Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Similar documents
AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

ABB Kent-Taylor. Instruction Manual. Model 6553 Series Gas Analyzer Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Columbus Instruments

2600T Series Pressure Transmitters Calibration Frequency Determination

SITRANS P measuring instruments for pressure

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Glass tube flowmeters Series 2000

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

Best Practice Guide, Servomex 2700

LFE OEM TCD - Thermal Conductivity Detector

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure Measurement Single-range transmitters for general applications

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Mass Flow Controller (MFC) for Gases

PRODUCT CONFORMITY CERTIFICATE

FAS-W. Features. Applications. Automatic condensation hygrometer

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

Micro Motion 3098 Gas Specific Gravity Meter

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Design Features. General Description

Zirconia Oxygen Analyzer Systems

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

Transmitter CS 21 Operation Manual

ATS430 turbidity sensor Retractable insertion assembly

FLAMMABLE GAS SENSOR/TRANSMITTER

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

EASIDEW TRANSMITTER with Current Source Output

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Sensoric 4-20 ma Transmitter Board Operation Manual

2600T Series Pressure Transmitters Calibration Frequency Determination. Pressure Measurement Engineered solutions for all applications

P900. P900, Datenblatt Seite 1 DESCRIPTION

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

How to specify a product. Process Sensors and Mechanical Instruments

Pressure Measurement Single-range transmitters for general applications

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Technical Explanation

Measurement of Low GAS & Liquid Flows

Micro Motion 7812 Fiscal Gas Density Meter

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Technical Information Conducal CLY421

Service Calibration are you doing it properly?

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Precision pressure sensor Basic version Model CPT6020

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Transmitter CS 21 Operation Manual

Endura AZ40 Sensor assembly Smart electronics PCB

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Navigator 600 Silica analyzers

Endura AZ40 Sensor assembly High temperature filter assembly kit

[Instruments for vacuum measurement, checking and adjustment] 3

Technical Explanation

analytical bulk flow distance FLOW level pressure temperature industrial communication

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

High-performance submersible pressure transmitter For level measurement Model LH-20

Mass Flowmeters. Mass Flowmeters for Gases

High-performance submersible pressure transmitter For level measurement Model LH-20

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Series Environmental Chambers

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

better measurement Simply a question of

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

C-Flow Coriolis Mass Flow Meters

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Level transmitter LT 100

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

AMT-Ex Dewpoint Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

780S Ultra High Purity Series

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Measurement & Analytics Wet gas monitoring

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

SPD Pressure Sensor Families

Endura AZ40 Transmitter Main board spares kit

FTC130 Transmitter. Operating Manual

Pressure Measurement Single-range transmitters for general applications

Pneumatic high-pressure controller Model CPC7000

High-performance submersible pressure transmitter For level measurement Model LH-10

Transcription:

Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC T4.Tamb 20 to 55 C ( 4 to 131 F) Robust no moving parts Suitable for corrosive gases No routine span checks Accurate levelling unnecessary

General Introduction The Katharometer is a device which provides a change in an electrical output signal in response to a change in the thermal conductivity of a gas passing through it. If a gas mixture of known constituents is passed through a Katharometer by means of a suitable gas sampling system, then any changes in output signal are related to changes in the composition of the gas stream. The Katharometer is non-specific but, for binary, and many complex mixtures, details of the concentration of one of the gases in a mixture can be provided. All gases and vapours have a characteristic thermal conductivity which can differ considerably from one gas to another. For example, the thermal conductivity of air is approximately three times that of sulphur dioxide and only one-seventh that of hydrogen. The analysis equipment is simple, robust and correspondingly easy to install and maintain. It is accurate and reliable in service and, since sampling is continuous and automatic, is ideal for process monitoring and control. The Principle If a current is passed through an electrical conductor surrounded by gas in a chamber, the temperature of that conductor rises until a point of thermal equilibrium is reached. At this point, the electrical energy supplied to the conductor is equal to the thermal energy lost to its surroundings. Provided that radiation, convection and end-conduction losses are minimized, the temperature of the conductor can be assumed to depend upon the heat loss by conduction through the gas. Since the change of electrical resistance of the conductor is a function of its change in temperature, measurement of the former determines the latter. The Katharometer comprises matched platinum-wire filaments, finely coated with glass, and forming a Wheatstone bridge network. The filaments are enclosed in separate cells in a comparatively massive block. Thermal conductivity differences between the reference gas and the measured gas cause imbalance of the bridge and hence an output (EmV) which may be calibrated directly in terms of the gas being measured. The Choice of Katharometer There are many circumstances in industry where it is necessary to monitor the variations in a gas stream for process control, safety monitoring or economic operation. Where the Katharometer is capable of carrying out the required measurements it offers several advantages over other systems. These are: a) Designed to operate continuously no moving parts b) Under favourable conditions has a working life of many years c) Can be adapted to operate in hazardous areas d) Is highly stable e) Is compact and does not interfere with the process being monitored. Katharometers are available in standard or corrosion-resistant forms, some of these being available thermally lagged for indoor applications or for use with flammable gases. Both the standard and corrosion-resistant versions may be thermostatically controlled where ambient conditions are usually variable or where the highest level of accuracy and stability are required. In theory the Katharometer is suitable only for use with binary gas mixtures. The Katharometer incorporates sealed reference cells and this method is called The Direct Measurement Technique see Fig. 1. Exposed sample cells Sealed reference cells Fig. 1 Direct Measurement Technique Dry Gases Ω Ω 2

However, the use of Katharometers may be considerably extended by: a) Comparing the thermal conductivity of a stream before and after a reaction to promote the effect of variations in the measured variable. This is the Differential Measurement Technique see Fig. 2. b) Exploiting common factors between two or more sample constituents, for example, air is comprised principally of nitrogen and oxygen. Reference to Fig. 3 shows a similarity in thermal conductivity that enables air to be treated as one gas c) Treating the gas prior to measurement, for example, absorbing out an interfering constituent Equivalent delay chamber Reaction chamber Fig. 2 Differential Measurement Technique CHCl 3 Cl 2 SO 2 C 6 H 6 C 3 H 6 0 C 6 H 14 C 5 H 12 H 2 S CO 2 N 2 O A C 2 H 6 NH 3 NO CO N 2 O 2 CH 4 Ne He H 2 Katharometer Types Available All Katharometers in this series are housed in a steel case of common size and presentation. The Katharometer is usually supplied mounted on a steel panel, also containing the associated sample control accessories, for example, flow control valve and flow gauge, drying chambers and sample aspirators; of which there is a choice of types available. The following Katharometers are within the standard range: For Non-Corrosive Gases 6517-000 Thermally-lagged direct-acting type 6539-960K As 6517-000 but with protective diodes for flammable gases CENELEC Certificate EExia IIC T4 (Zone 0) 6548-001 As 6539-960K but pressure tested to 10 bar 6518-000 Thermostatically controlled direct-acting type 6520-000 Thermostatically controlled differential type 6521-000 Thermally lagged differential type 6539-970K As 6521-000 but with protective diodes for flammable gases CENELEC Certificate EExia IIC T4 (Zone 0) For Corrosive Gases All parts in contact with the gas are either glass, PVC or Viton 6522-000 Thermally lagged direct-acting type 6523-000 Thermally lagged differential type 6524-000 Thermostatically controlled direct-acting type 0 100 200 300 400 500 600 700 Fig. 3 Thermal conductivities relative to air at 0 C where air is 100 3

Installation The Katharometer is not a complete gas analyzer but is the detector within a gas analysis system. The minimum additional requirements are for a constant current power supply unit for the bridge circuit and an indicator. These items can be mounted remotely from the Katharometer and must be mounted in a safe area. Using suitable accessories the Katharometer can then be mounted in a hazardous area. Fig. 4 shows the simplest form of installation which is suitable for a direct measurement where a clean and dry sample is available at the correct pressure and flow. Transmitter/ Indicator Gas Inlet mv Signal to Indicator 6517 Katharometer Fig. 4 Simple Katharometer System Single Phase Mains Supply 4234600/601 Power Supply Unit 350mA Current Supply Gas Outlet Fig. 5 shows a more complex installation in which the Katharometer is mounted on a panel from the 6540 Series and includes a flow control facility and a small drying chamber. A local indicator or remote recorder is also coupled to the Katharometer output. Amplifiers, or digital indicators, are available to convert the millivolt signal from the Katharometer to a current signal, e.g. 0 to 10mA, 0 to 20mA, 4 to 20mA. The output signal is preset to the user s choice. Alarms are integral with the digital displays. Monitoring Flammable Gases When it is required to monitor explosive mixtures such as hydrogen or methane in air and also in some potentially dangerous areas, precautions are necessary to ensure that the gas analyzer does not cause an explosion. The main difference between the standard and the certified apparatus is the use of a certified I.S. power supply unit for the Katharometer bridge circuit and the fitting of the protective diodes within the Katharometer. Additionally the output signal from the Katharometer must be connected via shunt diode safety barriers to any mains-operated display equipment or amplifier which must be mounted in a safe area. Equipment of the above type conforms with the requirements of CENELEC Standard EExia IIC (Zone 0) T4. Tamb 20 C/+55 C, Groups IIA, IIB and for hydrogen in Group IIC. It must be noted that for the safety certification to be effective the equipment must be installed exactly in accordance with the instructions supplied and that: a) It is not possible to use a Katharometer to measure some of the gases/vapors covered by Group IIC of the BASEEFA standard and b) The certificate refers to the mixture of these gases with air and not oxygen, although certain oxygen ranges are permitted. Fig. 4 shows the layout of a simple system conforming to the relevant BASEEFA requirements. Shunt Diode Safety Barriers The action of the barrier unit is to allow a signal to be passed with negligible distortion up to the avalanche voltage of the zener diodes. Above this voltage the diodes conduct and hold down the potential across the terminals to a safe level. Further installation details are available from BASEEFA standards. Indicator or Recorder Power Supply Unit Mains Input Gas Inlet Control Valve Katharometer Gas Outlet Dryer Flow Gauge Fig. 5 Typical Katharometer Installation 4

Sampling Accessories A full range of filters, aspirators, flow control accessories etc. are available for use with this Series of Katharometers. They are usually mounted on a panel, together with the Katharometer, with all interconnecting pipework. Careful selection of the sampling accessories enables a wide variety of industrial gases to be presented to the Katharometer under optimum conditions for stable readings and long instrument life. Indicators, Recorders and Controllers The Katharometer supplies an output signal that is most suitable for a potentiometric receiver; the ABB range of indicators and recorders being particularly recommended. The output signal may also be made suitable for galvanometer indicators provided that they are of a suitable sensitivity and resistance. Power Supply Unit Type 4234 The accuracy of a Katharometer system is dependent upon the accuracy and stability of the current supplied to the Katharometer bridge. An error of 1% in the bridge current can cause an error of up to 3% in the final reading and for this reason a specially developed constant current unit is available. Specification Katharometer 6517 Series Approximate volume 5ml (0.169 fl ozs.) (differential Katharometers 10ml [0.338 fl ozs.]) Optimum sample flow rate 50 to 200ml/min. (1.691 to 0.6.763 fl ozs.) Bridge current 350mA standard Some special applications require a different current Thermostat temperature (when fitted) 47 C ±0.5 (116.6 F ±1 F) (55 C [131 F] for some applications) Accuracy Better than 1% FSD at time of calibration Output signal 0 to 1mV to 0 to 50mV depending on range and requirements Preferred standard outputs 0 to 5mV or 0 to 10mV Pipe connections 4mm compression fitting, in 1 /8 in. BSP female mount Series 4234 Power Supply 5

Specification Power Supplies Series 4234-600 and 4234-601 Supplies 1 or 2 Katharometers with a preset current (normally 350mA) Maximum load 21Ω, including connecting cable Supply voltages Series 4234-601 Series 4234-600 Ambient temperature range 20 to 55 C ( 4 to 131 F) 115V 50/60Hz 230V 50/60Hz Stability Within ±0.7% of initial setting over one month Dimensions 160mm high x 170mm width x 111mm deep (6.3 in. high x 6.7 in. width x 4.4 in. deep) Cable entries Three separate glands suitable for cables 6.5 to 10.5mm (0.256 to 0.413 in.) Weight 2.12kg (4.7 lb) Series 4234-500 and 4234-501 For intrinsically safe applications. Must be installed in a safe atmosphere and are for use with a Katharometer measuring a potentially inflammable gas in air. Supplies one Katharometer only. Maximum load Katharometer 13Ω max. Cable 2Ω max. Supply voltage Series 4234-501 Series 4234-500 Ambient temperature range 20 to 55 C ( 4 to 131 F) 115V 50/60Hz 230V 50/60Hz Stability Within ±0.7% of initial setting over one month Dimensions 160mm high x 170mm width x 111mm deep (6.3 in. high x 6.7 in. width x 4.4 in. deep) Weight 2.12kg (4.7 lb) Overall Dimensions Dimensions in mm (in.) 233 (9.17) 178 (7) 109 (4.29) 82 (3.23) 178 (7) Gas Inlet Gas Outlet 157 (6.18) 104 (4.09) 4 Holes 7 (0.275)ø Note. Size and detailed location of pipe unions vary with Katharometer type. Data shown is for type 6517. Katharometer 6

Electrical Connections Electrical connections are made to the 12-way screw terminal block inside the Katharometer unit via the 20mm cable gland on the right side of the unit casing. The gland is suitable for cables 6.5mm to 10.5mm (0.256 to 0.413 in.) diameter. Safe Area Hazardous Area 4V Safety Barriers L + 1 2 Safe Area N E Power Supply Unit 4234-500 4234-501 Katharometer 6539-960K Indicator 4 3 3 4 2 1 +ve 3 4 2 1 +ve Cable used as specified in latest BASEEFA standard Typical wiring schematic Katharometer Terminal Connections Terminal Connections 1. Power supply (+ve)(350ma) 2. +ve Bridge Output 3. ve (Range 1) 4. Power Supply ( ve)(350ma) 5. +ve Bridge Output 6. ve (Range 2 if supplied) 7. +ve Power supply to Temperature Control 8. ve Circuit (Models 6518 & 6520 only) 9. 10. Provision for external zero control (1kΩ variable resistor) 11. Allocated for special purposes as required 12. Allocated for special purposes as required Ordering Information Due to the extremely wide and varied range of Katharometers that can be supplied a questionnaire is available on application to assist in fulfilling the requirements for all the process details needed before a quotation can be provided. 7

Contact us ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 826 661 Fax: +44 1453 829 671 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2010 ABB All rights reserved 3KXA834701R1001 12.2010 www.abb.com