SHOP WELDED TANKS STANDARD CONNECTIONS

Similar documents
PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

Application Worksheet

OIL AND GAS SEPARATION DESIGN MANUAL

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips

OIL AND GAS PROCESSES AND EMISSIONS

Pipe-Away Pressure Vacuum Vent /Conservation Vent

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

Efficient Pigging of Gathering Lines. Energy Management Workshop for Upstream and Midstream Operations

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Air Eliminators and Combination Air Eliminators Strainers

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Horizontal Bladder Tanks

Vertical Bladder Tanks

North American Orifice Metering System

APPENDIX C TANK BATTERIES

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

OPERATING INSTRUCTIONS

Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

CURI Pierside Stainless Diesel Tank

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Fundamentals Of Petroleum Engineering PRODUCTION

Chapter 13 Gases, Vapors, Liquids, and Solids

VERTICAL BLADDER TANK

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Natural Gas Conditioning Skids & Equipments

HORIZONTAL BLADDER TANK

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation

Model 1800 PFM Series Regulator. Technical Bulletin

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

At the end of this lesson, you will be able to do the following:

Tank Blanketing Pressure Regulators RHPS Series

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Facilities Design Shift Horizontal Equipment in Oklahoma Scott King

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN

Compressed Gases and Cryogens

Vortex Tube Short Course February 2017

SIZING AND CAPACITIES OF GAS PIPING

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

PRODUCT GUIDE Spring 2015

FV Flash Vessel Installation and Maintenance Instructions

GAS DEHYDRATION SYSTEM

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

REFRIGERATION SYSTEM COMPONENTS

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

GAS DEHYDRATION SYSTEM

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Pressure Systems Safety Regulation

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SIZING AND CAPACITIES OF GAS PIPING

North American 7337A/B/C-4 High Pressure Gas Regulators

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

ASSIGNMENT 2 CHE 3473

Simplicity in VRU by using a Beam Gas Compressor

Digester Processes. 1. Raw Sludge Pumping System

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR SELECTION, Corresponding IS does not exist

Use equation for the cylindrical section and equation or for the ends.

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

ASSIGNMENT 2 CHE 3473

TECHNICAL DATA. Q= Cv S

Yutaek Seo. Subsea Engineering

GAS DEHYDRATION SYSTEM

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

SECTION DIGESTER GAS SAFETY AND CONTROL EQUIPMENT

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

S300 Series. Valve Link. Features. Fisher Controls

Energy Specialties International

Type ACE95jr Tank Blanketing Valve

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Tank Blanketing. Application Jordan Valve Product Offering Competition

ENGINEERING FLUID MECHANICS

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

DISTILLATION POINTS TO REMEMBER

MAINTENANCE AND OPERATING MANUAL

Best Practices for Installation of Gaseous Sample Pumps

ETHOS Environmental and Thermal Operating Systems (ETHOS)

TECHNICAL DATA. Q = C v P S

Self-operated Pressure Regulators for special applications

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Series 8500 Expansion Compensators. Catalog 674H

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada

Transcription:

STEEL WELDED TANKS Tanks are constructed using 3/16 and ¼ inch A36 material. Welding and testing are performed according to API 12F specifications. Shop welded tanks are also available in special sizes and can be constructed to API 650, UL 142, and American Water Works Association specifications. Tanks are primed and painted to customer preference. A variety of protective corrosion control coatings can also be provided. We do offer a variety of tank Thief Hatches for specific customer applications by manufacturers such as Vessel Components, Enardo, Jayco and more. Tank pressure ratings per API 12-F for 12 foot diameter are 16 OZ. 15'6" diameter are rated at 8 OZ. Our Longview TX plant offers API 12 F Monogram tanks when required by customer. Coating for external and internal can be customized per application. 33

SHOP WELDED TANKS STANDARD ACCESSORIES 1-24 X 36 EXTENDED NECK CLEANOUT 1-PRESSURE / VACUUM THIEF HATCH 7-THREADED CONNECTIONS 1-DOUBLE SET OF WALKWAY LUGS 1-COAT PRIMER & ENAMEL PAINT OPTIONAL ITEMS 1-FLANGED OR GROOVED CONNECTIONS 1-LARGER AND OR ADDITIONAL CONNECTIONS 1-ROLLING LINES 1-DOWNCOMERS 1-PROTECTIVE COATINGS 1-CUSTOM EXTERIOR PAINT STANDARD CONNECTIONS DESCRIPTION 210 BBL & UNDER 250 BBL & OVER VENT CONNECTION 3 4 FILL CONNECTIONS 3 4 OVERFLOW CONNECTIONS 4 4 PIPELINE CONNECTION 4 4 DRAIN CONNECTION 3 4 GAUGING FORMULA: DIAMETER X DIAMETER X.14 = BBL PER Ft. CAPACITY BBLS DIMINSIONS W X H SHIPPING WEIGHT Lbs. 100 9 6 X 8 3,430 100 8 X 12 2,825 200 12 X 10 5,390 210 10 X 15 5,410 250 11 X 15 6,100 300 12 X 15 6,820 400 12 X 20 8,300 500 12 X 25 9,745 500 15 6 X 16 10,500 34

GUNBARREL TANKS The gunbarrel is a low maintenance atmospheric settling vessel, it provides an economical method in which to treat oil. Most commonly used downstream of a heater treater or separator, production will enter the flume at the top of the vessel. Solution gas released at this point is vented to storage. The oil and water fall downward through the downcomer pipe and contact a spreader table. Free water falls to the bottom section and exits through a waterleg. The large settling section will allow entrained water to coalesce to form larger droplets that gravity flow to the bottom section and combine with the free water. The clean oil at the top of the settling section will spill over the oil outlet and gravity flow to storage. The gunbarrel will not treat emulsions, the oil and water must both be free liquids also the vessel must be tall enough for the oil and water to gravity flow to storage. 35

GUNBARRELS STANDARD ACCESSORIES 1-THIEF HATCH 3-SET 48 SIGHT GLASS WITH GAUGE COCKS 1-INTERNAL FLUME 1-FLANGED GAS BOOT 1-SPREADER TABLE 1-BASE BLOCK WITH 4 & 6 Ft DIAMETER 1-COAT PRIMER AND ENAMEL PAINT INLET VENT GAS BOOT OPTIONAL ACCESSORIES 1-CUSTOM EXTERIOR PAINT 1-PROTECTIVE COATINGS OIL OUTLET FLUME 1-FLANGED OR GROOVED CONNECTION 1- LARGER FLUME & SPREADER TABLE SIZE HEIGHT FROM BTM TO OIL OUTLET INLET VENT DECK EQUL. OIL & WATER OUTLETS MANWAY 4X20 18 2 2 2 3 16 Dia 6X20 18 3 2 2 3 16 Dia 8X20 18 3 2 2 3 24 X 36 10X20 18 4 4 4 4 24 X 36 10X25 23 4 4 4 4 24 X 36 12X20 18 4 4 4 4 24 X 36 12X25 23 4 4 4 4 24 X 36 SPREADER TABLE GAS WATER OIL WATER OUTLET MANWAY DRAIN RETENTION TIME (Hrs.) = 24 X SETTLING VOLUME BBLS. / DAY WATERLEG HEIGHT = (Wh X SG) + (Oh X SG) Water SG 36

Coatings Standard Coatings Global Vessel and Tank offers our customer a wide variety of coating options, however our standard coating is a Exterior DTM Polyurethane Epoxy by Devoe offered in a variety of common industry colors. In the event of our customers wanting an Internal Coating our standard coating is Sherwin Williams Nova Plate UHS. These above combinations have a proven track record in the industry. Coating Options As our customers may require special coatings Global Vessel and Tank can accommodate those needs. Our offering includes but is not limited to the following manufacturers; Devoe Sherwin Williams Carboline Enviroline Corchem PPG Custom coatings are typically performed by our 3rd party providers. We can offer both exterior and Internal coatings to meet our customers exact coating specifications. Customer coatings do require more lead time and are done at an additional cost. Custom coatings by our 3rd party providers do carry a full 1 year warranty against manufacturers defects. Subject to inspection. 37

DEFINITIONS ABSORBER TOWER A tower that provides contact between natural gas being processed and a liquid or solid desiccant. ABSORPTION The operation in which one or more components in a gas stream are absorbed into a desiccant. ATMOSPHERIC PRESSURE The pressure exerted on the earth by the earth s atmosphere. A pressure of 14.7 psia is used as a standard. BTU An abbreviation for British Thermal Unit. One BTU is the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit. The heating value of a fuel is measured in BTUs. CONDENSATE The liquid formed by the condensation of a vapor or gas, specifically the hydrocarbon separated from natural gas due to changes in pressure and temperature when the gas is produced from the reservoir. DEHYDRATION The process of removing water from gases or liquids. DESICCANT A substance or material used to remove water and moisture. DEW POINT The temperature at any given pressure, or the pressure at any given temperature, at which liquid initially condenses from a gas or vapor. DEW POINT DEPRESSION The difference between the original dew point temperature of a gas and its dew point temperature after dehydration. DRY GAS Gas whose water content has been reduced by dehydration. GAS-OIL RATIO The ratio of gas to oil produced from a well. GAS PROCESSING The separation of constituents from natural gas for the purpose of making salable products and also for treating the residue gas to meet required specifications. HEAT EXCHANGER A jacket which surrounds a casing or machine element in order to remove, add, or distribute heat in order to control the temperature within a vessel or element. HYDRATE A solid material resulting from the combination of a hydrocarbon with water under pressure. JOULE-THOMSON EFFECT The change in gas temperature, which occurs when the gas is expanded at constant enthalpy from a higher pressure to a lower pressure. The effect for most gases at normal pressure is a cooling of the gas. MCF An abbreviation for one thousand cubic feet of gas. 38

MMCF The abbreviation for one million cubic feet of gas. NATURAL GAS Gaseous form of petroleum. Consisting predominately of mixtures of hydrocarbon gases. The most common component is methane. PACKED TOWER A absorption column or tower filled with packing designed to give contact between rising gas and a descending liquid. PIPELINE GAS Gas which meets a transmission company s minimum specifications. RELIEF SYSTEM The system for safely relieving excess pressure to avoid exceeding equipment design pressure. STANDARD CUBIC FEET Gas volume at standard temperature and pressure. SOLUTION GAS Gas which originates from the liquid phase in an oil reservoir. SPECIFIC GRAVITY The ratio of the mass of a given volume of a substance to that of another equal volume of another substance used as a standard. Air is used as the standard for gas and water for liquids, with the volumes measured at 60 degrees Fahrenheit and atmospheric pressure. TRAYED TOWER A vessel wherein gas and liquid are contacted, usually countercurrent on trays. WET GAS A gas containing water, or a gas that has not been dehydrated 39