VACCUPERM Vacuum chlorine gas dosing systems

Similar documents
GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Vaccuperm accessories

Full-Vacuum Chlorinator C 2212 MB / 1

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Chlorinator. MODEL C-731 (Floor Mounted)

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

A measured step forward

ProMinent Gas Chlorination

Highest Quality. Gas Chlorination Systems

2008 by Controlmatik ABW

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Chlorinator MODEL MK-I

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Taking care of the world s water. Wallace & Tiernan Products V10k Gas Feed System

GENO -Flushing Compressor Product Data Sheet F 02

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Measurement of Low GAS & Liquid Flows

swimming pool technology

Section GAS CHLORINATION SYSTEM

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

RAC 2200-X/Y-MV DOMESTIC WATER METER TEST BENCH UP TO DN 50 ( 2 ) MANUALLY OPERATED

Safety Relief Valve HON 832

AUTOMATIC HOSE TEST UNIT, TYPE SPU

ACV-10 Automatic Control Valve

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

OWNER S TECHNICAL MANUAL

Series IRV1000/2000/3000

Constant Pressure Inlet (CCN) Operator Manual

MANUAL KPS Pressure Control Valve

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Precision Mass Flow Meters / Controllers for Liquids and Gases

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

O NEof Premium tools for professionals!

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

CO 2 and O 2 scrubbers

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Inert Air (N2) Systems Manual

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

BY GREGGERSEN CATA LOG

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Valve test benches. Systems overview

WORKHOLDING APPLICATION BOOKLET

Chemical Injection Technologies Installation/Service Bulletin

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

PRESSURE REGULATOR LBM SERIES

VALVES HIDROMATIC VALVE.

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

V10K GAS FEED SYSTEM

Integral type Differential pressure flowmeter VNT Series

FAS-W. Features. Applications. Automatic condensation hygrometer

CHLORINE DIOXIDE GENERATOR

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

deltaflowc deltaflowc Venturi or Probe

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

C-Flow Coriolis Mass Flow Meters

Mass Flow Controller (MFC) for Gases

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ENS-200 Energy saving trainer

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

KRONES filling systems for beer Filling of glass containers and cans

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Variable Area Flow Meters

VACUUM REGULATORS CONTENTS

LPG DRIVER ATTENDED TRANSPORT LOADING

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Tank Blanketing Pressure Regulators RHPS Series

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

WHITEPAPER. Integrated process monitoring of dosing pressures

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

The Discussion of this exercise covers the following points:

Pressure regulators for a wide range of applications

256 Pneumatic Pressure Indicator

CONTROL VALVE TESTING

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

BUBBLER CONTROL SYSTEM

ELADOS EDP L Diaphragm Metering Pump Type

Precision Pressure Regulators. Precision Fluidics

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Instruction Manual EMA 84 Digital Pressure Gauge

TECHNICAL DATA. Q = C v P S

Mass Flow Meter (MFM) for Gases

Transcription:

VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es

VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling, transport and storage of chlorine for water disinfection is a challenge to systems engineering. This is the reason why the vacuum principle has been used in dosing systems for a long time already. The pressure of the chlorine gas is reduced to the vacuum. This method successfully avoids chlorine gas leakage. In the event of a pipe breakage, no chlorine gas can escape, only ambient air is drawn in. Principal components Vacuum chlorine gas dosing systems are composed of two principal components: vacuum regulator and dosing regulator. The vacuum regulator is a pressure reducing valve that reduces the overpressure from the chlorine tank side to the negative pressure on the vacuum side. The valve opens when a sufficient vacuum is present on the outlet side. Vacuum regulators with pressure gauge and liquid trap are available for more safety. The second system component is rotameter that regulated the chlorine gas volume flow. This can be effected manually or automatically. 2 clorep

Principle of vacuum chlorine gas dosing systems 6 2 3 4 7 Nº Component 1 Chlorine gas cylinder 2 Vacuum regulator 3 Dosing regulator 5 4 Injector 5 Adsorption cylinder (optional) 1 6 Safety valve (option) 7 Change-over device (option) VGB series combines a vacuum regulator and a dosing in a compact unit. It corresponds a independent model of vacuum regulators of up to 10 kg/h. VGS series includes regulators and dosing models of high capacity (up to 200 kg/h. Vaccuperm provides: Safe and easy use Precise regulation and dosing of gas (chlorine / ammonia) All the parts in contact with the media are made of corrosion-proof materials Large variety of models and extensive possibilities of combination Easy installation Low operating costs Approved disinfection method complying with most drinking water regulations VACCUPERM 3

VGB-103 Compact dosing unit Vacuum regulator and dosing regulator in a single unit for direct mounting on a chlorine gas cylinder. Available up to a maximum volume dosage of 2000g/h. Typical installation scheme 5 2 ca. 257 131.7 82.4 1 63 146 3 6 ~10cm 126 92 VGB-103 ca. 257 187.8 131.7 81.8 82.4 63 146 126 4 71.1 Dimensional scheme 101 31.4 ca. 197 14 40.3 125 ca. 92 100 VGB-103 71.1 31.4 101 31.4 ca. 197 14 40.3 4 clorep 81.8 187.8

VGA-111 Vacuum regulator up to 4000 g/h Vacuum controller that incorporates an inlet valve and a gas filter, as well as a safety valve against overpressures. It can be installed on a chlorine cylinder or a header line. It exists the option to include a pressure gauge with minimum pressure contact. For those cases which the installation has to be done on a collector, we offer a vacuum regulator that incorporates a splitter and a liquid trap. Capacity range up to 4000 g/h. Dimensional scheme Vacuum regulator VGA-111 146 63 60.6 213.8 187.8 339.4 closed yoke VGA-111 31.4 Vacuum regulator VGA-111 with liquid trap. 203.8 Optional: liquid trap 235.8 VACCUPERM 5

VGA-113 Vacuum regulator up to 4000 g/h Gas dispenser for assembly to wall, incorporates a measurement device and a valve of gas flow adjustment. The dosage unit can be supplied with a servomotor for an automatic dosage adjustment. The servomotor has two options: potentiometer inverter or analogic control (4-20 ma). The equipment is available until 4000 g/h. Dimensional scheme without servomotor 46.5 190 95 178 50 236 120 72.5 ~ 140 72.5 38 ~ 118 7 38 ~ 118 9 0 ~ 82 6 clorep

Dimensional scheme with servomotor 46.5 95 50 ~ 410 ~ 260 120 ~ 92 72.5 ~ 140 72.5 ~ 118 40 7 40 118 VACCUPERM 7

VGA-146 Vacuum regulator up to 10 kg/h Vacuum regulator for assembly to wall, directly in bottle / gas cylinder or gas collectors line. It incorporates an inlet valve and another safety valve for overpressure. Also it incorporates a pitfall of liquid and an internal filter. Its regulation capacity it is up 10 kg/h. Dimensional scheme ca. 119 ca. 198 ca. 172 M6 ca. 236 ca. 127 150 ca. 173 ca. 160 ca. 200 ca. 62 ca. 126 c c a a ca. 5 c c a a ca. 86 8 clorep

VGA-117 Dosing regulator up to 10 kg/h Gas dispenser for assembly to wall that incorporates a device of measurement and a valve of adjustment of gas flow. The servomotor has two options: with potentiometer inverter or analogical control (4-20 ma). The equipment is available up to 10kg/h. Dimensional scheme Ø 6 107 Ø 6 375 400 575 600 170 145 12.5 12.5 80 46 130 105 12.5 12.5 80 46 VACCUPERM 9

VGS-141, VGS-143 & VGS-145 Gas dosing system up to 200 kg/h Vaccuperm VGS incorporates the last generation sensors and electronic microprocessors to control flow dosage. Several sensors connected to a PLC offer a big variety of control possibilities and error detection that results in safety increasing during the whole process. Pressure sensors for more safety We have at your disposal optional pressure sensors that allow the rapid detection of disorders such as insufficient vacuum in the ejector or errors in the vacuum regulator. Precise measurement system for rotameter The inductive sensor is not susceptible to fouling and never comes into contact with the gas dosed. The signal resolution is approximately 2% of the maximum value of the measuring range. System with direct proportional control Optionally, the valve servomotor adjustment can be equipped with electronic (4-20 ma input) for direct proportional control without additional electronic control systems. Automation of dispensing proces You can optionally integrate a controller with PID microprocessor control. Ergonomic design for easy maintenance All elements and control devices have been installed at the level accessible for a easy manipulation. It also has a selector shift operation manual to automatic operation. All maintenance service can be executed with a few standard tools. Excellent precision and stability The new construction of the valve adjustment and pressure differential regulator optimized to provide computer simulation results in excellent reproducibility and stability at a time dosing. 10 clorep

Dimensional scheme 610 390 DN 40=730 DN 20=760 1810 1000 1000 50 450 Typical installation scheme Nº Description 1 Gas cylinder 1a Scale cylinder gas 2 Emergency stop button 16 2 4 3a 7 18 8 9 17 16 15 3 Lifting device for gas cylinders 3a Hook lift 5 1000 kg 1000 kg 1 1a 14 6 4 Automatic system 5 Nitrogen filling device 6 Evaporator 16 16 7 Filter and pressure reducing valve 8 Vacuum regulator VGS 11 12 10 13 9 Dosing system VGS 10 High capacity ejector 11 Water circulation pump 12 Flowmeter with outputs 4-20 ma 13 Injection point 14 Sensor gas leak 15 Optical and acoustic alarm 16 Cannula suction gas to the neutralization system 17 Central control panel with interface computer 18 Spray system VACCUPERM 11

VGS-147 & VGS-148 Vaccum Regulator up to 200 kg/h Regulator vacuum gas to install on gas manifold. Includes a safety valve and a trap of liquid. Equipment is available up to a capacity of 200 kg/h. Dimensional scheme VGS-147 209 52 DN 20 170.5 105.5 175 128 DN 25 Dimensional scheme VGS-148 DN 40 206 125 245 6.6 170 50 245 170 DN 25 12 clorep

RV-171 & RV-171W Evaporators for liquefied gases (Cl 2 / NH 3 ) Automatic evaporator transforms liquefied gas taken from the storage tank by using heat exchange. The heat transfer medium can be water with anti-corrosive additives and antifreeze or oil. Dimensional scheme RV171 ~ 730 ~ 670 DN 25 1293 DN 25 125 100 203 1805 14 Dimensional scheme RV-171W & RV-171 RV-171W RV-171 VACCUPERM 13

TECHNICAL DATA VGB & VGA VGB-103 compact unit VGA-111 vacuum regulator VGA-113 dosing regulator VGA-146 vacuum regulator VGA-117 dosing regulator Capacity range 5-100 g/h 25-500 g/h 100-2.000 g/h up to 4.000 g/h 10-250 g/h 50-1.000 g/h 400-4.000 g/h up to 10 kg/h 50-1.000 g/h 200-4.000 g/h 500-10.000 g/h Adjustment ratio 1:20 1:20 1:20 Accuracy ± 4% ± 4% ± 4% Measuring device According to the floater principle, measuring tube 70 mm According to the floater principle, measuring tube 70 mm According to the floater principle, measuring tube 190 mm Empty indication Visible automatical signal for lack of chlorine Visible automatical signal for lack of chlorine Materials Enclosure: PVC Inlet valve: Silver / PTFE / special alloy Springs: Coated with nickel-chrome alloy Diaphragm: FEP Rate valve: PVC O-rings: FKM Connections Pressure side chlorine: Union nut G 1" Vacuum line: PE hose 8/11 mm Vacuum safety line: PE hose 8/11 mm Pressure side chlorine: Union nut G 1" Vacuum line: PE hose 8/11 mm Vacuum safety line: PE hose 8/11 mm Vacuum safety line: PE hose 8/11 mm Pressure side chlorine: Union nut 1", G 3/4, Vacuum safety line: PE hose 10/14 mm o PVC pipe DN 15 (external diameter 20 mm) Vacuum line: PE hose 8/11 mm or 10/14 mm or PVC pipe DN15 Vacuum safety line: PE hose 8/11 mm Options Manometer: 0 to 16 bar External filter Manometer: 0 to 16 bar External filter Liquid trap Automatic control with servomotor (4-20 ma or direct control) Automatic control with servomotor (4-20 ma or direct control) Servomotor power consumption approx. 3 VA approx. 3 VA Variant with servomotor Potentiometer or opening/closing signal (servomotor with potentiometer) Analogue regulation 4-20 ma or input/ output (servomotor with analog control) Potentiometer or opening/closing signal (servomotor with potentiometer) Analogue regulation 4-20 ma or input/ output (servomotor with analog control) Weight 1.3 to 2.0 kg 2.3 kg 0.9 kg; 3.1 kg with servomotor 2 kg; 4 kg with heater anti liquefying 2.6 kg; 4.8kg with servomotor VGB-103 VGB-111 VGB-113 VGB-146 VGB-117 14 clorep

TECHNICAL DATA VGS & RV-171 VGS-141-010 Gas dosing system VGS-143-040 Gas dosing system VGS-145-200 Gas dosing system VGS-147-040 Vacuum regulator VGS-148-070 Vacuum regulator VGS-148-120 Vacuum regulator VGS-148-200 Vacuum regulator Dosing quantity 500-10.000 g/h 50-1.000 g/h (NH 3 ) 250-5.000 g/h (NH 3 ) 1-20 kg/h 2-40 kg/h 0.5-10 kg/h (NH 3 ) 1-20 kg/h (NH 3 ) 3.5-70 kg/h 6.0-120 kg/h 10.0-200 kg/h max. 40 kg/h max. 70 kg/h max. 120 kg/h max. 200 kg/h Ratio adjustment 1:20 Precision ± 4% Minium pressure admission High pressure admission 2 bar 11 bar Connections PVC pipe DN15 PVC pipe 20/25 PVC pipe 40/50 PVC pipe 20/25 PVC pipe 40/50 Options Support plate for wall subject during container change Installation material in three lenghts RV 171W-100 RV 171W-200 RV 171-100 RV 171-200 RV 171-170 RV 171-270 Gas Cl 2 Cl 2 Cl 2 Cl 2 NH 3 NH 3 Heating medium Water Water Oil Oil Oil Oil Capacity 100 kg/h 200 kg/h 100 kg/h 200 kg/h 21 kg/h 42 kg/h Power 9 kw 18 kw 9 kw 18 kw 9 kw 18 kw Heating time approx. 4 minutes approx. 4 minutes approx. 5-7 minutes approx. 5-7 minutes approx. 5-7 minutes approx. 5-7 minutes Maximum working pressure 12 bar, with rupture disc to 16 bar Max. space temperature 0-40 ºC Input/Output connections DN25 (G 1") VGS-141/143/145 VGS-147/148 RV171 VACCUPERM 15

ELÈCTRICA PINTÓ, SL Pol. Ind. Santa Anna I Ctra. BV-4511 km. 4,2 08251 Santpedor Barcelona (Spain) Tel.: (+34) 938 366 036 Fax: (+34) 938 366 031 E-mail: comercial@clorep.es www.clorep.es Official distributor: 5001DO009I.1_06-16