FMAC Sine FMAC Sine DCL

Similar documents
Efficient EMC Solutions

Power Quality Increased Reliability. Components

VLT 2000 Series. How to size your VLT

High-performance submersible pressure transmitter For level measurement Model LH-10

Prewired position switches FA series

Gas density monitor With integrated transmitter Model GDM-100-TI

Position switches FP series

High-performance submersible pressure transmitter For level measurement Model LH-10

TeSys protection components

WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Pressure Measurement Single-range transmitters for general applications

Applications. What moves your world

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

X2 Metallized Polypropylene Film Capacitor JFV

Consumer Products Services Germany GmbH Türkheim Germany

Guidelines to the standard IEC60601

AMS 2710 PCB pressure sensor module with V output

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

High-performance submersible pressure transmitter For level measurement Model LH-20

Differential pressure controls, Type MP 54, 55 and 55A

Relative pressure transmitter type 520

High-performance submersible pressure transmitter For level measurement Model LH-20

SENSORS Pressure CALDARO

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

SITRANS P measuring instruments for pressure

Certificate of compliance

X2 Metallized Polypropylene Film Capacitor JFV

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

UL TEST REPORT AND PROCEDURE

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Meta-MEC Manual Motor Starters

Differential Pressure Control Types MP 54, MP 55 and MP 55A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Prewired position switches FA series

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

EX-RECESSED CEILING LIGHT FITTINGS

Quick Reference Guide Power Series Switches

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Meta-MEC Manual Motor Starters

Junction Boxes Series 8118

Pressure switches for air and water CS

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

High-performance submersible pressure transmitter For level measurement Model LH-20

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Differential pressure switch MP 54, MP 55 and MP 55A

[Instruments for vacuum measurement, checking and adjustment] 3

Input Systems. schurter.com/input-systems. Touchscreen Lösungen solutions Kapazitive Capacitive Schaltelemente Folientastaturen.

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

ibridge and ibridge Ultra

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

JUMO dtrans p30 Pressure Transmitter

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

OPTIBAR P 1010 C Technical Datasheet

Installation and Operation Manual

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Monitoring device NTS 30

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision

TERMINAL BLOCK SUMMARY

Miniature controls. Contactors. Overload relays. Starters. Control relays

EPRB-2 Pressure Transducer

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Precision pressure sensor Basic version Model CPT6020

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Proportional pressure regulators VPPE

OTL Universal terminals

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Tolerance code. Lead space

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Circuit breakers PR 60

Installation, use and maintenance instructions. Gas burner (5)

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Pressure Measurement Single-range transmitters for general applications

SPECIFICATION FOR APPROVAL

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

RoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator

Relative pressure switch type 521

Manual Power relay SR853

Tightness controls TC 1 3 and TC 4

3-phase Line Reactor to reduce mains disturbances

ChromaLit Extruded Linear

RELAY PRODUCT GUIDE CONTENTS

VMR VMR-OTN VMR 6 bar

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Key Comparison of Safety Requirements in Europe, North America and Australia for Electronic Products

Versatile Filtered Power Entry Module

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Electronic gas volume corrector model DGVC-04

Conductor Bushings Series 8174

Transcription:

emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL

-Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include insulated safety screw terminals - Enhancement of the system efficiency Applications - Optimized for long motor cables (up to 2 m) and operation under full load - Frequency converters in uninterruptible power supplies, elevators, heating-, ventilating- and air conditioning-systems, traction and conveyer systems References Product Information: http://www.schurter.com/product_information Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs CHINA-RoHS: http://www.schurter.com/china_rohs Stock-Check: http://www.schurter.com/stockcheck Technical Data Rated Current 4-16 A @ Ta 4 C Rated voltage 5/288 VAC; 5/6 Hz Approval for 4-16 A @ Ta C / 5/288 VAC; 5 Hz Overload Current 1.5 x Ir for 1 minute, per hour Dielectric Strength for 48 VAC 2.5 kvdc between L-L 1.1 kvdc between L-PE Test voltage (2 sec) Weight 9-22 kg Material: Housing Metal Sealing Compound UL 94V-2 Mounting Screw-on mounting on chassis, from top Terminal Screw Clamp Operating Temperature [ C] -25 C to 1 C Climatic Category 25/1/21 acc. to IEC 668-1 Degree of Protection IP 2 acc. to IEC 6529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 6114

www.schurter.com/pg8 FMAC SINE Dimensions Case 2K max. 5 (27) max. 9 (24) (2) (19) (1) 29 2 6.5 ±. max. 15 (19.5) 44±. 4mm 2 ;.5-,6 Nm 1) Inverter 2) Motor Case 2L max. 5 (27) max. 9 (24) (2) (19) (1) 29 2 6.5 ±. max. 18 (19.5) 44±. 4mm 2 ;.5-,6 Nm 1) Inverter 2) Motor

-Phase Filters Case 2M max. 5 (27) max. 9 (24) (2) (19) (1) 29 2 8.6 ±. max. 215 (174.5) 4mm 2 ;.5-,6 Nm 44±. 1) Inverter 2) Motor Case 2N max. 295 (26) max. 145 (2) () () 28 2 8.7 ±. max. 19 (149.5) 1mm 2 ; 1.5-1,8 Nm 15 ±. 1) Inverter 2) Motor

www.schurter.com/pg8 FMAC SINE Diagrams F1 F2 F A) B) M A) B) U U ) L1 L2 L PE I I 1) Inverter 2) Sine wave output filter ) Motor Variants Rated Current Rated voltage Switching frequency Motor frequency Rated motor power Motor cable lenght DC resistance Total power loss Weight Housing Order Number [A] [VAC] [khz] [khz] [kw] [m] [mω] [W] [kg] 4 5/288 2...2...2 1.5 2m 4 7 9 2K FMAC-S2K-462-A 8 5/288 2...2...2. 2m 18 12 12 2L FMAC-S2L-862-A 12 5/288 2...2...2 5.5 2m 12 18 15 2M FMAC-S2M-1262-A 16 5/288 2...2...2 7.5 2m 17 44 22 2N FMAC-S2N-1662-A Packaging unit 1 Pcs > Sine Wave Output Filters to Increase Motor Service Life The SCHURTER Sine Wave Filters series FMAC SINE and FMAC SINE DCL are designed to convert output voltage wave forms produced by PWM frequency converters into low distortion sine wave forms for motor drive and power transformation applications. Sine Wave Filters are suited to a wide variety of applications including frequency converters in uninterruptible power supplies, elevators, heating-, ventilating- and air conditioning systems, traction and conveyer systems. The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.

-Phase Filters Sine wave output filter with a voltage dc link Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Enhancement of the system efficiency Technical Data Rated Current 4-16 A @ Ta 4 C Rated voltage 5/288 VAC; 5/6 Hz Approval for 4-16 A @ Ta C / 5/288 VAC; 5 Hz Overload Current 1.5 x Ir for 1 minute, per hour Dielectric Strength for 48 VAC 2.5 kvdc between L-L 1.1 kvdc between L-PE Test voltage (2 sec) Weight 16-24 kg Material: Housing Metal Sealing Compound UL 94V-2 Applications - Optimized for long motor cables (up to 1 m) and operation under full load - Equipped with voltage connection to converter dc link circuit for best results - Frequency converters in uninterruptible power supplies, elevators, heating-, ventilating- and air conditioning-systems, traction and conveyer systems - Cost saving technologie, increase of motor life time, deployment of flexible lightweight unshielded instead of expensive shielded motor cables, reduced fitting work References Product Information: http://www.schurter.com/product_information Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs CHINA-RoHS: http://www.schurter.com/china_rohs Stock-Check: http://www.schurter.com/stockcheck Mounting Screw-on mounting on chassis, from top Terminal Screw Clamp Operating Temperature [ C] -25 C to 1 C Climatic Category 25/1/21 acc. to IEC 668-1 Degree of Protection IP 2 acc. to IEC 6529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 6114

FMAC SINE DCL www.schurter.com/pg8 Dimensions Case 2G max. 5 max. 9 (19) (2) (28) 7±1 4 7±5 2±5 (19.5) 1±5 ) max. 15 (112) max. 9 5) (11) 4) 1.5 mm 2 7 2 M4x16; 1.5-2 Nm 8) 6.5 ±. 6) 4mm 2 ;.5-,6 Nm 44 ±. 7) (x) 1.5 mm 2 1) Inverter 2) Motor ) Shield 4) Shielded cable 5) Endsleeves 6) Ground 7) Shieldes cable 8) Operation Mode Case IB max. 5 max. 9 (19) (2) (28) 7±1 4 7±5 2±5 1±5 (19.5) ) max. 18 (142) max. 9 5) (11) 4) 1.5 mm 2 7 2 M4x16; 1.5-2 Nm 8) 8.6 ±. 6) 4mm 2 ;.5-,6 Nm 44 ±. 7) (x) 1.5 mm 2 1) Inverter 2) Motor ) Shield 4) Shielded cable 5) Endsleeves 6) Ground 7) Shieldes cable 8) Operation Mode

-Phase Filters Case 2H max. 5 max. 9 (19) (2) (28) 7±1 4 7±5 2±5 1±5 (174.5) ) max. 215 (177) max. 9 5) (11) 4) 1.5 mm 2 7 2 M4x16; 1.5-2 Nm 8) 8.7 ±. 6) 4mm 2 ;.5-,6 Nm 44 ±. 7) (x) 1.5 mm 2 1) Inverter 2) Motor ) Shield 4) Shielded cable 5) Endsleeves 6) Ground 7) Shieldes cable 8) Operation Mode Case 2I max. 1 max. 14 (8) (2) (45) 7±1 4 55 7±5 2±5 (15) 1±5 (18) ) max. 2 (18) max. 5 2 5) (11) 4) 2.5 mm 2 M4x16; 1.5-2 Nm 8) 8.7 ±. 6) 1mm 2 ; 1.5-1.8 Nm 95 ±. 7) (x) 2.5 mm 2 1) Inverter 2) Motor ) Shield 4) Shielded cable 5) Endsleeves 6) Ground 7) Shieldes cable 8) Operation Mode

FMAC SINE DCL www.schurter.com/pg8 Diagrams F1 F2 F 1) A) B) M A) B) U U 2) ) 4) 5) L1 L2 L PE I I Note:The inverter switching frequency must lie within the range from 2 to 2kHz. A switching frequency below or above the mentioned range will result in poor performances. Sine wave output filters with dc-link produce leakage currents. These leakage currents could, in combination with certain OEM inverter types, disturb overall system performance, causing a "over current or short to earth" error message on the inverter. For such cases Schurter suggests the following three solutions or a combination of each:1) Increasing the switching frequency of the inverter (drawback: increased power loss in the inverter) 2) Activating the low leakage sine wave output filter operation mode by removing the factory set detachable screw (drawback: light increase of the leakage current in the motor) ) Connecting a ground wire choke type DEH in the inverters earth connection (drawback: additional component) 1) Inverter 2) Ground choke ) DC-Link 4) Sine wave output filter 5) Motor Variants Rated Current Rated voltage Switching frequency Motor frequency Rated motor power Motor cable lenght DC resistance Total power loss Weight Housing Order Number [A] [VAC] [khz] [khz] [kw] [m] [mω] [W] [kg] 8 5/288 2...2...2. <= 1 22 14 16 IB FMAC-SIB-862 4 5/288 2...2...2 1.5 <= 1 45 8 1 2G FMAC-S2G-462 12 5/288 2...2...2 5.5 <= 1 14 2 2 2H FMAC-S2H-1262 16 5/288 2...2...2 7.5 <= 1 11 28 24 2I FMAC-S2I-1662 Packaging unit 1 Pcs > Best Products Worldwide "Both, now and in the future, our customers are guaranteed the best products world-wide; products which perfectly correspond to their individual needs. SCHURTER is permanently committed to the excellent quality of its products and business practices which are ecologically sound." Hans-Rudolf Schurter, Schurter Holding AG The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.

www.schurter.com/emc-service & Services > EMC Services Applying the optimal EMC solution by eliminating interference in electrical systems and equipment. Our Range of Services Feel free to put our EMC competence to the test. We will perform EMC measurements in order to recommend the changes needed to eliminate interference in your appliance. We will build specific samples and provide you with your individual EMC solution. We will oversee your product s life cycle from R&D to mass production. Partnership Success is our permanent incentive. We are used to being innovative to meet challenges in diverse markets. Our experience has shown that the main savings potential in terms of EMC-compliant appliance cost lies in the materials used. Through ingenious filter design, we will achieve optimal performance at a minimal price. The standard products listed below are specially designed to eliminate interference in electrical equipment. - Power entry modules with filter - Single phase line filters - -phase line filters - Chokes EMC products: www.schurter.com/emc New products: www.schurter.com/emc_news Approvals Our products carry all country-specific certification labels such as: UL, CSA, VDE (ENEC1), CCC, Approvals overview: www.schurter.com/approvals SCHURTER offers a variety of products ensuring clean and safe supply of power and ease of use. Project Competence At SCHURTER, more than 5 engineers are dedicated to developing our products and manufacturing systems, using the latest in design and testing tools and systems.

Mass Production SCHURTER guarantees consistently high quality and absolute reliability in each and every one of its products. Our state-of-the-art manufacturing facilities as well as our up-to-date know-how make sure we can fulfill our motto: Clean & Safe Power Ease of Use. Our expertise encompasses injection molding, metalworking, electroplating, assembly with automated manufacturing systems, casing system design and manufacturing, PCB assembly as well as EMC product assembly. Competence: www.schurter.com/competence Measurement Competence SCHURTER will perform all necessary preliminary tests concerning immunity and interference in your electrical systems or equipment. Our EMC competence center is equipped with all the measurement tools necessary and an EMC chamber for measuring line-bound interference. Measurements on Site Upon request we will conduct testing to eliminate interference in electrical equipment using our mobile measurement tools directly on site. SCHURTER offers a mobile measurement service equipped with all necessary tools for line-bound measurements (IEC 61-6- und IEC 61-6-4), allowing various systems or equipment conformity tests to be performed directly at the manufacturer s or user s site. EMC service: www.schurter.com/emc-service Measurement Report for CE Conformity The measurement results will be compiled in an EMC measurement report. This report will serve as proof of CE conformity for line-bound interference. Household, Lighting and Telecom Residential, commercial and light industrial Emission IEC 61-6- (EN 581-1) EN 5514 Household Applications and tools EN 5522 ITE (Information technology equipment) Harmonics (IEC 61--2) Voltage fluctuations (IEC 61--) Immunity IEC 61-6-1 (EN 582-1) IEC 61-4-2 ESD IEC 61-4- HF field IEC 61-4-4 Burst IEC 61-4-5 Surge IEC 61-4-11 Voltage variations Industrial Applications (ISM) Industrial, scientific and medical, high-frequency appliances Emission IEC 61-6-4 (EN 581-2) EN 5511 Harmonics (IEC 61--2) Voltage fluctuations (IEC 61--) Immunity IEC 61-6-2 (EN 582-2) IEC 61-4-2 ESD IEC 61-4- HF field (casing) IEC 61-4-6 HF field (lines) IEC 61-4-4 Burst IEC 61-4-5 Surge IEC 61-4-8 NF magnetic field (only for appliances sensitive to magnetic fields) Sample Service Individual interference problems require the development of special filter solutions. In cooperation with customers, SCHURTER will prepare samples including documentation within an 8 business day turnaround time. Contact Please don t hesitate to contact us, should you need further information. We will gladly make your problems our challenges. SCHURTER endeavors to provide you with the most optimal EMC solution. Contact: www.schurter.com/contact_emc SCHURTER AG Arjan van der Marel Product Manager EMC Phone: ++41 +91 64 7 94 arjan.vandermarel@schurter.ch

COMPONENTS Switzerland SCHURTER AG phone: ++41 +41 69 1 11 contact@schurter.ch Brazil SCHURTER + OKW do Brasil Componentes Eletronicos Ltda. Tel.: ++55 +11 59 info@sob-brasil.com China SCHURTER Electronics Shenzhen Ltd. phone: ++86 755 2994 66 info@schurter.com.cn CHI LICK-SCHURTER Ltd. Hong Kong SAR phone: ++852 248 7798 fuse@chilickschurter.com Czech Republic SCHURTER spol. s.r.o. phone: ++42 +48 92 8 firma@schurter.cz Germany SCHURTER GmbH phone: ++49 +7642 682 info@schurter.de France SCHURTER SA phone: ++ + 252 549 contact@schurter.fr India SCHURTER Electronics (India) Pvt. Ltd. phone: ++91+2667 26475/4 info@schurter.co.in Italy KEVIN-SCHURTER S.p.a phone: ++9 +2 46 511 info@kevin.it Japan SCHURTER K. K. phone: ++81 + 579 5111 info@schurter.co.jp Singapore SCHURTER (S) Pte. Ltd. (APAC HQs) phone: ++65 6291 2111 info@schurter.com.sg Slovakia SCHURTER (SK) s.r.o. phone: ++42 18 59 84 8 Sweden SCHURTER Nordic AB phone: ++46 +8 447 5 6 info@schurter.se UK SCHURTER Ltd. phone: ++44 +124 81 81 sales@schurter.co.uk USA SCHURTER Inc. phone: ++1 +77 66 info@schurterinc.com INPUT SYSTEMS Germany SCHURTER GmbH phone: ++49 +7642 682 info@schurter.de Switzerland SCHURTER Input Systems AG phone: ++41 +56 481 9 info@meierhofer.ch EMS ELECTRONIC MANUFACTURING SERVICES Romania INTERELEKTRONIC SRL phone: ++42 15 8 1 info@interelektronic.ro Switzerland TICOMEL SA phone: ++41 +91 64 44 1 contact@ticomel.ch www.schurter.com fuses connectors circuit breakers input systems emc products 165.564 /.1 / UD