ACID FAST BACTERIA MICROBIOLOGY STAINER / CYTOCENTRIFUGE WESCOR, INC

Similar documents
AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Tissue-Tek Prisma Plus & Tissue-Tek Glas TM g2

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

FAST EVAPORATION AT NORMAL PRESSURE

Imagine... full flexibility linked to high capacity. Tissue-Tek Prisma & Film. Automated Slide Stainer & Coverslipper

Series Environmental Chambers

250 ton mt Lattice Crawler Crane

Imagine... full flexibility linked to high capacity

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

NovelBright LED Illuminator

WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling

Offering more. Series

Basic & Controlled Atmosphere Glove Boxes

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

The Next Generation. Pulse Duplicator HDT-500. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

Transferpette. Lightweight precise rugged reliable!

Screw Compressors 11-22kW

Transferpette. Lightweight precise rugged reliable!

Tradition & Technology

tel: fax: web:

SuperClear 15mL and 50mL Centrifuge Tubes

High Pressure Asher HPA-S

The All New DIAMOND & DIAMOND BT

Instruction Manual Updated 7/26/2011 Ver. 2.2

Your local gas generation partner. Precision series Modular gas generation solution for GC.

DIAGNOSTIC CARDIOLOGY

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

BACTRON Anaerobic Chambers The Complete Environmental Microbiology Workstation Anaerobic, Hypoxic, & other Gas Environments

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Shandon Cytospin 4 Cytocentrifuge

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Traysealer T 100. Tray packaging in the smallest space

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

Pneumatic high-pressure controller Model CPC7000

829S1 Series Flexflo Pilot

High-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Pneumatic high-pressure controller Model CPC7000

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

Chlorinator MODEL MK-I

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

MARITIME PROTECTION NITROGEN SYSTEM

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

BS ml Bottle Sampling Unit

UTEX INDUSTRIES, INC.

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

Unit shown in luffer configuration

Emergency Transport and Ventilation

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Protec P3000 (XL) Helium Sniffer Leak Detector

INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Heavy-duty power for the most demanding jobs

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

KAYDON RING & SEAL, INC.

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

Unisys. Imagine it. Done. c Consulting. c Systems Integration. c Outsourcing. c Infrastructure. c Server Technology. Unisys NDP 30 and NDP 110

Your local gas generation partner. Precision series Modular gas generation solution for GC.

An intuitive and innovative answer to your anaesthesia challenges

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

Precision Rotary Airlocks and Diverter Valves

HumiSys HF High Flow RH Generator

InFlow Modular perfusion bioreactor

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Air screwdrivers CSEZ

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

TTS-800 GOLF ROTORS. Best-in-Class Irrigation Solutions for Every Course. GOLF IRRIGATION Built on Innovation. hunterindustries.

CAPITAL CONTROLS SERIES NXT3000

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

KMT Waterjet Systems Inc.

VACUUM REGULATORS CONTENTS

WORKHOLDING APPLICATION BOOKLET

Powermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650

Hospital and Transport for Controlled Breathing

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Air Amplifiers & SYSTEMS

THE GOAT AND SHEEP RANGE

OPERATION OF THE DIMPLER

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Transcription:

ACID FAST BACTERIA STAINER / CYTOCENTRIFUGE MICROBIOLOGY WESCOR, INC

he Newest Innovation Is Here! AFB Staining has never been so easy, fast, or economical The Aerospray Microbiology Acid-Fast Bacteria (AFB) Slide Stainer/Cytocentrifuge provides significant advantages over hand staining or automated dip-type stainers, including speed, economy, consistent performance, and no cross-contamination. The new Aerospray AFB stainer performs either carbol fuchsin or fluorescence procedures by exchanging reagents and selecting the appropriate program on the keyboard. This unique device provides two essential instruments in one economical package. With Wescor s optional Cytopro rotor, the Aerospray stainer becomes a superb cytocentrifuge featuring 8- slide capacity and keyboard programmability. All at a fraction of the cost of a stand alone cytocentrifuge! Aerospray, Cytopro, and Cytopad are trademarks of Wescor, Inc. U.S. Patent Numbers 4,004,550; 4,089,989; 5,009,185; 5,252,228.

Economical The Aerospray is exceptionally sparing in reagent consumption, giving you versatile full or partial load programming options that significantly reduce reagent volumes and costs required for staining different sized loads. An optional 30 slide carousel brings high volume economy within reach of every laboratory. Rapid Performance With a cycle time as short as 4.5 minutes, the Aerospray stainer can process more than 150 slides per hour (up to 400 with the optional 30- slide carousel). No more waiting for slides to dry they re ready to view when the staining cycle ends. Easy to Use Simply select from 6 different stain settings and start the staining cycle. That s all you have to do because the stainer takes over from there, precisely controlling all phases of the stain cycle with consistent reproducibility. Carbol Fuchsin or Fluorescence Staining on Demand With a few keystrokes and a change of reagents the AFB stainer can be configured for Kinyoun, Ziehl-Neelsen, auramine or auramine/rhodamine staining methods. No Cross Contamination In all Aerospray stainers, fresh reagent is applied as an atomized spray on slides mounted in a rotating carousel. Specimens contact only fresh, precisely metered stain from separate spray nozzles. No cross-contamination is possible. Optional Rotor for Cytocentrifugation For the cost of the optional Cytopro rotor, the Aerospray stainer becomes a superb cytocentrifuge with 8 slide capacity and keyboard programmability at a fraction of the cost of purchasing a stand-alone cytocentrifuge.

Ready for the Microscope in Minutes

The Wescor AFB Staining Process A erospray stains microscope slides smeared with materials containing acid-fast microorganisms such as culture materials, body fluids, or exudates. Wescor reagents are tailored to give superb results in the Aerospray stainer. The Aerospray stainer provides a choice of staining cycles ranging from 1 to 6, allowing you to compensate for thick specimens, or other possible variables. Fixation Specimens are heat fixed according to traditional procedures prior to staining in the Aerospray. Primary Stain At the beginning of the staining cycle, the slides are sprayed with the primary stain (carbol fuchsin or fluorochrome) that penetrates and stains the specimens. Excess stain is then spun off and washed away with deionized water to prevent precipitate formation. Decolorizing Acid alcohol decolorizer is then applied to remove the primary stain from the non acid-fast bacteria and surrounding debris. The decolorization is stopped with a water wash and a short spin. Counterstain The counterstain is then applied to stain the non-acidfast organisms. Excess counterstain is then removed with a water wash and a short spin. Drying The slides are spun at about 950 RPM for 45 seconds. This draws air through the machine and dries the slides. Slides emerge from the stainer dry and ready for the microscope. With its rapid staining cycle and high throughput capability, the Aerospray stainer is a convenient, cost effective way to stain mycobacteria.

CYTOPRO Cytocentrifuge Rotor

W With the optional Cytopro rotor, the Aerospray stainer becomes a cytocentrifuge at a fraction of the cost of a stand alone cytocentrifuge. There s no modification or fiddling involved. Simply remove the staining carousel and replace it with the Cytopro rotor. The self-contained sealed rotor loads easily in a biological safety cabinet. The rotor and sample chambers are autoclavable. Sample chambers are competitively priced so you can economically dispose of them. THE CYTOPRO CHAMBER The chamber s unique design combines ease of use with superb cell recovery. -Perfect Alignment. The Cytopad absorption pad snaps quickly between the chamber and the frame. This guarantees that the chamber bore is always correctly aligned. No fumbling, and no cell loss due to poor alignment. -Better Flow Control. Each Cytopad features a specially compressed ring around the center hole. This compression controls fluid flow and improves the repeatability of fluid absorption. -Dual Sample Port. Two ports, one in the sample well and one in the tunnel allows you to introduce prewetting fluids to increase cell recovery. -Chamber Caps. You can load samples directly through the chamber caps to prevent spilling of hazardous samples. -Two Fluid Absorption Rates. The white Cytopad is for faster absorption of viscous or debrisfilled suspension fluids. The tan pad is used to slow fluid absorption for improved cell recovery in non viscous fluids such as urine or CSF. EASY TO ASSEMBLE AND LOAD Assembling the Cytopro chamber is easy; chambers and Cytopads fit securely together with foolproof precision. No more cell loss due to misaligned filter cards. You ll be surprised how simply chambers and slides load into the rotor. The ends of each slide are fully visible to you for accurate patient identification. The rotor bowl s shallow profile makes sample loading more convenient than with a deep rotor. Simply pipette sample fluid directly into the sample well (maximum sample size: 0.5 ml) or through vents in the chamber caps. The semi-transparent sample chambers allow visual confirmation of correct sample volume. THE CHOICE IS YOURS Cytopro delivers the versatility you need to satisfy a wide variety of sample treating requirements: - Unparalleled ease of use - Simple and flexible programming - Superior sample chamber design - Choice of two fluid absorption rates - Convenient prewetting capability - Safety and reliability Finally, you have the flexibility to control the cytocentrifugation process and to set the level of convenience. The choice is yours. Caution! Due to the hazards of airborne mycobacteria, samples must be inactivated before processing in the Cytopro or any other cytocentrifuge.

Instrument Specifications Aerospray Microbiology Acid-Fast Bacteria Slide Stainer/Cytocentrifuge Model 7720 Slide Carousel Capacity Carousel Rotation Speed Cytocentrifuge Rotor Speed Display Touch Pad Controls 12 or 30 slides Reagent application 20 RPM, slide drying approximately 950 RPM Programmable, 100 to 2000 RPM 4 line by 16 character alpha-numeric LCD dot-matrix 6 staining selections, 10 Numeric Programming Keys, Run Stop, Clean, Prog, CytoCent, Volume Test Reagent Consumption Ranges from 0.7 to 4.0 ml. Medium settings will use 1 to 2 (combined, excluding water) ml per slide Operating Time 3.7 to 10.6 minutes depending on system and settings Dimensions (W x H x D) 56 cm x 24 cm x 53 cm (22 x 9.5 x 21 ) Clearance Height (lid open) 58 cm (23 ) Weight Electrical Requirements Drain Connection Safety 17.6 kg (39 lb) 100V, 120V, 220V or 240V (user-selectable) @ 50 to 60 Hz, 75 watts Nipple on rear panel Lid interlock: Lid must be closed, and is locked down during operation. Cytopro Cytocentrifuge Rotor Cat. No. AC - 060 Capacity Weight 8 chambers and slides 1.3 kg (2.8 lb) Dimensions (Dia. x H) 23 cm x 4.8 cm (9.0 x 1.875 ) For information regarding Aerospray automatic stainers contact: WESCOR, INC 459 South Main Street, Logan, Utah 84321 USA TELPHONE: 800 453 2725 435 752 6011 FAX: 435 752 4127 E-MAIL: sales@wescor.com COPYRIGHT WESCOR, INC 1998 PRINTED USA NOV 98 577-1 PB18A48