versatile range of elements for use in MD packages for controlling pressure, flow and direction. The range includes: Pressure compensators (hydrostats) Pressure compensators with priority and bypass outlets Differential pressure sensing elements Flow modulated orifice cartridges The correct selection of these products can enhance machine performance, shorten the design process and minimize manufacturing costs of manifold blocks. Flow compensators (hydrostats) PS n essential component of a pressure compensated flow control which, with an external fixed or variable orifice, provides the required compensated flow characteristic. Excess flow is diverted at maximum system pressure. Excess fluid upstream must be diverted e.g. through a relief to tank. Pressure compensator with priority and bypass outlets PS Similar in function to the PS. The major difference is that excess flow is diverted at priority flow pressure, instead of at maximum system pressure, as is the case with PS compensators. The excess flow can pass to a secondary circuit or to tank. Flow modulated orifice cartridges MOS The MOS cartridges are used as modulated orifices. These cartridges are particularly effective when used with an external pressure compensator (hydrostat) such as a PS or PS type. The PS provides normal pressure compensation. The PS provides pressure compensation for priority flow arrangements. The low pilot pressure required allows proportional control when used with an EPV proportional pilot relief. DIfferential pressure sensing elements DPS For controlling pressure, flow or direction (including - and -way bridge circuits) the DPS is used with the aid of external pilot operators. The DPS elements are function building blocks which respond to pressure differential signals, providing the capacity to switch or modulate flows up to l/min (8 USgpm) and pressure to 5 bar (5 psi). The choice of pilot arrangements related to DPS variants can minimize the number of construction holes in a manifold, simplifying design and reducing costs.

pplication Examples Pressure control functions Pressure relief or Sequence example With external pilot supply and pilot relief Pressure relief or Sequence example, normally open With internal pilot supply and pilot relief Pilot pressure source Fixed restrictor Uni-directional flow Pilot relief valve DPS-**-P differential pressure sensing cartridge Uni-directional flow Pilot relief valve DPS-**-V differential pressure sensing cartridge Pressure reducing example Non-relieving type Pilot relief valve DPS-**-R differential pressure sensing cartridge Uni-directional flow

Flow control functions Pressure compensated flow control example With downstream fixed or variable control DPS-**-F differential pressure sensing cartridge Fixed or variable restrictor Uni-directional flow Pressure compensated flow control example With electrohydraulic proportional control downstream DPS-**-F differential pressure sensing cartridge MOS-** modulating orifice ERV- proportional pilot relief valve Uni-directional flow Pressure compensated flow control example With electrohydraulic proportional control upstream MOS-** modulating orifice PS-** pressure compensator ERV- proportional pilot relief valve Uni-directional flow 5

Flow control functions Pressure compensated priority flow control example With fixed or variable priority flow control Inlet Fixed or variable priority flow restrictor Priority flow outlet DPS-**-P differential pressure sensing cartridge Uni-directional flow Pressure compensated priority flow control example Form MOS-** modulating orifice Inlet Priority flow outlet,78mm (. ) orifice for stabilization ERV- proportional pilot relief valve DPS-**-P differential pressure sensing cartridge ypass flow to tank only Uni-directional flow Pressure compensated priority flow control example Form MOS-** modulating orifice Inlet PS-** pressure compensator, priority/bypass type Priority flow outlet ypass flow outlet ERV- proportional pilot relief valve Uni-directional flow 6

Flow control functions Load sensing priority flow control example With pressure limiting and venting Uni-directional flow Pump Variable restrictor Priority outlet, to load DPS-**-P differential pressure sensing cartridge Fixed pilot restrictor Pilot directional valve Pressure limiter pilot relief valve Load sensing priority flow control example Double acting version with pressure limiter Pump Uni-directional flow Load directional control valve Fixed or variable restrictors Load service lines DPS-**-P differential pressure sensing cartridge Fixed pilot restrictor Pilot sensing checks Pilot relief valve 7

Directional control functions Two-way, two-position, normally open examples -way, -position, normally open Switched by -way, -position pilot valve and external pilot pressure Pilot pressure source Pilot directional valve DPS-**-P differential pressure sensing cartridge -way, -position, normally open Switched by external pilot pressure and vented through -way, -position pilot valve Fixed restrictor Pilot pressure source Pilot directional valve DPS-**-P differential pressure sensing cartridge Uni-directional flow Uni-directional flow With DPS-**-V cartridge and internal pilot supply DPS-**-V differential pressure sensing cartridge Pilot directional valve With DPS-**- cartridge and internal pilot supply DPS-**- differential pressure sensing cartridge Pilot directional valve Uni-directional flow Uni-directional flow With DPS-**-S cartridge and internal pilot supply With DPS-**-T cartridge and internal pilot supply DPS-**-S differential pressure sensing cartridge Pilot directional valve DPS-**-T differential pressure sensing cartridge Pilot directional valve Uni-directional flow With DPS-**-T cartridge and internal shuttle-selected pilot supply Pilot directional valve DPS-**-T differential pressure sensing cartridge i-directional flow Pilot shuttle valve i-directional flow With DPS-**-T cartridge, external pilot supply and two-way two-position pilot directional valve Pilot source Fixed restrictor DPS-**-T differential pressure sensing cartridge Pilot directional valve i-directional flow 8

Three-way bridge circuits Form, with DPS-**-T Form, with DPS-**-P Form, with DPS-**-P Differential pressure sensing cartridges Differential pressure sensing cartridges Differential pressure sensing cartridges P P P P P P Required Flow Path Pilot Pressure to vailable from example Required Flow Path Pilot Pressure to vailable from example P P P P Yes Yes No Yes Yes No Yes Yes Yes Yes Yes Yes Pressure pplied Pressure Vented NOTE: Pilot pressure, modified by valve area ratio (if any), must exceed load pressure at valve in order to close valve. Four-way bridge circuits With DPS-**-T Differential pressure sensing cartridges With DPS-**-P Differential pressure sensing cartridges P P P P P P T P P P P5 P T P5 Required Flow Pilot Pressure to Required Flow Pilot Pressure to Path P P P P P5 Path P P P P P5 P T P T Pressure pplied Pressure Vented NOTE: Pilot pressure, modified by valve area ratio (if any), must exceed load pressure at valve in order to close valve. 9

PS- Pressure compensator Functional Symbol Description The PS- is a screw-in, pressure compensator (hydrostat) cartridge. Operation This valve, when used with either a fixed or variable orifice between port and port, maintains a constant flow. This is based on whatever pressure differential is chosen. Flow out of port, regardless of pressure, changes downstream on port. Sectional View Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)....................... bar ( psi) artridge fatigue pressure (infinite life)...................... bar ( psi) Rated flow............................................ 8 l/min ( USgpm) avity............................................... -- (See page ) Standard housing materials.......................... ustomized housings are necessary for close-coupling, the compensator and orifice. Temperature range............................. - to (- to 8 F) Fluids............................. ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration.......................................... leanliness code 8/6/ Weight cartridge only....................................., kg. (.6 lbs.) Seal kits................................................... 5658 una N 8896 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only ontrolled flow in l/min,8 cst oil @ 9 ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) ontrol p, bar (6 psi) pprox. orifice diameter inches..75.5.5..75.5.5 8 6 8 6 5 6 7 8 9 ontrolled flow USgpm 5 SUS oil @ F 5 mm

Model ode PS- 5 6 Function PS Pressure compensator spool Size Size Seals lank una N V Viton Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Spool seals lank No seal on spool S Seal on spool. For load holding applications where leakage from port to could cause cylinder drift, use of seal will increase hysteresis. 6 Pressure differential (nominal),8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) Dimensions mm (inch) 9, (.75) 5, (.) hex Torque 7-5 Nm (5- lbf ft).875 - Thd. 6, (.8) 5,8 (.6) 7, (.685)

PS-6 Pressure compensator Functional Symbol Description The PS-6 is a screw-in, pressure compensator (hydrostat) cartridge. Sectional View Operation This valve, when used with either a fixed or variable orifice between port and port, maintains a constant flow. This is based on whatever pressure differential is chosen. Flow out of port, regardless of pressure, changes downstream on port. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)...................... bar ( psi) artridge fatigue pressure (infinite life)..................... bar ( psi) Rated flow.......................................... l/min ( USgpm) avity.............................................. -6- (See page ) Standard housing materials......................... ustomized housings are necessary for close-coupling,the compensator and orifice. Temperature range............................ - to (- to 8 F) Fluids........................... ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only....................................,8 kg. (.8 lbs.) Seal kits.................................................. 5658 una N 8896 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) ontrol p, bar (6 psi) pprox. orifice diameter inches..5..5. ontrolled flow in l/min,8 cst oil @ 9 6 8 6 7 8 96 8.5..5 6 9 5 8 7 ontrolled flow USgpm 5 SUS oil @ F 8 6 mm

Model ode PS-6 5 6 Function PS Pressure compensator spool Size 6 6 Size Seals lank una N V Viton Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Spool seals lank No seal on spool S Seal on spool. For load holding applications where leakage from port to could cause cylinder drift, use of seal will increase hysteresis. 6 Pressure differential (nominal),8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) Dimensions mm (inch) 8,6 (.) 8, (.5) hex Torque 7-5 Nm (5- lbf ft). - Thd. 7, (.87) 6,95 (.6) 8,55 (.)

PS- Pressure compensator Functional Symbol Description The PS- is a screw-in, pressure compensator (hydrostat) cartridge. Operation This valve, when used with either a fixed or variable orifice between port and port, maintains a constant flow. This is based on whatever pressure differential is chosen. Flow out of port, regardless of pressure, changes downstream on port. Sectional View Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)...................... bar ( psi) artridge fatigue pressure (infinite life)..................... bar ( psi) Rated flow.......................................... 89 l/min (5 USgpm) avity.............................................. -- (See page ) Standard housing materials......................... ustomized housings are necessary for close-coupling, the compensator and orifice. Temperature range............................ - to (- to 8 F) Fluids........................... ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only....................................,88 kg. (.9 lbs.) Seal kits................................................. 88966 una N 75 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) pprox. orifice diameter ontrolled flow in l/min,8 cst oil @ 9 8 6 inches.7 6.6.5.. 8.. 5 ontrolled flow USgpm 5 SUS oil @ F mm

Model ode PS- 5 6 Function PS Pressure compensator spool Size Size Seals lank una N V Viton Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Spool seals lank No seal on spool S Seal on spool. For load holding applications where leakage from port to could cause cylinder drift, use of seal will increase hysteresis. 6 Pressure differential (nominal) 8 5,5 bar (8 psi) 6, bar (6 psi) Dimensions mm (inch), (.6) 7,6 (.87) hex Torque 9-56 Nm (95-5 lbf ft).65 - Thd. 98, (.87), (.) 6,7 (.6) 5

PS- Pressure compensator Functional Symbol Description The PS- is a screw-in, pressure compensator (hydrostat) cartridge for use as a bypass or priority flow control. Sectional View Operation This valve, when used with either a fixed or variable orifice on port, maintains a constant flow out port, regardless of pressure changes downstream of port. This is based on whatever pressure differential is chosen. ll flow in excess of the priority requirement is bypassed from port to port. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking off all flow. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)...................... bar ( psi) artridge fatigue pressure (infinite life)..................... bar ( psi) Rated flow........................................... 8 l/min ( USgpm) avity.............................................. -- (See page 5) Standard housing materials......................... ustomized housings are necessary for close-coupling, the compensator and orifice. Temperature range............................ - to (- to 8 F) Fluids........................... ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only...................................., kg. (. lbs.) Seal kits................................................. 88965 una N 88965 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) ontrol p, bar (6 psi) pprox. orifice diameter inches ontrolled priority flow, port in l/min,8 cst oil @ 9..75.5.5..75.5.5 5 5 5 5 5 6 7 8 9 ontrolled priority flow, port USgpm 5 SUS oil @ F 5 mm 6

Model ode PS- 5 Function PS Pressure compensator spool Size Size Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Pressure differential (nominal),8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) Seals lank una N V Viton Dimensions mm (in) 9, (.75) 5, (.) hex Torque 7-5 Nm (5- lbf ft).875 - Thd. 6,9 (.) 5,8 (.6) 7, (.685) 8,97 (.77) 7

PS-6 Pressure compensator Functional Symbol Description The PS-6 is a screw-in, pressure compensator (hydrostat) cartridge for use as a bypass or priority flow control. Sectional View Operation This valve, when used with either a fixed or variable orifice on port, maintains a constant flow out port, regardless of pressure changes downstream of port. This is based on whatever pressure differential is chosen. ll flow in excess of the priority requirement is bypassed from port to port. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking off all flow. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)....................... bar ( psi) artridge fatigue pressure (infinite life)...................... bar ( psi) Rated flow........................................... l/min ( USgpm) avity............................................... -6- (See page 5) Standard housing materials......................... ustomized housings are necessary for close-coupling, the compensator and orifice. Temperature range............................. - to (- to 8 F) Fluids............................ ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only.....................................,5 kg. (. lbs.) Seal kits.................................................. 88966 una N 755 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only ontrolled priority flow, port in l/min,8 cst oil @ 9 ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) ontrol p, bar (6 psi) pprox. orifice diameter inches..5..5..5..5 5 5 6 75 9 5 6 9 5 8 7 ontrolled priority flow, port USgpm 5 SUS oil @ F 8 6 mm 8

Model ode PS-6 5 Function PS Pressure compensator spool Size 6 6 Size Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Pressure differential (nominal),8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) Seals lank una N V Viton Dimensions mm (in) 8,6 (.) 8, (.5) hex Torque 8- Nm (8-9 lbf ft). - Thd.,6 (.) 5,7 (.999) 6,95 (.6) 8,55 (.) 9

PS- Pressure compensator Functional Symbol Description The PS- is a screw-in, pressure compensator (hydrostat) cartridge for use as a bypass or priority flow control. Sectional View Operation This valve, when used with either a fixed or variable orifice on port, maintains a constant priority flow (based on the pressure differential chosen) out port, regardless of pressure changes downstream on port. ll flow in excess of the priority requirement is bypassed from port to port. If the priority port is deadheaded, the valve will try to direct flow out the priority port and shut off the bypass flow, blocking off all flow. ontrol p,8 bar ( psi) ontrol p 5,5 bar (8 psi) Performance haracteristics artridge only Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)....................... bar ( psi) artridge fatigue pressure (infinite life)...................... bar ( psi) Rated flow........................................... 89 l/min (5 USgpm) avity............................................... -- (See page 5) Standard housing materials......................... ustomized housings are necessary for close-coupling, the compensator and orifice. Temperature range............................ - to (- to 8 F) Fluids............................ ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only.....................................,5 kg. (. lbs.) Seal kits.................................................. 88966 una N 755 Viton pprox. orifice diameter inches Viton is a registered trademark of E.I.DuPont ontrolled priority flow port, in l/min,8 cst oil @ 9 5 7 5 75 5.6.5.... 7 8 5 9 56 6 7 ontrolled priority flow port, USgpm 5 SUS oil @ F 5 9 6 mm

Model ode PS- 5 Function PS Pressure compensator spool Size Size Port size artridge only ustomized housings are necessary for close-coupling, compensator and orifice. 5 Pressure differential (nominal) 8 5,5 bar (8 psi) 6, bar (6 psi) Seals lank una N V Viton Dimensions mm (in), (.6) 7,6 (.87) hex Torque 9-56 Nm (95-5 lbf ft).65 - Thd. 9,7 (5.5),7 (.8), (.) 6,7 (.6)

MOS- Modulating orifice Functional Symbol Description MOS-**(V)-F MOS-**(V)-M The MOS- is a spool type, pilot operated, screw-in, modulating orifice. Operation This valve is used in series with a PS or PS pressure compensator (hydrostat), and a suitable back pressure pilot valve connected to port. Modulated flow is pressure compensated out port. Sectional View Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (all ports)...................... bar ( psi) artridge fatigue pressure (infinite life)..................... bar ( psi) ontrolled flow range (port to )................... 8 l/min ( USgpm) Pilot pressure adjustment range.....................,8 bar ( psi) avity.............................................. -- (See page 5) Standard housing materials....... The essential close coupling with a pressure compensator necessitates a customized housing to accommodate both cartridges. Temperature range............................ - to (- to 8 F) Fluids........................... ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only....................................,5 kg. (. lbs.) Seal kits................................................. 88966 una N 755 Viton Viton is a registered trademark of E.I.DuPont Performance haracteristics artridge only USgpm Pilot pressure, port bar 6 8 bar l/min ontrol p 6,5 bar ( psi) ontrol p, bar (6 psi) ontrol p 5,5 bar (8 psi) D ontrol p,8 bar ( psi) Typical flow, from port 6 8 8 6 D 5 5 75 5 5 75 psi Pilot pressure, port psi Typical flow, from port

Model ode MOS- 5 6 Function MOS Modulating orifice Size Size Seals lank una N V Viton Spool position adjustment F Fixed M Manual override 5 Port size artridge only 6 ontrolled flow range -8 l/min (- USgpm) Dimensions mm (in) M djustment F djustment 57, (.5), (.87) 5, (.) hex Torque 7-5 Nm (5- lbf ft).875 - Thd. 6,9 (.) 5,8 (.6) 7, (.686) 9, (.78)

MOS-6 Modulating orifice Functional Symbol MOS-**(V)-F MOS-**(V)-M Description The MOS-6 is a spool type, pilot operated, screw-in, modulating orifice. Operation This valve is used to modulate flow from port to port, proportional to a back pressure applied to pilot port. when used in series with a PS or PS pressure compensator (hydrostat), and a suitable back-pressure pilot valve connected to port, modulated flow is pressure compensated. Sectional View Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 (5 F) Typical application pressure (all ports)...................... bar ( psi) artridge fatigue pressure (infinite life)..................... bar ( psi) ontrolled flow range (port to )................ l/min ( 5 USgpm) Pilot pressure adjustment range.....................,8 bar ( psi) avity.............................................. -6- (See page 5) Standard housing materials....... The essential close coupling with a pressure compensator necessitates a customized housing to accommodate both cartridges. Temperature range............................ - to (- to 8 F) Fluids........................... ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only....................................,5 kg. (. lbs.) Seal kits................................................. 8896 una N 88968 Viton Performance haracteristics artridge only USgpm Viton is a registered trademark of E.I.DuPont Pilot pressure, port bar 6 8 l/min 5 D ontrol p 6,5 bar ( psi) ontrol p, bar (6 psi) ontrol p 5,5 bar (8 psi) ontrol p,8 bar ( psi) Typical flow, from port 6 8 D 5 5 75 5 5 75 Pilot pressure, port psi Typical flow, from port

Model ode MOS-6 5 6 Function MOS Modulating orifice Size 6 6 Size Seals lank una N V Viton Spool position adjustment F Fixed M Manual override 5 Port size artridge only 6 ontrolled flow range 5 - l/min (-5 USgpm) Dimensions mm (in) M djustment F djustment 57, (.5) 8, (.5) 8, (.5) hex Torque 8- Nm (8-9 lbf ft). - Thd.,5 (.99) 5,7 (.999) 6,95 (.6) 8,55 (.) 5

DPS- DIfferential pressure sensing valve Functional Symbol DPS-(V)--S. orifice Sectional View DPS-(V)--S Description The DPS- is a differential pressure sensing valve, available as either a spool or poppet type, vented or pilot operated. Operation This valve is used as a main section of a pilot controlled valve assembly. This valve has multiple uses when used with either directional control, flow control or pressure control cartridges. Refer to application examples in the front of this catalog. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (spool type)..................... 9 bar ( psi) (poppet type)...................... bar (5 psi) Rated flow............................................ 6 l/min (5 USgpm) Pilot ratio (spool type P, V, R, F)........................................ : (poppet type, S, T).......................................... : Internal leakage, poppet type.. Port to ; <5 drops/min. max. @5 bar (5 psi) Internal leakage, spool type... 8 cm /min (5 in /min.) max. @5 bar (5 psi) Temperature range............................. - to (- to 8 F) avity.............................................. --S (See page ) Standard housing materials....................................... luminum Fluids............................ ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only....................................., kg. (. lbs.) Seal kits.................................................. 88965 una N 88965 Viton Viton is a registered trademark of E.I.DuPont Pressure Drop urves artridge only /S/T models P/V models F/R models Pressure drop psi Flow in l/min (,8 cst oil @ 9 ) 5 6 5 5 5 6 8 6 Flow in USgpm (5 SUS oil @ F) 6 8 6 Pressure drop bar 6

Model ode DPS- 5 6 7 Function DPS Differential pressure sensing Size Size Seals lank una N V Viton Function Poppet, vent to open, N/ S Poppet, vent to open, N/ T Poppet, i-directional, pilot to close, : ratio, N/ P Spool, N/ V Spool, N/ R Spool, pressure reducing, N/O F Spool, flow control, N/O 5 Stroke adjustment F None (Fixed stroke) S Screw adjustment 6 Port Size O artridge only ode Port size /8 SPP 6T SE 6 6H SE 6 8H SE 8 G / SPP G /8 SPP See page 6 for housings Housing number luminum 757 566 87676 8767 87677 8767 7 Differential pressure 5,5 bar (5 psi)+,7 bar ( psi) +, bar ( psi) +,8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) + Not available with the and T poppet The operating back pressure at port should never be less than. times the spring set pressure Dimensions mm (in) S djustment, (.5) hex 8, (.89) 5, (.) hex Torque 7-5 Nm (5- lbf ft) F djustment, (.8).875 - Thd. 7, (.86) 7,5 (.687) 9, (.77) 7

DPS-6 DIfferential pressure sensing valve Functional Symbol DPS-6(V)--S. orifice Sectional View DPS-6(V)--S Description The DPS-6 is a differential pressure sensing valve, available as either a spool or poppet type, vented or pilot operated. Operation This valve is used as a main section of a pilot controlled valve assembly. This valve has multiple uses when used with either directional control, flow control or pressure control cartridges. Refer to application examples in the front of this catalog. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (spool type)..................... 9 bar ( psi) (poppet type)...................... bar (5 psi) Rated flow........................................... 89 l/min (5 USgpm) Pilot ratio (spool type P, V, R, F)........................................ : (poppet type, S, T).......................................... : Internal leakage, poppet type.. Port to ; <5 drops/min. max. @5 bar (5 psi) Internal leakage, spool type... 8 cm /min (5 in /min.) max. @5 bar (5 psi) Temperature range............................. - to (- to 8 F) avity.............................................. -6-S (See page ) Standard housing materials....................................... luminum Fluids............................ ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only.....................................,5 kg. (.78 lbs.) Seal kits.................................................. 889659 una N -6587 Viton Pressure Drop urves artridge only /S/T models P/V models F/R models Pressure drop psi Viton is a registered trademark of E.I.DuPont Flow in l/min (,8 cst oil @ 9 ) 6 8 6 8 5 6 5 8 6 5 5 Flow in USgpm (5 SUS oil @ F) Pressure drop bar 8

Model ode DPS-6 5 6 7 Function DPS Differential pressure sensing Size 6 6 Size Seals lank una N V Viton Function Poppet, vent to open, N/ S Poppet, vent to open, N/ T Poppet, i-directional, pilot to close, : ratio, N/ P Spool, N/ V Spool, N/ R Spool, pressure reducing, N/O F Spool, flow control, N/O 5 Stroke adjustment F None (Fixed stroke) S Screw adjustment 6 Port Size O artridge only ode Port size / SPP T SE H SE H SE G / SPP 6G / SPP See page 6 for housings Housing number luminum 757 566 87675 87677-6676 87676 7 Differential pressure 5,5 bar (5 psi)+, bar ( psi) +,8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) + Not available with the and T poppet The operating back pressure at port should never be less than. times the spring set pressure Dimensions mm (in) S djustment,8 (.9) hex 56, (.) 8, (.5) hex Torque 8- Nm (8-9 lbf ft) F djustment 7, (.6). - Thd. 55,6 (.8) 5,7 (.999) 8,5 (.) 9

DPS- DIfferential pressure sensing valve Functional Symbol DPS-(V)--S. orifice Sectional View DPS-(V)--S Description The DPS- is a differential pressure sensing valve, available as either a spool or poppet type, vented or pilot operated. Operation This valve is used as a main section of a pilot controlled valve assembly. This valve has multiple uses when used with either directional control, flow control or pressure control cartridges. Refer to application examples in the front of this catalog. Ratings and specifications Performance data is typical with fluid at,8 cst (5 SUS) and 9 ( F) Typical application pressure (spool type)..................... 9 bar ( psi) (poppet type)...................... bar (5 psi) Rated flow........................................... l/min (8 USgpm) Pilot ratio (spool type P, V, R, F)........................................ : (poppet type, S, T).......................................... : Internal leakage, poppet type.. Port to ; <5 drops/min. max. @5 bar (5 psi) Internal leakage, spool type... 8 cm /min (5 in /min.) max. @5 bar (5 psi) Temperature range............................. - to (- to 8 F) avity.............................................. --S (See page ) Standard housing materials....................................... luminum Fluids............................ ll general purpose hydraulic fluids such as: MIL H 566, SE, SE, etc. Filtration......................................... leanliness code 8/6/ Weight cartridge only.....................................,8 kg. (.78 lbs.) Seal kits................................................ -5 una N -969 Viton Viton is a registered trademark of E.I.DuPont Pressure Drop urves artridge only /S/T models P/V models F/R models Pressure drop psi 5 5 5 Flow in l/min (,8 cst oil @ 9 ) 8 6 8 5 6 7 8 Flow in USgpm (5 SUS oil @ F) 6 8 6 Pressure drop bar

Model ode DPS- 5 6 7 Function DPS Differential pressure sensing Size Size Seals lank una N V Viton Function Poppet, vent to open, N/ S Poppet, vent to open, N/ T Poppet, i-directional, pilot to close, : ratio, N/ P Spool, N/ V Spool, N/ R Spool, pressure reducing, N/O F Spool, flow control, N/O 5 Stroke adjustment F None (Fixed stroke) S Screw adjustment 6 Port Size O artridge only ode Port size Housing number luminum 8 SPP 757 6T SE 6 5665 H SE 8767 6H SE 6 8767 6G / SPP 8767 8G SPP 8767 See page 6 for housings 7 Differential pressure 5,5 bar (5 psi)+,7 bar ( psi) +, bar ( psi) +,8 bar ( psi) 8 5,5 bar (8 psi) 6, bar (6 psi) + Not available with the and T poppet The operating back pressure at port should never be less than. times the spring set pressure Dimensions mm (in) S djustment,8 (.9) hex 6, (.) 7,6 (.87) hex Torque 9-56 Nm (95-5 lbf ft) F djustment 9, (.).65 - Thd. 76, (.), (.) 6,7 (.6)

DPS Spool Type Functional Symbols DPS **(V) P S DPS **(V) P F DPS **(V) V S DPS **(V) V F DPS **(V) F S DPS **(V) F F DPS **(V) R S DPS **(V) R F

DPS Poppet Type Functional Symbols DPS **(V) S DPS **(V) F DPS **(V) S S DPS **(V) S F DPS **(V) T S DPS **(V) T F

Standard avity Dimensions Dimensions mm (inch) D F H 6 5,9 ±.65,75 ±.5 R,8 (.) D F H 6 5,9 ±.65,75 ±.5 R,798 (.) S G T Dia,575 R (.6) 5 6 6 X K E min. P 9 J R Dia.,575 (.6) R,575 R (.6) -way cavity L J P R Dia.,575R (.6),575R (.6) 5 6 6 X K E min. G S T Dia. 9 L -way short cavity (S) avity D E F G H J Spotface +,5 +,5 Full,5 Thread (.) ( +. ( +. ) ) S 6 6 S S,6 (.88),6 (.88),5 (.75),5 (.75) 57,66 (.7) 57,66 (.7), (.95), (.95) 5,58 (.) 5,58 (.),59 (.76),59 (.76),6 (.8),6 (.8), (.), (.) 9, (.5) 9, (.5).875.875. -. - 5,88 (.65),9 (.56), (.875) 7,6 (.687).65 -,6 (.8).65 -,6 (.8),5/,9 (./.5),5/,9 (./.5),/,68 (./.5),/,68 (./.5),5/,7 (./.7),5/,7 (./.7),59 (.85) 6,5 (.65), (.),6 (.8),5 (.75),8 (.98) 7,5 (.689) 9,8 (.75) 8,6 (.7) 8,6 (.7) 6,55 (.9) 6,55 (.9) 8, (.5) 8,8 (.55) 6,7 (.69) 6, (.8) 85,7 (.75) 6,9 (.5) K,5 (.) 5,9 (.66) 7,5 (.689) 7, (.6) 5,5 (.),8 (.),8 (.) L 7,6 (.875) 7,6 (.875) 75,9 (.968) 55,58 (.88), (.98) 77,77 (.6) avity S 6 P 8,6 (.79),9 (.56),6 (.968) R Max. Dia. 6,5 (.5),8 (.5) 5,88 (.65) S, (.),96 (.8) 5,8 (.9) T Max. Dia. 6,5 (.5),9 (.5) 5,88 (.65) X Max. Dia.,8 (.56) 5,88 (.65) 9,5 (.75) These diameters,5 mm (. inch) unless otherwise specified. These diameters,5 mm (. inch) unless otherwise specified. 6 S 6,67 (.656) 6,5 (.5) 7, (.69) 5,88 (.65) 9,5 (.75) S,96 (.8) 9,8 (.78) 5, (.) 6,5 (.5) 7, (.8) 5, (.968) 5, (.) 5, (.),6 (.88),6 (.88)

Standard avity Dimensions Dimensions mm (inch) 5 6 D..5 R F H,79 (.) G E P L S 5 R DIa. J U These diameters,5 mm (. inch) unless otherwise specified. T Dia.,6 R (.6) X 6 6 6 9,57 (.6) R V Dia. N These diameters,5 mm (. inch) unless otherwise specified. M K -Way avity avity mm (in.) Spotface,6 (.88) +,5 ( +. ), (.95) +,5 ( +. ),6 (.8) D E F G H J Full,5 Thread (.).875 5,88 (.65),5/,9 (./.5), (.875) 9,8 (.75) 8, (.5) K,5 (.) 7,5 (.689) 6,5 (.75) 5,58 (.), (.). -, (.875),/,68 (./.5), (.) 8,6 (.7) 6,7 (.69) 7, (.6) 57,66 (.7),59 (.76) 9, (.5).65 -,6 (.8),5/,7 (./.7),5 (.75) 6,55 (.9) 85,7 (.75),8 (.) avity mm (in.) 6 L M N P R S T U V,5 Max. Dia. Max. Dia. (.) 5,98 (.5) 9,9 (.59) 7, (5.) 5,9 (.66) 5,5 (.),78 (.5) 6,5 (.5),99 (.9),7 (5.56) 8,6 (.78),6 (.968),96 (.8) 6,5 (.5) 5,88 (.65) 5, (.), (.) 5,8 (.9) 7, (.8) 6,5 (.5) 5,88 (.65) 5, (.) 5, (.968) 8,76 (.8),7 (.7) 6,5 (.5) 5,88 (.65) 5, (.) X Max. Dia.,9 (.56) 9,5 (.75),6 (.88) 5

-**-S luminum Housings Housing Ports, & Part Number S SE 6 566 Light Duty /8 SPP -757 6-S / SPP -757 Light Duty SE 566 -S SPP -757 Light Duty SE 6 5665 / SPP 87677 S /8 SPP 8767 Fatigue Rated SE 6 87676 SE 8 8767 / SPP -6676 6 S / SPP 87676 Fatigue Rated SE 87675 SE 87677 / SPP 8767 S SPP 8767 Fatigue Rated SE 8767 SE 6 8767 Note: SPP porting is designated by either or G in the model code SE porting is designated by either H or T in the model code G I F F E H J D avity mm (inch) --S Light Duty -6-S Light Duty --S Light Duty --S Fatigue Rated -6-S Fatigue Rated --S Fatigue Rated D E F G H I J Mass kg (lb.) 6,5 (.5) 88,9 (.5),6 (.) 76, (.), (.5) 7, (5.),9 (.7) 7,6 (.87) 57, (.5) 8, (.5) 6, (.7) 6,5 (.5) 69,8 (.75) 88,9 (.5) 7,9 (.5) 76, (.), (.5) 7, (5.) 8, (.5) 6, (.7) 69,8 (.75) 5,8 (.) 6,5 (.5) 8,5 (.5) 9, (.), (.6),9 (.7) 5, (.),7 (.5), (.6), (.), (.6), (.6) 9,5 (.7), (.), (.),7 (.5) 7, (.68),6 (.8) 6,8 (.66), (.8),9 (.98),7 (.5) 8, (.5) 5,8 (.),5 (.), (.6) 55, (.7) 7, (.8) 8,7 (.) 8,7 (.) 7, (.8) 8,7 (.) 8,7 (.),7 (.5) 9, (.75) 9, (.75) 9, (.75) 5, (.) 5, (.), (.5),7 (.66), (.6),7 (.65), (.),6 (8.) 6

Supporting Products Roughing Tools Roughers are basically step drills which leave. per cutting diameter and.5 above all radii for the finishing reamer, with an additional.5 depth in the cavity bottom as clearance. The roughing tool is necessary to prepare the cavity for the finishing reamer, which has not been designed for the primary forming or bottom cutting. We offer two types of roughers, one for aluminum and one for steel. The aluminum rougher is manufactured with a facet point and polished flutes. The steel rougher is supplied with a standard drill point. oth types will work in either material, however, longevity of an aluminum tool will be sacrificed when used continually in steel. avity Material Model ode ssembly Number Way luminum RT 88 8895 Steel RT S 8 8895 6 luminum RT 6 89 56585 6 Steel RT 6 S 8 88957 luminum RT 8 6558 Steel RT S 86 56676 Way Short S luminum RT S 899 5658 S Steel RT S S 89 5667 6 S luminum RT 6 S 8 6558 6 S Steel RT 6 S S 85 5667 S luminum RT S 8 8895 S Steel RT S S 87 56675 Way luminum RT 87 8895 Steel RT S 87 8895 6 luminum RT 6 87 88958 6 Steel RT 6 S 875 56588 luminum RT 876 56589 Steel RT S 877 56677 Finishing Tools These finishing tools have been designed as precision reamers for finishing operations only. They are not intended for primary forming or bottom cutting operations. Vickers recommends that a finishing tool only be used in a properly roughed hole. Failure to conform to this practice will produce unsatisfactory size and finishes and possibly break the tool. avity Material Model ode ssembly Number Way luminum / Steel FT S 85 5658 6 luminum / Steel FT 6 S 88 56586 luminum / Steel FT S 88 88958 Way Short S luminum / Steel FT S S 8 56678 6 S luminum / Steel FT 6 S S 88 88956 S luminum / Steel FT S S 88 88959 Way luminum / Steel FT S 85 56588 6 luminum / Steel FT 6 S 88 56657 luminum / Steel FT S 885 8896 7

Supporting Products Finishing Form Tools Speed & Feed for luminum 66 T6 (T65) This information is recommended as a good starting point. Speeds and/or feeds may be increased or decreased depending on actual machining conditions. NOTE: Finish form tools may require / to -/ second dwell to obtain necessary finish. N MHINE TOOL RIDGEPORT / LGUN TYPE MHINES Tool Size RPM IPM Tool Size RPM IPM 8 6 55 6 6 6 6 S 6 6 S 6 S 5 S pplication Data 5 / Fluid leanliness Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity, and inclusion of air. Essential information on the correct methods for treating hydraulic fluid is included in Vickers publication 56 Vickers Guide to Systemic ontamination ontrol available from your local Vickers distributor or by contacting Vickers, Incorporated. Recommendations on filtration and the selection of products to control fluid condition are included in 56. Recommended cleanliness levels, using petroleum oil under common conditions, are based on the highest fluid pressure levels in the system and are coded in the chart below. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these cleanliness codes. See Vickers publication 56 for exact details. 8