Meditation Trainer. Created by Collin Cunningham. Last updated on :36:45 PM UTC

Similar documents
Experiment B-18 Heart Rate and Coughing

Zombie Tag Game with Circuit Playground Express

Experiment B-43 Respiration Rates

Oxygen Meter User Manual

User Guide. A fully featured heart rhythm feedback game that works with emwave2 and emwave Desktop. Mac and Windows compatible.

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Exercise and Respiration Rate

Grove - Gas Sensor (O2)

Introducing the itapstick: Video Game USB Mouse Stick for Wii Nunchuk Controllers

Respiratory Response to Physiologic Challenges. Evaluation copy

12/07/2016 Grove Gas Sensor(O₂) Wiki

Technology. Using Bluetooth

ECG-Heart Rate Compact Trainer An Awareness Control Stress-Reduction Program Computer-aided Guided Breathing Relaxation Exercises

Timex Ironman Run Trainer Powered by GPS Technology

Technology. Using Bluetooth

Electric Blower Based Portable Emergency Ventilator

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Alternate Nostril Breathing

Getting Started with the LabVIEW Toolkit for LEGO MINDSTORMS NXT

Relaxation And The Body

Silkrip. ORR Computer. Owner s Manual. Silkrip Motorsports LLC. Rev H 4/13/2017 IMPORTANT CHANGE TO SENSOR WIRING! Tom King

Respiration. Figure 22: Schematic representation of the respiratory system

Yoga Story Hour Kit. Yoga for kids is a popular activity these days

Design of Experiments Example: A Two-Way Split-Plot Experiment

LifeBeat should be worn during daytime as well as night time as it can record activity levels as well as sleep patterns.

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Micrio Tester for the Raymarine ST50, ST60, and ST60+ Wind Instruments. Rev 1.1

Video recording setup

Figure 1. A schematic diagram of the human respiratory system.

Beating Heart Simulator: Oral Report 2. Ashley Whiteside Nicole Rice Jacob Bauer

THE MAGIC MILE WILL HELP DETERMINE:

Quick-start Guide. Heart Rate Monitors. Copyright Wireless Motorsport Pty Ltd 2016

Instruction Manual. Auto Inflate Blood Pressure Monitor

PRODUCT MANUAL. Diver-Mobile for Android

Make a Marigram. Overview: Targeted Alaska Grade Level Expectations: Objectives: Materials: Whole Picture: Grades 9-12

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

WEEK #1 44 MILES MONDAY, JULY 15, 2014 DAY OFF

Lung Volumes and Capacities

ATOC Meteorological Tower (6 meter-4 level) Guide

Lung Volumes and Capacities

Manual of Procedures for DLCO. ARIC Exam 5

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

AUTO PUMP STATUS CENTER

Boyle s Law: Pressure-Volume Relationship in Gases

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

THE VETSPECS VSM7 USER S MANUAL VETERINARY DIGITAL VITAL SIGNS MONITOR ECG/BLOOD PRESSURE SCREENING SYSTEM - 1 -

Experiment HS-2: Breathing and Gravity

Overview. The user must follow the instructions below.

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Instructions. Table of Contents

For use with version or later

In addition to reading this assignment, also read Appendices A and B.

RM-80 respiration monitor

Coastal Amusements 1935 Swarthmore Ave. Lakewood NJ Tel: (732) Fax: (732)

What to Expect at Your First FTC Tournament. Eric Grajales Mike Nicolai September 17, 2011

For use with version 6.1 or later

Exploring the Properties of Gases

1. Photosynthesis and Light. See real-time evidence that light causes photosynthesis to occur!

[XACT INTEGRATION] The Race Director. Xact Integration

WORKING WITH SCATT A GUIDE TO GETTING THE MOST OUT OF YOUR SCATT TRAINER

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

Respiration Lab Instructions

Hyperventilation. This leaflet is a continuation of the relaxation pack which looks at anxiety and panic attacks

Previous Release Notes

Introduction to Breathing Script

HEART RHYTHM SCANNER Special Edition

Code Blue III Simulators. ALS and Emergency Care Simulators

Boyle s Law: Pressure-Volume. Relationship in Gases

Science in Sport. 106 How fast is the wind speed? Read. Count/Tachometer Any EASYSENSE. Sensors: Loggers: Logging time: EasyLog

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

PAPR : Powered Air Purifying Respirator. Sync01VP3 Q&A. Index

AMS 2710 PCB pressure sensor module with V output

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

SKAGIT COUNTY AUTOMATED EXTERNAL DEFIBRILLATOR [AED] POLICY

Model 6202 Reduced Oxygen Breathing Device 2

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

DDR Dive Data Recorder Manual - Rel /12

Medical Ventilators. Ryan Sanford Daniel Tajik

Guidelines. Milan Special School District. Automated External Defibrillator (AED) Program

Balancing Active and Receptive Energies: The Practice of Nadi Shodanam

Air Ball! Evaluation copy

RESTORATION OF HEART RHYTHM DURING FIBRILLATION BY A CONDENSER DISCHARGE

boso Germany Do you? Premium quality essgeräte für die Selbstmessung I use equipment of BOSCH + SOHN to measure blood pressure.

ScienceScope Ltd, 12 Coombend, Radstock, BA3 3AJ Tel: Fax:

1. Your anchor: Easy sitting, deep exhales (Sukhasana)

TR Electronic Pressure Regulator. User s Manual

BUYER S GUIDE AQUAlogger 530WTD

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

NEULOG OXYGEN LOGGER SENSOR GUIDE

4/16/18. Basic Emotional Energetics. Basic Energetics. Image Copyright 2010 by Steven Horne

Transcription:

Meditation Trainer Created by Collin Cunningham Last updated on 2018-03-26 09:36:45 PM UTC

Guide Contents Guide Contents Overview What is HRV? What you'll need: Wiring Making connections Software Setup Code Usage Using the LED Display Breathe 2 3 3 4 6 6 9 9 9 10 10 11 Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 2 of 11

Overview This project uses an Adafruit Circuit Playground Classic board along with a Pulse Sensor Amped to measure changes in heart rate variability (HRV). Because fewer changes in heart rate variability are associated with healthy, relaxed states, these measurements can be used as a way to reduce anxiety and increase meditative calm. What is HRV? We normally think about our pulse as being a relatively constant value measured in beats per minute, but in reality, the interval between beats (inter-beat interval or IBI) usually fluctuates quite a bit. This variance between heart beat intervals is known as heart rate variability (HRV). When breathing is slowed to a rate of ~12 cycles per minute (1 cycle = 1 inhale + 1 exhale), respiratory & cardiac rhythms tend to fall in sync with one another and HRV fluctuations become less erratic and more amplified resembling a sine wave. This synchronization is considered indicative of a relaxed, healthy state of being where anxiety is reduced and clear, calm thinking is enhanced. So, if we measured and graphed the time between heartbeats of a stressed person, it might look something like this: Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 3 of 11

And the same type of measurement made on a zen master might look something like this: The goal of this project is to create a device which will help someone achieve a smoother, sinusoidal HRV pattern like the one above. You can read more about HRV, coherence, and related topics here: Wikipedia Coherence.com HeartMath Disclaimer: This is not a medical device and should not be used for any official diagnostic or otherwise lifedependent medical purposes! What you'll need: To build the relaxation trainer you'll only need the following: Circuit Playground Classic Pulse Sensor Amped Alligator Clips -or- Soldering iron & solder Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 4 of 11

Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 5 of 11

Wiring Wiring for this project is simple, there are only three connections which need to be made between the Pulse Sensor and Circuit Playground board: Pulse Sensor Black wire to Circuit Playground GND Pulse Sensor Red wire to Circuit Playground VBATT Pulse Sensor Purple wire to Circuit Playground #6 The Circuit Playground can be powered by either USB or the JST battery connector. Making connections If you'd just like to experiment with or test this project, you can easily make the necessary connections using three alligator clips. Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 6 of 11

For a more permanent approach, you can securely solder the connections. Clip the male header pins from the pulse sensor leads and then strip and tin each lead before soldering to the terminals on the Circuit Playground board. Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 7 of 11

Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 8 of 11

Software This project was written for use with Circuit Playground Classic boards. The code does not support Circuit Playground Express at this time. Setup If this is the first time you're programming a Circuit Playground board, you'll need to set up the Arduino IDE with support for it. Follow the instructions found here, and come back once you have everything working. Code The code we'll be using is based on the example sketch written for the Pulse Sensor Amped. Code has been added to control the Circuit Playground's built-in Neopixel LEDs and record changes in interbeat interval values (IBI), and calculate a relaxation rating based on how often the IBI plots change direction. Download the code from the project's GitHib repository here: Click to download Meditation Trainer https://adafru.it/qxb Unzip the downloaded archive and rename the folder named "Meditation_Trainer-master" to "Meditation_Trainer". Inside that folder, you'll find a file named "Meditation_Trainer.ino" - open it in the Arduino IDE and upload it to your Circuit Playground board. Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 9 of 11

Usage The pulse sensor can be attached to either the ear lobe or fingertip. In my experience, attaching the sensor to the fingertip with the included velcro strip provides the most reliable reading. Once the sensor is secured, connect the Circuit Playground board to power via the USB or battery connector and you should see the two LEDs near the USB jack begin to flash in time with your pulse. If the LEDs don't light up, try readjusting the sensor until you have a secure fit. Using the LED Display Adafruit Industries https://learn.adafruit.com/heart-rate-variability-sensor Page 10 of 11

Breath Pacer: Eight of the neopixel LEDs on the Circuit Playground are used to display a breath pacer which is helpful for ideal timing of inhale/exhale cycles. Breath in as the LEDs pulse toward one side, and breath out as they move back to the other side. Pulse/Relaxation: The remaining two LEDs flash with each pulse detected and their color indicates a basic HRV rating which roughly translates to the user's level of relaxation: red = low relaxation blue = moderate relaxation green = high relaxation Breathe Sit in a comfortable position and use the breath pacer to guide your breathing - breath in as it moves toward one side, and begin to breath out when it changes direction. As you continue to breathe at this slow deliberate rate, you should notice the pulse LEDs change color to indicate smoother changes in heart rate variability and hopefully help you achieve a more deeply relaxed state. Though the relaxation indicator is helpful, the most useful functionality here is actually the breath pacer. One of the most common techniques for achieving a meditative state is focussed breathing. Paying conscious attention to your own breathing is a simple but highly effective way to increase mindfulness. Adafruit Industries Last Updated: 2018-03-26 09:36:44 PM UTC Page 11 of 11