AQUABIOME. Installation & Instruction Manual. ! WARNING

Similar documents
centrifugal pre-filtration

pumps Pool

HYDROCHLOR. Salt water pool chlorinator.

Installation and Operation Manual

Installation and Operation Manual

SAFE. The ChemfloPlus s Smart LCD display shows you the condition of your pool water and what ChemfloPlus is doing about it.

HYDROCHLOR. Salt water pool chlorinator.

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

200 / 300 Upgrade Kits

After filling the pool with clean water in the summer, two basic factors can take place due to the exposure of water to the sun and the air.

Installation, Operation Instructions & Warranty Booklet

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

UPGRADE KIT. Installs a new EAZY filter into Nexus 200 / 300 manufactured after 2006 and Nexus 210 / 310 manufactured after 2009

Super-Clean SCT Series SuperClean Sand Filter. Installation Manual

LIBERTY and PATRIOT SAND FILTER SERIES INSTALLATION & OPERATION MANUAL. RX Clear Patriot Sand Filters

Cristal -Flo II Filter OwnerÕs Manual

Countrywide Pools Northam

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

CHLORINE FREE POOL.

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Pool Information 2015

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Hurlcon KX Siesta Above Ground Salt Water Chlorinator by AstralPool Australia

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-SS40 Salt System Installation and Operating Instructions

VX Series Salt Chlorinator S Model

Installation Operation Maintenance

1. CONDITIONS FOR USE 2. SAFETY

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

OPERATION MANUAL NTF-60 Plus

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Manual Actuated Boiler Blowdown Valves

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Purifier for Vinyl Lined Pools

Vessel Installation and Operating Manual

1020 Industrial Drive, Orlinda, TN fax

MF2M Monnier Miniature Compressed Air Filter

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

OPERATION MANUAL NTF-15

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

REFRIGERATION SYSTEM COMPONENTS

Operation and Maintenance Manual. First Defense and First Defense High Capacity. Vortex Separator for Stormwater Treatment

Swimming Pool Winterizing

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Vortex Spas User Manual

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

VX-3 Series Salt Chlorinator

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

TECHNICAL INFORMATION

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by

Pressure relief valve

Arcadia Spas User Manual

VX Series Salt Chlorinator T Model

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

HGC-200 Hydro Gas Chlorinator

PRESSURISED PAINT CONTAINER

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Appendix A. Imbrium Systems Jellyfish Filter Inspection and Maintenance Information

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Geotech 1.66 Auto-Reclaimer Installation and Operation

Installation and Operating Manual

776 Cryogenic Safety Valve

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

HIGH PERFORMANCE POOL & SPA PUMPS

MAINTENANCE AND OPERATING MANUAL

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

400C & 450C DUAL PERFORMANCE VALUE PACKS

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

Easy Nest Kits. Installation Suggestions

200 PSI COMPRESSORS - MODEL NUMBERS

APVMA Approval No /3/0204. Instruction Manual & Warranty Card

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Installation and commissioning instructions 255 series and 256 series

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Dri-Line Mk3 Monnier Compressed Air Drain Trap

POOL CARE GUIDE. The E-Z Clor System To Perfect Pool Water.

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Installation and Operation Manual. Jandy Fiberglass Sand Filters. JS Series Sidemount Sand Filters WARNING

PRAHER PLC-MP AQUASTAR MANAUL 2009

444C DUAL PERFORMANCE VALUE PACK

Two-stage valve type NE

1805 Series Relief Valves

FOAM FRACTIONATORS. Also Known As. Phoam Phraxtionators Protein Skimmers Air Strippers

Eaton Filtration, LLC

The Refurbishment of Filtration & Chemicalisation Systems On A Recent Project

TROUBLESHOOTING GUIDELINES

553 Series.

Transcription:

AQUABIOME Installation & Instruction Manual! WARNING This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could result in property damage, serious injury or death. Improper installation will void the warranty. Notice to Installer This manual contains important information about the installation, operation and safe use of this product. Once the product has been installed this manual must be given to the owner/ operator of this equipment. www.waterco.com

Table of AQUABIOME ------------------------------------------------- 01 Filtering Pond Water ------------------------------------ 01 A Typical Pond Filter System --------------------------- 02 The Benefits Of Using An Aquabiome ---------------- 03 How Does The Aquabiome Filter Work? --------------- 04 Choosing The Correct Aquabiome For Your Pond ---- 05 Installation Instructions --------------------------------- 06 Starting Up the Aquabiome ----------------------------- 07 Backwashing Procedure for the Aquabiome ---------- 08 IMPORTANT NOTES ---------------------------------------- 09

Waterco Aquabiome I pg 01 AQUABIOME Aquabiome has been engineered specifically for ponds and water gardens. Aquabiome provides mechanical and biological filtration in a single housing. Its ability to support dense populations of nitrifying bacteria, its reliability and easy maintenance, makes Aquabiome especially suitable for high density recirculation systems. Effective Excellent Nitrification and Mechanical filtration Efficient Hydraulically efficient filter design, balanced slotted laterals to maximize water flow and filtration. Durable Corrosion resistant and UV stabilised for outdoor installation. Air-Backwash Air assisted hydraulic backwash, saving time and water. Superior Quality Aquabiome fibreglass filters embody the latest in fibreglass winding technology. Filtering Pond Water To maintain good water clarity and a safe environment for fish, the pond water requires a combination of the following features: 1. Mechanical Filtration 2. Biological filtration 3. U.V. Sterilisation 4. Good circulation 5. Aeration In simple terms, the mechanical filtration is basically straining the water, separating the solids from the liquid. The solid matter in a pond is usually made up from different forms of debris, which maybe found at any level in the water. The presence of these solids and suspended particles will make the pond water appear murky or cloudy, making it difficult for visual inspection of the fish. The water clarity may not necessarily be a problem to the fish, provided the debris and suspended solids are of a non-harmful nature.

However, some of the debris in a pond can create problems for the fish, often caused by Ammonia, which is produced by faecal, mucus, and other decaying matter. To overcome the build up of harmful Ammonia in the pond water, it is necessary install a Biological filter. Most often, a Biological filter is a large chamber full of media, which breeds and cultures good bacteria. Within the Biological filter, the good bacteria consume and convert the harmful Ammonia into harmless Nitrate. Conventional pond filtration systems generally keep the mechanical and Biological filtration aspects separate, and as such the equipment involved can be rather large and bulky. In addition to the size considerations, most conventional filter systems may require a high degree of maintenance and cleaning. This can prove to be very time consuming particularly during the summer months, when the frequency of cleaning can be so often, it becomes impractical. Combined with the Mechanical and Biological filtration, it is essential that the pond water is recirculated (turnover time) at a rate of every: 2 3 hours. A Typical Pond Filter System Most basic conventional Pond filter systems employ a stage process, which may comprise of the following parts. (i) First stage - Sedimentation chamber or Vortex (ii) Second stage - Aeration for Biological filters (iii) Third stage - Biological chamber filter (iv) Fourth stage - Hi Rate sand filter (v) Fifth stage - U.V. Sterilisation (vi) Sixth stage - Venturi or waterfall In a filter system of the above type, the first stage can be a simple chamber with baffle plates, or a more sophisticated Vortex chamber, which will remove between 50 70% of the solid waste matter. The second stage would be air supplied by a simple air pump and air stone, injecting the air directly into the water flowing through the Biological filters. The Oxygen provided will enhance the life and growth of the bacteria colonies assisting with the removal of Ammonia. The third stage can comprise of several media types and may assist in clearing another 15 20% of the debris, though these filters can be very difficult to clean.

Waterco Aquabiome I pg 03 Whilst the Fourth stage The Hi Rate sand filter, will work efficiently in removing the remaining solids down to 7-10 microns in size & maintaining water clarity. However a downside in using a pressure sand filter is, that it may clog very rapidly (perhaps on a daily basis) which would cause the need for regular cleaning or backwashing. The fifth stage Uses Ultra Violet light to sterilise and for inhibiting the growth of Algae and other undesired organic matter. The sixth stage Aeration for the pond supplied either via a Venturi (and or) a waterfall. A waterfall can make a very attractive feature in the pond, though it may cool the water, which could inhibit fish growth. Any pond filter system must run 24 hours a day seven days a week! This is essential to ensure that all aspects of the system work on a continuous basis to ensure a safe and healthy environment for the fish to live. Therefore, a major consideration for the pond owner is the power and water consumption used to maintain the pond filtration. Usually, Hi Rate sand filters need a fairly powerful pump to force the water through the fine sand, and this can prove expensive when running on a continuous basis. Likewise, the frequency of backwashing will lead to a large volume of water being required. This too can prove costly in the long run. The Benefits Of Using An Aquabiome The principal of using an Aquabiome is to combine the Biological filtration aspect with the mechanical filtration (water polishing). By combining these two filtration aspects (mechanical & Biological), using an Aquabiome, the whole system can be more compact than a traditional - conventional pond filter system. Or, the Aquabiome can also be used to enhance an existing system. In addition, the Aquabiome requires far less pressure than a conventional Hi Rate sand filter, therefore the type of pump needed will require far less power. Possibly reducing power use by 50%! Perhaps most important of all, an Aquabiome will require far less maintenance cleaning or back washing than a typical Hi Rate pressure sand filter. This will mean you could save a considerable amount of wasted water and time, whilst keeping your pond in tip top condition!

How Does The Aquabiome Filter Work? The Aquabiome should be installed after your strainer/vortex and main biological filter system. A suitably sized pump must be selected to ensure the correct water flow is delivered to the Aquabiome. Once installed, the Aquabiome will remove suspended solids down to 10 microns in size, maintaining your water clarity to a very high standard. The pumped water is fed to the Multi-port valve and diverted to the lower filter inlet. The inflowing water is evenly dispersed through the special slotted pipes (Laterals) within the lower section of the filter. The contaminated water flows upwards through the filter vessel depositing waste matter between the crevices of the Biomedia. To assist the growth of Bacteria for removal of the Ammonia present in the contaminated inflowing water, you will need to charge the system with: Filter Start. Once added to the inflowing water, good bacteria will begin to colonise on the filter media enhancing the biological action. The Aquabiome is designed to reduce the amount of maintenance (and waste water) required and ideally if the equipment has been correctly sized, backwashing will only be required on a weekly basis. The backwashing process is assisted by the use of a very powerful blower (air compressor) and the whole procedure will take less than 5 minutes to perform. (See general running instructions). The Aquabiome is designed to ensure servicing simplicity. The main filter body has a large 8 diameter lid for easy access to the internals of the filter. Both the top collector assembly and laterals can be easily unscrewed and removed for cleaning.

Waterco Aquabiome I pg 05 Choosing The Correct Aquabiome For Your Pond Aquabiome ASM400 ASM500 ASM600 ASM750 ASM900 Nominal Diameter mm / inch Filter Surface Area m2 / ft2 Media Volume litres / gallons 400 / 16 500 / 20 600 / 24 750 / 30 900 / 35 0.13 / 1.4 0.2 / 2.1 0.3 / 3.2 0.44 / 4.9 0.64 / 7.15 43 / 11.3 68 / 18 117 / 30.9 199 / 52.6 303 / 80 Media Weight kg / lbs 21.5 / 5.7 34 / 9 58.5 / 15.45 99.5 / 26.3 151.5 / 40 Biofilter Surface Area m2 / ft2 47.3 / 509 74.8 / 805 128.7 / 1385 218.9 / 2356 333.3 / 3588 Inlet / Outlet Connections Min - Max Flow Rate 40mm/ 50mm [EU] / 1 1 /2 40mm/ 50mm [EU] / 1 1 /2 40mm/ 50mm [EU] / 1 1 /2 50mm / 63mm [EU] / 2 50mm / 63mm [EU] / 2 lpm 52-101 80-157 120-226 180 353 255-509 m3/hr 3.1 6.1 4.8 9.4 7.2 13.5 10.8 21.2 15.3 30.5 gpm 13.7 26.7 21.1 41.5 31.7 59.7 47.6 93.3 67.4 134.5 Max Pond Size litres / gallons Feed Rate kg / lbs per day Total Ornamental Fish weight* kg / lbs Total Aquaculture Fish weight* kg / lbs Tank Diameter mm / inch Overall Height mm / inch 13,000 / 3,434 20,000 / 5,300 36,000 / 9,500 60,000 / 15,900 90,000 / 24000 0.32 / 0.71 0.5 / 1.1 0.9 / 1.98 1.5 / 3.31 2.4 / 5.29 10.7 / 23.6 16.7 / 36.8 30 / 66.1 50 / 110.2 80 / 176.4 32 / 70.5 50 / 110.2 90 / 198 150 / 330.7 240 / 529 421 / 16.5 520 / 20.5 622 / 24.5 772 / 30.4 923 / 36.3 856 / 33.7 815 / 32.1 880 / 34.6 993 / 39.1 1115 / 43.9 Valve Size mm / inch 40 / 1 1 /2 40 / 1 1 /2 40 / 1 1 /2 50 / 2 50 / 2 Bed Depth mm / inch 290 / 11.4 290 / 11.4 360 / 14.2 400 / 15.7 440 / 17.3 * Maximum fish stocking weight depends on the percentage of body weight fed daily. Ornamental fish weight based on feeding rate of 3% of body weight. Aquaculture fish weight based on feeding rate of 1% of body weight.

Installation Instructions: 1. Prior to installation: Prepare an area large enough to stand all the equipment allowing adequate space for connecting pipe-work and routine servicing. Once you have decided on the optimum position, prepare a flat and level concrete base to accommodate the unit. 2. Remove filter Air blower and pipe-work from packaging. Check to ensure all parts are present and are in good condition. 3. Place the main filter unit on the pre-prepared concrete base making sure that both the blower and the filter vessel are secure. 4. Connect the Multi-port valve onto the top and bottom bulkheads, ensuring that the O rings are in place. Tighten the connecting unions by hand only. 5. Connect the Non Return Valve unit between the Multi-port Valve and the blower unit ensuring that all O rings are in position. Tighten the connecting unions by hand only. 6. Connect the waste - water sight glass assembly to the waste connection of the Multi-port valve (on LHS) ensuring that the O rings are in place. Tighten the connecting unions by hand only. 7. Connect the isolator valve unit to the main Multi-port valve (RHS) ensuring that O rings are in place. Tighten the connections by hand only. 8. Screw on the return union to the remaining position (on the lower - RHS) of the Multi-port valve. Tighten the connection by hand only. 9. Use PTFE tape around the threads of the pressure gauge and screw into the threaded hole on the side of the Multi-port valve. There are two positions for this, so install the gauge to the most easy to see position and use the screw cap in the opposite hole. Be sure NOT to over tighten the pressure gauge as this will damage the threads! 10. Cut and glue pipe-work from your pump discharge to the small isolator valve already fitted as described in item 7 above. Be sure not to stress any pipe-work by providing suitable supports, where required. NOTE: All pipe-work connections are BSP ABS Pipe-work. Ensure you use compatible adhesive and pipe! 11. Cut and glue pipe-work between the waste line sight glass unit and the drain, again ensuring that all pipe-work is well supported. 12. Cut and glue pipe-work between the return union on the Multi-port valve and the pipe-work back to the pond. This return line may include a U.V. light system, but again ensure all pipework is supported.

Waterco Aquabiome I pg 07 13. Once all glued pipe connections have been completed, ensure adequate time for the adhesive to dry. Most likely this will be at least 12 hours. 14. IMPORTANT! Ensure the pipe-work and glued joints have had adequate time to vent any toxic (or flammable) fumes, before starting the air blower. Ideally, run the water pump for at least an hour before testing the blower on the system. 15. IMPORTANT! The electrical connection of the blower must be made by a qualified electrician, and in accordance with local regulations. The blower unit must be protected by an RCD - residual current device. 16. Remove the main filter lid, then, unscrew the top collector assembly. Check to ensure all the Laterals are securely in place in the bottom of the filter. 17. Ensure you have the correct amount of media as stated in the table above in section 5 Specifications. Carefully pour in the media into the filter avoiding any spillages. Once the whole amount is in the filter, re fit the collector unit and then, the main filter lid. Starting Up The Aquabiome 1. Re-check all threaded connections to ensure they are watertight and select Filter mode on the Multi-port valve. 2. Select the open position of the isolator valve, this will be when the white arrow is pointing to 12pm position and the handle is across the pipe-work. 3. Ensure system water level is to correct level and start the main circulating pump. Water will begin to flow through the filter, which should be observed at the top of the vessel within a few moments. With the filter and valves in this position, the filter is working in it s normal Filter mode. 4. Once the unit has been run for a while, check all joints to ensure there are no leaks. To check that the blower is functioning correctly, follow the backwash procedure as stated below. 5. Once all parts of the system have been tested, add some filter start to prime the filter for biological growth. (Consult your dealer).

Backwashing Procedure For The Aquabiome 1. Turn the circulating pump off. 2. Select 3pm position on the isolator valve (handle in line with pipe). 3. Select Rinse position on the Multi-port Valve. 4. Ensure waste line is unobstructed and the circulation pump is NOT switched on! Switch blower unit on and run for 2.5 3 minutes. This will agitate the media causing the entrapped debris to disperse into the available water within the filter. Some of the contaminated water will discharge to waste. Switch blower off. 5. Keep the Multi-port valve in rinse mode, but alter the position of the isolator valve back to the 12pm position. 6. Switch the circulation pump on and run for 2 3 minutes, during this time dirty water will discharge eventually clearing. Switch pump off. 7. Select backwash mode on the Multi-port valve. Run the circulation pump for 30 40 seconds. This will remove any remaining debris. Switch pump off. 8. Select filter mode on the Multi-port valve and continue to filter as normal.

Waterco Aquabiome I pg 09 IMPORTANT NOTES: Never try to run the Blower and the circulating pump at the same time! (Fig 1) (Fig 2) Regularly check the 3mm vent hole on the Blower pipe T to ensure it is unobstructed allowing moisture to drain from the unit. (Fig 1) Regularly check the Non return valve to ensure water is not bypassing, which could cause the blower to flood. (Fig 2)

Offices - Australia NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS - Melbourne Tel: +61 3 9764 1211 WA - Perth Tel: +61 8 9273 1900 SA/NT - Adelaide Tel: +61 8 8244 6000 ACT Distribution Tel: +61 2 6280 6476 OFFICES - OVERSEAS Waterco (Europe) Limited Sittingbourne, Kent, UK Tel: +44 (0) 1795 521 733 Waterco France Saint Priest, France Tel: +33 4 72 79 33 30 Waterco (USA) Inc Augusta, Georgia, USA Tel: +1 706 793 7291 Waterco Canada Longueuil, Quebec, Canada Tel: +1 450 748 1421 Waterco (NZ) Limited Auckland, New Zealand Tel: +64 9 525 7570 Waterco Limited Guangzhou, China Tel: +86 20 3222 2180 Waterco (Far East) Sdn Bhd Selangor, Malaysia Tel: +60 3 6145 6000 PT Waterco Indonesia Jakarta, Indonesia Tel: +62 21 4585 1481 Waterco Singapore Intl Pte Ltd Nehsons Building, Singapore Tel: +65 6344 2378 Waterco Limited ABN 62 002 070 733 (W23421) 12/2008