Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Similar documents
Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Stainless steel ASTM A351 CF8M

Materials : Carbon steel ASTM A216 WCB

Materials : Forged carbon steel A105N

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Materials : Galvanized steel flanges

Materials : Electro galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Materials : Forged carbon steel A105N

WATER METERS.

Materials : Dichromate zinc plated steel flanges or AISI 316

Forged stainless steel ASTM A182 F316

Materials : Dichromate zinc plated steel flanges

Materials : Brass body dezincification-resistant up to DN1 1/4

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

GUKO FDA. einfach. gut. beraten.

GUMMIKOMPENSATOR GKF8000 / GKF8130

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Materials : Brass body dezincification-resistant

Flanged pressure reducer/stabilizer VRCD

KTM 50 (DN ) Installation, maintenance and operating instructions

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

TP1 and TP2 Temporary Cone Shaped Strainers

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

TECHNICAL ACCESSORIES

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

756 Safety Relief Valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

CA10S, CA14 and CA14S Air and Gas Traps

Air Eliminators and Combination Air Eliminators Strainers

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Pressure Independent Control Series

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Pilot Operated Pressure Reducing Valve

Type overview. R B2 en-gb subject to changes 1

STAINLESS STEEL OVERFLOW VALVE TYPE 417

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

SCA Series Inverted Bucket Steam Traps

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

Norval Pressure Regulators

Safety Shut-Off Valve HON 720

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

VALVES HIDROMATIC VALVE.

STAP. Differential pressure controller DN

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

776 Cryogenic Safety Valve

HYDRAULIC CONTROL VALVES

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Dival 600. Pressure Regulators

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Pressure Reducing Valve for Steam Type 2333 A

CLASS TLP Pressure Reducing Valve

S and SF Inverted Bucket Steam Traps

pren CEN standard-draft pr EN 12261

STAP. Differential pressure controllers DN , ANSI flanges

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Gas Pressure Regulator R 51

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

STAG. Balancing valves Balancing valve with grooved ends DN

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

SRV66 Sanitary Pressure Reducing Valve

AVP-F. p setting range (bar) Code No. 003H6200

Transcription:

Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic transmission Materials : Cast iron body Page 1 sur 7

SPECIFICATIONS : Tangential type with removable insert Pre-equipped for pulse emitter A Class for horizontal position with horizontal dial ( respect the flow direction indicated by the arrow ) Negligible head loss Dry dial Magnetic transmission Direct reading on numerical rolls With lid Cast iron body USE : Irrigation Min and max Temperature Ts : 0 C to + 50 C Max Pressure Ps : 16 bars HEAD LOSS : mbar Flow (m3 / h) TYPICAL ERROR CURVE : Qmin : Min flow Qt : Transitional flow Qmax : Max flow Page 2 sur 7

RANGE : Cold water flanged R.F. ISO PN10/16 up to DN150, ISO PN16 for DN200 type Ref.1720 DN 50 to 200 MATERIALS : Item Designation 1 Lid 2 Cap 3 Mechanism with PC and glass 5 mm 4 Clamp 5 Ring nut 6 Separation plate 7 Magnetic transmission 8 O-ring 9 Adjusting shaft 10 Upper insert 11 Adjusting device 12 Lower insert 13 Turbine 14 Cast iron body Page 3 sur 7

DIAL : SIZE ( in mm ) : Ref. DN 50 65 80 100 125 150 200 L 200 200 225 250 250 300 350 1720 h 80 92.5 100 110 125 142.5 170 H 150 150 150 150 150 152 195 Weight (Kg) 11.5 13 15 19 24 30 48 Page 4 sur 7

FLANGES SIZE ( in mm ) : Ref. DN 50 65 80 100 125 150 200 Ø C 102 122 138 158 188 212 268 Ø D 165 185 200 220 250 285 340 1720 Ø K 125 145 160 180 210 240 295 Nb x Ø L 4 x 18 4 x 18 8 x 18 8 x 18 8 x 18 8 x 22 12 x 22 b 20 18 20 20 22 22 23 e 2 2 2 2 2 2 2 TECHNICAL FEATURES : DN 50 65 80 100 125 150 200 Max flow rate Q max ( m3/h) 70 100 150 250 350 500 900 Nominal flow rate Qn ( m3/h ) 35 50 75 125 175 250 450 Min flow rate A Class Q min with ± 5% error ( m3/h ) Transitional flow rate A Class Qt with ± 2% error ( m3/h ) 2.8 4 6 10 14 20 36 10.5 15 22.5 37.5 52.5 75 135 Min reading ( m3 ) 0.005 0.005 0.005 0.005 0.005 0.005 0.005 Max reading ( m3 ) 9999999 9999999 9999999 9999999 9999999 9999999 9999999 STANDARDS : Fabrication according to ISO 9001 : 2008 ICIM and IQNET Flanged according to EN 1092-2 PN16 DIRECTIVE 97/23/CE : Products excluded from directive ( article 1, 3.2 ) ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 5 sur 7

INSTALLATION INSTRUCTIONS OF WATER METER BEFORE INSTALLATION : Pipe-line must be cleaned and free from residual of weldings,rubbish,shaving and every kind of extraneous materials. Pipe-line must be perfectly aligned and their support properly dimensioned so that there s no external constraint. Tighten the bolts in cross Use the right bolt tightening so that the ends won t be damaged. It s recommended to install a strainer before the water meter if there are some solid particles in the water. Installation of the meters in the vicinity of pumps must be avoided. It is advisable to install the meter as far as possible from them. Make sure all the water supply outlets, served by the meter, sit higher than the meter itself otherwise its metering precision could be altered. The highest position of the count itself as the recording of the counter may not be reliable. To address these possibilities, simply place the meter after a 'large upward curve that ensures always a pipe completely filled with water (Fig 1). This will prevent air bubbles that could affect the accuracy of measurement Respect the flow direction indicated by the arrow. We recommend installing a valve downstream and one upstream of the meter in order to facilitate a possible maintenance of the meter itself, without having to drain the complete pipeline. During the water meter commissioning it is advisable to open first the valve placed downstream of the meter (so to flood the mechanical part of the instrument) and then slowly open the valve located upstream of the meter. This will prevent possible water hammers or acceleration of the flow that could damage the moving parts of the instrument. In the event of devices installed upstream of the water meter (gate valves, curves, elbows, tees, reducers,...) it is recommended to follow the following points. These devices can generate flow turbulence that in the long run may damage the moving parts of the measuring instrument. The L1 and L2 lengths above are considered the minimum necessary. When possible, you should increase them. Valves placed upstream and downstream Upstream bottleneck Curve or T fitting Upstream bottleneck with conical fitting Page 6 sur 7

INSTALLATION POSITIONS (SUITE) : Two curves or one curve and T fitting Upstream increased pipeline Free discharge downstream TESTS : During the tests under pressure, water meter must be removed to avoid overpressure risks. INSTALLATION Please make the water flow slowly to avoid water hammer. The meter pit shall be protected from flooding, rainwater and frost. INSTALLATION POSITIONS : HORIZONTAL : A Class Page 7 sur 7