CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Similar documents
HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

GMC-I Service GmbH Calibration Center

Maximum precision for quantifiable success.

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

OMNIPORT 30. Multifunctional Hand-Held. Data-Logging & Data-Management. Features

Gas mixtures. Individual solutions specifically for your application

EN ISO/IEC Technical Requirements

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

Calibration certificates

Speciality Gases Practice 4. Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel.

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Recommended Practices for Calibration Laboratories

Sartorius CCL kg Prototype Mass Comparator

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

Calibration equipment

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Traceable calibration of automatic weighing instruments in dynamic operation

FPG8601 Force Balanced Piston Gauge

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Pressure Metrology in Mexico

Pneumatic high-pressure controller Model CPC7000

MET-101 Introduction to Metrology

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Calibration equipment

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

2014 Programme of Training Courses in Measurement & Calibration

CALIBRATION CERTIFICATE # 500

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Technical Information Conducal CLY421

How we calibrate the Wave Height and Period Measurements from the Gravitational Acceleration Wave Buoys in RMIC/AP

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

Certificate of Accreditation

Hand-held pressure calibrator with integrated pump Model CPH6600

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

PERFORMANCE TEST INSTRUCTIONS FOR BIOHIT PROLINE PIPETTORS

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

Hydraulic pressure balance Model CPB5800

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

Pressure is our Business

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Field verification of on-line HC dew point measurements

Flow metering in gases Introduction to COMBIMASS family

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Mass Flowmeters. Mass Flowmeters for Gases

INTERNATIONAL STANDARD

Pneumatic high-pressure controller Model CPC7000

CALIBRATION AND TRACEABILITY: ITS IMPORTANCE IN THE GAS INDUSTRY

John Wright NIST Fluid Metrology Group February 21, 2013

deltaflowc deltaflowc Venturi or Probe

Heading 10 NEW. Calibration Technology Pressure. ARMATURENBAU GmbH MANOTHERM Beierfeld GmbH

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Metering Code Gas TSO, measurement by connected party Effective from to the present

FLOW CALIBRATION RIG Mobile Calibration of In-line Flow Meters

Application Note AN-107

ali-q TM Gravimetric Verification Procedure

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

Mass Flow Meter (MFM) for Gases

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

VITLAB micropipette. Standard Operating Procedure (SOP)

How to specify a product. Process Sensors and Mechanical Instruments

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Research and Development. Money in the Pipeline

tradition. knowledge. responsibility. CALIBRATION OF ELECTRICAL MEASUREMENT EQUIPMENT CALIBRATION LABORATORY

Any use of this material except in accordance with a written agreement with Western Power is prohibited.

Precision pressure sensor Basic version Model CPT6020

CHAPTER 3 RESULTS AND DISCUSSION

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Transmitter CS 21 Operation Manual

High-speed pressure sensor Model CPT6140

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Transcription:

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE (+34) 968 162 005 www.sensovant.com comercial@sensovant.com

www.epluse.com CALIBRATION AT THE HIGHEST LEVEL The National Metrological Institute (NMI) or its Designated Institutes (DI) maintain the highest national measurement standards and ensure that the measurements correspond to the international system of units SI. NMIs and DIs participate in international comparative measurements with other NMIs and cooperate in technical committees to ensure that they are the top reference for measurement variables. The measurement uncertainties of NMIs or DIs do not (or hardly) exceed those of accredited top calibration laboratories but can also be provided for special calibration tasks as part of the internationally agreed calibration options (CMC data) published in the BIPM (Bureau International des Poids et Mesures). NMIs BEV / Designated labs (Nationale standards) CALIBRATION AUTHORITES CALIBRATION BODIES OTHER AUTHORITIES 2

E+E YOUR PARTNER FOR CALIBRATION Measuring control, calibration and traceability is a central topic of most quality assurance systems. During the calibration in measurement technology calibrators detect and document reliably and reproducibly how large the deviation of a measurement device to a normal is. The reliable calibration of your measuring instruments either in our OEKD accredited calibration laboratory or directly at your site. Special calibration of humidity and air velocity meters can be covered in our designated NMI calibration. Based on the agreements between the members of EA (European Cooperation for issued by E+E conform to worldwide recognized standards. E+E Elektronik is commissioned to provide the National standards for humidity and air velocity in Austria as designated laboratory (NMI) by the Federal Ministry. DESIGNATED NMI LABORATORY interest to accredited calibration authorities. For the highest measurement authority in a country there is the opportunity to build expertise about measurements can be performed beyond the OEKD accreditation. ACCREDITED OEKD LABORATORY The calibration laboratory of E+E Elektronik is accredited according to DIN EN ISO/IEC 17025, with identification number 0608, by Akkreditierung Austria / Federal Ministry of Science, Research and Economy. OEKD certificates document the traceability of measurements to national standards. The Akkreditierung Austria is responsible for the accreditation and supervision. Each OEKD certificate must be approved by an authorised signatory. OEKD certificates are issued for measuring instruments, when measurements need to be traceable (e.g. works standards). 3

HUMIDITY Measurement under extreme climatic conditions is one of E+E Elektronik s specialities. The E+E OEKD Laboratory offers relative humidity calibrations in the temperature range from -70 to 200 C. A complex two-pressure/two-temperature generator combined with a stable/homogenous temperature cabinet provides highest accuracy for relative humidity. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range 1) Measurement uncertainty NMI Lab Special calibration of humidity measurement equipment in the designated lab BEV/E+E OEKD Lab Hygrometer for the measurement of humidity OEKD Lab Humidity generator (z.b. Humor 20) OEKD on-site Hygrometer for the measurement of humidity Gas flow max. 5 l/min Air pressure max. 10 bar Temperature range -40...180 C 1) 0...98 % RH; -40...<0 C 0...98 % RH; 0...200 C 1) On request, certificates are possible in the extended measuring range -70...200 C (-94...392 F), in the Designated laboratory at the highest accuracy. Other humidity measurement parameters on request (dv, r, wv, etc.) 0.2 % RH+0.6 % of m.v. 0.1 % RH+0.4 % of m.v. Temperature range (25 ±3) C 10...95 % RH (0.15+0.5 % of m.v.) % RH Comparative measuring with humidity generator at ambient temperature (25 ±10) C 10...95 % RH (0.5+0.6 % of m.v.) % RH SCOPE OF ACCREDITATION [%RH] ACCREDITED ON-SITE SERVICE Take the opportunity of on-site calibration! Range I is the E+E standard measurement range: (23 ±3) C, 15...95 % RH and 0 % RH [ C] Ranges II, III, IV and V define extended calibration ranges with different delivery times and prices. 4

DEW POINT The E+E dew point calibration bench impresses with a very low measurement uncertainty and a calibration range from -90 C frost point (Tf) to 95 C dew point (Td). Standard calibrations are carried out in nitrogen, other gases such as methane upon request. The E+E calibration service also offers special calibrations of dew point meters and dew point mirrors in the designated lab. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range 1) Measurement uncertainty OEKD Lab Dew point hygrometer (Dew point mirror) Dew point transmitter (Dew point hygrometer) OEKD Lab Dew point transmitter (Dew point hygrometer) OEKD onsite Dew point generator Gas flow max. 5 l/min Air pressure max. 10 bar for Td -64.6...95 C (950 ±150) mbar for Td <-64.6 C -75...<-55 C -55...<-22.5 C -22.5...70 C >70...95 C Pressure range 1...100 bar Air or nitrogen 2) -90...<-80 C -80...<-55 C -55...<-25 C -25...20 C Gas flow min. 1 l/min Air pressure (950 ±150) mbar -75...<-55 C -55...<-22.5 C -22.5...70 C >70...95 C 1) According to the BIPM Service category 3.1, dew point is used as denomination for the measurand. For values <0 C the value refers to frost point. Calibration for values <0 C can also be carried out for the calculated dew point temperature. 2) Other gases, such as methane upon request 0.05-(55+Tf)*0.01 K 0.05 K 0.035 K 0.045 K 0.2-(80+Tf)*0.02 K 0.05-(55+Tf)*0.006 K 0.05 K 0.035 K 0.07-(55+Tf)*0.01 K 0.07 K 0.05 K 0.06 K Lexicon What does ACCREDITED CALIBRATION mean? e.g.: DAkkS (D), Akkreditierung Austria (ÖKD, A), SCS (CH), UKAS (GB), NVLAP (US) and thus its international comparability. Particularly important is the statement of measurement uncertainties, the determination of which includes the measurement process. Independent assessors must also examine the suitability of the process or measurement process in order to assure traceability. According to international agreements (ILAC), only inspection laboratories accredited according to DIN EN ISO/IEC 17025 (calibration laboratories) are permitted to carry out traceable calibrations and thus guarantee complete international comparability of the calibration results. A device that was merely compared with a traceable measuring device is not itself traceable since the measurement process was not performed in accordance with an accredited procedure. 5

AIR VELOCITY Two wind tunnels are available to calibrate the air speed: One free-stream wind tunnel up to 40 m/s with integrated temperature control up to 80 C and one special wind tunnel for the low-flow range between 0.04 and 2 m/s. In combination with a laser Doppler anemometer, high reproducibility of results can be achieved. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range Measurement uncertainty NMI Lab Special calibration of air velocity measuring instruments in the designated lab BEV/E+E OEKD Lab Measuring instruments for recording air velocity OEKD Lab Measuring instruments for recording air velocity (23 ±3) C ambient air pressure 5...80 C ambient air pressure 0.04...2 m/s 0.004 m/s + 0.47 % of m.v. 0.3...40 m/s 0.004 m/s + 0.47 % of m.v. Lexicon What does TRACEABILITY mean? The concept traceability describes a process in which the measured quantities displayed by a measuring device can be compared in one or several steps with a national standard for the indicated measurement quantities. These steps must form an unbroken chain of calibrations. In each case, one measuring device is compared with one standard whose metrological characteristics are determined by a comparison with a higher-level standard. Departments which perform the comparisons within this chain have to document their appropriate competencies, e.g. through an accreditation in accordance with DIN EN ISO/IEC 17025. Traceable calibrations can only be performed by accredited calibration laboratories. 6

MASS FLOW The E+E OEKD Laboratory for air flow is unique in Europe and offers mass flow and volumetric flow calibrations for standard conditions in the range from 0.6 to 2300 m³/h. To allow calibration as close as possible to the real application, the operating pressure in the system can be set between 1 and 10 bar. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Lab Mass flow sensor/ Flow transmitter 0.1...1 MPa (1...10 bar) at (23 ±3) C Flow rate at standard conditions (0 C / 1013 mbar) 0.6...2300 m 3 /h 0.003 m 3 /h + 0.9 % of m.v. Lexicon What does MEASUREMENT UNCERTAINTY mean? The measurement uncertainty is a feature of an accredited procedure. It describes to what extent a measurement can be traced to national standards and ultimately to International System of Units (SI units). Usually, an extended measuring uncertainty is specified, which is calculated from the standard uncertainty multiplied with the extension factor k=2. Each measuring value is associated with a (measurement) uncertainty. In the calibration hierarchy, testing equipment on a higher level has a lower measuring uncertainty that that on a lower level. Accreditation in line with DIN EN ISO/IEC 17025 requires that measurement uncertainties are calculated according to EA-4/02 Guide to Expression of the Uncertainty of Measurement in Calibration, GUM. 7

TEMPERATURE Depending on the requirements, calibration in air and calibration in the block calibrator are offered. With air as the medium, temperature calibration is limited to the range between -40 to 180 C. For simple calibration in the block calibrator, the laboratory is certified for the temperature range -45 to 425 C. The essential difference between air and block calibration is to be seen in how the heat generated in the test piece by the measurement medium is taken into account. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Lab Thermometer for air temperature comparison measurement in temperaturecontrolled measuring chamber -70...200 C 0.05 K OEKD Lab / on-site Contact thermometer (Immersion- and cut-in probe) comparison measurement in dry block calibrator -45...425 C <23 C: 0.5* t-23 + 28 mk 23 C: 0.22* t-23 + 28 mk ACCREDITED ON-SITE SERVICE Take the opportunity of on-site calibration! 8

PRESSURE Pressure meters for both absolute and relative pressure and differential pressure can be calibrated in the calibration lab at E+E Elektronik. A high-precision pressure calibrator is available for calibrating absolute and relative high pressure meters. For the calibration of differential pressure sensors, the differential pressure is generated via a constricted gas flow. The differential pressure is calibrated with the ambient pressure as the static pressure. All calibrations are carried out using nitrogen as the pressure medium. Accreditation scope of the E+E Calibration Laboratory Calibration Calibration object Measuring condition Measuring range Measurement uncertainty OEKD Lab Absolute pressure sensor (23 ±3) C 0.1...1 bar 1...21 bar 21...101 bar OEKD Lab Relative pressure sensor (23 ±3) C -0.9...0 bar 0...<20 bar 20...100 bar OEKD Lab Differential pressure sensor (23 ±3) C 0...0.3 bar 0.3...9 bar 0.00028 bar 0.01 % of m.v. + 0.00018 bar 0.011 % of m.v. + 0.00006 bar 0.00028 bar 0.01 % of m.v. + 0.00028 bar 0.011 % of m.v. + 0.00016 bar 0.19 % of m.v. + 0.00005 bar 0.16 % of m.v. + 0.00006 bar Lexicon What does FACTORY CALIBRATION mean? Factory calibrations are not legally valid documents for traceability verification; however, they do contain the manufacturer s confirmation that the products have been manufactured and inspected in compliance with the applicable regulations using the appropriate materials and internal monitoring procedures. These calibration certificates are issued on the basis of standards like DIN EN 10204, for example, and represent documented final inspections of the producer. Such certificates can also be offered at low cost for products, or are included as standard. 9

CO 2 The calibration is performed as comparative measurement with a constant CO 2 reference concentration. The CO 2 reference concentration is generated by a special gas mixing pump according to DIN 51898-1 and is freely selectable. Due to the and by this the CO 2 reference concentration can be traced back to length, which is a fundamental physical quantity of the International System of Units (SI). Therefore, the E+E CO 2 reference generator is a primary standard. Calibration range Calibration conditions Calibration range* Calibration uncertainty* (23 ± 5) C ambient pressure 5...1,150 ppm (6 + 1.07 % of m. v.) ppm 500...300,000 ppm (6 + 0.38 % of m. v.) ppm j in μl/l. Lexicon What does ISO CALIBRATION mean? ISO calibrations are comparative measurements of external test candidates with in-house reference equipment (factory-level standards) as a service. The reference equipment utilized is traceable to national standards. The comparative measurement is carried out in accordance with internal procedures which meet the requirements in accordance with ISO 9001 or ISO TS16949 as well. The comparative measurement merely provides information about the calibration condition of the equipment with the use of high-quality measuring equipment. ISO calibrations purchased as additional external services are not traceable (there is no accredited process!). The measurement results are therefore not internationally comparable. 10

CALIBRATION PROCEDURE Upon receipt of the measuring equipment an initial calibration is carried out in accordance with customer s specifications. The measured values are documented on a certificate. If requested, the measuring results will be compared with the specified tolerances of the measuring equipment as part of the initial calibration. If the recorded values for the measuring equipment fall outside the permissible tolerances, the customer may use the information to validate the results of previous quality tests and eventually initiate appropriate corrective action. At the request of the customer, a quotation will be issued for the cost of repair, respectively the adjustments. If E+E is not able to repair the equipment, it will be either returned to the customer or shipped directly to the manufacturer. Once the equipment has been repaired and adjusted, the measuring values will be documented during the second calibration routine. Separate certificates are issued for the first and second calibration confirming the measured values as received and as delivered. Progression of a calibration Delivery to E+E First calibration according to specifications Values within tolerances NO Information to customer, incl. quotation Customer places order for repair YES Repair / Justage YES NO Second calibration according to specifications Certificate for first calibration Certificate for first calibration Certification for 1 st + 2 nd calibration Delivery + invoice for calibration services Delivery + invoice for calibration services Delivery + invoice for Repair and calibration services ON-SITE CALIBRATION On-site calibration may be required for certain process and quality-relevant measuring points. For this purpose, E+E offers a manufacturer-independent calibration service for the physical quantities humidity and temperature. The on-site service covers the calibration of stationary and portable instrumentation as well as climate chambers with specific customer requirements. Advantages + Traceability to national and international standards + Calibration of on-site equipment and measuring instruments possible + Independent supervision of test equipment by an accredited company + No malfunction of test equipment + Quick turn-around times + No transportation risks 11

E+E Elektronik Headquarters E+E ELEKTRONIK - YOUR PARTNER IN SENSOR TECHNOLOGY. E+E Elektronik GmbH, with headquarters in Engerwitzdorf, Austria, has been established in 1979 and is part of Dr. Johannes Heidenhain GmbH group. Diverse. E+E Elektronik is a leading manufacturer of sensors and transmitters for a multitude of physical quantities and applications. Data loggers, hand-held meters as well as calibration systems and services round up the product portfolio. Reliable. Best quality made in Austria, high accuracy and outstanding long-term stability, together with advanced understanding of customer specific requirements are the main competitive advantages of E+E Elektronik. Versatile. Measuring devices from E+E Elektronik are used all over the world in most diverse industries such as building automation, meteorology, agriculture, food, pharmaceutical, process control or automotive. HUMIDITY TEMPERATURE DEW POINT MOISTURE IN OIL MASS FLOW CO 2 AIR VELOCITY E+E CALIBRATION SERVICES www.eplusecal.com Flexible. With own clean room sensor manufacturing, in-house design of state of the art electronics and highest competence in calibration, E+E Elektronik is the ideal partner for OEM customers. Certified. The E+E quality assurance system is certified according to ISO 9001 and ISO/TS 16949. The company also complies with the environmental standard ISO 14001. The in-house calibration laboratories are accredited according to DIN EN ISO/IEC 17025. Global. E+E Elektronik sales subsidiaries are located in China, Germany, France, Italy, Korea and the USA. Additionally, E+E maintains a worldwide network of distribution partners. www.epluse.com Subscribe to the E+E newsletter to be regularly informed about new products. Version 2.1 // Modification rights reserved // Art. Nr. 485064 (+34) 968 162 005 www.sensovant.com comercial@sensovant.com