Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Similar documents
Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Chemflo ph & ORP Pool Controller

Pool and Spa. Water Testing

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

UsER manual for Watersens ph -REDOX

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

These variables can be accessed by holding the UP button for 5 seconds.

INSTRUCTION BOOK. Simple, Effective ph Control System. Version 1.50a, 02-Nov Please read before you call us for advice. AUTO / OFF PROGRAM / SET

SPECIFICATIONS APCEPH1

Advanced Manual for ChemiGem D10 Water Management System

swimming pool technology

User Manual Chemigem D10 Water Management System

Water Management System User Manual

Instructions for Use

User Manual for Chemigem D10 Water Management System

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

PoolWarden MiniWarden SmarterPool

CCT-7320/ROC-2313 Reverse Osmosis Controller

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products

User Manual AquaFresh Chlorine-Free System

BUBBLER CONTROL SYSTEM

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Pneumatic high-pressure controller Model CPC7000

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Automatic Isokinetic Sampler. ST5 Evo

Quick Installation Guide Doc nr.: C Date:

User Manual for the Gemini System

Semi-Automatic Controllers

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Manual Weighingblock VB2 series and Uniscale

KEG PUMP. Range of Electric Keg Pumps

INSTALLATION AND OPERATING INSTRUCTIONS

Operating Instructions Part No

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

RAM 4021-DPX Operation Manual

Additel 761 Automated Pressure Calibrators

INSTALLATION AND OPERATING INSTRUCTIONS

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

KIV-SACS Safe automatic calibration system:

SAFE. The ChemfloPlus s Smart LCD display shows you the condition of your pool water and what ChemfloPlus is doing about it.

SALT CHLORINATOR RANGE CATALOGUE

INSTALLATION AND OPERATING INSTRUCTIONS

628 Differential Pressure Decay Leak Tester

Additel 761 Automated Pressure Calibrators Selection Guide

EPP4 Pressure Regulator Basic G 1/4"

INSTALLATION AND OPERATING INSTRUCTIONS. Chlorinator

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

RAM 4021 Operation Manual

Additel 761 Automated Pressure Calibrators Selection Guide

Powerline Twin. User Manual for PL Series ph/orp Controller with Saltwater Chlorinator Hayward Twin User Manual - print version inc Plus.

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Additel 761 Automated Pressure Calibrators

Assembly and operating instructions ProCal Calcium hypochlorite system

FAULT CODE TROUBLESHOOTING INDEX

VX Series Salt Chlorinator T Model

G100 RANGE G100, G110, AND G150 OPERATING MANUAL

DIGITAL AUTOMATIC TYRE INFLATOR

VX Series Salt Chlorinator S Model

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

NGP-250/500 Nitrogen Generator Quick Start Guide

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

BUBBLER CONTROL SYSTEM

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

INSTALLATION & OPERATION MANUAL

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

G200 Analyzer Range. Operating Manual

Operating Instructions Part No

Pneumatic high-pressure controller Model CPC7000

RAM Operation Manual

Waste Management System.

Additel 761 Automated Pressure Calibrators

Valve Proving System VDK 200 A S06*

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

ph monitoring of the generated Chlorine Dioxide solution to ensure correct conditions for maximum conversion efficiency

Heavy Duty Dissolved Oxygen Meter

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

PURITY INSTALLATION INSTRUCTIONS MODEL P40

The Univentor 1250 Anaesthesia Unit

Hand-held pressure calibrator with integrated pump Model CPH6600

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

ADT 761 Automated Pressure Calibrator

ACV-10 Automatic Control Valve

G200 RANGE G200 AND G210 OPERATING MANUAL

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

OWNER S MANUAL NMB SERIES

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

CLEANING AUTO CELL OWNERS HANDBOOK

KREEPY KRAULY. Anytime from anywhere on earth. Pool monitoring and control system.

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

SG Series. User Manual for SG Series Saltwater & Mineral Chlorinators

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Instruction Manual Dräger MSI P7 and MSI P7 plus

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Valve Proving System VDK 200 A S02

NIV EAU MATIC ST User Manual Made in Canada

Transcription:

Page 1 of 6 TPS Australia - Quality hand-made instruments since 1968. Nothing's as cool, as a freshwater pool easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump Automatic controller for ORP and ph in Swimming and Spa Pools. The easychem 770 has 2 inbuilt peristaltic pumps, making installation a breeze. Supplied with sensors, calibration standards and all accessories required for installation and operation. Fast and easy to install. Fully waterproof design. Easy to use. Designed for domestic and small commercial pool installations. To see how quick and easy the easychem 770 is to install, ask for a copy of the the installation guide. Full Size Image Illustration of Typical Full Installation Features Pool Pump Timer Output Pump Timer controls the main pool pump. Unit offers Summer, Winter, Auto and Custom modes. Benefits Installer does not have to purchase and install a separate pool timer. Just one power point is required. Saves

Page 2 of 6 Summer mode pumps 4 hours in the morning, 4 hours in the afternoon. Winter mode pumps 4 hours in the afternoon only. Auto mode automatically changes to Winter mode on 15th May and returns to Summer mode on 15th August. (15th November & 15th February respectively for the Northern Hemisphere). These dates can be customised by the user. Custom mode allows user to enter 1 or 2 pumping cycles per day at times of their choice. installation time & money. Ensures controller only adds chemicals when the pump is actually running. Clock has battery back-up so no need to reset in case of power failure. Inbuilt Peristaltic Dosing Pumps Peristaltic pumps are far more reliable than solenoid valves. If a valve on the suction side of a pump leaks when it supposed to be closed, that whole drum of chemical will be dosed into the pool. Peristaltic pumps have positive displacement, so injection can occur in the return line, after the filter and any heating equipment. The benefit of peristaltic pumps is therefore higher reliability and longer life for other pool equipment. Unit is fully calibrated and has most the common set-up defaults when it leaves the factory. Easy Pool Size entry sets up correct automatic control function. Choice of the following settings... Spa 20,000 Litres 50,000 Litres 100,000 Litres Installation is simplified. Just mount the controller and tee piece, connect the probes and switch it on. The default settings are suitable for pools between 50,000 and 100,000 Litres. Saves time. Prevents errors. Unit provides easy control set-up by inputting pool size for other size pools and spas. Single probe and chemical injection tee The single probe mounting and chemical injection assembly is made from a standard 50mm PVC Tee. The installer saves time and money by breaking into the return line at only one point. No special tools or drilling

Page 3 of 6 Reduction bushes are supplied in the kit for 40mm pipe installations. etc are required. Fully waterproof enclosure. The easychem 770 has been independently tested for conformance with IP25 weather resistance. The sensor connectors are IP65 (hose-proof). Makes the easychem 770 suitable for outdoor use without a separate shelter. Reliability is dramatically improved by the use of a completely waterproof enclosure. The superior design of the 24VDC pumps means the entire unit runs cooler than other brands which use 240V AC pumps. 32 character alphanumeric display User-friendly text messages in simple English are provided for control status, alarms, set-up messages etc. No obscure codes or flashing lights which confuse most people. The menu system makes it a breeze to change settings or check operation of the unit. Full function keypad Super-Chlorinate Function Operator can enter how many litres of Chlorine they wish to add. The pool pump is always run for 4 hours when super chlorination is complete, ensuring total mixing. All day-to-day operations are directly accessed with a single keypad button, simplifying operation. More complex set-up tasks are accessed via a separate "Tech Menu" key. End-user or pool service professional does not need to handle liquid chemicals for super-chlorination. The easychem 770 handles it for you, and returns to normal control operation afterwards. Pool Backwashing Function The easychem 770 prompts the user to set the filter control to Backwash, Rinse and Normal Filtration as required. The pool pump is switched off whenever the filter control is being changed. Chemical addition is disabled while backwashing. Makes backwashing simple for home users, helping to ensure clean, hygienic water. Pump to Waste Function

Page 4 of 6 The easychem 770 prompts the user to set the filter control to "Pump to Waste" and Normal Filtration as required. The pool pump is switched off whenever the filter control is being changed. Chemical addition is disabled while pumping to waste. Makes draining the pool simple for home users. Normally only used after periods of heavy rain. Dosing Pump ShutOFF feature If the Chlorine and/or Acid pumps pump chemicals continuously for more than a user-selectable time, the pump (s) will shut down. Stops the pumps operating dry when the chemical drum is empty. Stops whole drums of chemical being added to a pool in case there is an instrument or probe fault. Alarm Function If the ORP and/or ph readings go beyond the Set Point(s) by a preset amount for a preset time, the internal beeper will sound and the display will show an alarm message. The easychem 770 continues automatic control to attempt to bring the reading back within the Set Point. Safeguards against overdosing or underdosing in case of instrument or probe fault. Service/Calibration Interval Message Displays a friendly message at factoryset intervals, informing the user that it's time to check and calibrate the sensors (every 3 months) and lubricate pump tubes (annually). Ensures that the unit is regularly maintained and calibrated, providing for the best possible accuracy and pool water quality. ORP Range : 0 to 999 mv Resolution : 1 mv Accuracy : +/-1 mv Specifications Display 32 Character alphanumeric LCD with user-friendly menu system and fulltext messages. ph Ranges : 2.00 to 12.00 ph Resolution : 0.01 ph Accuracy : +/-0.02 ph Temperature Range : -10.0 to 120.0 O C Resolution : 0.1 O C Accuracy : +/-0.2 O C Temperature Compensation Dimensions 265 x 185 x 130 mm (controller only) Mass Instrument only : Approx 1 kg Full Kit : Approx 5 kg Environment Temperature : 0 to 45 O C Humidity : 0 to 95% R.H.

Page 5 of 6 Automatic Temperature Compensation for ph. Uses temperature sensor built into ORP sensor Calibration Automatic calibration for all parameters, with automatic standards recognition. Enclosure Tough ABS enclosure tested to IP24. Temperature sensor connector is rated to IP65. Peristaltic Pumps 2 x built-in Peristaltic Pump. 1.8L/Hr with small tubes 6.1L/hr with large tubes Chemical resistant Santoprene pump tubing Calendar Clock 24 Hour Calendar Clock. Battery back-up in case of power failure will last for >10 years. Power 220/240V AC, 5 watts max for controller. Can be factory-set for 110/120 V AC Ordering Information Part No easychem 770 Controller...117771 Kit Includes ph Sensor, 2m...111230 ORP/Temp Sensor, 2m...111263 ph7.00 Buffer, 200mL...121387 ph4.00 Buffer, 200mL...121381 231mV ORP Standard...121309 Sensor/Injection Tee...117904 50 to 40mm Bushes x 2...NPBR5040 Pump Suction Tube, 2m x 2...116358 Pump Output Tube, 2m x 2...116360 Drum Lid + tube fittings x2.116362 Tube weights for drum x 2...116354 easychem 770 Handbook...130050 No other items are required to install and operate the easychem 770. Part No Spares Pump Tube assembly, 1.8L/Hr.116353 Pump Tube assembly, 6.1L/Hr.116352 Pump Tube Lubricant, 3mL...130103 Download this Specification Sheet in PDF format. Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer. If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link. TPS reserves the right to change any part of this specification without notice. Version 2.0 Copyright 2002 T.P.S. Pty Ltd

Page 6 of 6 Send mail to tps@tps.com.au with questions or comments about this web site. Web Author : Michael Schimkat Copyright 2002 T.P.S. Pty Ltd Last modified: October 16, 2002