FUJI ELECTRIC CATALOGUE 2017
CONTENTS OVERVIEWS About Us 3 Fuji Electrical Gas Analysis 4 Support for Fuji Electric Gas Analysis Products 4 Emissions Monitoring - CEMS 5 Conversion Factors 6 PRODUCT INFORMATION ZPA / ZPB / ZPG Multi-Gas Analysers 7 ZRJ / ZRE / ZKJ Multi-Gas Analyers 9 ZPAF Biomass Gas Analysers 11 ZSS / ZSS Dual In-Situ Gas Analysers 13 ZAF / ZAFE Thermal Conductivity Gas Analysers 15 ZFK7 Zirconia Oxygen Analyser 17 ZKM ZFK8 Zirconia Oxygen Probes 18 ZKM ZTA Zirconia Oxygen Probes 20 ZKME ZKFE Zirconia Oxygen Probes 22 ZSV Portable Multi-Gas Analyser 24 2
ABOUT US ABOUT US DRM offers products and services for combustion, process and environmental monitoring. We make our own products and also represent leading manufacturers. We are a leading gas analysis and conditioning equipment supplier whose services include system design/installation and product maintenance/support. We ve worked within the measurement industry for many years and work very closely with most of the leading UK and European systems integrators and manufacturers. We have excellent relationships with our customers and endeavour to always provide high quality solutions with the best possible price/performance ratios. EASY WAYS TO PAY We accept cheques, credit/debit cards and electronic bank payments. We are an established exporter and are pleased to offer a complete export service for our large product range. We can export our products worldwide. CONTACT DETAILS Address: DRM Technic, 4 Cherry Orchard, Newcastle-under-Lyme, Staffordshire, ST5 2UB, UK Telephone: +44 (0)1782 638491 Email: sales@drmtechnic.com 3
FUJI ELECTRIC Fuji Electric are one of the leading gas analyser manufacturers worldwide. Established in 1923 and with an annual turnover of over 2 billion (April 2014), Fuji invest heavily in product development and have manufacturing plants around the world. Accrediation for Fuji Analysers SIRA MC130224/00 CEMS certified to: EN15267/EN14181 Their analysers are manufactured in Japan with full European support being provided by FEF (Fuji Electric France; based in Clarmont- Ferrand). Fuji Electric s main activities include: - Gas Analysers - Pressure Transmitters - Flowmeters - Industrial Recorders - Temperature and Process Regulators - Temperature Transmitters - Inverters SUPPORT FOR FUJI ANALYSERS UK/EIRE DRM Technic Ltd are the exclusive distributors for Fuji Gas Analysers in the UK and Eire. DRM Technic and Fuji support our Analysers with: - Factory Trained Sales People - Factory Trained Service Engineers - Spare Parts / Consumables Stock On-Site at DRM - On-Site Workshops for Analyser Repairs 4
CEMS: ATMSOPHERIC EMISSIONS MONITORING DRM offers analysers for emissions and process monitoring. Emissions monitoring is required for the reporting of gas emissions to the local authority/ Environmental Agency and is usually a provision of the operating permit. Gas Components required for Emissions Monitoring: CO - NOx - SO2 - O2 - NH3 - HCl - H2O - N20 - CO2 Other Measurements that may be Required: Flue Gas Flow Rate Flue Gas Pressure Flue Gas Temperature Dust Concentration Monitoring Certification Requirements: CE requirements only or CEMs certified to EN15267 / EN14181 CEMS: ATMSOPHERIC EMISSIONS MONITORING - SYSTEMS EXAMPLE 5
CONVERSION FACTORS FOR GAS ANALYSIS SOURCE TESTING ASSOCIATION Recommended CONVERTING EMISSION CONCENTRATIONS Ng/Nm³ C CH₄ CO CO₂ HCl HF Hg NH₃ NO NO₂ SO₂ Factor x ppm 0.530 0.716 1.250 1.965 1.628 0.893 8.955 0.760 1.340 2.054 2.860 OXYGEN CORRECTION EQUATION MOISTURE CORRECTION EQUATION CONVERSION OF PPM TO MG/M³ Factors reported at 237K and 101.3 kpa PRESSURE 750 mm Hg = 101.325 kpa = 29.92 in Hg 1.0 mm Hg = 13.6 mm H₂O 1.0 mm H₂O = 9.81 Pa 6
ZPA/ZPB/ZPG MULTI-GAS ANALYSERS Fuji ZPA, ZPB and ZPG analysers are high quality analysers which can measure up to 5 separate gases at once. They can measure NO, SO₂, CO, CO₂, CH₄ and O₂ gases. ZPA is the general use model, ZPB the high performance model and ZPG the ultra low concentration model. For the gas ranges that each analyser can detect, please see overleaf. FEATURES - Simultaneous Measurement of up to 5 gases (4 Infrared Gases plus Oxygen) - Excellent Long Term Stability - Fast Response Times - Compact Size and Simple Operation - Ultra-low Measurement Capabilities - Maintenance Reducing Unique Measurement Cell - Oxygen Measurement Options: - Fuel Cell - Internal Paramagnetic - External Zirconia - Easy to Read LCD Display with Easy to Use Menu SPECIFICATIONS ZPA ZPB ZPG Mounting 19 Rack 19 Rack 19 Rack Repeatability +/- 0.5% FS +/- 0.5% FS +/- 0.5% FS Drift +/- 2.0% week (zero/span) +/- 2.0% week (zero/span) +/- 2.0% week (zero/span) Flowrate 0.5 l/min (+/- 0.2) 1.0 l/min (+/- 0.2) 0.5 l/min (+/- 0.2) Inlet/Outlet 1/4 NPT (Female) 1/4 NPT (Female) 1/4 NPT (Female) Display 4 digit backlit LCD 4 digit backlit LCD 4 digit backlit LCD Analogue Out 4-20mA DC or 0-1 V DC 4-20mA DC or 0-1 V DC 4-20mA DC or 0-1 V DC Power Supply 100 to 240V AC 50/60Hz 100 to 240V AC 50/60Hz 100 to 240V AC 50/60Hz Consumption Approx. 100VA Approx. 120VA Approx. 100VA Dimensions 483 x 133 x 382 mm 483 x 133 x 382 mm 483 x 133 x 382 mm 7
ZPA / ZPB / ZPG SPECIFICATIONS Model Method Details Gases and Ranges ZPA Single Beam General Use Model (up to 5 gases), ideal for: Heat Treatment Small Incinerator Fruit Storage Combustion Control Emissions Monitoring NO: 0-200 / 5000ppm SO₂: 0-200ppm / 10% CO: 0-200ppm / 10% CO₂: 0-100ppm / 100% CH₄: 0-500ppm / 100% O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% ZPB Single Beam High Performance Model (up to 4 gases), ideal for: Combustion Control Crematoria Control Oxidiser Monitoring Wood Boilers Emissions Monitoring NO: 0-50 / 5000ppm SO₂: 0-50 / 5000ppm CO: 0-50 / 5000ppm CO₂: 0-150ppm / 25% O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% ZPG Dual Beam Low Concentration Model (up to 5 gases), ideal for: Air Seperation Plants Gas Manufacturing NO: 0-10 / 100ppm SO₂: 0-10 / 100ppm CO: 0-5 / 50ppm CO₂: 0-5 / 50ppm O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% EXCELLENT STABILITY ZPA uses a new cell design which minimises zero drift down to 0.5% full scale per week. ZPB/ZPG analysers utilise a unique cell arrangement where the analyser is self checking the zero drift constantly, meaning that they have no zero drift. 8
ZRJ/ZRE/ZKJ MULTI-GAS ANALYSERS Fuji ZRJ, ZRE and ZKJ multi-gas analysers are high quality analysers which can measure up to 5 separate gases at once. They can measure NO, SO₂, CO, CO₂, CH₄ and O₂ gases. ZRJ is the general use model, ZRE the high performance model and ZKJ the low concentration model. For the gas ranges that each analyser can detect, please see overleaf. FEATURES - Simultaneous Measurement of up to 5 Gases (4 Infrared Gases plus Oxygen) - Excellent Long Term Stability - Fast Response Times - Compact Size and Simple Operation - MCERTs and TuV Approval - Oxygen Measurement Options: - Fuel Cell - Internal Paramagnetic - External Zirconia - Easy to Read LCD Display with Easy to Use Menu SPECIFICATIONS ZRJ ZRE ZKJ Mounting 19 Rack 19 Rack 19 Rack Repeatability +/- 0.5% FS +/- 0.5% FS +/- 0.5% FS Drift +/- 2.0% week (zero/span) +/- 2.0% week (zero/span) +/- 2.0% week (zero/span) Flowrate 0.5 l/min (+/- 0.2) 0.5 l/min (+/- 0.2) 0.5 l/min (+/- 0.2) Inlet/Outlet 1/4 NPT (Female) 1/4 NPT (Female) 1/4 NPT (Female) Display 4 digit backlit LCD 4 digit backlit LCD 4 digit backlit LCD Analogue Out 4-20mA DC or 0-1 V DC 4-20mA DC or 0-1 V DC 4-20mA DC or 0-1 V DC Power Supply 100 to 240V AC 50/60Hz 100 to 240V AC 50/60Hz 100 to 240V AC 50/60Hz Consumption Approx. 100VA Approx. 100VA Approx. 100VA Dimensions 483 x 177 x 493 mm 483 x 133 x 418 mm 483 x 177 x 690 mm 9
ZRJ / ZRE / ZKJ SPECIFICATIONS Model Method Details Gases and Ranges ZRJ Single Beam General Use Model (up to 4 gases), ideal for: Heat Treatment Small Incinerator Fruit Storage Combustion Control Crematoria Control Emissions Monitoring NO: 0-500 / 5000ppm SO₂: 0-500 / 5000ppm CO: 0-20ppm / 100% CO₂: 0-10ppm / 100% CH₄: 0-500ppm / 100% O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% ZRE Single Beam High Performance Model (up to 5 gases), ideal for: Combustion Control Biomass Boilers Oxidiser Monitoring Crematoria Control Emissions Monitoring NO: 0-200 / 5000ppm SO₂: 0-20ppm / 10% CO: 0-200ppm / 100% CO₂: 0-100ppm / 100% CH₄: 0-500ppm / 100% O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% ZKJ Dual Beam Low Concentration Model (up to 5 gases), ideal for: Air Seperation Plants R+D Projects Gas Manufacturing NO: 0-50 / 5000ppm SO₂: 0-50ppm / 10% CO: 0-50ppm / 100% CO₂: 0-20ppm / 100% CH₄: 0-200ppm / 100% NO₂: 0-200 / 2000ppm O₂ (Cell): 0-10 / 25% O₂ (Para): 0-5 / 100% O₂ (ZrO₂): 0-5 / 25% SIRA MC130224/00 MCERTS Approval - ZRE Analyser CO: 0 to 125 mg/m³ & 0 to 1250 mg/m³ NO: 0 to 268 mg/m³ & 0 to 2680 mg/m³ SO 2 : 0 to 571 mg/m³ & 0 to 5710 mg/m³ O 2 : 0 to 25% vol & 0 to 10% vol For more information, please contact our sales department 10
ZPAF BIOMASS GAS ANALYSER The ZPAF biomass gas analyser simultaneously and continuously monitors H₂S, CH₄, CO₂ and O₂. FEATURES - Simultaneous Measurement of H₂S, CH₄, CO₂ and O₂ - Compact and Lightweight - LCD Display with Easy to Use Menu - Option for Automatic Calibration - Option for High/Low Gas Alarms - Option for RS485 (Modbus) PRINCIPAL DIAGRAMS SPECIFICATIONS General Repeatability +/- 0.5% FS (H2S +/- 2.0%) Drift +/- 2.0% Week (H2S +/- 2.0%) Required Flowrate 0.5 l/min (+/- 0.2) Gas lnlet/outlet 1/4 NPT (Female) Sensor Life O₂ - 2 years / H₂S - 1 year Display 4 digit backlit LCD Size 133 x 483 x 382 mm Weight 0.9 kg Analogue Outputs 4-20mA DC or 0-1V DC Contact Output (option) 1C Contact Measureable Gas Ranges CH₄ (IR) 0-20 / 100vol% CO₂ (IR) 0-20 / 100vol% H₂S (Fuel Cell) 0-500 / 2000ppm O₂ (Fuel Cell) 0-10 / 25vol% For more information, contact our sales department 11
ZPAF TECHNICAL DRAWINGS ZPAF TYPICAL LAYOUT 12
ZSS/ZSS DUAL LASER GAS ANALYSER The ZSS Dual is the world s first analyser which can measure CO and O2 in one unit. - Near Infrared Laser Technology - Simultaneous Measurement of up to 2 Gases - Excellent Long Term Stability - Ultra High Speed Response Times (from 1 Second) - Direct Insertion Eleminates Maintenance FEATURES - Nitrogen or Air Purge: 20 l/min (0.5-0.7 MPa) - Negligible Interference by Other Gases - Dual Component Measurement of H20 for Dry Gas Reference Conversion (HCl & NH3) - Easy to Read LCD with Easy to Use Menu SPECIFICATIONS MEASUREABLE GASES AND RANGES No. of Gases Measurable Mounting Path Length Detect Limit Display Flange Analogue Out Analogue In Contact Out Contact In Power Supply Consumption Ambient Temp. IP Rating ZSS: 1 gas ZSS Dual: 2 gases In-Situ Stack Mounted 0.5 m to 10.0 m 1% of min. range 4 Digit LCD (Display Unit) JIS 10K, 50A or 100A 4-20ma DC or 0-1V DC 4-20mA DC Relay Out Optional 100 to 240V AC 50/60Hz Approx. 75 VA -20 o C to +55 o C Waterproof IP65 ZSS HCl 0-10 / 5000ppm NH 3 CO CO 2 CH 4 O 2 HCl + H 2 O (HCl) NH 3 + H 2 0 (NH 3 ) 0-15 / 5000ppm 0-2 / 50vol% 0-2 / 50vol% 0-100ppm / 50vol% 0-4 / 50vol% ZSS Dual 0-50 / 1000ppm 0-50 / 1000ppm CO O 2 (Standard) 0-5 / 50% 0-10 / 100% CO O 2 (Hi-Temp.) 0-200ppm / 2% 0-5 / 50% CO O 2 (Hi-Dust) 0-200ppm / 2% 0-25 / 100% 13
ZSS / ZSS DUAL TYPICAL INSTALLATION ZSS / ZSS DUAL TYPICAL APPLICATIONS Application 1: Industrial Waste Treatment An ultra-high speed response (2 seconds or less) allows optimum control of the calcium hydroxide injection volume Application 2: Gas Recovery Efficiency High speed response for Calcium Hydroxide Injection Control 14
ZAF/ZAFE THERMAL CONDUCTIVITY ANALYSERS Thermal Conductivity Analysers are used to measure H 2, Ar, He, CH 4 and CO 2. The ZAF Thermal Conductivity Analyser is the standard type while the ZAFE is the flame proof version. FEATURES Measures H2, Ar, He, CH4 and CO2 LCD display with easy to read menu Optional RS232C (MODBUS) communction and automatic zero/span calibration Optional gas concentration alarm output Two measuring ranges (Optional) Corrects influence from other gases ZAFE only: Exd IIC T6Gb Optimum measurement for H2, Ar and He SPECIFICATIONS General Repeatability +/- 1% FS Drift +/- 2% Week Required Flowrate 0.5 l/min (+/- 0.2) Gas Inlet/Outlet 1/4 NPT (Female) Analogue Outputs 4-20mA DC or 0-1V DC Power Supply 100 to 240V AC, 50/60 Hz TYPICAL APPLICATION GAS RANGES Thermal Conductivity Analyser Model ZAF(E) Components Ranges H 2 Option 2 100/90% Option 1 0 to 3/100% Option 3 100/80% Option 1 0 to 5/100% He Option 2 100/90% Option 3 100/80% Option 1 0 to 10/100% Ar Option 2 n/a Option 3 100/80% CH 4 Option 2 100/90% Option 1 0 to 20/100% Option 3 100/80% CO 2 Option 2 100/90% Option 1 0 to 10/100% Option 3 100/80% Gases 1 15
ZAF / ZAFE TECHNICAL DRAWINGS ZAF THERMAL CONDUCTIVITY ANALYSER ZAFE THERMAL CONDUCTIVITY ANALYSER MEASURING PRINCIPAL The analysers determine gas concentrations by using reference and measuring chambers. Both chambers have heated platinum wires within them; when the composition of the gas in the measuring chamber changes, the temperature and electrical resistance of the platinum wire also changes, this change allowing the analysers to determine the change of the measured gas concentration. The analyser then uses the reference chamber to crosscheck the measurement. 16
ZFK7 ZIRCONIA OXYGEN ANALYSER The ZFK7 Zirconia Oxygen Analyser is an integrated analyser to be used in combination with an Multigas Analyser. The oxygen concentration is displayed on the Multigas analyser display. FEATURES - Extractive ZrO2 analyser - Measuring range: 0... 5% min to 0... 25% Vol. max - Perfect stable - No consumable requirements MCERTS and TuV APPROVED with ZRE Analyser CO: 0 to 125 mg/m3 & 0 to 1250 mg/m3 NO: 0 to 268 mg/m3 & 0 to 2680 mg/m3 SO 2 : 0 to 571 mg/m3 & 0 to 5710 mg/m3 O2: 0 to 25%vol & 0 to 10%vol Repeatability Zero Drift Span Drift Response Time Mounting Type Temperature Control Gas Flowrate Analogue Outputs Power Supply Consumption Outer Dimensions Weight SPECIFICATIONS ZFK7 +/- 0.5% FS or less +/- 1.0% FS or less per week +/- 2.0% FS or less per week 20 seconds Indoor wall mounted Built-in 0.5 l/min 4-20mA DC or 0-1V DC (direct to connected multigas analyser) 100 to 240V AC, 50/60 Hz Approx. 100 VA 141 x 170 x 189.5 mm Approx. 3kg TYPICAL APPLICATIONS TYPICAL LAYOUT with ZRE multi-gas analyser - Steel Making - Crematorium Combustion Control - Boiler monitoring - Power generation - Petroleum refining - Petrochemicals - Food production 17
ZKM/ZFK8 ZIRCONIA OXYGEN PROBE ZKM/ZFK8 Zirconia Oxygen Probes are used as combustion controllers in applications which require high energy consumption. The oxygen concentration control ensures complete combustion, thus reducing CO 2 /SOx/NOx emissions and helping prevent air pollution. It is composed of two separate parts: the ZKM Converter and ZFK8 Oxygen Detector. The ZFK8 is available with an optional flow guide tube. ZKM Converter FEATURES - In-situ Design with Integrated Detector Filter - Enhanced Safety Design with Integrated and Remote Power Isolation Functions, including: Thermocouple Failure Emergency Power Shut Off Password Protected Menu Functions - High Speed Response (4 to 7 seconds) - Modular Detector Design allows for Easy Field Replacement of Zirconia Element SPECIFICATIONS ZFK8 Oxygen Detector with flow guide tube Repeatability Drift Response Time Mounting Flange Tube Length Options Measured Gas Temp. Measured Gas Pressure Analogue Outputs Contact Output (Option) Power Supply Consumption ZKM/ZFK8 +/- 0.5% FS or less +/- 2.0% FS or less per month 4-7 seconds JIS5K 65A (80A for high dust) 300mm to 1000mm - 10 C to +600 C (w/ guide tube) - 10 C to +1500 C (w/o guide tube) -3 to +3 kpa 4-20mA DC or 0-1V DC RS-485 Modbus or RS235 Modbus 100 to 240V, 50/60Hz Approx. 100VA ZFK8 Oxygen Detector For more information, please feel free to contact our sales team 18
Model Method Gas & Ranges ZFK8 Detector ZKM Controller Single Gas O 2 (ZrO 2 ): 0-2/50% (in 1 vol% O 2 steps) Zero Gas: 0.25 to 2.0% O 2 Span Gas: 20.6 to 21.0% O 2 TECHNICAL DRAWINGS 19
ZKM/ZTA ZIRCONIA OXYGEN PROBE ZKM/ZTA Zirconia Oxygen Probes are used as combustion controllers in applications requiring high energy consumption. It ensures complete combustion, reducing system emissions and preventing pollution. It is composed of two separate parts: the ZKM Converter and ZTA Oxygen Detector. The ZTA is an Ejector type detector which makes the probe suitable for applications involving high temperatures. FEATURES - In-situ Design with Integrated Detector Filter - Enhanced Safety Design with Integrated and Remote Power Isolation Functions, including: Thermocouple Failure Emergency Power Shut Off Password Protected Menu Functions - High Speed Response (4 to 7 seconds) - Modular Detector Design allows for Easy Field Replacement of Zirconia Element SPECIFICATIONS ZKM/ZTA Repeatability +/- 0.5% FS or less Drift +/- 2.0% FS or less per month Response Time 4-7 seconds Mounting Flange JIS5K 65A (80A for high dust) Tube Length Options 300mm to 1000mm Measured Gas Temp. -10 C to +1500 C Measured Gas Pressure -3 to +3 kpa Analogue Outputs 4-20mA DC or 0-1V DC Contact Output (Option) RS-485 Modbus or RS235 Modbus Power Supply 100 to 240V, 50/60Hz Consumption Approx. 100VA Pictured Above: ZKM Controller ZTA Ejector For more information, please feel free to contact our sales team 20
Model Method Gas & Ranges ZTA Ejector ZKM Controller Single Gas O2 (ZrO2): 0-2/50% (in 1 vol% O2 steps) Zero Gas: 0.25 to 2.0% O2 Span Gas: 20.6 to 21.0% O2 TECHNICAL DRAWINGS 21
ZKME/ZFKE ATEX ZIRCONIA OXYGEN PROBE The ZKME/ZFKE Zirconia Oxygen Probe is used as a combustion controller in applications requiring high energy consumption. It ensures complete combustion, reducing system emissions and preventing pollution. It is composed of two separate parts: the ZKME Converter and ZFKE Oxygen Detector. They are suitable for applications involving flames and explosive materials. The ZFKE is available with an optional flow guide tube. FEATURES - In-situ Design with Integrated Detector Filter - Enhanced Safety Design with Integrated and Remote Power Isolation Functions, including: Thermocouple Failure Emergency Power Shut Off Password Protected Menu Functions - High Speed Response (4 to 7 seconds) - Modular Design allows for Easy Maintenance - ATEX Certification (TIIS Exd IIB T6, NEPSI / Eexd IIC T6 ExII2G) SPECIFICATIONS ZFKE Oxygen Detector ZFME Converter Repeatability Drift Response Time Mounting Flange Tube Length Options Measured Gas Temp. Measured Gas Pressure Analogue Outputs Contact Output (Option) Power Supply Consumption ZKME/ZFKE +/- 0.5% FS or less +/- 2.0% FS or less per month 4-7 seconds JIS5K 65A (80A for high dust) 300mm to 1000mm - 10 C to +600 C (w/ flow guide tube) - 10 C to +1500 C (w/o flow guide tube) -3 to +3 kpa 4-20mA DC or 0-1V DC RS-485 Modbus or RS235 Modbus 100 to 240V, 50/60Hz Approx. 100VA ZFKE Oxygen Detector with flow guide tube For more information, please feel free to contact our sales team 22
Model Method Gas & Ranges ZFKE Detector ZKME Controller Single Gas O2 (ZrO2): 0-2/50% (in 1 vol% O2 steps) Zero Gas: 0.25 to 2.0% O2 Span Gas: 20.6 to 21.0% O2 TECHNICAL DRAWINGS 23
ZSV PORTABLE ANALYSER The ZSV portable analyser can measure up to 5 gases on the go. It s easy to use and can be continuously used for up to five days. FEATURES - Compact Size with Excellent Functionality - Simultaneous Measurement of Up to 5 Gases: NOx, SO2, CO, CO2, CH4 and O2 - Continuous Measurement for Up to 5 Days - Large LCD Screen with Clear Display - Two Seperate Units for Easy Transport: Gas Analyser Unit and Self-Contained Gas Conditioning Unit - Optional Sample Gas Probe, Primary Filter and Sample Tube SPECIFICATIONS Repeatability Drift O2 Sensor Life Display Analogue Outputs Contact Communication Power Supply Consumption Dimensions ZSV +/- 0.5% FS +/- 2.0% week 2 years 4 Digit Backlit LCD 4-20mA DC or 0-1V DC RS232C (Modbus) 100 or 240V AC, 50/60 Hz Approx. 100VA Analyser Unit: 204 x 265 x 514 mm Conditioning Unit: 370 x 365 x 514 mm For more information, please contact our sales department CO2 CO NO 0-200ppm/100% 0-200ppm/100% 0-500/5000ppm GAS RANGES SO2 0-500ppm/1% CH4 0-1000ppm/100% O2 0-5/25% 24