D Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

Similar documents
D Reliability goes XL

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger coaxial breathing circuits Consumables and Accessories

Focused on essentials DRÄGER SAVINA 300

Resuscitaire Neonatal Open Care

Primus Anaesthesia Workstations

Dräger PAS Micro Short Term Breathing Apparatus

Dräger Pendula Medical Supply Units

D Designed for non-invasive ventilation DRÄGER CARINA

Dräger Savina Sub-Acute Care Ventilation

Dräger Tactical Harness Versatile carrying harness for LAR rebreathers.

Better to have one OXYLOG 3000

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger Bodyguard 7000 Warning Device

MT Excellent performance and reliability EVITA 4 EDITION

Dräger MSI P7 Combustion Gas Analysis

Dräger Short-term Tubes Dräger-Tubes

Dräger CAPITANO 140 Mobile Compressor

Oxylog 2000 plus Emergency & Transport Ventilation

Dräger ABIL-L Airline Equipment

Setting new trends in ventilation. DRÄGER EVITA INFINITY V500

O 2 Star - Oxygen Therapy Accessories Consumables and Accessories

Dräger-Tube pump accuro Dräger Tube Pump

Dräger PAS AirPack 2 Compressed Air Breathing Apparatus

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus

Dräger OCEANUS 140 Mobile Compressor

Dräger PA91 plus Standard and PA91 plus Marine Self Contained Breathing Apparatus

Dräger PARAT 3160 Filter Escape Device

Dräger NITROX 200 Diving Equipment

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Made to meet your needs DRÄGER SAVINA 300

Dräger Bodyguard 1500 Warning Device

Dräger X-plore 6300 Full-Face Mask

Dräger ERS-Chamber Refuge Chambers

Dräger X-plore 3500 Half Mask

VentStar Oxylog Breathing Systems Consumables and Accessories

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Dräger X-plore 5500 Full Face Mask

Filtering Escape Hoods

Dräger X-pect 8500 Goggles Protective Eyewear

Dräger SPC 3700 with CVA 0700 Splash Suit and Vest

Dräger Fabius GS premium Anaesthesia Workstations

Dräger Fabius Tiro Anaesthesia Workstations

Anaesthesia as advanced as your MRI FABIUS MRI

Dräger CPS 6900 Gas-Tight Suit

Training Benzene Awareness. Basic Information

DL D juis Every breath is vital Dräger Gas Management Systems for hospitals

Dräger RZ 7000 Test Equipment

Dräger Fabius plus XL Anaesthesia Workstations

Aquacom Diving Equipment

Dräger Carina Sub-Acute Care Ventilation

Dräger PARAT 3260 Filtering Escape Device

D Beyond essentials DRÄGER SAVINA 300 SELECT

Dräger FGT 5400 Diving Equipment

D The specialist for every environment DRÄGER FABIUS TIRO

Dräger Secor 7000 Diving Equipment and Systems

D The plus that gives you more DRÄGER FABIUS PLUS

Dräger Carina Sub-Acute Care Ventilation

Filtering Escape Device

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Dräger X-plore 9000 and PAS X-plore Airline breathing equipment

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

Dräger Bodyguard 1000 Warning Device

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Dräger TSW Elephant Diving Equipment

D Rising up to the challenge OXYLOG 3000 PLUS

Dräger WorkMaster Industry Gas-Tight Suit

D The plus that makes all the difference DRÄGER FABIUS PLUS

OxyLine The customised pressure reducer

D Make the golden hour your time to shine. RESUSCITAIRE

MT Increase patient comfort and therapeutic benefits Dedicated accessories for Carina ventilator CARINA

Dräger Perseus A500 Anaesthesia Workstations

Dräger Quaestor 7000 Test Equipment

Dräger X-act 5000 Dräger Tube Pump

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Dräger Testor 2500/3500 Test Equipment

Redefining Anaesthesia DRÄGER ZEUS INFINITY EMPOWERED

Dräger Aerotest Navy Test Equipment

Dräger Saver PP Compressed Air Escape

Dräger P7 Pressure, Leak and Leak Rate Measurement

Oxylog VE300 Emergency & Transport Ventilation

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Getting out safely Our escape solutions FILTERING ESCAPE EQUIPMENT COMPRESSED AIR EQUIPMENT OXYGEN SELF-RESCUER REFUGE CHAMBERS TRAINING & SERVICE

D Lightweight Respiratory Protection

Dräger HPS 3500 Head Protection System

D Beyond essentials DRÄGER SAVINA 300 SELECT

Vamos / Vamos plus Anaesthetic Gas Monitors

Dräger PSS BG 4 plus Closed Circuit Breathing Apparatus

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Dräger PAS Filter series Airline Equipment

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger X-plore 8000 headpieces Hoods, helmets, visors and masks

Dräger PSS 7000 Compressed Air Breathing Apparatus

Dräger CDR 4500 Full Face Mask

Focused on essentials DRÄGER SAVINA 300

Increase patient outcome and therapeutic benefits Dedicated NIV accessories for Carina CARINA ACCESSORIES

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Dräger Protec Plus TC and TF Splash Suit

D At your side in the emergency management

Transcription:

D-14582-2009 Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

2 DRÄGER INFINITY ID-ACCESSORIES Just a dream? D-14131-2009

3 Move the patient from induction into the OR without having to reenter ventilation parameters at the anesthesia workstation. Change the water trap on schedule without having to check stickers or logbooks. Connect ventilation circuits and breathing bag without losing control of making a proper connection. With Infinity ID-accessories from Dräger it simply is routine.

4 DRÄGER INFINITY ID-ACCESSORIES Make your connection and breathe easier Connecting breathing circuits, changing water traps and replacing soda lime are some of the many tasks required on a daily basis within an intensive care unit or operating room. Even simple, routine tasks consume valuable time and require constant attention, with every single task just as important as the next. How easy is it to make an incorrect circuit connection? How easy is it to forget to change a water trap? What if the soda lime canister is not properly connected to the anesthetic machine? These mistakes can and do happen, and the consequences can be serious. WHY NOT ENLIST SOME ACTIVE SUPPORT FOR YOUR DAILY ROUTINE TASKS? Infinity ID-accessories from Dräger do more than just fulfill their primary function such as ventilating a patient or measuring parameter values. Each and every Infinity ID-accessory has been designed to offer additional functionality, which that has been demonstrated by the daily clinical routine at Zurich s University Hospital can help you simplify routine tasks, streamline workflow and increase safety levels. This enables you to concentrate on the most important thing your patients. D-14600-2009

5 D-10204-2011 Zurich University Hospital INFINITY ID-ACCESSORIES AND THE DAILY CLINICAL ROUTINE AT ZURICH S UNIVERSITY HOSPITAL Infinity ID-accessories from Dräger have been in use at the University Hospital in Zurich since 2009. Following a successful test phase in the ENT and ophthalmology departments, doctors and caregivers have been working with ID-accessories throughout the hospital s surgical unit. The following Infinity ID-accessories are in use on a daily basis: various Infinity ID breathing circuits the Infinity ID WaterLock 2 water trap the soda lime system Infinity ID CLIC Absorber Free ON THE ROAD TO STANDARDIZATION WITH INFINITY ID Personnel at the University Hospital routinely rotate through different department operating rooms during the day. To ensure the same high standard of care in all areas, hospital management decided to standardize OR workplaces. One milestone toward standardization was Dräger Infinity ID. Doctors and caregivers alike needed little convincing, and everyone involved reported that learning to use Dräger Infinity ID-accessories on their Infinity Empowered devices was easy and highly intuitive.

6 DRÄGER INFINITY ID-ACCESSORIES There s much than D-14537-2009 D-12369-2009 D-14168-2009 MT-0819-2008 D-12634-2009 D-14546-2009 D-14586-2009 D-14190-2009 D-21994-2009 D-14395-2009 D-14469-2009 MT-0821-2008 D-14281-2009

7 more to it meets the eye D-14319-2009 D-14176-2009 Dräger Infinity ID-accessories Supporting care. Supporting you. D-14183-2009 D-14185-2009 D-12561-2009 D-14195-2009 D-14192-2009 D-14269-2009 D-14301-2009 D-14311-2009 D-14326-2009 D-14373-2009 D-14558-2009

6 DRÄGER INFINITY ID-ACCESSORIES There s much than D-14537-2009 D-12369-2009 D-14579-2009 D-14168-2009 MT-0819-2008 D-12634-2009 D-14546-2009 D-14586-2009 D-14190-2009 D-21994-2009 D-14395-2009 D-14469-2009 MT-0821-2008 D-14281-2009

7 more to it meets the eye TRANSFER OF VENTILATION SETTINGS (TVS) Transport your patient while the circuit transports the ventilation settings from one device to the next. Begin in the induction room with a Dräger Primus Infinity Empowered (IE) anesthesia workstation. The Primus stores ventilation settings and alarm limits continuously on an RFID chip inside the Infinity ID breathing circuit from the first second on. Ready to transfer to the operating room? Simply remove the breathing circuit from the Primus IE and move your patient with the circuit into the OR. Once you re there, connect the Infinity ID breathing circuit directly with the Primus IE. The parameters stored on the chip are automatically displayed; all you have to do is confirm and ventilation continues using the same settings. D-14319-2009 D-14176-2009 EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH*: Transferring ventilation settings automatically saves lots of time. Not having to input the data a second time cuts down on user errors, which means a higher level of patient safety. D-14183-2009 D-14185-2009 D-12561-2009 D-14195-2009 D-14192-2009 D-14269-2009 D-14301-2009 This function makes ventilation parameters transparent. Infinity ID accessories ensure that initial ventilation settings are carried on continuously. * The statements here and on the following pages are from a questionnaire completed by at doctors and caregivers at the University Hospital in Zurich in 2010. D-14311-2009 D-14326-2009 D-14373-2009 D-14558-2009

6 DRÄGER INFINITY ID-ACCESSORIES There s much than EXCHANGE CONTROL You ll never have to worry about missing an exchange date again our devices will remind you. The Infinity ID water trap from Dräger stores the date of first use on an RFID chip. D-14395-2009 D-14469-2009 MT-0821-2008 At the end of the 28-day replacement interval, the Primus IE will notify you. D-14281-2009 Now you can exchange the water trap on schedule, avoiding damage to devices caused by using old water traps. D-14537-2009 D-12369-2009 D-12634-2009 D-14546-2009 D-14586-2009 D-14168-2009 MT-0819-2008 D-14190-2009 D-21994-2009 EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH: You can keep your eye on the exchange interval because it s shown on the display. The additional functionality of the water trap is extremely useful because it avoids damage to the machine.

7 more to it meets the eye MISMATCH CONTROL Just connect the breathing circuit. The system will help you recognize possible connection errors. The Primus IE recognizes the connector of an Infinity ID breathing bag or Infinity ID breathing circuit. D-14319-2009 D-14176-2009 If a circuit is incorrectly connected, an alarm will sound, enabling you to immediately correct the error. EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH: Correction error monitoring improves patient safety because an alarm sounds if a wrong connection is made. Even when you re careful, incorrect connections do happen. It s reassuring to know that the system can recognize an incorrect circuit connection right away. D-14183-2009 D-14185-2009 D-12561-2009 D-14195-2009 D-14192-2009 D-14269-2009 D-14301-2009 D-14311-2009 D-14326-2009 D-14373-2009 D-14558-2009

6 DRÄGER INFINITY ID-ACCESSORIES There s much than COMPATIBILITY CONTROL You can count on it: The system automatically checks to make sure if the accessories are approved for use together. D-14395-2009 D-14469-2009 MT-0821-2008 For example, is the Infinity ID breathing circuit certified for use with the Primus IE? D-14281-2009 If not, the Primus will inform you of this incompatibility as soon as the connection is made, easily avoiding potential hazards for patients and devices. D-12634-2009 D-14546-2009 D-14586-2009 D-14537-2009 D-12369-2009 D-14168-2009 MT-0819-2008 D-14190-2009 D-21994-2009 EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH: For accessories, the system doesn t just check to see if it s a product from a different manufacturer; it also looks to see if it is certified for use. That has a positive impact on the safety of our patients.

7 more to it meets the eye LOCK-IN CONTROL As quick as a click: The anesthesia workstation lets you know if the CLIC Absorber is not firmly connected. Is the Infinity ID absorber just parked in its holder on the Primus IE? D-14319-2009 D-14176-2009 The Primus IE recognizes this problem right away. The system informs you that the absorber is in park position as soon as ventilation begins, which lets you make a firm connection quickly. EXPERIENCES AT THE UNIVERSITY HOSPITAL IN ZURICH: This function helps us use the machine more effectively. If the absorber isn t properly connected, it can translate to risk for the patient, which is why this function makes an important contribution to patient safety. D-14183-2009 D-14185-2009 D-12561-2009 D-14195-2009 D-14192-2009 D-14269-2009 D-14301-2009 D-14311-2009 D-14326-2009 D-14373-2009 D-14558-2009

6 DRÄGER INFINITY ID-ACCESSORIES There s much than CONFIGURATION CONTROL Get ready to be more efficient: The system automatically sets all parameters to correspond to those of the Infinity ID breathing circuit. D-14395-2009 D-14469-2009 MT-0821-2008 The accessory-specific data for example, for active humidification is stored in the Infinity ID breathing circuit. D-14281-2009 When you connect the circuit to an Evita Infinity V500 ventilator, all settings are transferred automatically no need for separate input of the ventilation settings. D-14190-2009 D-21994-2009 CALCULATION OF REMAINING CO 2 ABSORBING CAPACITY Something you can count on: With the help of the absorber, the system automatically calculates the remaining capacity of the soda lime. How much soda lime has already been used? Thanks to the Infinity ID CLIC Absorber by Dräger, you won t ever have to guess again. D-12634-2009 D-14546-2009 D-14586-2009 As soon as ventilation begins, the Primus IE simultaneously begins to calculate the remaining CO 2 absorption capacity. You can see the results on the self-test page of the Primus user interface. If 80 % of the soda lime has been used, the system will inform you, giving you time to prepare to replace it. D-14537-2009 D-12369-2009 D-14168-2009 MT-0819-2008

7 more to it meets the eye D-14311-2009 D-14326-2009 D-14373-2009 D-14558-2009 D-14319-2009 D-14176-2009 D-14183-2009 D-14195-2009 D-12561-2009 D-14185-2009 D-14301-2009 D-14269-2009 D-14192-2009

8 DRÄGER INFINITY ID-ACCESSORIES INFINITY ID-ACCESSORIES QUESTIONS AND ANSWERS What exactly are ID-accessories? Infinity ID-accessories are based on RFID technology, which is short for Radio Frequency Identification. You may have seen RFID technology used in retail stores. If someone tries to remove an article from a store without paying for it, an alarm will sound at the exit thanks to RFID. With Infinity ID, Dräger has pioneered the use of this technology for clinical use in intensive care units and operating rooms. How does RFID technology work with Infinity ID-accessories? Quite simply: RFID makes a wireless connection between the accessory and the device. When you connect an Infinity ID-accessory to an Infinity IDdevice from Dräger, the accessory and the device exchange data. This data is transformed by the device software into useful additional functionality for your daily clinical routine. Can the radio waves cause harm to myself or my patients? No, the transmitter power is extremely low. The stored data needs to be transferred only a few centimeters between the accessory and the device. Infinity ID conforms to all current standards for medical products as well as for radio devices. Accessory Device Can the data on the radio chip get lost? No, the stored data is always duplicated, which rules out the possibility of losing the data. Does the chip store patient data? D-30226-2011 User Display Yes, but only therapy-relevant data, such as age, weight and size. Names or other personal data are not stored.

9 An Infinity ID-accessories overview MT-2099-2007 MT-2086-2007 Infinity ID Breathing circuit Infinity ID Flow sensor D-19383-2009 D-42848-2012 MT-2005-2008 Infinity ID WaterLock 2 Infinity ID CLIC Absorber Free D-10105-2009 Infinity ID Expiration valve Infinity ID Breathing bag set

10 DRÄGER INFINITY ID-ACCESSORIES Infinity for Primus IE, Evita Infinity V500 DRÄGER DEVICE ACCESSORY DESCRIPTION PERSEUS A500 (SOFTWARE RELEASE 1.0) PRIMUS INFINITY EMPOWERED EVITA INFINITY V500 EVITA INFINITY V300 BABYLOG VN500 Breathing circuits for adults Infinity ID Breathing Circuit Smoothbore Infinity ID Breathing Circuit Smoothbore 300 Infinity ID Breathing Circuit Coaxial Infinity ID Breathing Circuit Watertrap 180 Infinity ID Breathing Circuit Basic 180 Infinity ID Breathing Circuit Basic 250 Infinity ID Breathing Circuit Flex 220 Infinity ID Breathing Circuit Dual Heated Infinity ID Breathing Circuit Heated Breathing bag sets for adults Infinity ID Breathing Bag Set Infinity ID Breathing Bag Set 150 Breathing circuits for children Infinity ID Breathing Circuit Basic (P) 180 Infinity ID Breathing Circuit Watertrap (P) 180 Breathing bag sets for children Infinity ID Breathing Bag Set (P) 110 Breathing circuits for neonates Infinity ID Breathing Circuit Basic (N) 180 Infinity ID Breathing Circuit Watertrap (N) 180 Infinity ID Breathing Circuit Heated (N) Breathing bag sets for neonates Infinity ID Breathing Bag Set (N) 110 Soda lime container Infinity ID CLIC Absorber 800+ Infinity ID CLIC Absorber Free Water trap Infinity ID WaterLock 2* Flow sensor Expiration valve Infinity ID Flow sensor Infinity ID Expiration valve (disposable) * Fixed exchange interval of 28 days. *** This function is not supported by the Perseus A500 and Babylog VN500. ** This function is supported only by the Evita Infinity V500.

11 ID-accessories and Babylog VN500 from Dräger ADDITIONAL FUNCTION Mismatch control Compatibility control Exchange control Transfer of ventilation settings (TVS)*** Configuration control** Lock-in control Calculation of remaining CO 2 absorption capacity*** PART NO. MP00340 MP01325 MP00342 MP01326 MP01350 MP01348 MP01347 MP00344 MP00345 MP00341 MP01330 D-18862-2010 D-6802-2011 Perseus A500 Primus Infinity Empowered MP01340 MP01341 MP01343 MP01327 MP01328 MP00343 MP01329 D-38267-2015, D-43497-2012 Evita Infinity V500, Evita Infinity V300 MX50004 MX50120 * 6872020 6871980 MP01060 D-19538-2009 Babylog VN500

CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Manufacturer: Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Locate your Regional Sales Representative at: www.draeger.com/contact REGION EUROPE CENTRAL AND EUROPE NORTH Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE SOUTH Dräger Médical S.A.S. Parc de Haute Technologie d Antony 2 25, rue Georges Besse 92182 Antony Cedex, France Tel +33 1 46 11 56 00 Fax +33 1 40 96 97 20 dlmfr-contact@draeger.com REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA / PACIFIC Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore 609916, Singapore Tel +65 6572 4388 Fax +65 6572 4399 asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel +507 377 9100 Fax +507 377 9130 contactcsa@draeger.com 90 66 795 15.09-3 Communications & Sales Marketing PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co. KGaA