Humberside Fire and Rescue Service

Similar documents
Unit 3: Fire Service Operations and Incident Command International

Safety management The Firefighter Safety Maxim Risk assessment at an incident Tactical mode Emergency evacuation and tactical withdrawal

Cobra Cold Cut System

Instructions for the Use of the Excel Spreadsheet. There are Three tabs at the bottom of this worksheet. Instructions tab is the one you are reading

HAZARDOUS INCIDENT SITE SAFETY PLAN

Air management Working in pressurised atmospheres Withdrawal of breathing apparatus wearers Communications...

TACTICAL VENTILATION Graeme Bowser, Tyne & Wear Fire Brigade, U.K.

Confined Spaces. This procedure applies to all workers of the Diocese of Maitland Newcastle (DoMN).

Exercise IARD. Risk Assessment & Management Plan

Lone Working Guidance for University Departments and Functions December 2009 Safety Services Office

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS

University College Dublin Machinery/Equipment Risk Assessment Template

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

The Airfield Volunteer Fire Service

Emergency Response Plans

Appendix C Health and Safety Guidelines for investigators

Component Specification NFQ Level TBC

CONSTRUCTSAFE TIER 1 HEALTH AND SAFETY COMPETENCY TEST FRAMEWORK

FACULTY OF EDUCATION LOW RISK HEALTH AND SAFETY FORM FORM B

Iowa s s Minimum Training Standard. How to Be Prepared?

Recognition, Evaluation, and Control of Hazards

Key Technology, Inc. Confined Space Entry Program. July, 2017

3. PURPOSE: To establish the minimum safety content of swimming pool Operations Manuals.

Bogo Operations Pollution Incident Response Management Plan

Module: Permit to work System

Examiner s Report March 2013

IFE Level 3 Diploma in Fire Safety and Fire Science. Unit 6 Fire Service Operations and Incident Command

Rapid Intervention for Engine Companies. LA County Fire Department

Committee Input No. 35-NFPA [ Chapter 1 ] Submitter Information Verification. Committee Statement

The Marlie Farm Explosion

75 Years of Health and Safety Guidance

Firefighter Job Description Norwich Fire Department

Accidents and accident prevention

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Conducting An Effective. Welcome!

Chapter 5. Response Tactics and Strategies Delmar, Cengage Learning

POLICY FOR COSHH (CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH) POLICY

Health and Safety Policy

RISK MANAGEMENT. Siobhan Mulvenna, GIOSH, FCIPD

Safety: blah, blah, blah, yawn, yawn, zzzzzzz

University risk assessment form and guidance notes. Oct 06

Occupational Health & Safety

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

IFE Level 3 Diploma in Fire Science and Fire Safety

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

unable to summon help as a result of injury, ill health or an emergency. unable to carry out a task safely while alone.

PART 4: IMPLEMENTATION & OP

INTRODUCTION UNIFIED COMMAND

IFE Level 3 Diploma in Fire Science and Fire Safety

Risk assessment. Assessment details. Task. Introduction. Please complete the form as fully and accurately as you can. Assessors job title

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

Two phases have been established for the classification of incidents to help in determining the appropriate course of action;

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

Job Hazard Analysis (JHA) What is Job Hazard Analysis (JHA)?

Before you begin. Introduction Implement and monitor work health and safety procedures 1

Health and Safety Program Inspections

Safe Work Method Statement LRB TREE SERVICES 6 Behland St, Kearneys Spring QLD, 4350 ABN

TABLE OF CONTENTS PART 11 - FIREFIGHTING

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

IIUM EVENT SAFETY RISK ASSESSMENT

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

The CITY OF BURNSVILLE Invites applications for the position of: Firefighter/Paramedic. An Equal Opportunity Employer

RISK ASSESSMENT AND HAZARD CONTROL

Confined Space Entry Appendix - Sewerage Transfer. 1. Purpose Sewerage Transfer Assets. 2. Scope. 3. Procedure

HAZARD RECOGNITION EVALUATION and CONTROL

Safe Working On Roads Standard Operating Procedures

BHC-P-07.2 Health Hazards in Construction

Safety Management System. Initial Revision Date: Version Revision No. 02 GENERAL SAFETY HEALTH PROVISION

Confined Space. A Death Trap in Waiting. Technical Article

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

LONE WORKING HEALTH AND SAFETY GUIDANCE

Western Sydney University Safety Inspection Checklist - Laboratory Environments

Ionising Radiations Code of Practice & Guidance Contingency Arrangements

CHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES

Approved for public release; distribution is unlimited.

Safe Work Method Statement

WIND TURBINES. STANDARD OPERATING PROCEDURE S.O.P. No. Version 1.0

WHS CONTRACTOR INFORMATION PACKAGE

Request for permission to work on a public sewer S106 (part 2 application form) 2018/19

HAZARD RECOGNITION EVALUATION & CONTROL. Procedure No. HR-405-PR-2 Division Human Resources. Supersedes n/a Board Policy Ref.

Series Confined Space Rescue - Draft Page 1 of 6 Adopted: Revised: INCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL

Orchard Farm Fire Protection District Standard Operating Procedure

Hampstead Hill School Health and Safety Policy: Confined Spaces

Guidelines for Rapid Extraction in a Hazardous Materials Environment

Company Policy Health & safety for work performed at Customer premises

Health & Safety Contractor rules

CONFINED SPACE ENTRY

Accident Investigation and Hazard Analysis

OPERATIONAL GUIDELINE P R O C E D U R E

Idaho Fire Service Technology Fire Fighter II

EUSCS04 Overseeing work in confined spaces

RISK ASSESSMENT A UNIVERSITY GUIDE TO PRACTICAL RISK ASSESSMENT UNDER THE MANAGEMENT OF HEALTH AND SAFETY AT WORK REGULATIONS 1992

To comply with the OHS Act, the responsible manager must carry out and document the following:

Waste Industry Safety & Health

Policy Redesign Project. Plant Safety Policy. Table of Contents

North Carolina Fire and Rescue Commission Live Fire Audit Form

Transcription:

Introduction & Range Humberside Fire and Rescue Service Generic Risk Assessment Control Measures STANDARD OPERATING PROCEDURES FOR Aide-Memoir Fighting fires in High Rise Buildings S.O.P. No. 3.2 PRODUCED BY: OPERATIONAL SUPPORT SERVICE HEADQUARTERS SOP 3.2 Page 0 November 2007-0 -

HUMBERSIDE FIRE & RESCUE SERVICE STANDARD OPERATING PROCEDURES OPERATIONAL PROCEDURE DETAILS DESCRIPTION SOP No. REVIEW Fighting fires in High Rise Buildings 3.2 Issue Date : November 2007 WM 088 Review Date: November 2010 OPERATING ENVIRONMENT 1. Incident ground - Fires and special services 2. Training venues - On and off station venues INTRODUCTION RISK ASSESSMENT The Service has a duty to make a suitable and sufficient assessment of the health and safety risk to employees and others who may be affected by their actions and to provide employees with comprehensive and relevant information on risks identified. This assessment identifies the hazards, risks and controls that relate to incidents involving High Rise Buildings HOW TO USE THIS STANDARD OPERATING PROCEDURE This document has been designed to be read easily, quickly and with only ESSENTIAL information included. The following pages contain the information that all operational personnel MUST know. The cover of this procedure has on it four coloured boxes, each relating to a specific section. Simply identify the section you want to look at then turn to the appropriate coloured heading(s). This information about High Rise Buildings is available to personnel in the following form: Operational Aide-Memoire (carried on appliances and by FDS officers) Appliance Mobile Data Terminals The Intranet (via Library Documents Standard Operating Procedures ) SOP 3.2 Page 1 November 2007

RANGE OF DOCUMENT Firefighters attending incidents involving high rise buildings will generally be involved with fires and special services at multi storey buildings such as domestic dwellings, hospitals, hotels, industrial and commercial premises. Therefore this procedure should be read in conjunction with: Fire Service Manual Volume 2, Fire Service Operations Incident Command Technical Bulletin 1/1997, Breathing Apparatus Command and Control Procedures Service Orders 10 - Health & Safety - Risk Assessment Arrangements, Dynamic Risk Assessment SOP No. 2.2 Rescues from lifts and escalators SOP No. 3.6 Ventilation SOP No. 5.8 Flashover/backdraught For Fire Service purposes, a high rise building may be considered as one which contains floors at a height that external rescue and firefighting are not feasible. Due to limited access for aerial appliances, many buildings of 5 floors and over will be classed as high rise. The basic design principle is based on sub-division and compartmentation. Provided any communicating openings are sealed, the size, development and spread of fire will be limited. Personnel involved in firefighting may have to climb a number of staircases before reaching the scene of operations. Falling Objects Lightweight forms of construction cannot be expected to have as high a degree of fire resistance as the more substantial brick and concrete forms. Many forms of curtain walling are pre-fabricated in sections which are later 'hung' on the framework of the building. This introduces a potential weakness from the fire aspect. Debris from the site may present a significant hazard in that even a small piece of the structure falling will accelerate to its terminal velocity and can travel some distance away from the building. Glass, in particular large sheets of glass from curtain walling and windows, may 'plane' a considerable distance. In addition, falling debris may be ejected explosively from the fire. The Effects of Wind High rise buildings cause complicated wind patterns to build up, especially between high blocks, slab blocks and low buildings, with the result that a small breeze can be magnified and channelled into fast-moving eddies and currents, by the resistance of the buildings to the air flow. The wind can cause fire to spread some considerable distance, even spreading to floors that are separated. SOP 3.2 Page 2 November 2007

GENERIC HAZARDS BRIEF DESCRIPTION OF ACTIVITIES OR TASKS TO BE ASSESSED HAZARD CHECKLIST L* S* R* 1. Fall of person from height 2. Fall of object or material from height M H H 3. Fall of person on same level (slip or trip) 4. Manual handling H M H 5. Machinery hazards (cuts, abrasions, entanglement, friction) 6. Operation of vehicles 7. Fire M H H 8. Electricity 9. Drowning 10. Excavation work (where this is part of the task) 11. Stored energy 12. Explosions (chemicals or dust) 13. Contact with excessively hot or cold surfaces 14. Compressed air or gases 15. Mechanical lifting operations 16. Noise 17. Biological agents 18. Radiation Non-Ionising 19. Radiation-Ionising 20. Excessive vibration 21. Use of hand tools 22. Adverse weather conditions (where exposure is part of the task) 23. Hazardous Substances 24. Storage, stacking or shelving 25. Housekeeping 26. Lighting levels (too high, too low, glare, rapid changes) 27. Confined spaces 28. Cleaning (before, during or after the task) 29. Use of display screen equipment (as part of the task) 30. Lone or unaccompanied working 31. Exposure to personal violence or aggression 32. Flashover/backdraught L H M This is the first part of the Risk assessment. When considering the hazards at this stage you must mentally remove the controls that are in place, as it is easy to consider that a task is of low likelihood or severity because the risk is already being controlled. The danger of this is that this incidental control may not be appreciated and may be removed by changing operators. Hazards with a risk rating of HIGH or MEDIUM are considered to be significant findings and require transferring onto the risk assessment record, to be re-assessed taking into account persons at risk and control measures put into place. If no significant findings are identified i.e. all hazards have a risk rating of LOW the risk assessment need proceed no further and the record kept for reference purposes. SOP 3.2 Page 3 November 2007-3 -

No ACTIVITY High Rise Buildings HAZARD 2 Fall of object or material from height 4 Manual Handling PERSONS AT RISK A, D, E A, D 7 Fire A, D, E 32 Flashover/ backdraught A, D, E GENERIC RISK ASSESSMENT EQUIPMENT LOCATION: REF No. 3.2 CONTROL MEASURES Cordon off hazard area. Identify hazard area with cordon tape. Prevent access to hazard area. All personnel to receive information, instruction and training fighting fires in high rise buildings. Appoint safety officers to watch for falling debris. PPE. Assess route to be travelled, avoid slip and trip hazards. Use fixed installation if available. Reduce weight to be carried by individuals. Information, instruction and training in manual handling techniques. Have charged hose ready to use before entering compartment. Consider use of correct door opening techniques. PPE, BA, leave no skin exposed. Minimum number of personnel in risk area. Training, pre planning, exercises, instruction and information on firefighting in high rise buildings. Establish hazard zone. Use fixed installations if available. Follow correct backdraught/flashover procedures. PPE, BA, leave no skin exposed. Information, instruction and training in signs and symptoms of flashover/backdraught. SOP 3.2 Page 4 November 2007 RISK ESTIMATE L x S RISK RATING ADDITIONAL CONTROLS REQ. Y/N L H M N M L L N L M L N L M L N PERSONS AT RISK CODE ASSESSMENT DATE A OPERATIONAL PERSONNEL D OTHER AGENCIES PERSONNEL REVIEW DATE B CONTROL PERSONNEL E MEMBERS OF THE PUBLIC ASSESSORS NAME RANK No. C NON-UNIFORMED PERSONNEL F YOUNG PERSONS

Likelihood LIKELIHOOD SEVERITY HIGH Expected HIGH - Fatality/disabling injury MEDIUM Possible it will happen sometime MEDIUM A period of absence with full recovery LOW Improbable (rarely/never) LOW Minor injury allowing people to stay at work RISK ESTIMATOR Severity HIGH MEDIUM LOW HIGH HIGH HIGH MEDIUM MEDIUM HIGH MEDIUM LOW LOW MEDIUM LOW LOW RISK RATING LOW MEDIUM HIGH NO ADDITIONAL CONTROLS REQUIRED, CONSIDERATION MAY BE GIVEN TO A MORE COST EFFECTIVE SOLUTION OR IMPROVEMENT THAT IMPOSES NO ADDITIONAL COST BURDEN. MONITOR TO ENSURE THAT CONTROLS ARE MAINTAINED. EFFORTS SHOULD BE MADE TO REDUCE THE RISK, BUT COSTS OF PREVENTION SHOULD BE CAREFULLY MEASURED AND LIMITED. RISK REDUCTION METHODS INCLUDE SAFE SYSTEMS OF WORK, INFORMATION, INSTRUCTION, TRAINING, SUPERVISION, PPE. WORK SHOULD NOT BE STARTED OR CONTINUED UNTIL THE RISK HAS BEEN REDUCED USING THE HIERARCHY OF CONTROL MEASURES SUCH AS ELIMINATION, SUBSTITUTION, ISOLATION, REDUCTION ETC. IF IT IS NOT POSSIBLE TO REDUCE THE RISK EVEN WITH UNLIMITED RESOURCES, WORK HAS TO REMAIN PROHIBITED. SOP 3.2 Page 5 November 2007

CONTROL MEASURES TRAINING All personnel should be given information, instruction and training relating to the hazards presented by high rise buildings and should therefore undertake a regular programme of training sessions and exercises at high rise premises in their station area. Consider developing exercises to simulate worst case scenarios i.e. communications failure, lift failure, Fire Service personnel shut in lift due to mechanical failure, defective dry riser or premises pump failure. Clearly identify the minimum equipment required for dealing with high rise incidents and the most effective method of moving/transporting this equipment to the bridgehead. Training should allow crews to rehearse the safe systems of work described below and should adhere with the principles of operational training. Further relevant information can be found in: Educational materials provided by the Learning and Development Section. Fire Service Manual Volume 2-Fire Service Operations-Compartment Fires and Tactical Ventilation. PRE-PLANNING Regular inspections and familiarisation visits of all high rise buildings in the station area should be carried out. Points of interest will be: Name of premises. Approach roads. Access for appliances. Rendezvous points. Access to buildings. Fire alarm annunciator panels and zone plans. Floor numbering. Compartment numbering. Locations of keys for access to hose reels, dry risers, pump rooms, firefighters switch. Location of lift and lift motor rooms, lift controls and firefighters switch. Fixed installations. Dry riser inlets and drain valves, Hose reel isolation valves. Protected staircases, landings and lobby areas. Isolation switches. Location of hydrants. Any particular hazard e.g. complicated layout, security doors, and occupants. Any fixed installation communication equipment. The information gained will afford the Incident Commander a degree of accuracy when carrying out a dynamic / analytical risk assessment during the initial stages of the incident. Control should be informed if engineers, specialist information and / or key holders are required for each premises. SOP 3.2 Page 6 November 2007

DYNAMIC RISK ASSESSMENT The Incident Commander should carry out a comprehensive Dynamic / Analytical Risk Assessment and adequately brief crews prior to deployment. However, a continuous risk assessment must also be carried out by all personnel on the incident ground. The following should be considered as part of the Dynamic Risk Assessment process: The height of the floor involved. Nature and size of the fire. Water supplies. The need to start up BA in fresh air. Resources available to implement safe system of work. Safety of personnel ahead of bridgehead. Rescues. Evacuation. Local knowledge. OPERATIONAL CONSIDERATIONS Initial Actions If there is a firefighter s switch fitted to the lifts, take control of all the lifts and have them stationed at ground level. If the lifts are suitable they may be used by Fire Service personnel Some lifts may only stop at alternative floors. If there is no firefighters switch the lifts should not be used but called to the ground floor and made inoperable e.g. the doors wedged open. The Incident Commander should ensure that all personnel are informed that the lifts are not to be used. If the premises has a dry riser locate riser inlet box and nearest hydrant. Provide water supplies from the hydrant to riser via the appliance pump. If there is no dry riser, implement locally established plan to provide water to the fire floor. Establish a suitable BA Entry Control Point location at ground level. Provide 2 BA wearers with appropriate equipment. After assessing all available information, the Incident Commander will identify an appropriate floor to establish a Forward Control Point. A Bridgehead must be established at least two floors below the fire floor. BA wearers are to start up their sets confirm communications with the ECO and proceed to the floor identified as a bridgehead by the Incident Commander. If lifts are inoperable or there is no firefighters switch, the bridgehead and BAECP will be established using the staircase by two personnel in BA, but not under air, and the ECO with communications to the Incident Commander. SOP 3.2 Page 7 November 2007

On arrival at the identified floor: Confirm communications. Assess suitability of floor for use as a Forward Control Point, if floor is unsuitable, proceed to the floor below and reassess. Forward Command Point and BAECP are to be established on the identified floor. Inform the Incident Commander via the ECO. The Incident Commander should ensure all personnel are kept up to date. Conduct a DRA and if assessed as safe to do so, prepare fire fighting equipment and commence firefighting operations. Second appliance in attendance Report to Incident Commander; if a third pump is not in attendance; assist in providing water supplies as required. The OIC of second appliance, 2 BA wearers, a lift operator and the ECO should proceed to Forward Control Point. As the Incident Develops As the incident develops, Analytical Risk Assessments must be produced. The Incident Commander must ensure that all personnel on the incident ground are aware of the hazards. When handing over command of the incident, the officers involved must ensure an effective briefing takes place. The Incident Commander will take charge of all operations at ground level and ensure that no unauthorised persons gain access to the risk area at the incident by establishing and maintaining an appropriately sited cordon. Ensure the utility services are isolated to the affected compartment. A reconnaissance of all sides of the building should be conducted and the OIC of Forward Control Point informed of any relevant information. The lift operator should return to the ground level to transport any additional personnel and equipment resources required on to the identified floor. Third appliance in attendance Report to Incident Commander at the ground floor level Control Point. Assist in providing water supplies as required. Provide additional equipment (if required) to the Forward Control Point Assist in the control of movement of personnel and other agencies entering risk area Provide 2 BA wearers at the Forward Control Point. Further actions as directed by the Incident Commander. Other Considerations PPV post fire. Assess floors above the fire floor for smoke logging. Individual compartments may remain smoke free if the doors to the compartment are kept shut. The Incident Commander should consider leaving the occupants in place. Occupants should be questioned about the situation inside their compartments. If occupants are to be left in their compartments regular checks must be made on their welfare. If it is considered that the safety of occupants is or could be compromised they must be evacuated. SOP 3.2 Page 8 November 2007

A fire involving the first four floors may be treated as a Low Rise property if ladder access can be achieved. The Forward Control Point and the ground floor level Control Point must have an identified individual in charge at all times. If the Officer in Charge of the second appliance attending is of a more senior role to that of the initial Incident Commander the most senior officer will assume command and remain at ground floor level. All subsequent attending resources Report to the ground floor level Control Point for deployment/briefing instructions. All personnel committed to firefighting and rescue operations to report to Forward Control Point for briefing as to allocated task. Post Incident Consider Community Fire Safety advice for neighbouring properties. All equipment used will require standard testing and the test recording. Complete and forward Analytical Risk Assessment forms to the Operational Support Section. Conduct a Post Incident Debrief and forward a Post Incident Review for any significant findings to the Operational Support Section. SOP 3.2 Page 9 November 2007

INITIAL ACTIONS RISK ASSESSMENT AIDE MEMOIR Access Nature and size of the fire Water supplies Safe systems of work Safety of personnel ahead of bridgehead Rescues Evacuation Local knowledge The height of the floor involved. Contained to one compartment or spreading to other floors or compartments. Dry riser, hydrant, hose reels or no fixed installation. Bridgehead at least two floors below fire floor. IC to remain at ground floor, OiC of second appliance to be at FCP. Casualty handling, casualty carer. Lead other occupants to safest exit route. Appliance positioning, access points, fixed installations, annunciator panels etc. Firefighters switch No firefighters switch Dry riser Entry Control Point BA Wearers Proceeding to bridgehead Lifts inoperable or No firefighters switch On arrival at bridgehead Communications Assess floor for FCP Inform IC of location Of bridgehead Take control of all the lifts by operating firefighter switch. Do not use the lift, call to the ground, make inoperable e.g. wedge doors open. If the premises has a dry riser, connect to nearest hydrant via the appliance pump. If there is no dry riser implement locally established plan to provide water to the fire floor. Establish a suitable BA Entry Control Point location at ground level. Provide 2 BA wearers with appropriate equipment. The Incident Commander will identify an appropriate floor for a Forward Control Point. A Bridgehead must be established at least two floors below the fire floor. BA wearers to start up, confirm communications with the ECO, proceed to the bridgehead. Bridgehead and BAECP established using the staircase by two personnel in BA, not under air and the ECO with communications to the Incident Commander. Confirm communications. Assess suitability of floor for use as a FCP, if floor is unsuitable, proceed to the floor below and reassess. FCP and BAECP are to be established on the identified floor. Inform the Incident Commander via the ECO. Conduct a DRA and if assessed as safe to do so, prepare fire fighting equipment and commence firefighting operations. DRA, commence task Second appliance in attendance Report to Incident Commander; assist in providing water supplies as required. OIC of second appliance, 2 BA Wearers, the lift operator and the ECO should proceed to the FCP. SOP 3.2 Page 10 November 2007

POST INCIDENT OTHER CONSIDERATIONS AS INCIDENT DEVELOPS Analytical Risk Assessments Analytical Risk Assessments must be produced. Ensure that all personnel on the incident ground are aware of the hazards. The Incident Commander The lift operator The Incident Commander will take charge of all operations at ground level. Ensure the utility services are isolate to the affect compartment. Examine all sides of the building. The lift operator should return to ground level to transport any additional resources. Third appliance in attendance Report to Incident Commander. Assist in providing water supplies as required. Provide additional equipment (if required) to the Forward Control Point Provide 2 BA wearers at the FCP. Further actions as directed by the Incident Commander. PPV Evacuation OiC of second of appliance PPV post fire. Assess floors above the fire floor for smoke logging. Individual compartments may remain smoke free. Consider leaving the occupants in place. Conduct regular checks on their welfare. If the safety of occupants is or could be compromised they must be evacuated. If the Officer in Charge of the second appliance attending is of a more senior role to that of the initial Incident Commander, the most senior officer will assume command and remain at ground floor level. Community fire safety Equipment Analytical Risk Assessment Post Incident Debrief Consider Community Fire Safety advice for neighbouring properties. All equipment used will require standard testing and the test recording. Complete and forward Analytical Risk Assessment forms to the Operational Support Section. Conduct a Post Incident Debrief and forward a Post Incident Review for any significant findings to the Operational Support Section. SOP 3.2 Page 11 November 2007