Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

Similar documents
INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Our technical information is based on Tip: calls attention to special information.

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Fisher DVI Desuperheater Venturi Inline

INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

MANUAL BE SERIES Test Benches

TROUBLESHOOTING GUIDELINES

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

DBML-60/80 Squeeze Tool

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

6900 Maintenance Instruction System Flush

The Discussion of this exercise covers the following points:

WATER TREATMENT SYSTEM OPERATION MANUAL

LNG Regulator Test Kit

MB-SP Series Solvent Purification System

User Instruction Manual

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Lesson 6: Flow Control Valves

OPERATION AND MAINTENANCE MANUAL

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

INSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS

1020 Industrial Drive, Orlinda, TN fax

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

OPERATING MANUAL LO-CROSS-FLOW CF M

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Adjustable. Unloader Valve. O&M Manual. Part #

Air Eliminators and Combination Air Eliminators Strainers

SINGER MODEL 106/206-RPS-L&H

INSTALLATION and OPERATION INSTRUCTIONS

User Manual for the Mars Calibration Bench

Irrigation System Winterization and Pressurization Procedures

Rejuvenation Instructions

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Operation, Assembly & Maintenance Manual

Hydro-Mech Bridge Plug

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Flow Material Length. Weight GPM LPM. Style 3095

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

POLYURETHANE SPRAY FOAM REFILL SYSTEM QUICK START GUIDE

User's Manual. MixRite TF 10. Edition 05.08

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Bladder Tank Installation & System Design Information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Chemical Injection Technologies Installation/Service Bulletin

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

BACK PRESSURE / SUSTAINING

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Operation Manual Piston Sensed Gas Pressure Regulators

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

BACK PRESSURE / SUSTAINING

Cover Page for Lab Report Group Portion. Head Losses in Pipes

VERTICAL BLADDER TANK

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

HORIZONTAL BLADDER TANK

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Installation, operating and maintenance Instructions for Seemag bypass level indicator

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

The Discussion of this exercise covers the following points:

Model PSI Compressor with 3-Gallon Air Tank 12VDC

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

OPERATING AND MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

ABRASIVE REGULATOR II

OPERATION MANUAL NTF-15

6800 Maintenance Instruction System Flush Procedure

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Macro-Infusion Guide

NTF-230 OPERATION MANUAL

Subsea Safety Systems

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Genie Supreme Model 123 Installation & Operation Instructions

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Technical Information

TECHNICAL INFORMATION

PRODUCT INFORMATIONAL BULLETIN

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Operating Instructions

DB Bridge Plug. Features. Benefits. Applications

PRO SINK -R 1 and 2. Dilution system CONTENTS

Pressure Compensating (PC) Spray Stakes

APPS-160 Gen 2 User Manual

POWER FLUSH KIT INSTRUCTIONS

Installation Instructions

Transcription:

TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before attaching a tank or other storage device to the irrigation system, make sure the tank is capable of safely containing the pressure of the irrigation system. EZ-FLO assumes no responsibilty for failures of tanks that are not manufactured by EZ-FLO. FOR ASSISTANCE VISIT OUR WEBSITE AT www.ezflofertilizing.com CALL TOLL FREE 1-866-393-601, EZ-FLO Fertilizing Systems 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

TABLE OF CONTENTS SYSTEM COMPONENTS 1-2 CONNECTION OPTIONS 3-4 CONNECTING THE SYSTEM INJECTING WATER SOLUBLE PRODUCTS 6 INJECTING LIQUID PRODUCTS 7 SETTING THE INJECTION RATE 8 CALCULATING THE INJECTION RATE 9- BY-PASS OPERATION 11 FILLING THE TANK 12 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com

TM SYSTEM COMPONENTS Tank Overview Fill Valve Water Supply (WS) Liquid or Dry Products Diversion Valves (not pictured see page 4) Fertilizer / Product Return Shut Off Valve Injection Metering Gauge Bypass Valve Bypass Line Fertilizer / Product (FR) Return Line Water Supply Line Purge (PV) and Drain Valve Fertilizer / Product (FR) Return Line Water Supply (WS) Line Figure 1 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 1

SYSTEM COMPONENTS Head Assembly Cam-Lock Quick Disconnect Product / Fertilizer Fill Valve (LP) Liquid Product Water Supply Valve Product / Fertilizer Out Valve Open Retention Clips (WSP) Water Soluble Product Water Supply Valve Fertilizer / Product Out Connection Injection Metering Valve Water In Connection Figure 2 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 2

Connection Options The EZ-FLO Hi-FLO system may be installed using the engineered Saddle Venturi Connection (SVF) or a prefabricated coupling connector. If utilizing the SVF connection, please contact an EZ-FLO representative to insure proper considerations for pressure and flow have been identified. Saddle Venturi Connection (SVF) Step 1 - Drill (2) - 1 1/4 holes a minimum of 6 apart, in the irrigation main line near the installation location of the EZ-FLO System. Make sure there is enough room for the saddles to attach snugly to the pipe. Hole Saw or Reaming bit is recommended. CAUTION: DRILL SLOWLY TO PREVENT PIPE FRACTURE Drill 2-1 1/4 Holes Pump Station Or Water Source #1 #2 X X Irrigation Mainline Flow Direction To Irrigation System Step 2 - Attach saddle to pipe. The blue connection should be installed in the first drilled hole in the irrigation main line with the venturi probe opening facing into the water flow. The green connection should be installed in the second drilled hole in the irrigation main line with the venturi probe opening facing away from the water flow. Green Connection (Injection Return) COMPLETED SADDLE ASSEMBLY Blue Connection (Water Supply) Optional Valve Location Flow Direction Figure 3 Note: A butterfly or ball valve may be required for low flow irrigation mainline to allow for throttling. This will increase the differential pressure necessary to operate the system. Contact an EZ-FLO representative for more details and calculations. 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 3

HIGH FLO COUPLING (HFC) Step 1 - Cut out appropriate section of pipe by measuring the socket depth of the connector and the overall length as shown in figure 4. Due to variations in the fabrication process it is highly recommended each fitting be measured before installation to insure proper spacing. Measure Overall Length 3.8" C After measuring, use the simple formula of: A + B - C= Cut Out Length Note: You may also use a slip fix or unino to facilitate easier installation. 0.4" 0.1" Measure Socket A Figure 4 Measure Socket B CUT OUT SECTION Irrigation Mainline Step 2 - Use standard solvent cementing techniques to install the HFC connection into the PVC main lin. Irrigation Mainline Flow Direction Note: The HFC connection includes a ball valve for throttling. This may be required for low flow irrigation mainline to allow for throttling. This will increase the differential pressure necessary to operate the system. Contact an EZ-FLO representative for more details and calculations. 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 4

TM To connect the system to the irrigation line FR WS Step 1 - Familiarize yourself with the various connection points and valves on the EZ-FLO injection system. Make sure all valves are in the closed position before proceeding. Step 2 - Connect tubing to the system and to the irrigation line. Connect the water supply WS tubing to the water supply connection on the irrigation main line and tank mixing head. Connect the fertilizer return FR tubing to the fertilizer return connection on the tank metering head and the irrigation main line as shown in figure. The connections are color coded or labeled for easy reference. Secure all tubing connections using the provide tubing clamps. Do not over tighten clamps or stress tubing barbs. Step 3 - Fill with water through the top fill valve. Step 4 - Once full, turn all the water supply valves to the on position to pressurize and check for leaks. Tighten any leaking parts before proceeding. Figure 7 displays various valves on the head in the on position. The metering valve and the (Optional) shut off valves from the irrigation mainline connection must also be open to supply pressure to the tank. * All HF systems are pressurized at the factory to 12 psi but items may shift or loosen during handling and transport FR PV WS To Pressureize Flow SVF Installation Shown Close Fill Valve Open LP Water Supply Valve. Figure Open Product / Fertilizer Out Valve Step - Shut off all valves and open the bottom purge valve (PV) to depressurized and drain the tank. After the purge valve is opened, open the fill valve for additional venting assisting in the draining of the system. Open WSP Water Supply Valve Step 6- Close bottom purge valve (PV) before adding product to the tank. Metering Valve On Figure 7 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page

Injecting Water Soluble Powder The EZ-FLO system has the ability to inject Water Soluble Powder products (WSP), Liquid Products (LP), or a combination of both. To change between LP and WSP products, the appropriate valve must be opened. In figure 8 below, the system is configured to deliver WSP products or product requiring heavy agitation. This setting continually agitates the solution allowing for very high concentrations of product to be placed in the system without the concern of plugging. Step 1- Open the WSP Water In Valve as shown in figure 8. The valve is in the open position when the handle is in line with the valve body and piping. Step 2- Close the LP Water In valve as show in figure 8. The valve is in the closed position when the handle is not in line with the valve body and piping. Step 3- Open the Product / Fertilizer out valve as shown in figure 8. Product / Fertilizer Out Valve Open WSP Water In Valve Open LP Water In Valve Closed Step 4- Open the two shut off valves in the mainline to allow water flow into the system and product to flow out. Step - Set injection metering gauge to the desired injection rate. Figure 8 if the gauge is already set, it does not need to be adjusted at time of refill. If switching to LP from WSP, the system will inject the product on average twice as fast. This is a direct result of the LP already in suspension not requiring dissolving before injection. Reference Page 11 for Setting The Injection Meter 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 6

Injecting Liquid Products The EZ-FLO has the ability to inject Water Soluble Powder products (WSP), Liquid Products (LP), or a combination of both. To change between LP and WSP products, the appropriate valve must be opened. In figure 9 below, the system is configured to deliver LP products or product that does not require mixing or agitation. This setting diverts all incoming water to a special port in the top of the tank to maximize layering of the solution to prevent dilution of the solution. Step 1- Open the LP Water In Valve as shown in figure 9. The valve is in the open position when the handle is in line with the valve body and piping. LP Water In Valve Closed Step 2- Close the WSP Water In valve as show in figure 9. The valve is in the closed position when the handle is not inline with the valve body and piping. Product / Fertilizer Out Valve Open Step 3- Open the Product / Fertilizer out valve as shown in figure 9. Step 4- Open the two shut off valves in the mainline to allow water flow into the system and product to flow out. Step - Set injection metering gauge to the desired injection rate. WSP Water In Valve Open Figure 9 if the gauge is already set, it does not need to be adjusted at time of refill. If switching to WSP from LP, the system will inject the product on average at half the speed. This is a direct result of the WSP requiring dissolving before injection. Reference Page 11 for Setting The Injection Meter for additional information. 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 7

Setting the Injection Rate Note: On the initial fill, the tank will stretch and expand for the first few minutes. When the tank has fully expanded the tank pressure will equalize with the line pressure and the feed rate can be set. Step 1- Insure the irrigation mainline is pressurized Step 2- Open all appropriate incoming and outgoing valves Step 3- Slowly open the injection metering valve by turning the valve knob to the left. The gauge will register the amount of water entering the tank until it is completely pressurized. Wait for the meter to drop to zero before setting the feed rate. CAUTION: Not all valve models retain the knob and can become dislodged from the housing if opened too far. As a rule, 8 full revolutions of the knob will generally allow for it to be removed from the valve. Injection Metering Valve Step 4- Turn the irrigation system and run a zone that is the average flow rate Step - Rotate the knob on the metering valve to the left until the desired gallons per hour or gallons per minute is achieved. Note: If the gauge will not reach the desired injection rate you may need to calibrate your connection (Figure -1) or by-pass valve (Page 11) Calibration Procedure: Valve Knob Figure Step 1- Irrigation system is on and running but metering gauge is not able to inject fast enough Irrigation Mainline Connection No Adjustment Irrigation Mainline Connection Valve Throttled Step 2- Confirm the by pass valve is in the full closed position Step 3- Slowly close the valve on the HFC (Page 4) connection or in between the SVF ( Page 3) saddles until injection rate is attained. Flow Direction Figure -1 Flow Direction Step 4- Adjust gauge as needed to control injection rates Once the gauge is set, the system will automatically adjust to pressure and flow changes and there is typically no need to make additional adjustments to the gauge. Note: The gauge is very sensitive and bouncing of the float is normal. This is caused by momentary fluctuations in pressure or flow from the mainline. The gauge will quickly return to the set position after each fluctuation. 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 8

Calculating the Injection Meter Setting Setting the system is as simple as A-B-C: A- Know your tank capacity B- Know your irrigation total run time C- Know how many cycles you want to run before the product runs out ( 2 to 3 cycles is recommended) This creates the EZ formula of (A / B) / C Injection Metering Valve Step 1- Know your tank capacity (A) HF-04 4 gallons (LP) 40 pounds (WSP) HF-086 86 gallons (LP) 860 pounds (WSP) EZ-FLO manufactures the two models above but does offer custom sizes as well. Typically you only have to reference one of the above sizes for calculating the feed setting. Step 2- Know your irrigation run time (B) The system injection rate is set based on gallons per hour and knowing the total hours of irrigation run time will tell you how long the system will last at each setting. As a general rule, longer irrigation run times typically result in lower feed rate setting to insure the products are not completely dispensed before the end of the cycle. Valve Knob Figure 11 Step 3- Know how many irrigation cycles you want the system to run before dispensing all of the product (C) The typical recommendation for various products is a minimum of 2 to 3 complete irrigation cycles. You may run the system faster or slower depending on the product or landscape needs. However, EZ-FLO advises the 2-3 cycle window to achieve even coverage. Step 4- Put the above together and figure out your desired gauge setting. EZ Equation: Tank Capacity / Irrigation Run Time = hours to empty Example: HF-04 = 4 gallon tank and irrigation run time of 4 hours and 3 days of running until empty. EZ Calculation: 4 gal / 4 hours = 11.2 hours until empty, then 11.2 / 3 days or running = 3.7 GPH injection setting. The above tells us to set the gauge at 3.7 GPH to empty the tank contents in 3 days or 3 complete cycles. Using the same figures above, but now you want the tank to last 1 day or irrigation cycle, then you would do the following: EZ Calculation: 4 gal / 4 hours = 11.2 hours until empty, then 11.2 / 1 day of running = 11.2 GPH injection setting If you are to do the calculation once again, but using a 2 day watering window, the math would change as follows: EZ Calculation: 4 gal / 4 hours = 11.2 hours until empty, then 11.2 / 2 days or running =.62 GPH injection setting. Continued on Next Page 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 9

Calculating the Injection Meter Setting (Cont.) Injection Metering Valve Step - Additional considerations need to be taken into account after selecting the desired feed rate. It is fine to round up injection rates a full half or gallon per hour. A good example is to use the above of.62, this can be rounded to 6 GPH and not cause any issue with the results. The majority of injectable products do not require the accuracy people tend to attempt. Generally a to % differential is acceptable. Allow an extra day of run time to fully clear any dyes or residual products from the tank. If you are planning to run the system for a 2 day cycle, plan to drain and refill after 3 cycles to allow for a full purge cycle. All products are not created equal and will differ in solubility and viscosity. This may affect the ability for the system to inject the products. Typically, we do not encounter products that cannot be injected, however the rate may be slower than anticipated. Injection of WSP versus LP: Valve Knob Water Soluble Products (WSP) and Liquid Products (LP) have a very distinct difference in that the WSP is not in a readily injectable form. The WSP must first dissolve into a liquid before it can leave the injector Figure 11 where as a LP will immediately leave the injector. If pre dissolving a WSP or adding less than 3 lbs per gallon of total tank capacity, the product should be treated as a liquid per the below chart: HF-04 4 Gallon Liquid Capacity up to 13 Lbs Water Soluble Powder is still treated as a liquid HF-086 86 Gallon Liquid Capacity up to Lbs Water Soluble Powder is still treated as a liquid LP injects at a 1 to 1 rate, which means for every gallon of incoming water measured by the injection meter, 1 gallon of product will leave the tank. On an HF-04 system, after 4 gallons of water have passed through the injection meter, the tank will be empty of product. WSP must dissolve and the rates will vary. The amounts of WSP added to the tank can vary greatly as well. Once above the levels listed above, you can use the ratio of 2 lbs of WSP will leave the tank for every gallon of incoming water measured by the injection meter. Example: HF-04 with 40 lbs of WSP will take 22 gallons of incoming water to empty the tank EZ Calculation: 40 lbs / 2 lbs per gallon of incoming water = 22 gallons TO figure back to the gauge setting, you can use the 22 gallons as your new tank capacity. EZ Calculation: 22 gallon capacity / 4 hours of irrigation run time = 6.2 / irrigation cycles = 11.2 GPH gauge setting If you have any questions regarding the above, please call toll free: 866-393-601 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page

TM EZ-FLO By-Pass Operation Typically the EZ-FLO HI-FLO systems will operate perfectly fine without the use of a bypass / venturi relief valve, but if you are injecting into flow streams above 10 GPM the valve may be required. To properly calibrate and adjust: 1.) Make sure the tank is completely filled (fluid or supplement) so no air is present. By-Pass a. Purging the ½ tubing lines is not necessary as all air will Valve evacuate automatically Closed 2.) Start with the by-pass valve in the full closed position a. Allow the irrigation system to reach maximum flow b. The bypass valve and flow meter cannot effectively be configured at flow ranges below the maximum flow rate 3.) Once the mainline is operating at full flow set the flow meter to the desired feed rate a. Do not adjust the bypass yet, it should still be in the full closed position 4.) Observe the flow meter float and its ability to maintain the set level for a period of 2 to 3 minutes. a. The float will bounce due to fluctuations in pressure but quickly Figure 12 recover to the selected setting, this is normal operation. b. Continue to observe and confirm the float is returning to the appropriate level and not steadily dropping.) If the float continues to return to the appropriate level and the irrigation system is operating at full flow, no adjustment needs to be made to the bypass valve. 6.) While observing, if the float fails to return to the appropriate level and steadily to lower levels the bypass valve will need to be opened a. When the float steadily drops, increase the observation time to minutes to insure it does not recover 7.) To adjust the bypass valve, simply turn the valve to the full open position. a. This will instantly relive the turbulence in the venturi fitting 8.) Once in the full open position, set the injection meter to the desired feed rate and observe for minutes.) Now the flow meter may be set to the desired level of injection The bypass valve is now configured and if the bypass valve is ever accidentally adjusted the above steps may be repeated. Special notations: If the bypass valve is too far open, the system will lose the ability to inject at higher rates. Depending on the desired level of injection, this may not be an issue. When the bypass valve is too far closed, the injection may suddenly stop. By-Pass Valve Open Figure 12-1 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 11

TM To Fill The Tank with Product The EZ-FLO HI-FLO system may be filled with virtually any liquid (LP) or water soluble product (WSP) in full concentrated form. No premixing or dilution is required although it may be applicable in high coverage rate products. Water soluble products may be easier to pour into the tank if premixed into a slurry or flow-able paste. Fertilizer Out Valve Closed Fill Valve Open Water Supply Valve Closed Tank Capacities: HF-04 4 Gallons (LP) 40 Pounds (WSP) HF-086 86 Gallons (LP) 860 Pounds (WSP) Step 1- Confirm all valves are closed and the tank is empty or enough fluid has been removed to allow for the addition of the new product. If filling to maximum capacity all fluid should be drained through the purge valve (Figure 13) Do not close or adjust the injection metering valve, this will unnecessarily change your injection rate. Step 2- Open the fill valve and attach the High Capacity Funnel (HFC, Optional) (Figure 13-1) Step 3- Add the desired amount of products (Figure 13-1) Step 4- Top off with water and close the fill valve (Figure 13-2) Figure 13 Purge Valve Closed Do not leave air in the tank, this will delay injection and may cause damage to the system and it components. FERTI-MAXX HYDRO-MAXX Fertilizer Out Valve Closed HCF Fill Valve Open Water Supply Valve Closed Fertilizer Out Valve Open Fill Valve Closed Water Supply Valve Open Figure 13-1 Do Not Adjust Metering Valve Figure 13-2 Note: The system will always have 1 quart to 1/2 gallon of dyed material or residual product at the time of draining. This is due to the location of the dip tube assembly and materials sitting in the drain. The product may be saved and added to the next batch without issue. 17, EZ-FLO Fertilizing Systems Phone (866) 393-601 Fax (916) 62-74 www.ezflofertilizing.com Page 12