Breathing Air Compressor Bid Specification

Similar documents
Calera Fire Department Breathing Air System Technical Specifications

BREATHING AIR SYSTEMS HIGH-PERFORMANCE PRODUCTS FROM SCOTT

BREATHING AIR SYSTEMS HIGH-PERFORMANCE PRODUCTS FROM SCOTT

Work Horses of the Breathing Air Industry

Mobile Breathing Air Systems

RAM 4021-DPX Operation Manual

JORDAIR/BAUER Service Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021 Operation Manual

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

RAM Operation Manual

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society


RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Operating Manual. Model BAC-30RT30/BAC-30DC

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

High Pressure Breathing Air Compressors

Marschalk Model # 94000

accidents which arise due to non-observance of these instructions and the safety information herein.

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Breathing Air Solutions. We ve Got Your Back

OPERATOR, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL COMPRESSOR, RECIPROCATING, AIR; 15 CFM, 175 PSI;

B-Series. breathing air systems flow capacity: scfm

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AutoDrill s OUTSTANDING FEATURES

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Instruction Manual for

FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK

Unit 24: Applications of Pneumatics and Hydraulics

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

OPERATION MANUAL NTF-15

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

AA-75CF Portable Air Compressor NSN:

take a deep breath... Dependable high quality breathing air compressors

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Pneumatic high-pressure controller Model CPC7000

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Linde Cryogenics. Helium Recovery Systems.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Air Amplifiers & SYSTEMS

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

User Instruction Manual

BUBBLER CONTROL SYSTEM

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Universal Valve Company Inc

Universal Valve Company Inc

Model Series 62 Constant Differential Relay

CAPITAL CONTROLS SERIES NXT3000

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

OPERATION MANUAL NTF-60 Plus

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

PC1131 Electric Air Compressor

Goulds 3296 EZMAG. Chemical Process Pump

NGP-250/500 Nitrogen Generator Quick Start Guide

Series 58 SAFETY VALVES 312

TECHNICAL DATA. Trimpac 257a. September 16, 2013

MODEL NUMBER: P PORTABLE COMPRESSOR

Memo. Shelley Cohen. From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News

PAINTBALL

CNG FILLING STATIONS

Niltox Breathing Air Purifier Range

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

PRODUCT OPERATING MANUAL

SYSTEMS SERVICE TRAINING WORLDWIDE OFFSHORE SOLUTIONS. From the High Pressure Experts

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Product Range. High performance and economic high pressure solutions Made in Germany

200 PSI HIGH-FLOW AIR SOURCE KIT

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

MEDICAL EQUIPMENT CATALOG

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Operating Instructions Part No

TECHNICAL DATA. Trimpac 256a. October 31, 2013

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

with O 2 Controller Instruction Manual

MANUAL BE SERIES Test Benches

Aquavar SOLO 2 Frequently Asked Questions

A TECHNICAL REFERENCE

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Compressors for Paintball and Air Guns Catalog. The most convenient, efficient and effective way to fill your high pressure tanks.

TECHNICAL DATA. Page 1 of 12

GAS FUEL VALVE FORM AGV5 OM 8-03

Transcription:

Breathing Air Compressor Bid Specification The system shall be designed as a complete breathing air package, made up of an air compressor module, air storage and breathing apparatus cylinder charge station. This document describes the minimum requirements for a complete breathing air compressor system. The system shall be modular and capable of being supplied as specified herein. The ability to separate the compressor module from the bottle charge station is for operator safety. EXCEPTIONS Any exceptions to the specification shall be submitted with the BID PROPOSAL FORM. WARRANTY The equipment supplied shall be guaranteed to be new, of current design, and free of all defects in material and workmanship for a period of five years or 1000 hours, whichever is sooner, based on prescribed service and maintenance. AFTER SALES SERVICE Support and service shall be available from a factory authorized local service center. The service center shall be capable of performing all maintenance and repairs at the site of the compressor installation. Service technicians shall be factory trained and authorized by the equipment s manufacturer. Under normal circumstances, qualified service technicians shall be capable of responding to requests for service within 48 Hours. 10 HP AIR COMPRESSOR 1. Charge rate (12 scfm / 340 lpm) 2. 1080RPM 3. Electric ODP motor shall be 10 HP, three phase 208, 230, or 460 volts at 60hz; or 380, or 450 volts at 50hz AIR COMPRESSOR CONSTRUCTION 1. Compressor shall be a 5 stage, air-cooled reciprocating compressor which is belt driven by an induction motor 2. Minimum pressure continuous duty shall be 7500 psi / 517.1 bar 3. Delivery of high pressure air shall be temperature only slightly above the ambient air temperature (Approximately 15 F (9.4 C) above ambient) Page 1 of 8

4. Reduction of moisture content and impurity levels in the air stream issuing from the last stage separator to CGA Grade E criteria by absorption, chemical reaction, and filtration in the purification subsystem. 5. Oil mist lubrication for all cylinders, main, big, and small end rod bearings 6. Programmable auto condensate drain system (ACD) shall have the capability to monitor the function of each stage drain valve and alert the operator of any malfunctioning stage drain. 7. Multi-valve dump block design for ease of service consisting of four piston-type valves 8. Oil change only required every 200 hours 9. Auto condensate drain system service only required at 500 hours 10. 12-blade high-velocity fan for cooling efficiency 11. Serviceable and rebuild able multi-ported reed valves & flat plates 12. Compressor shall have sound dampening doors and interior sound dampening material 13. Cylinders shall have finned aluminum heads for superior heat dissipation 14. Flywheel shall be precision-balanced and fan-bladed for excellent cooling capacity 15. Enclosed all metal fan-blade guard 16. Modular construction to fit through a 36 door opening 17. Compressor shall utilize a pressurized oil lubrication system 18. Compressor shall have pressure transducers for digital display of inter-stage, final pressures and oil pressure 19. Compressor shall have incorporate intercoolers and relief valves for all stages, and condensate traps after 2nd, 3rd, 4th, & 5th stage of compression. 20. Compressor and electric motor shall be mounted in a horizontal format with an adjusting belt system. 21. Radial layout for reduced vibration 22. Stainless steel valves assemblies on all stages for long wear, excellent heat resistance and dissipation 23. Pressurized oil crankshaft 24. Ductile iron connecting rods for high strength. 25. Needle bearings on connecting rods for added durability and reliability 26. Condensate container sensor alarms at ¾ full and automatically shuts down compressor when full Page 2 of 8

PURIFICATION SYSTEM 1. The purification system shall consist of a mechanical oil/moisture separator and either 2, 3, or 4 chemical purification chambers. The chambers shall be designed to conform to the CRN & ASME code for Unified Pressure Vessels. 2. Purification chambers shall be constructed in aluminum alloy 6061 T6 as its anti-corrosive properties exceed all other chamber materials. 3. Under ideal conditions the purification system shall process a maximum of 60,000 scf of air per cartridge set (2 pieces) for 10 HP compressor. 4. Purified air shall be measured by the actual weight of Molecular Sieve. Electronic Dew Point (DP) detection shall not be used as a means to claim extended chemical cartridge life. 5. CO and dew point sensors shall not be installed in the purification chamber. 6. Sensors shall be installed downstream of all chambers so the sampled air is representative of that delivered to the B.A. cylinders. 7. The purification system shall have the following minimum ratings: 8. 7000 PSI working pressure. 9. 4 to 1 safety factor. 10. 10 SCFM minimum flow capacity per purification chamber. COMPUTERIZED CONTROL AND MONITORING SYSTEM All significant functions of the system shall be monitored and controlled by a microprocessor controller. The operational status will be presented on an enunciator panel. In the event of an out-of-tolerance condition, the controller will alarm and stop the compressor. The status and/or cause will be indicated on the enunciator panel. All accumulated times on all significant time sensitive functions will be recorded and displayed on command. The system will be touch screen enabled and user access controlled via RFID, numeric passcode or some other method. The system shall have the following capabilities at a minimum: 1. Touch screen control 2. User access control via RFID, touchscreen key pad, and/or biometrics 3. Cloud integration 4. Tracking and recording of compressor operation and operating parameters 5. Digital pressure gauges 6. Read/write BA cylinder RFID capability Page 3 of 8

7. The control & monitoring system can be mounted in the charge station when a charge station is purchased with the compressor. If the compressor is ordered without a charge station the control & monitoring system shall be a separate wall mount system. CONTROLLER FUNCTIONS / PARAMETERS MONITORED AND CONTROLLED 1. COMPRESSOR ASSEMBLY Compressor start/stop (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Discharge air pressure (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Programmable Auto Condensate Drain control cycle drain function (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Auto Drain/Cool Down Cycle ** (on each shutdown, pressure switch deactivation or Stop button) Oil temperature and pressure (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Display automatic service alerts for auto condensate drain, oil, air sample, CO calibration and purifier elements. Multi-level user access control for security and safety. Downloadable history for diagnostic and performance evaluation. 2. PURIFICATION SYSTEM Dew Point monitoring/control (continuous monitoring) (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Carbon monoxide monitoring/control (continuous monitoring) (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Auto condensate drain control (advise normal/alarm abnormal condition, auto shutdown if parameters exceeded) Purge control, dumps the air exiting the purifier in order to clear up temporary alarm conditions (advise status normal, halts any cylinder filing until alarm has been remedied) 3. MISCELLANOUS Total time on compressor assembly from manufacture date (advise time on command) Time remaining until compressor service (re-settable, advise time on command) Time remaining until next purification cartridge change (re-settable, advise time on command) Time on DP monitor cell (re-settable, advise time on command) Time on CO monitor cell (re-settable, advise time on command) Automatic calibration notification of CO monitors (advise procedure on command) Current compressor run time each session Page 4 of 8

4. ALARMS (AUDIO/VISUAL) High discharge air temperature - with automatic compressor STOP, OVERRIDEABLE with a MAXIMUM upper limit, not OVERRIDEABLE. The upper limit is factory set. High discharge air carbon monoxide - with automatic compressor STOP, OVERRIDEABLE with a MAXIMUM upper limit of 30 PPM not OVERRIDEABLE. OVERRIDE only used in an extreme emergency to SAVE A LIFE. High discharge air moisture (dew point) - with a WARN to advise a pending filter (purification cartridge) change; an ALARM with automatic compressor STOP, OVERRIDEABLE with a MAX upper limit factory set at a safe condition. OVERRIDE only used in an extreme emergency to SAVE A LIFE. Low oil level and/or pressure - with automatic compressor STOP - OVERRIDEABLE. 5. SPECIAL FEATURES AND CONTROLS Prolonged run time control. Will stop the compressor assembly when pre-determined continuous run time has been exceeded. An audio/visual alarm is presented on the abnormal condition. RESET is required. Time delay for false alarm recognition. Preprogrammed to prevent false alarms from stopping the compressor or initial system setup and on purifier cartridge change. Demand Control **(In Automatic mode) Emergency Stop control mounted on the main control panel. 6. DISPLAY Final Output Pressure (0-10,000 psi) Discharge Air Temperature Oil Level/Pressure Dew Point Level up to +30 F, down to -100 F Carbon Monoxide Level 0 to 200 PPM Timing Functions Hours and Minutes, calendar date Cylinder fill data - cylinder serial number, date of last fill, hydro date, last filled by user, pressure, duration Compressor inter-stage pressures Compressor 5th stage pressure 7. MISCELANOUS Door Switch The controller shall be wired for two door switches. When these switches are activated by the door being open when the system is running, the controller shall display an error message and the compressor shall go into a cool-down cycle and then shut down. Page 5 of 8

Demand Control The compressor will automatically respond to air demand, keeping the air receivers at optimum pressure. Cool Down System The system shall have the capability of dumping all mechanical moisture traps at least every fifteen (15) minutes during compressor operation. Prior to shutdown, manually or automatically, it shall open and unload all moisture drain valves. It shall run for two to five minutes in order to cool and dry completely purging the system of all accumulated water and oil vapor. CONTAINMENT FRAGMENTATION SHIELD 1. The charge system shall be a separate module. It shall be designed to safely and efficiently recharge breathing apparatus cylinders (BACs) in a protective containment chamber that will contain all fragments in the event of BAC failure. The resulting air blast shall be vented in a harmless direction such that any resultant air or particle flow will not cause injury or collateral damage to persons or property. The containment chamber must have been tested to contain a 75 minute (111 cu ft) BAC for maximum safety per NFPA 1901. 2. The design of the system shall be such that: one or two BACs are charged within the chamber while one or two BACs are attached and made ready on the outside of the chamber. When the first set of BACs are charged, they shall be rotated out of the chamber as the next set of BAC s are ready then are rotated into the chamber. Once the locks are engaged, the BACs automatically begin filling. - OR - four BACS can be charged can be charged within the chamber at the same time. Once the locks are engaged, the BACs automatically begin filling. 3. The charge adapters shall be the rigid-fast-attach type. The charge adapters shall be mounted 38 inches plus or minus four inches above ground/floor level, to provide an efficient ergonomic operation. 4. The device shall contain safety interlocks such that if the chamber is not closed and locked, air will not flow into the BACs. The chamber shall automatically lock and unlock by the operation of a single actuation lever. BAC charging shall be accomplished by presetting the air flow-control valve and pressure regulator to the required flow and air pressure and engaging the locks. 5. The control panel shall contain safety pressure gauges for air from the compressor, the air storage system, and the BACs being charged. Manual bleed valves shall be integrated into the charging circuit to provide a rapid and safe BAC disconnect. Page 6 of 8

6. An adjustable pressure regulator shall be provided to select the charge pressure for automatic BAC recharging. 7. Safety relief valve shall be incorporated to prevent over charging high pressure BACs. The system shall come with a 6000psi in 6000 psi maximum out fill pressure regulator. 8. A Full System Pressure outlet port shall be provided at the rear of the control panel for additional devices to be added at any time. PERFORMANCE This performance is based on charging a 30 minute, 4500 PSI, breathing air cylinder (BAC), from 0 to 4500 PSI at a rate not to exceed a pressure rise of 1500 PSI per minute (recommended by all BAC manufacturers). This rate will require three minutes to fill the BACs. Result must be 100 cylinders completely charged in 2 hours and 34 minutes. This performance analysis shall include the necessary manipulations that are normal for that charge station. Mathematical computation of the compressor charge rate alone is not acceptable. SMART FILL TECHNOLOGY/AUTO CASCADE SYSTEM System shall have a fully automatic changing, auto cascade, auto flow system. The system shall automatically cascade and control the flow rate of filling the SCBA. With systems that have RFID technology the system will automatically set pressure. CALIBRATION KIT FOR CARBON MONOXIDE MONITOR Calibration Kit shall include: A calibration regulator and connection hose assembly, 1 20PPM calibration gas cylinder and 1 Zero PPM calibration gas cylinder with Material Safety Data Sheets for both. Note: The calibration gas cylinder s volume shall be enough for a minimum of twelve calibrations when used according to the instructions provided. Complete instructions for proper calibration and a protective hard plastic carrying case that houses all kit components. ASME STORAGE CYLINDERS A total of 4 612.5 Cu Ft ASME storage cylinders shall be mounted in a vertical or horizontal rack, each cylinder shall be rated for 7500PSI The system shall have ASME relief valves, isolation valves, drain valves and pressure gauges as required by current by federal and state OSHA codes. DELIVERY, INSTALLATION AND TRAINING The system shall be assembled and tested as a complete system at the factory prior to shipment. A factory test certificate shall be shipped with the system. Page 7 of 8

Two copies of the operation manual shall be shipped with the system. The system shall be delivered FCA seller s premise. The system shall be set up, installed, and checked out at the user s destination by the distributor. The user shall receive training by the distributor on the operation and maintenance of the system as required. INTER-LOCAL JOINT PURCHASING AGREEMENT It is the intent of this bid document to make available to other local government entities of the state of Washington, and neighboring states, as authorized by Inter-Local purchasing agreements as provided for by RCW 39.34, the right to purchase the same equipment/product at the prices quoted for the period of the contract. Therefore, upon award and execution of the contract, the bid unit price and any option prices herein shall remain valid until December 31, 2018. Units may be ordered per inter local agreement after that date, however any price increases may be added to the unit price. Page 8 of 8