Similar documents
The magic of active NCPAP

Inspire rpap REVOLUTION FROM THE FIRST BREATH

CATALOGUE. Adult and Infant Respiratory Care Catalogue

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Giving neonates a future

AUTOVENT 4000 VENTILATOR

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Supporting you in saving lives!

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

INTELLiVENT -ASV. The world s first Ventilation Autopilot

Minimum size for maximum performance

fabian Therapy evolution Our 2-in-1 device

fabian HFO: Modular, Powerful, Versatile.

HAMILTON-C3. The compact high-end ventilator

Hospital and Transport for Controlled Breathing

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Emergency Transport and Ventilation

(Delivery System) Pocket Guide. Series 3 software

HAMILTON-T1 Intelligent transport ventilation for armed forces

Intelligent Ventilation solution from ICU to MRI

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

Oxylog 3000 plus Emergency & Transport Ventilation

Corporate Overview and Product Summary

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

(Delivery System) Pocket Guide Series 3 software

Unit 15 Manual Resuscitators

Hallowell EMC Anesthesia WorkStation Operating Manual

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE.

Mechanical ven3la3on. Neonatal Mechanical Ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on. Mechanical ven3la3on 8/25/11. What we need to do"

The aim of this guideline is to describe the indications and procedure for using high flow nasal prong oxygen

Monnal T60. Touch and Breathe.

HAMILTON-C1 neo. Technical specifications

ASV. Adaptive Support Ventilation

fabian HFO Our 4-in-1 device

Technical Data and Specifications

HIGH FREQUENCY JET VENTILATION (HFJV): EQUIPMENT PREPRATION

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

SLE5000 Infant Ventilator with HFO

HAMILTON-G5. The modular high-end ventilation solution

Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Intelligent Ventilation. Hamilton Medical. Intelligent Ventilation since 1983

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

INTENSIVE CARE VENTILATORS

Home Oxygen Products. > Innovation > Quality > Safety

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Oxylog VE300 Emergency & Transport Ventilation

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Health Professional Info

Operation and Maintenance of the EPV200 Portable Ventilator

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

HAMILTON-MR1. Technical specifications HAMILTON-MR1

DATA SHEET. VENTILATION SERVO-s

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

MACS Mask CPAP System

C O R P O R AT E B R O C H U R E

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

QUICK REFERENCE GUIDE

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

Flow meter. bellow vaporizer. APL valve. Scavenging system

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

How Ventilators Work. Chapter 3

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

IEC C LASSIFICATIONS:

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

Mechanical Ventilation

Airox Supportair Ventilator

Aespire 7100 Essential performance Compact design

OXYGEN THERAPY. (Non-invasive O2 therapy in patient >8yrs)

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

2) an acute situation in which hypoxemia is suspected.

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

Safe and Intuitive Neonatal Ventilation

System Flow Chart. ventilation patient connection

Hamilton accessories CONTENT

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

Lung recruitment maneuvers

pneuton Transport Ventilator

Selecting the Ventilator and the Mode. Chapter 6

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

PHTY 300 Wk 1 Lectures

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

V8800 Ventilator System. Your healthcare, we care.

Infant Warmers Quality for life

Clinical Skills. Administering Oxygen

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

Introduction. Respiration. Chapter 10. Objectives. Objectives. The Respiratory System

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

RESPIRATORY CARE POLICY AND PROCEDURE MANUAL. a) Persistent hypoxemia despite improved ventilatory pattern and elevated Fl02

Transcription:

Advanced nasal CPAP system

www.hamilton-medical.com/arabella Noninvasive, low-cost, effective and safe Neonatal nasal CPAP therapy Nasal CPAP therapy aims to support neonates, especially pre-term and low-birthweight newborns, who can breathe spontaneously but inadequately. The therapy is noninvasive, low cost, clinically effective and safe. When applied properly and promptly, nasal CPAP can minimize both the need for intubation and mechanical ventilation and promote early extubation, as well as decrease incidence of chronic lung disease. Nasal CPAP, developed in the 1930s and used widely for nearly 40 years, is popular today in neonatal intensive care units, nurseries and even delivery rooms, in industrialized countries. Nasal CPAP therapy provides and maintains an elevated pressure baseline (CPAP) at which a neonatal patient breathes throughout the respiratory cycle. The advantages of the new elevated pressure baseline include a significant reduction of the patient s breathing efforts required to meet their physiological needs, stabilization of the airway, restoration of the FRC, and correction of hypoxemia. The therapy, if properly applied, often relieves the patient s dyspnea effectively and quickly. Nasal CPAP systems Nasal CPAP systems are a specialized set of clinical tools to facilitate nasal CPAP therapy. They fall into two categories: classic nasal CPAP systems with constant flow and advanced nasal CPAP systems with variable flow. Advanced nasal CPAP further reduces work of breathing and improves patient comfort. HAMILTON MEDICAL s ARABELLA Bringing together its engineering expertise and clinical knowledge, HAMILTON MEDICAL has pioneered the development of advanced nasal CPAP systems. Over a thousand of ARABELLA systems are in active use in hospitals around the world to help numberless newborn babies come through the first, perhaps the most difficult, phase of their lives.

Monitoring Gas Mixer Heated delivery circuit Caps available in five sizes Universal Generator Active humidifier Five-leg stand

www.hamilton-medical.com/arabella A complete system Patient interface (nasal prongs or masks in different sizes) ARABELLA is a complete advanced nasal CPAP system, which is composed of the following parts: 1. Monitoring Gas Mixer (the flow driver) 2. Universal Generator 3. Patient interface such as a nasal prong or a nasal mask 4. Heated delivery circuit 5. Active humidifier and accessories 6. Elastic cap for fixation of Universal Generator and patient interface 7. Five-leg stand 8. Gas hoses and connectors 9. Operator s manual and multimedia training materials. In comparison with other nasal CPAP systems, the ARABELLA provides the following advantages: - Patented, effective and lightweight Universal Generator with minimal dead space - A full range of sizes of nasal prongs, nasal masks and caps for optimal fitting of individual patients - Compact, quiet, easy-to-operate Monitoring Gas Mixer (the flow driver) with precise control of gas flow delivery and oxygen concentration, proximal pressure and oxygen monitoring, and integrated alarms and reliable safety mechanisms. Monitoring Gas Mixer supports an additional flowmeter that permits the delivery of blended gases through a low-low cannula, manual resuscitator, or oxygen hood or for nebulizer therapy. - Elastic caps for easy and optimal fixation, allowing the baby s free movement - Single-patient use accessories to eliminate the risk of cross-contamination - Proven effectiveness and safety of the entire system

Mixed gas inlet Expiratory gas Proximal pressure port for monitoring Injector jet To patient via a nasal prong or nasal mask

www.hamilton-medical.com/arabella Variable flow: The magic of the Universal Generator During nasal CPAP therapy, a neonatal patient breathes spontaneously at an elevated pressure baseline throughout the respiratory cycle. With classic nasal CPAP therapy with constant flow, the patient s inspiratory effort creates a pressure drop, and the expiratory effort creates a pressure rise. Such pressure fluctuations represent additional patient work of breathing. With variable flow, the flow toward the patient increases slightly during inspiration and decreases slightly during exhalation. As a result, the pressure baseline fluctuates less during spontaneous breathing, reducing work of breathing. This phase-related flow variation results from the Universal Generator s unique design, which exploits three physical laws: the Bernoulli effect, the Venturi principle and the Coanda effect. Inspiration A jet of air flows at a constant speed for a certain distance before it disperses its kinetic energy into the atmosphere (Bernoulli). The ARABELLA takes advantage of this effect by incorporating individual injector jets directed at each nasal passage to maintain a constant NCPAP throughout the respiratory cycle. During inspiration, flow toward the injector jets provides inspiratory flow for the patient. At high inspiratory demand, additional flow is entrained by the venturi action of the injector jets. Exhalation Upon exhalation, flow beyond the portals (into the passageway) enters a low-pressure area with minimal backpressure, resulting in decreased flow. The decreased flow causes the gas to reverse its direction or flip, resulting in exhalation. The unique pressure flow stalling characteristics of the dualinjector jets allow the patient to passively exhale without additional imposed work. The constant gas flow provides a residual gas pressure to ensure stable NCPAP delivery thoughout the respiratory cycle.

Technical specifications ARABELLA Monitoring Gas Mixer (the flow driver) Controls Flow 0 to 10 l/min Oxygen 21 to 100% Monitoring NCPAP 0 to 12 cmh 2 O Oxygen 21 to 100% Alarms High pressure Low pressure High and low oxygen Gas supply Alarm silence Internal pop-up valve 3 cmh 2 O above set NCPAP level 2 cmh 2 O below set NCPAP level Independent zero pressure alarm ±5% of set oxygen level Active if pressure difference between two gas supplies exceeds 1.38 bar / 20 psi /138 kpa, e.g., if one gas supply fails 30 seconds Opens if system pressure > 150 cmh 2 O Patient pressure relief valve Opens if monitored NCPAP exceeds 11 cmh 2 O. and alarm (Flow delivery resumes after 3 seconds) Acoustic alarm volume Electronic displays Brightness Monitored CPAP Monitored oxygen Gas and electric supply Air and oxygen supply Electric power Approximately 51.5 db(a) Automatic dimming ±1 cmh 2 O in resolution ±1% in resolution 2 to 4.8 bar / 29 to 70 psi / 200 to 480 kpa Maximal acceptable pressure difference between air and oxygen supplies: < 1.38 bar / 20 psi / 138 kpa 100 to 240 VAC, 50 / 60 Hz, 45 VA Physical characteristics Dimensions (W x D x H) Weight Environment Operating temperature Storage temperature Atmospheric pressure 210 x 175 x 145 mm 6.2 kg 10 to 40 C at 0 to 75% relative humidity, non-condensing -10 to 60 C at 0 to 75% relative humidity, non-condensing 700 to 1060 hpa / 10 to 15 psi Major standards IEC 60601-1, IEC 60601-1-2 Accessories for ARABELLA Universal Generator set Contains a generator assembly, nasal prongs, KNOSCUSHION, and other items Delivery Circuit Types* 3 types (16 V, 21 V, and 28 V) Compatible humidifier models Fisher & Paykel MR730 and MR850 Elastic positioning cap sizes 1 (small, S), 2 (medium, M), 3 (large, L), 4 (extra large, XL) and 5 (extra extra large, XXL) Nasal masks sizes 0 (small, S), 1 (medium, M), and 2 (large, L) Nasal prongs sizes Five-leg stand Small (S), medium (M), large (L), and extra large (XL) Pole mount for ARABELLA Monitoring Gas Mixer (flow driver) *Subject to change. Visit www.hamilton-medical.com/arabella for an updated list. 689119/05 Specifications are subject to change without notice. ARABELLA is a trademarks of HAMILTON MEDICAL. HAMILTON MEDICAL AG 2011. All rights reserved. Printed in Switzerland. HAMILTON MEDICAL AG, Via Crusch 8, CH-7402 Bonaduz, Switzerland (+41) 81 660 60 10 (+41) 81 660 60 20 info@hamilton-medical.com, www.hamilton-medical.com, www.intelligentventilation.org