OPERATING INSTRUCTIONS FOR HTWP21 SERIES AIR DRIVEN TORQUE PUMPS

Similar documents
HMP HYDRAULIC PUMPS. Prepared by:- J. Davies Approved by:- M. Dalley 12/03/13 REV NO:- 2 ECO: SAFETY PRECAUTIONS

HYDRAULIC CYLINDER FOR USE WTH:- HVL, HPS, HLS, HSS, HAS, HHS, HHR, HDA & HGS

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Operating Procedure TITON SUBSEA BOLT TENSIONER

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

Instruction sheet for Hydraulic Cylinder

DBML-60/80 Squeeze Tool

Budget Range Operators Handbook

4 ANGLE GRINDER MODEL NO: CAT 52 PART

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Operation and Maintenance Instructions

KJ4000 Operating Instructions & Parts Manual NSN

HYDRAULIC CYLINDER TEST

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

MANUAL BE SERIES Test Benches

Installation and Service Manual

RhinoPro Cartridge Gun Manual

Document How to Set Single Stage Press Pressures

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Code AWC20HP Air Compressor

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

air/hydraulic nut riveter heavy-duty vacuum system

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

30T A/Manual Hydraulic Shop Press

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

24 Litre Air Compressor

Instruction Manual. Maximum Operating Pressure 1,500 bar

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

JACK MODULE HYDRAULIC CYLINDERS

HPB25 Hydraulic Paving Breaker

DK ton, Double-acting, Die-type Crimping Tool

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

80 Litre Suction Oil Drainer

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

AIR STAPLER MODEL: CSG1C Part No

accidents which arise due to non-observance of these instructions and the safety information herein.

Safety and operating instructions

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Troubleshooting Lift Cylinder Drift and Tilt Cylinder Drift

PRESSURE ADJUSTMENT Main pressure adjustment

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Flexfence Swaging Unit. Product Manual. Release 02/16.

50L ENGINE DRIVEN AIR COMPRESSOR MODEL NO: XPPV11 & XPP15 RANGE

Spot Weld Drill Spot Weld Removal System Instruction Manual

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Operation Manual Air Saver Unit ASV5000 Series

1/2 REVERSIBLE RATCHET. 1/2 REVERSIBLE RATCHET MODEL NO: CAT 22b + CAT 91 PART No: & OPERATION & MAINTENANCE INSTRUCTIONS

Air Nailer / Stapler Kit

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

AIR RATCHET WRENCH MODEL NO: CAT21B & CAT90 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC05/14

CUT OFF TOOL MODEL: CAT113

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Models and Hydrostatic Test Pumps

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

PRESSURISED PAINT CONTAINER

2K 600mL Dispense Guns with Built-In Retainers

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

OWNER S TECHNICAL MANUAL

1 DRIVE INDUSTRIAL IMPACT WRENCH

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

35 TON HYDRAULIC PUNCH WARNING

Instruction Sheet 1.0 IMPORTANT RECEIVING INSTRUCTIONS 2.0 SAFETY. 2.1 Introduction. 2.2 Hydraulic Cylinder Safety Precautions (RT-Series)

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Tube Tugger. Operating and Maintenance Instructions. Semi-Continuous Tube Extractor.

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE

AIR/OVER HYDRAULIC JACK 20 TON

Nitrogen Tyre Inflator Owner s Manual

SHHP50 FLOOR STANDING HYDRAULIC PRESS

PDY TON HYDRAULIC CRIMPING TOOL WARNING

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

Owner's Manual Sealweld SuperSeal II Pump

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

NTF-230 OPERATION MANUAL

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Operating Instructions Model and Hydrostatic Test Pump

Portable Hydrostatic Pneumatic Test Pump. Procedure Manual

Advanced Fluid Handling Cart Owner s Manual

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

OPERATION MANUAL NTF-15

SC100V AIR COMPRESSOR

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

NGP-250/500 Nitrogen Generator Quick Start Guide

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Transcription:

Hi-Force HTWP21 series air driven pumps are designed to operate high pressure hydraulic double acting torque wrenches with an operating pressure of 700 bar (10 000 psi). These instructions cover the following models: HTWP2140P Air driven unit with 7.0 bar supply Refer to nameplate on the pump for identification. SAFETY READ THIS MANUAL BEFORE OPERATING THE TOOL. FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN SERIOUS BODILY INJURY. Ensure that all equipment connected to the pump is in good condition and is all rated for 700 bar operating pressure. Always stand the pump on a stable level surface during operation. Never invert the pump or lay it on its side either in use, transport or in storage. Inspect hoses regularly for damage and wear. Do not use hoses that are frayed, abraded or leaking. Never move the pump by pulling the hoses. Do not work with hoses sharply bent or kinked. Do not handle hoses that are pressurised. Oil escaping under pressure can penetrate the skin causing serious injury. If oil is injected under the skin see a doctor immediately. Never pressurise disconnected couplers. Always use eye, ear and hand protective equipment when using this pump and associated equipment. Isolate the pump from the air supply when carrying out maintenance or adjustments (except pressure relief valve adjustments). IDENTIFICATION OF COMPONENTS Refer to diagrams on following pages:- 1. Oil reservoir. 2. Oil temperature/ level gauge 3. Oil filler breather cap. 4. Motor. 5. Oil pressure gauge. 6. Adjustable pressure relief valve. 7. Tool advance coupler (700 bar maximum) 8. Tool retract coupler (120 bar maximum) 9. Drain plug. 10. Air pressure gauge. 11. Pendant signal connections. 12. Pendant air supply connection. 13. Air pressure regulator. 14. Air lubricator control. 15. Air lubricator bowl. 16. Pendant hoses 17. Control pendant 18. Exhaust muffler. 19. Air inlet port G3/8 (3/8 BSP) Page 1 of 8

PREPARING THE PUMP FOR FIRST USE Immediately after unpacking, examine the pump for signs of transit damage and if found contact the shipping company. Establish the oil level in the oil reservoir using the level gauge on the end of the tank. Depending on the shipping method used, the reservoir may either be supplied full or empty. If the reservoir is empty it must be correctly filled before use. Running the pump without oil will result in damage. Page 2 of 8

FILLING OF PUMP WITH OIL Remove the cap (3) from the oil filler. Stand the pump on a level surface and fill the tank via the filler breather (3) with Hi-force HFO46 oil until the oil level is at the maximum level as shown on the level gauge. N.B more oil can be added if desired to assist cooling but never to more than 25mm below the tank lid. If the pump was supplied full of oil then no further action is necessary. CONNECTION OF AIR CONTROL PENDANT The air control pendant has three self sealing quick release connections, one male and two female. The male connection should be connected to the pendant air supply connection (12) on the pump gauge panel. The female connectors should be connected to the pendant signal connections (11). One connection controls tool advance and the other controls tool retract. If the pendant button functions are later found to be incorrect simply swap the connections. AIR SUPPLY An air supply up to a maximum of 10 bar must be connected to the air inlet port (19). However the air regulator (13) should be adjusted so that the reading on the air pressure gauge (10) is a maximum of 7 bar (100psi). Operating the pump at above this pressure may result in damage to the motor. The maximum air consumption of the pump is up to 132m³/h (78 cfm) at maximum pressure and power output. Satisfactory operation can be achieved with lower flow rates but tool operation will be slower. Add viscosity grade 22 air line lubrication oil, to reservoir (15), via filler plug adjacent to air lubricator control (14). Do not use hydraulic oil. Adjust the flow of oil using the air lubricator control to give a drop of oil approx every minute. CONNECTION OF TORQUE TOOL TO PUMP Connect the torque tool to the pump using Hi-Force hoses type HTWH. Ensure both halves of the couplers are clean before connecting. Connect the female coupler on the red hose to the male tool advance coupler (7). Connect the male end of the black hose to the female tool retract coupler (8). Connect the other ends of the hoses to the torque tool. N.B. If using torque tools other than Hi-Force or tools that have been modified, check that the tool is connected correctly so that the advance pump port is connected to the advance port on the tool. Failure to do this may result in tool damage or personal injury. INITIAL OPERATION Torque wrenches and hoses are not always completely filled with oil when new. For safe and efficient operation the air must be removed from the system. The following should be carried out with a torque wrench connected to the pump, but not fitted on a bolt. The torque wrench must be located at a lower level than the pump. Connect the pump to an air supply. (The motor will not start until a pendant button is pressed.) Adjust the air regulator control (13) to between 5 and 7 bar, as shown on the air pressure gauge (10). Press and hold the advance button on the control pendant. The motor will start and the torque wrench should advance until it reaches the end of its stroke and then the pressure on gauge (5) should start to build up. If the torque wrench does not advance and pressure is shown on the gauge then it may already be fully advanced. If there is no pressure registering on the gauge, turn the adjustable pressure relief valve knob (6) clockwise until pressure shows on the gauge. If the tool retracts, then swap the pendant signal hoses (11). Press and hold the retract button on the control pendant. The torque wrench should retract until it reaches the end of its stroke and the pressure should build up to a maximum of 120 bar. If the pressure goes above 120 bar then the tool is connected the wrong way round. This must be corrected before proceeding otherwise tool damage or personal injury may result. Repeat this advance and retract cycle at least 10 times to purge air from the system. Page 3 of 8

NB if very long hoses are employed (greater than 5 m) then this method will not be totally effective. Consult your Hi-Force distributor for advice on pre-filling hoses. Press and hold the advance button again and whilst doing so adjust the relief valve by turning the knob clockwise until maximum working pressure (700 bar) is reached. Reduce the pressure by turning the knob anticlockwise. The pressure setting can be locked at the desired value by tightening the wing nut under the adjusting knob clockwise. The pump is now ready for use Refer to torque wrench operating instructions for detailed information on the correct operation of these tools. MAINTENANCE The oil level in the reservoir should not be allowed to fall below the minimum level during use. Keep the reservoir topped up with Hi-Force HFO46 oil. If the oil level does fall below the minimum level then air may be drawn into the system and cause erratic operation. Regularly inspect the air hoses for damage. Oil should be replaced after approximately 500 working hours. Drain oil via drain plug (9) Add viscosity grade 22 air line lubrication oil to reservoir (15) as required. Do not use hydraulic oil. Drain water from air regulator filter bowl as required by depressing the valve on the bottom of the bowl. TROUBLE SHOOTING These pumps should be repaired only by authorised Hi-Force repair centres. The following table gives possible causes and remedies for common problems. PROBLEM Tool will only reach 120bar in advance mode, but higher in retract mode. Tool advances when retract button is pressed and vice versa. Motor stalls before 700 bar is reached. Motor runs slowly POSSIBLE CAUSE Tool incorrectly connected. Swap hose connections at tool. Pendant signal hoses wrongly connected swap hoses at connections (11) Low supply pressure or insufficient air flow. Low supply pressure or insufficient air flow. Page 4 of 8

NOTE:- Page 5 of 8

NOTE:- Page 6 of 8

NOTE:- Page 7 of 8

UK Head Office: Hi-Force Limited Prospect Way, Daventry, Northants, NN11 8PL, United Kingdom,..Tel: +44 1327 301 000..Fax: +44 1327 706 555 Email: Hi-Force Regional Offices: daventry@hi-force.com Hi-Force Regional Offices: Hi-Force Australia Pty. Ltd Rockingham Australia Tel: +61 8 9591 1288 Email: australia@hi-force.com Hi-Force Hydraulics (Asia) S.B Selangor Malaysia Tel: +603 5569 4209 Email: malaysia@hi-force.com Hi-Force Hydraulics (Pty) Ltd Midrand South Africa Tel: +27 11 314 0555 Email: south.africa@hi-force.com Hi-Force Hydraulics Abu Dhabi United Arab Emirates Tel: +971 2 551 3100 Email: abu.dhabi@hi-force.com Hi-Force Caspian Baku Azerbaijan Tel: +994 12 447 4100 Email: baku@hi-force.com Hi-Force Nederland BV Strijen Netherlands Tel: +31 78 6745488 Email: holland@hi-force.com Hi-Force FZCO Dubai United Arab Emirates Tel: +971 4 815 0600 Email: dubai@hi-force.com Hi-Force Hydraulic Equipment (Shanghai) Ltd. Co. Shanghai, China Tel: +86 21 6697 3010 Email: china@hi-force.com GLOBAL BRAND.LOCAL SERVICE. www.hi-force.com Page 8 of 8