FLUID - Panic Exit Device

Similar documents
INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Opening and closing force guidelines

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

DOUBLE SAFETY: NO PANIC, NO BACTERIA

1.0 - OPENING AND CLOSING THE DOOR

FLEXI GATE WITH SMALL PET DOOR READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF GATE. KEEP INSTRUCTIONS FOR FUTURE USE.

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Rapidmain Installation Guide

OCEAN - Wellness Line

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

CONVERTIBLE PET YARD READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF PRODUCT. KEEP INSTRUCTIONS FOR FUTURE USE.

Installation. Use. Maintenance INSTRUCTIONS. Care

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Safety System Installation Guide for ARE Wind Poles

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

F776 IM_v4_ F776 INSTRUCTIONS. Liberty Security Gate Kit. With Stay-Open Feature & Additional 9cm Extension

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Materials : Stainless steel ASTM A351 CF8M

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Roofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP

L230 LED 40 Watt Searchlight

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

Name of product: Gripper of FTV panels for horizontal façades Types: PHF (60, 80, 100, 120, 133, 150, 172,200, 240) INSTRUCTIONS FOR USE

icreasepro Creaser Operators Manual

IMPORTANT:KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. ROCK A BABY BABY ROCKER WITH TOY BAR INSTRUCTION BOOK Series LX9068

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Operation and Maintenance Instructions

USER MANUAL. All rights reserved

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

System-C Tables Handling, Operation & Maintenance Manual

Roofing Adhesive PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Insulation Adhesive for Sarnafil Roofing Systems

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

WHEATLEY Series 500 Swing Check Valve


Important Note: Tighten lock nuts so the support tubes still swing freely see figure 2. There must be 1 2 threads of bolt past end of lock nuts.

Evidence of Performance. Class 4. Class 5A. Class C5 / B5. Test Report No PR01. ift Rosenheim

CFSW. Hinges with built-in safety multiple switch

USER GUIDE ROLLING WALKERS INSTRUCTIONS FOR USE JANUARY, Maximum User Weight: 170kg (Do not exceed this weight)

2012 K9100 COMPACT Worldwide Cycling Solutions Through Creative Innovations.

Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Gauge Hatch SECTION I SECTION II

POOL FENCE STARTER KIT INSTALLATION MANUAL WARNING! ADULT ASSEMBLY ONLY DESIGNED FOR ASSEMBLY ON GRASS

by Master Halco ANCHOR GATE SYSTEMS Swing Gates Overhead Slide Gates Cantilever Slide Gates Vertical Lift Gates Fencing Without Boundaries.

Shifting Lever. RAPIDFIRE Plus 11-speed

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Drive Belt Instructions

Materials : Carbon steel ASTM A216 WCB

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Materials : Forged carbon steel A105N

CRANKSET 1 - TECHNICAL SPECIFICATIONS 2 - COMPATIBILITY CHAIN LINE SIZE 53/39-55/42-54/42 BORA ULTRA. 11s BORA ULTRA CRANKSET

SEries 29 Hydrant valves installation, operation & maintenance manual

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

Twin & Triple Control Concealed Thermostatic Shower Valve

CRANKSET 1 - TECHNICAL SPECIFICATIONS 2 - COMPATIBILITY CHAIN LINE SIZE 52/39 53/39 55/42 54/42 50/34 52/36. Ultra - torque 11s ULTRA-TORQUE

WHEATLEY Series 822/820 Swing Check Valve

WARNING! ADULT ASSEMBLY ONLY

BABY ROCKER WITH TOY BAR

Installation instructions for the Yepp Maxi Easyfit

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Translation of the original Operating Instructions for HKS rubber compensators

Forged stainless steel ASTM A182 F316

40 MINI TRAMPOLINE WITH HANDRAIL

HLS TM 7 Series* Multipoint Hardware System. Edition 2

Rhino-Rack 570, 580. Important Information

Dual Solenoid Gas Valve Installation

MyControl Bathing System Signature Series

TANDEM plus BLUMOTION 563H/563. installation instructions

GTR FlexPLI Manual. FlexPLI Preparation before Car Testing

LITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)

CERTIFICATE OF APPROVAL No CF 877 ZOO HARDWARE LIMITED

Installation, commissioning and servicing instructions

TANDEM plus BLUMOTION 563F installation instructions

REQUIREMENTS FOR NEW AND EXISTING DOMESTIC SWIMMING POOLS

PFC Lightweight Composite Push Up Mast. Operating Manual

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

FRONT DERAILLEUR - CURRENT RANGE

Trilogy Theory of Operation

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Rhino-Rack 571, 581. Important Information

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

InstallatIon and owner s InstrUCtIons

Transcription:

FUD Panic Exit Device Contents point: Rim point: Vertical point: orizontal point: Rim and vertical point: Rim and vertical point: Rim and horizontal 7 point: Rim, vertical top and horizontal bottom. mm mm mm Ø,8 x M x 0 Ø,8 x 8 Ø, x Rep A Quantity pivot axis Abis antinoise axis 7 B C D E F G 8 7 K 8

FUD Panic Exit Device nstallation for standard doors and rebated doors + mm +8 mm G Edge of frame + mm mm Templates to be aligned with the frame Add set of plates + mm + mm G +8 mm + mm + mm + mm G +8 mm + mm Edge of frame Floor + mm mini Templates to be placed 0 mm from the frame 0 mm 0 mm 0 mm G 0 mm G Floor (edge Edge of of frame) frame G 0 mm Edge of frame

FUD Panic Exit Device nstallation instructions Template layout and strike installation Use the templates included in the box mm 0 MPORTANT E F K Edge of frame 0 mm min 0 E K 00 mm F mm Mandatory radius No seal for contact between bolt and frame Floor K G mm

FUD Panic Exit Device Point Rim mm = see step 8 80 mm 0 mm 0 Abis Abis A A F or point Vertical versions, go directly to step F or point orizontal versions, go directly to step 0 0 mm 7 0 mm 8 Axial gap = mm

FUD Panic Exit Device Point Vertical 8 mm mm Cutting area to be cleared 7 8 0 7 Spring position to be checked Free rotation < Nm 8 mm 0 mm Spring position to be checked Free rotation < Nm Cutting area to be cleared Go on step

FUD Panic Exit Device Point orizontal 0 7 0 mm N + 0 mm 80 mm Top N Cutting area to be cleared Free rotation < Nm 8 M 80 mm M + 0 mm mm Cutting area to be cleared Free rotation < Nm Go on step Bottom

x x M mm Rod Cover N M FUD Panic Exit Device < Nm x nstallation and fixing instructions The following shall be the minimum information and installation guidance to accompany the panic exit device:. The producer shall specify the appropriate fixing arrangements for the door types for which the exit device is designed.. Before fitting an exit device to a door, the door should be checked to ensure correct hanging and freedom from binding. t is not recommended, for example, that exit devices befitted to hollow core doors unless specially designed by the producer for this type of doors. t is recommended to verify that the door construc tion allows the use of the device, i.e. to verify that offset hinges and engaging leaves allow both leaves to be opened simultaneously (see A.), or to verify that the gap between door leaves does not differ from that defined by the exit device producer, or to verify that the operating elements do not interfere, etc. NOTE: Panic exit devices manufactured in accordance with this European Standard will provide a high degree of safety and reasonable security provided that they are fitted to doors and door frames that are in good condition.. Before fitting a panic exit device to a fire/smoke resisting door, the fire certification should be examined to ensure the suitability of the panic exit device for that particular door assembly. See Annex B.. Care should be taken to ensure that any seals or weather stripping fitted to the complete door assembly, does not inhibit the correct operations of the panic exit device.. On double doorsets with rebated meeting stiles and where both leaves are fitted with panic exit devices, it is essential to check that either leaf will open when its panic exit device is activated and also that both leaves will open freely when both panic exit devices are operated simultaneously. The use of a carry bar to move the active leaf may be required for this application.. The bolt heads and keepers should be fitted to provide secure engagement. Care should be taken to ensure that no projection of the bolt heads, when in the withdrawn position, can prevent the door swinging freely.. Where panic exit devices are to be fitted to double doorsets with rebated meeting stiles and selfclosing devices, a door coordinator device in accordance with EN 8 (see Bibliography) should be fitted to ensure the correct closing sequence of the doors. This recommendation is particularly important with regard to fire/smoke resisting door assemblies.. No devices for securing the door in the closed position should be fitted other than that specified in this European Standard. This does not preclude the installation of selfclosing devices. 7. f a door closing device is to be used to return the door to the closed position, care should be taken not to impair the use of the doorway by the young, elderly and infirm. 8. Any keepers or protection plates provided should be fitted in order to ensure compliance with this European Standard.. A sign which reads Push bar to open or a pictogram should be provided on the inside face of the door immediately above the horizontal bar, or on the bar if it has a sufficient flat face to take the size of lettering required. The surface area of the pictogram should be not less than 8,000mm and its colours should be white on a green background. t should be designed such that the arrow points to the operating element, when installed. The pictogram given in Figure A. can be used.. Where panic exit devices are manufactured in more than one size it is important that the correct size is selected. 7. Category (standard projection) panic exit devices should be used in situations where there is restricted width for escape, or where the doors to be fitted with the panic exit devices are not able to open beyond 0. 8. Where a panic exit device is designed to be fitted to a glazed door, it is essential that the glazing is tem pered or laminated glass.. Different fixing may be necessary for fitting panic exit devices to wood, metal or frameless glass doors. For more secure fixing, male and female throughdoor bolts can be used. Maintenance instructions. Figure A. Pictogram The following shall be the minimum information to accompany the product: To ensure performance in accordance with this document, the following routine maintenance checks should be undertaken at intervals of not more than one month (or the period recommended by the producer): a) nspect and operate the panic exit device to ensure that all components are in a satisfactory working condi tion; using a force gauge, measure and record the operating forces to release the exit device. 0. Panic exit devices are not intended for use on double action (double swing) doors unless specifically de signed by the producer. b) Ensure that the keeper(s) is (are) free from obstruction.. The fixing instructions should be carefully followed during installation. These instructions and any main tenance instructions should be passed on by the installer to the user. See Annex C. d) Check that no additional locking devices have been added to the door since its original installation.. The horizontal bar should normally be installed at a height of between 00mm and,00mm from the finished floor level, when the door is in the secured position. Where it is known that the majority of the occupants of the premises will be young children, consideration should be given to reducing the height of the bar.. The horizontal bar should be installed so as to provide the maximum effective length. c) Check that the panic exit device is lubricated in accordance with the producer s instructions. e) Check periodically that all components of the system are still correct in accordance with the list of approved components originally supplied with the system. f) Check periodically that the operating element is correctly tightened and, using a force gauge, measure the operating forces to release the exit device. Check that the operating forces have not changed significantly from the operating forces recorded when originally installed. 7

FUD Panic Exit Device Maintenance after 0,000 cycles 00 mm maxi 00 mm maxi 00 kg maxi The safety features of this product are essential to its compliance with EN. No modification of any kind, other than those described in these instructions, is permitted. Warning failure to observe these fitting instructions will result in loss of warranty ASSA ABOY Australia Pty imited ABN 0 08 07 0_AAABRO000_V Disclaimer Whilst every effort has been made to ensure that the information contained in this manual is accurate at the time of publication, ASSA ABOY Australia Pty imited ( ASSA ABOY ) recommends that you consult ASSA ABOY or its agents prior to placing an order to ascertain current information on specific products, as ASSA ABOY reserves the right to make changes without notice. ASSA ABOY will not be liable for any injury, loss or damage whatsoever, arising from any errors or omissions in the information contained in the manual or arising from the use or application of the information contained herein. 0 copyright by ASSA ABOY All rights reserved ASSA ABOY Australia Pty td untingdale Road Oakleigh, Victoria, Australia 00 OCK UP (00 87) lockweb.com.au FE00 8