Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor Using Single and Dual Impeller Configurations

Similar documents
Structure of Mechanically Agitated Gas-Liquid Contactors

Bioreactor System ERT 314. Sidang /2011

CFD SIMULATIONS IN AN INTERNAL CIRCULATION AIRLIFT OPERATING UNDER HOMOGENEOUS REGIME

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

Hydrodynamic and Mass Transfer Characteristics of External-Loop Airlift Reactors without an Extension Tube above the Downcomer

Bioreactor System ERT 314. Sidang /2012

CFD STUDY OF SLURRY HOMOGENIZER

Oxygen mass transfer in a bubble column with non-newtonian fluids

1. Introduction (1) (2)

Flow behavior of wakes in a three-phase slurry bubble column with viscous liquid medium

A Review on Hydrodynamics of Gas Inducing Mechanically Agitated Contactors.

Journal of Chemical Engineering of Japan, Advance Publication doi: /jcej.12we164; published online on July 25, 2012

Bubble Coalescence and Breakup in Gas-Liquid Stirred Tank Reactors

Gas-liquid mass transfer in an external airlift loop reactor for syngas fermentation

Energy Efficiency and Mixing Time Calculations in Mechanically Agitated Liquid Liquid Contactors

VISIMIX TURBULENT. MECHANICAL CALCULATIONS OF A CONSOLE SHAFT

CFD Simulation of Gas-Liquid in an Agitated Vessel

The effect of two inclined circular plunging jets on air entrainment in an aeration tank

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

VISIMIX LAMINAR. BLENDING OF NON-NEWTONIAN LIQUID. POWER. CIRCULATION. MIXING TIME.

Mixing in the Mechanically Agitated Bioreactor: A Matter of Being Stirred, not Shaken

ON THE DEGASSING KINETICS IN A LADLE EQUIPPED WITH A ROTATING IMPELLER ASSISTED THROUGH PHYSICAL MODELING

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Experimental Study of an Air Lift Pump

International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 01, Pages 56-60, 2015

VISIMIX TURBULENT. LIQUID - SOLID MIXING. DEFINING JSS (JUST SUSPENSION SPEED)

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

International Journal of Scientific & Engineering Research, Volume 5, Issue 4, April ISSN

Measurements of k L a. Steady-State Mass Balance Method:

Simulation of Gas Holdup in a Bubble Column with a Draft Tube for Gas Dispersion into an Annulus

World Academy of Science, Engineering and Technology International Journal of Chemical and Molecular Engineering Vol:7, No:12, 2013

EXPERIMENTAL ANALYSIS OF THE CHOSEN PARAMETERS EFFECTS ON A GAS HOLD UP FOR MECHANICALLY AGITATED TWO- OR THREE-PHASE SYSTEMS

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

of air-lift reactors based on bubble dynamics

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

Gas-liquid flow characteristics study on the amino acid fermentation tank

IMAGE PROCESSING TO DETERMINE MASS TRANSFER COEFFICIENT FOR GAS BUBBLE

Experimental Investigation Of Flow Past A Rough Surfaced Cylinder

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Low gas volume & flow measurements made easier Gas Endeavour

Validation Study of Gas Solubility Correlations at bubble point pressure for Some Libyan Crude Oils Using Three chosen Correlations

COMPUTER-AIDED DESIGN AND PERFORMANCE ANALYSIS OF HAWT BLADES

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Effects of surfactant on bubble size distribution and gas hold-up in a bubble column

Numerical Simulations of Bubbling Fluidized Beds

ENGG 199 Reacting Flows Spring Lecture 2a Blending of Viscous, Newtonian Fluids

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump

EFFECTS OF CHEMICAL ADDITIVES ON THE PRESSURE DROP IN THE PIPES

Multiple effects of operating variables on the bubble properties in three-phase slurry bubble columns

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

ExperimentalDeterminationofBubbleSizeinSolutionofSurfactantsoftheBubbleColumn

Computational fluid dynamics analysis of a mixed flow pump impeller

ON THE EFFECT OF LIFT FORCES IN BUBBLE PLUMES

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Laboratory studies of water column separation

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Workshop 1: Bubbly Flow in a Rectangular Bubble Column. Multiphase Flow Modeling In ANSYS CFX Release ANSYS, Inc. WS1-1 Release 14.

A07 Surfactant Induced Solubilization and Transfer Resistance in Gas-Water and Gas-Oil Systems

PVP EXPERIMENTAL AND CFD EVALUATION OF A BUBBLE COLUMN REACTOR

Energy and mass transfer in gas-liquid reactors.

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

AN INVESTIGATION OF SPARGED MIXING TANKS USING ELECTRICAL IMPEDANCE TOMOGRAPHY AND COMPUTATIONAL FLUID DYNAMICS

Figure 1 Schematic of opposing air bearing concept

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

CFD SIMULATION OF GAS-LIQUID HYDRODYNAMICS IN AERATED STIRRED TANK AZRI ABDULLAH. A thesis submitted in fulfillment of

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

CFD Analysis of Giromill Type Vertical Axis Wind Turbine

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

CRYSTALLIZATION FOULING IN PACKED COLUMNS

Measurements of Gas-Liquid Mixing in a Stirred Vessel Using Electrical Resistance Tomography (ERT)

A numerical Euler-Lagrange method for bubble tower CO2 dissolution modeling

Performance Analysis of Centrifugal Compressor under Multiple Working Conditions Based on Time-weighted Average

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

3D Simulation and Validation of a Lab Scale Bubble Column

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

Purpose of application of the program VisiMix Laminar finding a way to increase volume of the batch without overloading the motor.

Transitional Steps Zone in Steeply Sloping Stepped Spillways

Bioreactors Prof G. K. Suraishkumar Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 15 Bioreactor env.par.

A STUDY OF MULTISTAGE/MULTIFUNCTION COLUMN FOR FINE PARTICLE SEPARATION. Duration: July 8, July 7,1997 ) Submitted to

Bubble Coalescence and Breakup Modeling for Computing Mass Transfer Coefficient

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Effect of Nozzle Twisted Lance on Jet Behavior and Spitting Rate in Top Blown Process

Copyright Warning & Restrictions

Aerodynamic Analysis of a Symmetric Aerofoil

Study on Mixing Property of Circulation/Shear Coupling Mechanism-Double Impeller Configuration

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Transcription:

2008-5435/13/53-109-116 INTERNATIONAL JOURNAL OF OCCUPATIONAL HYGIENE Copyright 2013 by Iranian Occupational Health Association (IOHA) IJOH 5: 109-116, 2013 ORIGINAL ARTICLE Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor Using Single and Dual Impeller Configurations ALI KARIMI 1, 2, FARIDEH GOLBABAEI 2*, MOHAMMAD REZA MEHRNIA 3, KAZEM MOHAMMAD 4, MASOUD NEGHAB 1, AHMAD NIKPEY 5, and MOHAMMAD REZA POURMAND 6 1 Occupational Health Department, School of Public Health and Nutrition, Shiraz University of Medical Sciences, Shiraz, Iran; 2* Occupational Health Eng. Department, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran; 3 Biotechnology Group, School of Chemical Engineering, University College of Engineering, University of Tehran, Tehran, Iran; 4 Epidemiology and Biostatistics Department, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran; 5 Occupational Health Department, School of Public Health, Qazvin University of Medical Sciences, Qazvin, Iran; 6 Pathobiology Department, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran. Received January 27, 2013; Revised April 19, 2013; Accepted June 3, 2013 This paper is available on-line at http://ijoh.tums.ac.ir ABSTRACT A laboratory stirred tank bioreactor with six single and dual-impeller configurations was tested to obtain the optimum operating conditions for future biological processes. Six impeller combinations consisting of three basic impeller types, namely Rushton turbine (RT), pitched 4blade (P4B) and pitched 2blade (P2B) downward flow were investigated in 1.77 L bioreactor working volume. Power consumption and gas holdup measurements were taken over a range of 100-1000 rpm of stirring speed and 1-5 Lmin -1 of air flowrates, for all the six combinations consisting of any single and dual impellers. Using predicted data some empirical correlations were derived which present relations in estimation of power consumption in stirred tanks with various impeller configurations. Electrical measurement method was use to determine the power drown in the stirred bioreactor. Gas hold-up increased with an increase in stirring speed and superficial gas velocity for all the impellers employed. The number and type of impellers in stirred bioreactor had considerable influence on gas hold-up behavior of the stirred bioreactor. Besides, Rushton turbine-dual Impeller gave comparably maximum gas hold-up, but at significantly higher power consumption levels. The proposed correlations offered good agreement with the experimental data. Keywords: Gas hold-up, Stirred bioreactor, Power consumption, Dual-impeller INTRODUCTION Stirred tanks as a means of mechanical agitation for mixing of bioreactor media are one of the most commonly used equipment in biotechnology [ 1]. The most common equipment used for effective contact * Corresponding author: Farideh Golbabaei, E-mail: fgolbabaei@razi.tums.ac.ir between gas and liquid phases in chemical and biochemical processes is Rushton turbine agitated vessel [ 2, 3 ]. Although the Rushton turbine has been used for decades as reactor agitation tool, several designs have been developed to enhance and optimize gas liquid contact in recent years. In full-scale reactors, multiple impellers are often used with either impellers of the same type or a combination of novel and traditional blades [ 4]. Several researches declared that multi- IJOH July 2013 Vol. 5 No. 3 109-116

110 IJOH July 2013 Vol. 5 No. 3 Karimi et al. Fig 1. Schematic view of stirred tank bioreactor used in this study impeller gas liquid reactors have been found ensuring higher efficiency of gas utilization and longer retention time of gas than single impeller systems [ 5]. Breaking up of bubbles is mainly caused by stirrer speed and the mixing intensity in bioreactor vessels [ 6]. Gas hold-up and mass transfer between several phases of reactor media very closely linked to each other. Gas hold-up is defined as a measure of the efficiency of gas liquid contacting. Several variables such as: vessel and impeller design, impeller speed (power input), gas velocity and liquid physical properties may influence the rate of gas hold up in an impeller agitated reactor [ 7 ]. The effect of impeller design on gas hold-up in water and viscous liquids have been investigated in several studies. Khare et al. showed that impeller selection remains critical from the point of view of generating gas hold-up, even in the coalescence inhibited high viscosity, especially at the lower gas velocity. They also found that total gas hold-up in Carboxyl Methyl Cellulose solution increases with impeller speed at different gas velocities [ 7]. Gas holdup, mixing intensity of dispersion and gas liquid volumetric mass transfer coefficient for 18 impeller configurations in triple-impeller have been studied by Tomoa et al. They found that the impeller configurations with low power number provide higher dispersion mixing intensities, while the impeller configurations with high power number provide better mass transfer performance [ 8]. Dohi et al. used Rushton turbines and pitched blade impellers (four impellers on a common shaft) [ 9 ]. Several Pitched blade impellers on a common shaft have also been used by Saravanan et al. who selected them as the most effective ones from several types tested [10, 11]. The axial impellers to compare with the radial ones are more efficient from view point of mixing performances [ 8]. Power consumption in stirred tank bioreactors is known as one of the most important design parameters which is influence by several factors such as: the physical properties, operating and geometrical parameters of the of equipments. Most of the studies announced that being aware of power consumption of the stirring equipments may lead to better decision making on operating conditions so, achieving the needed mixing process with a minimum expenditure of energy and cost is of great concern [12, 13]. It was said that electrical power play major role to the overall manufacturing cost of a bio-filtration process. Also other parts of equipments air such as compressors and circulation pumps need electrical energy; but the major consumer is the agitator agent. Given this background, it is evident that study on the effect of impeller design on gas hold-up and power consumption in bioreactors is advantageous. This study is devoted to optimization of agitation and aeration conditions in a system with geometrical configuration commonly used in laboratory scale stirred tank bioreactors with mixing equipment consisting of single and dual impellers on a single shaft. The performance was assessed on the basis of gas hold-up, which is a basic measure of the efficiency of gas-liquid contacting and, at the same time, very closely linked with mass transfer. The aim of this work is to compare the power dissipation and its effect on gas hold-up, which in turn decides the gas-liquid interfacial area for various combinations of impellers. The optimum combination can then be selected for industrial bioprocesses with total confidence.

Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor ijoh.tums.ac.ir 111 Fig 2. Schemes and details of the impellers: a: Standard Rushton turbine with vertical Blades (RT), b: Pitched 4blade (P4B), c: Pitched 2blade (P2B) MATERIAL AND METHODS The Stirred Bioreactor in detail The experimental conditions have been selected in order to generate efficient mixing condition inside the tank. A schematic diagram of the stirred tank bioreactor is shown in Fig. 1. The semi-circle bottom cylindrical tank was made of transparent glass with an internal diameter of 10 cm and ratio H b : T i = 3 fitted with four T i /10 wide vertical wall baffles symmetrically. The distance between impellers is chosen equal to the tank diameter in order to avoid interaction between them [ 14]. The experiments were performed at room temperature and atmospheric pressure. De-ionized water (28±0.5 C) was used as the liquid phase and filtered air was supplied to the system through an orifice sparger contains 9 orifices with total open area of 0.28 cm 2, located 5 cm (T i /2) below the lower impeller. In mechanically agitated reactors, the impeller is the main gas-dispersing tool and will naturally have a pronounced effect on mass transfer characteristics of the system [15]. Also it was recommended that the impeller must be located neither close to the dispersion device nor close to the free surface [13]. Three types of impellers, namely, Rushton turbine (RT), Pitched 4blade (P4B) and Pitched 2blade (P2B) impellers (blade angle 45 ) with downward pumping (Fig 2) were tested with 1.77 L total working volume of aqueous phase in order to evaluate their effect on the gas hold-up and power consumption in the bioreactor. Aeration rates ranging from 1 to 5 L min -1 were tested in ten agitation speeds (100, 200, 300, 400, 500, 600, 700, 800, 900 and 1000 rpm). Gas hold up Gas hold-up (ε) as an important design parameter of a reactor is defined as the ratio of the gas phase volume to the total volume. This parameter accompanies with information regarding to mean bubble diameter used to calculate the gas-liquid interfacial area and so has noticeable effect on the mass transfer coefficient (K L a) [ 13, 16]. The overall gas hold-up at a given impeller speed and gas velocity was determined by visual measurements using the volume expansion method [17]. This was quantified by measuring the difference between the volume of un-aerated and aerated liquid. The gas hold-up was computed from the following equation [ 18]: H H0 (1) H 0 Where, ε is the gas hold-up, H 0 is the un-gassed column height (m) and H is the column dispersion height due to the presence of gas bubbles (m). Power consumption Looking at the literature, it was found that the most frequently used techniques for the evaluation of power consumption in stirred tanks and fermentors are wattmeters, ammeters, colorimeters, dynamometers, torquemeters and systems based on strain gauges. Each of these systems has its own advantages and disadvantages, and is chosen based on some factors such as investment, scale, precision, and range of measurement. The first technique is electrical measurement that used for power draw quantifications by wattmeters and ammeters directly in the motor of stirred vessels. For the case of direct current motors (DC), the power draw by an electrical device is simply the result of the supplied voltage (V) and the current greatness (I). Power consumption in these networks could be calculated by an ammeter, as well as directly by means of a wattmeter [ 12]. In the present work the stirring power input was measured by electrical measurement method, using a circuit control that monitored the electrical current (A) and voltage (V) of the DC stirrer motor mounted on the bioreactor that is presented in Fig 1. RESULTS The effect of impeller combination and power on gas hold-up was studied for several impeller configurations. The results are represented in Fig 3. As

112 IJOH July 2013 Vol. 5 No. 3 Karimi et al. 8.000 7.000 RT, 1 Impeller 1 RT, 2 Impeller 1 8.000 0.0 2.0 4.0 6.0 8.0 10.0 12.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 4.500 P4B, 1 Impeller P4B, 2 Impeller 3.500 2.500 1.500 0.500 0.0 1.0 2.0 3.0 4.0 5.0 6.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 4.500 P2B, 1 Impeller P2B, 2 Impeller 3.500 2.500 1.500 0.500 8.000 1 1 Fig 3. Gas hold-up as a function of power consumption per unit volume with flowrates of 1 to 5 Lmin -1 using three types of impellers (RT, P4B and P2B) in 6 different single and dual configurations.(1 Lmin -1, 2 Lmin -1, 3 Lmin -1, 4 Lmin -1, 5 Lmin -1 ) seen from this figure, the gas hold-up increases with increase in flowrate, although the trend is the same for all flowrates (1 to 5 L/min). Also the extent of the increase is much higher at higher flowrates. A reduction of power consumption is notable with increase of gas flowrate in each impeller configuration. This reduction for RT 2 impeller composition is about 30% in flowrate of 5 L/min to compare with 1 L/min. In addition, Fig 3 shows gas hold-up increment of 40 to 120% in lower and higher gas flowrates respectively in RT 2 impeller to compare with RT 1 impeller configuration. The RT 2 impeller vs. P4B and P2B in Fig. 3 appears an increase of 90 and 100% of gas holdup in RT 2 impeller to compare with P4B and P2B respectively. Comparison of single and dual impeller configurations of P4B and P2B in Fig. 3 shows an

Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor ijoh.tums.ac.ir 113 Q= 1 L/min Q= 2 L/min 0.0 5.0 10.0 15.0 20.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 Q= 3 L/min Q= 4 L/min 0.0 2.0 4.0 6.0 8.0 10.0 12.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 Q= 5 L/min 0.0 2.0 4.0 6.0 8.0 10.0 12.0 Fig 4. Power consumption comparisons of three types of impellers (RT, P4B and P2B) in 6 different single and dual impeller configurations with flowrate of 1 to 5 Lmin-1(RT single impeller, RT twin impellers, P4B single impeller,p4b twin impeller, P2B single impeller, P2B twin impeller ) increase of 20 to 30% in dual configurations. Also, Fig 4 approves the difference of gas hold-up rates in difference impeller configurations. Predictions of the absorption rate of a gaseous species in a stirred tank are usually based on correlations of overall volumetric mass transfer coefficient (K L a) and gas hold-up with mechanical agitation power per unit volume (P g /V L ) and gas sparging rate that expressed as the superficial velocity (V g ) [ 6 ]. The power input per unit volume (P g /V L ) and,

114 IJOH July 2013 Vol. 5 No. 3 Karimi et al. Table 1. Calculated constants and Exponents of Eq. 2 for 6 impeller configurations. Gas hold-up exponents of Eq. 2 Configuration α β c R 2 RT, single impeller 21.6 0.56 1.03 0.92 RT, dual impeller 2.11 0.48 0.67 0.97 P4B, single impeller 2.73 0.36 0.74 0.94 P4B, dual impeller 2.64 0.46 0.74 0.97 P2B, single impeller 7.74 0.37 0.86 0.95 P2B, dual impeller 4.25 0.57 0.86 0.93 superficial gas velocity V g are major factors in gas holdup correlations. There are a lot of proposed equations for the fractional gas hold-up as a function of different variables in previous studies [ 8, 19, 20]. Also frequent disagreements between experimental data and those estimated from these equations are found. This can be as the results of strong impact of the style and size of bioreactors, the different range of operational circumstances, the system considered solutions or real broths, the influence of physicochemical specifications on hydrodynamics due to high viscosity of the liquid, its rheological behavior or even the measuring technique used [ 6 ]. The following equations are frequently found in the literature [ 8, 19, 20]: Pg c g ( Vg ) V (2) L Where, P g is the mechanical agitation power in gas liquid dispersion (W); V L represents liquid volume (m 3 ); V g, gas superficial velocity (m s -1 ); α, constant; β and c is exponents. In this present work on the base of these concepts, some empirical correlations for the gas hold-up rate in the bioreactor with three type of single and dualimpellers are developed and gas hold-up values obtained from the experimental data were plotted against the operating variables and mathematical correlations which describe the influence of the studied parameters on the gas hold-up have been established in order to predict biodegradation performances. These correlations ware developed using Datafit 9 software. Fig 5 plots the experimental gas hold-up for three types of impellers, the RT, P4B and P2B with single and dual impeller configurations, versus calculated gas holdup using Eq. (2) for different gas flow rates (1 to 5 Lmin -1 ) and agitation speeds (100 to 1000 rpm). In this Figure the proposed correlation offers a good agreement with the experimental data with an average deviation of ±8 %, which presents the predicted versus the experimental results. DISCUSSION The gas hold-up gives the volume fraction of gas phase in the reactor and thus gives the mean value of residence time for the gas phase. The effect of impeller combination and power on gas hold-up was studied for several impeller configurations. In Fig. 3 it was found that the number of impeller in stirred bioreactor has considerable influence in gas hold-up specifications. Also it revealed that type of impeller has the most efficient impact on gas hold-up behavior of stirred bioreactor. It is clear from Fig. 4 that even though the maximum values of gas hold-up vary markedly between the impellers tested, the power for gas dispersion is also significantly different. Based on the power consumption Experimental Gas Hold Up (m) 0.12 0.1 0.08 0.06 0.04 0.02 RT 2 Impellers P4B 2 Impellers P2B 2 Impellers RT 1 Impeller P4B 1 Impeller P2B 1 Impeller 0 0.E+00 2.E-02 4.E-02 6.E-02 8.E-02 1.E-01 1.E-01 Calculated Gas Hold Up (m) Fig 5. Correlation between the experimental and calculated values of gas hold up for single and dual impeller of RT, P4B and P2B in six configurations, agitation rates from 100 to 1000 rpm and aeration rates from 1 to 5 Lmin -1

Investigation of Gas Hold up and Power Consumption in a Stirred Tank Bioreactor ijoh.tums.ac.ir 115 value, it is evident that RT dual impeller gives comparably maximum hold-up, but at significantly higher power dissipation levels. In other words, Rushton turbine impellers appear to be superior to pitched blade turbine under these conditions. At the higher gas velocity, the picture is somewhat similar to Fig. 4, however the holdup values is also correspondingly higher (Figures not shown). In this study, it was considered the case where the objective was to choose an impeller which gave the highest gas hold-up. If we now consider the case where an impeller is to be selected Rushton turbines generate higher gas hold-up than pitched blade at all studied gas velocity, and dual impeller configurations showed superior performances to compare with single impeller configurations. Thus, Rushton turbine-type dual impeller can demonstrate better performance over other compositions with regard to generating gas hold-up in low viscous non-newtonian liquid. Changing gas flow rate will also affect the K L a values of a bioreactor by changing the fractional gas hold-up and hence the gas-liquid interfacial area. It was observed that with an increase in the gas flow rates, the gas hold-up values increased (Fig. 3). Similar results were obtained with single and dual impeller systems. Also, the results presented in Fig. 3 illustrate that for RT impeller type the gas hold up increment trends in different aeration rates(1-5 Lmin -1 ), begins from a highly sloped curve in lower agitation rates( lower power consumption) and continue to increase, then this trend approaches to a plateau in 900 and 1000 rpm( higher power consumption). On the other hands in pitched blade impellers the gas hold-up increment trends in different aeration rates (1-5 Lmin -1 ), begin with a sloped line and this slop is maintained to all agitation speeds. The constants obtained from the correlations of the 6 single and dual impeller configurations are shown in table 1. The exponent over (P g /V L ) increased with single to dual impeller configurations in pitched blade impellers, indicating more effective utilization of the power with multiple impeller systems. No significant effect was observed on the exponent over V g for single and dual impeller systems especially in pitched blade impellers. In the gas hold-up data we can find many trends with number and type of impellers so it is not easy to make general conclusions about multi-impeller vessels design from the gas hold-up data. Empirical correlations for gas hold-up depend on several geometrical parameters, although there is no conformity in the literature about how to take into accounts this influence [ 8 ]. CONCLUSION The objectives of this work were to study the behavior and the performances of several impeller configurations. It was found that the number of impeller in stirred bioreactor has considerable influence in gas hold-up specifications. Also the result illustrated that the gas hold-up increases with increase in gas flowrate. From the above discussion it is clear that Rushton turbine-type impellers running in non-newtonian liquid, gives the highest gas hold-up. It is therefore desirable to operate this impeller, preferably in order to ensure that the gas bubbles are fully dispersed throughout the liquid. As the results have shown, dual Rushton turbine represents an average enhancement on the gas hold-up values of 90 and 100% with respect to P4B and P2B impellers respectively. Based on the power consumption value, it was found that RT dual impeller gives comparably maximum gas hold-up, but at significantly higher power dissipation levels. The proposed correlation offers good agreement with the experimental data with an average deviation of ±8%, which presents the predicted versus the experimental results. ACKNOWLEDGMENT The support of Tehran University of Medical Sciences for supplying funds of this project is appreciated. The authors declare that there is no conflict of interest. Nomenclature α, b, c, Exponents in Eq. (2) ε Gas hold-up H 0 ungassed column height (m) H column dispersion height due to the presence of gas bubbles (m) T i bioreactor internal diameter (cm) H b bioreactor height (cm) N impeller rotation speed (rpm) P power consumption for mixing of non-aerated (W) P g power consumption for mixing of aerated (W) Q volumetric air flow rate (Lmin -1 ) P g / V L specific power input (WL -1 ) V g superficial air velocity (m s -1 ) V L Volume of the liquid in the Vessel (L) REFERENCES 1. Taghavi M, Moghaddas J, Moghaddas Y. Experimental and CFD investigation of power consumption in adual Rushton turbine stirred tank. Chem Eng Res Des 2010; 89(3): 280-290. 2. Sanchez A, Martinez A, Torres L, Galindo E. Power- Consumption of 3 Impeller Combinations in Mixing Xanthan Fermentation Broths. Process Biochem 1992; 27(6): 351-365. 3. Khare AS, Niranjan K. An experimental investigation into the effect of impeller design on gas hold-up in a highly viscous Newtonian liquid. Chem Eng Sci 1999; 54(8): 1093-1100. 4. Pinelli D, Bakker A, Myers K J, Reeder MF, Fasano J, Magelli F. Some features of a novel gas dispersion impeller in a dualimpeller configuration. Chem Eng Res Des 2003; 81(A4): 448-454. 5. Bouaifi M, Roustan M. Power consumption, mixing time and homogenisation energy in dual-impeller agitated gas-liquid reactors. Chem Eng Process 2001; 40(2): p. 87-95.

116 IJOH July 2013 Vol. 5 No. 3 Karimi et al. 6. Garcia-Ochoa F, Gomez E. Bioreactor scale-up and oxygen transfer rate in microbial processes: An overview. Biotechnol Adv 2009; 27(2): 153-176. 7. Khare AS, Niranjan K. The effect of impeller design on gas hold-up in surfactant containing highly viscous non-newtonian agitated liquids. Chem Eng Process 2002; 27(2): 239-249. 8. Moucha T, Linek V, Prokopova E. Gas hold-up, mixing time and gas-liquid volumetric mass transfer coefficient of various multiple-impeller configurations: Rushton turbine, pitched blade and techmix impeller and their combinations. Chem Eng Sci 2003; 58(9):1839-1846. 9. Dohi N, Matsuda Y, Itano N, Shimizu K, Minekawa K, Kawase Y. Mixing characteristics in slurry stirred tank reactors with multiple impellers. Chem Eng Commun 1999; 171: 211-229. 10. Saravanan K, Patwardhan AW, Joshi JB. Critical impeller speed for solid suspension in gas inducing type mechanically agitated contactors. Can J Chem Eng 1997; 75(4): 664-676. 11. Harvey AD, Wood SP, Leng DE. Experimental and computational study of multiple impeller flows. Chem Eng Sci 1997; 52(9): 1479-1491. 12. Ascanio G, Castro B, Galindo E. Measurement of power consumption in stirred vessels - A review. Chem Eng Res Des 2004; 82(A9): 1282-1290. 13. Arjunwadkar SJ, Saravanan K, Pandit AB, Kulkarni PR. Optimizing the impeller combination for maximum hold-up with minimum power consumption. Biochem Eng J 1998; 1(1): 25-30. 14. Bouaifi MI, Roustan M. Bubble size and mass transfer coefficients in dual-impeller agitated reactors. Can J Chem Eng 1998; 76(3): 390-397. 15. Puthli MS, Rathod VK, Pandit AB. Gas-liquid mass transfer studies with triple impeller system on a laboratory scale bioreactor. Biochem Eng J 2005; 23(1): 25-30. 16. Fujasova M, Linek V, Moucha T. Mass transfer correlations for multiple-impeller gas-liquid contactors. Analysis of the effect of axial dispersion in gas and liquid phases on "local" k (L) a values measured by the dynamic pressure method in individual stages of the vessel. Chem Eng Sci 2007; 62(6): 1650-1669. 17. Chisti MY, Mooyoung M. Hydrodynamics and Oxygen-Transfer in Pneumatic Bioreactor Devices. Biotechnol Bioeng 1988; 31(5): 487-494. 18. Asgharpour M, Mehrnia MR, Mostoufi N. Effect of surface contaminants on oxygen transfer in bubble column reactors. Biochem Eng J 2011; 49(3): 351-360. 19. Shewale SD, Pandit AB. Studies in multiple impeller agitated gas-liquid contactors. Chem Eng Sci 2006; 61(2): 489-504. 20. Zhang LF, Pan QM, Rempel GL. Liquid phase mixing and gas hold-up in a multistage-agitated contactor with co-current upflow of air/viscous fluids. Chem Eng Sci 2006; 61(18): 6189-6198.