Model XSMKIT. Operations and Instructions WARNING

Similar documents
Fire Escape Hood OPERATION AND INSTRUCTIONS

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Phalanx Alpha Phalanx Beta and Ultra Elite

Respiratory Protection

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

A. APPLICATIONS 1. WARNING TO USER

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Respiratory Protection. Program

Pocket Respirators a Survival Essential

Respiratory Protection for Producers

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

"RESPIRATORY PROTECTION AND SAFETY"

Respiratory Protection in Agriculture

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

The Following information is based on material prepared by the American Lung Association

Respiratory Protection Self-Inspection Checklist

8214/8514/07187 Respirator N95 Particulate

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

A. Evaluation of the written program

Respiratory Protection Self Inspection Checklist

M52 Joint Service Chemical Environment Survivability Mask (JSCESM)

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

Standard Operating Procedure

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

Part 18 Personal Protective Equipment

CHAPTER 4 PERSONAL PROTECTIVE EQUIPMENT

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

Standards of Practice Respiratory Protection: Appendix C

The Escape Mindset. The Solution

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Respiratory Protection

VFlex 9105/9105S Particulate Respirator N95

Particulate Respirator N95

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

BREATHE SAFELY: The Proper Use of Respiratory Protection

RESPIRATORY PROTECTION PROCEDURE

HOW TO USE A RESPIRATOR

Respiratory Protective Equipment

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

HEALTH AND SAFETY MANUAL

Respiratory Protection Program

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

Personal Protective Equipment 29 CFR 1926

CONFINED SPACE PROGRAM

Personnel Protective Equipment

COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies.

This program shall contain, as a minimum, the following components:

Standard Operating Procedure (SOP)

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference)

Dräger PARAT Escape Hoods

NH15 ESCAPE HOOD THE MOST COMPACT NIOSH-APPROVED CBRN HOOD

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

low maintenance respirator

Dräger PARAT 3260 Filtering Escape Device

MSA AUER SSR 90 [K60]

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

RESPIRATORY PROTECTION PROGRAM

Using a Filtering Facepiece Respirator

75 Years of Health and Safety Guidance

8200/07023 Particulate Respirator N95

PRODUCT NUMBER: Rd40 Aluminium Canister K2

D Lightweight Respiratory Protection

Respiratory Protection Program

Respiratory Protection

SAFETY DATA SHEET (SDS)

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

NH15 ESCAPE HOOD THE MOST COMPACT NIOSH-APPROVED CBRN HOOD

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits

HAZWOPER 8-Hr Refresher Aug. 20, 2012

Respiratory Protection Program 29CFR

Respiratory Protection Written Program

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

RESPIRATORY PROTECTION

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

Manhattan Fire Protection District

Qualitative Fit Testing Instructions for. KleenGuard* Particulate Respirators

OVERVIEW RESPIRATORY PROTECTION FOR NONFIRE APPLICATIONS

Employee Safety Toolkit. Employee Safety Toolkit. Notes:

LION ERS Glove System

MATERIAL SAFETY DATA SHEET

EP30g, Respiratory Protection.pdf

Section 3. Respiratory Protection Plan (SPPM 3.24)

CHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES

Safety Data Sheet Sludge Reducer

9210/37021, 9211/37022* Particulate Respirator N95

University of Dayton Respiratory Protection Program 29 CFR

PERSONAL PROTECTIVE EQUIPMENT

Personal Protective Equipment

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Transcription:

Xcaper Enterprise Smoke Mask Kit Model XSMKIT Operations and Instructions WARNING THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE, OR WILL HAVE, THE RESPONSIBILITY FOR USING THE XCAPER ENTERPRISE SMOKE MASK KIT. THIS PRODUCT WILL PERFORM AS DESIGNED ONLY IF USED AND SERVICED IN ACCORDANCE WITH THESE INSTRUCTIONS. IF USED OTHERWISE THE XCAPER ENTERPRISE SMOKE MASK KIT MAY FAIL TO PERFORM AS DESIGNED AND ANYONE RELYING ON THIS KIT COULD SUSTAIN SERIOUS ENTERPRISE INJURY OR DEATH. For more information, call: 1-800-368-5705 or visit our website at: www.xcaper.com

SAVE THESE INSTRUCTIONS Xcaper Enterprise Smoke Mask Kit IMPORTANT SAFETY INSTRUCTIONS WARNING READ CAREFULLY AND COMPLETELY The Xcaper Enterprise Smoke Mask is not approved for entry into a contaminated environment, or for respiratory protection while working. An adequate respiratory protection program must include knowledge of hazards, hazard assessment, selection of proper respiratory protective equipment, instruction and training in the use of equipment, and inspection and maintenance of equipment. This respirator will perform as designed only if used and maintained according to the manufacturer s instructions. This respiratory protective device does not supply oxygen! Use only in adequately ventilated areas which conform to the appropriate standard. Use strictly according to the instructions, labels, and limitations pertaining to this device. The Xcaper Enterprise Smoke Mask Kit IS NOT to be used to fight fires. The Xcaper Enterprise Smoke Mask must be stored in its original, unopened foil bag until needed for escape. The mask is for single use ONLY for a short duration and must NEVER be reused. Dispose of the mask if used, damaged or the expiration date is exceeded. Do not use a damaged Xcaper Smoke Mask. The Xcaper Smoke Mask is not designed to provide respiratory protection in the presence of CBRN (chemical, biological, radiation and nuclear) agents. Do not remove the mask while in a contaminated atmosphere. This device WILL NOT PROTECT YOU FROM EXTREME HEAT OR FLAMES. This product is not intended for any use other than self rescue. 2

Xcaper Enterprise Smoke Mask Kit OPERATION AND INSTRUCTIONS WARNING The following instructions must be read and followed by all persons who have, or will have, the responsibility for using the Xcaper Enterprise Smoke Mask Kit. Use strictly in accordance with the instructions, labels, and limitations pertaining to this device. This product has a limited shelf life and should be replaced after the expiration date on the packaging. Inspect the packaging of the Xcaper Enterprise Smoke Mask at least once each year for punctures or tears. Should you find a puncture or tear in the foil packaging immediately return the product to the manufacturer for replacement. The warranties made by Xcaper Industries with respect to the product are voided if the product is not used in accordance with the following instructions. Please protect yourself and/or your family and friends by following the instructions. Please read and observe the warnings and cautions contained in these instructions. General Description The Xcaper Enterprise Smoke Mask Kit has been tested in accordance with EN 403:2004, and is designed to provide respiratory protection for a minimum of 15 minutes from smoke, carbon monoxide, acrolein, hydrogen chloride, hydrogen cyanide and particulate matter as well as other dangerous gases. Training The Xcaper Enterprise Smoke Mask is available in one universal size. Before using the Xcaper Enterprise Smoke Mask, the user should review the donning instructions that follow. This is necessary since the Xcaper Enterprise Smoke Mask must not be deployed until an actual emergency. Shelf Life and Maintenance The Smoke Mask included in the Xcaper Enterprise Smoke Mask Kit has a shelf life of five years. The expiration date is marked on the foil bag label and the Xcaper Enterprise Smoke Mask should be replaced at that time. Periodically and at least once each year you should visually check the foil bag to make sure that it is not damaged, that there are no punctures or tears and that the bag remains vacuumed sealed. Storage Do not store the Xcaper Enterprise Smoke Mask below -1.2 C or above 50.0 C. Always keep the Smoke Mask in a convenient and readily accessible location. Temperatures inside motor vehicle can sometimes exceed 50.0 C. 3

General Usage Instructions The Xcaper Smoke Mask is manufactured with a proprietary (patented), natural formulation that is hypoallergenic and makes the Xcaper Enterprise Smoke Mask feel cool and moist to the touch. You may smell or taste smoke at the beginning of use. DO NOT PANIC! WARNING - Do not use this mask in environments where the temperature is below -7.0 C. Size and Fit The Xcaper Enterprise Smoke Mask come is one size. Due to its unique bean bag design and moisture vapor seal, this mask will fit all faces sized regardless of the presence of facial hair. Use by Children The elastic straps that secure the mask to the face may be too large for use on children under the age of six years old. In the case of an emergency, adults should first don the Xcaper Enterprise Smoke Mask and then place a mask over the mouth and nose of a companion child. In the event that the elastic straps do not hold the mask snugly to the face of a child use a free hand to hold the mask on the child s face while evacuating the area. Use of Goggles This product may not be suitable for individuals that wear glasses. If you wear glasses and require them to see sufficiently in order to evacuate, first try placing the Xcaper goggles over your eyewear to see if you get a good seal. If not, you may place your glasses over the goggles. Should your glasses not fit over the goggles then we recommend you purchase goggles manufactured by Paulson Manufacturing Inc. that are designed to fit over glasses. Due to the tearing nature of the eyes, it is not absolutely necessary to wear goggles, however, your visibility will be enhanced and, as such it is highly recommended that you wear the goggles included in the Xcaper Enterprise Smoke Mask Kit. Verbal Communication The Xcaper Enterprise Smoke Mask may slightly muffle communication; however, communication is possible while wearing the mask. For More Information, Call 1-800-368-5705 or Visit Our Website: WWW.XCAPER.COM 4

The Xcaper Enterprise Smoke Mask Kit DONNING INSTRUCTIONS Open the foil bag by tearing at any of the four notches located on the side edges near the corners of the bag. Do not open the foil bag until the mask is needed in an emergency. Before removing the mask from the foil bag, massage the mask through the bag between the palms of your hands for 1 to 2 seconds. Then, remove the mask from the foil bag. The mask will feel cool and moist to the touch. Place your nose and mouth in the center of the mask and pull both straps over the back of your head. The longer strap should go above your ears around the upper part of your head. The shorter strap should go below your ears around the lower part of your head. Adjust the straps to where the mask feels most secure. In the unlikely event that one of the straps beaks, hold the mask over your mouth and nose with a free hand. Remove the goggles from the protective plastic case. Place the goggles over your eyes and pull the strap over the back of your head. Adjust the goggles to where they are most comfortable. Xcaper Enterprise Smoke Mask Kit Manufactured by Xcaper Industries, LLC PO Box 17119, Irvine, CA 92623 1-800-368-5705 www.xcaper.com 5

Testing Independent laboratory tests have verified that the Xcaper Enterprise Smoke Mask protects against smoke, particulate matter, carbon monoxide and other hazardous gases. The Xcaper Enterprise Smoke Mask will last a minimum of 15 minutes. European Standard EN 403:2004 was used as a basis for testing the Xcaper Enterprise Smoke Mask and Kit. EN 403:2004 was developed for filtering devices with a hood for escape from fire. As the Xcaper Enterprise Smoke Mask Kit is not a hooded device and certain deviations in the testing protocols were necessary. Any instance where a deviation was required is described below. Laboratory Testing The Xcaper Enterprise Smoke Mask has been tested against gases and vapors in accordance with EN 403:2004. Below are the test results for the Xcaper Enterprise Smoke Mask as it pertains to the break through levels permitted by EN 403:2004. Challenge Gas Concentration Allowable Breakthrough Actual Breakthrough Acrolein 100 ppm 0.5 ppm 3.8 ppm Hydrogen Cyanide 400 ppm 10.0 ppm 9.2 ppm Hydrogen Chloride 1,000 ppm 5.0 ppm 1.0 ppm Carbon Monoxide 2,500 ppm 200.0 ppm 115.0 ppm Laboratory testing performed at RNK Environmental, Inc. Erlanger, KY, USA. Although the Xcaper Enterprise Smoke Mask does not meet the allowable breakthrough for Acrolein please note that the U.S. Department of Health and Human Services has published a study stating that the highest levels of Acrolein ever measured in a fire was 3.2 ppm versus the test level of 100 ppm. At 10 ppm of Acrolein the Xcaper Enterprise Smoke Mask has been proven to have an actual breakthrough level of 0.2 ppm. EN 403:2004 requires testing against four different concentrations of carbon monoxide to establish the catalytic characteristics of the materials used. The Xcaper filter does not contain catalytic materials so it was only tested against one concentration of carbon monoxide, as shown above, and met the standard for that test. EN 403:2004 requires an integrity test to be performed on hooded devices. As the Xcaper Enterprise Smoke Mask Kit does not include a hood, this test was not performed. 6

EN 403:2004 also requires that leakage tests be performed on hooded devices to test for inward leakage in the breathing zone and the ocular zone. As the Xcaper Enterprise Smoke Mask Kit comes with goggles, these tests were performed with over 20 test subjects, with and without facial hair, eye glasses and contact lenses. These tests indicated that there was no leakage into either the breathing zone or the ocular zone. The Xcaper Enterprise Smoke Mask has been shown in laboratory tests to filter 99.6% of particulate matter at a size of 0.3 microns which meets the requirements of EN 403:2004. However, these tests were not performed in accordance with EN 403:2004 which uses sodium chloride in accordance with the requirements of EN 143. Instead, the tests performed on the Xcaper Enterprise Smoke Mask utilized 0.3 micron latex spheres. Field and Live Fire Testing The Xcaper Enterprise Smoke Mask has also been tested under live fire conditions by firefighting professionals in California, New York and Mexico. Such conditions are not controlled to the extent they are during laboratory testing. However, these tests provide additional evidence of the efficacy of the Xcaper Enterprise Smoke Mask. These tests have shown the Xcaper Enterprise Smoke Mask to be effective against the harmful effects of smoke for a minimum of 15 minutes. Do not attempt to use the Xcaper Enterprise Smoke Mask except in the case of an emergency. NOTES 7

About Xcaper Industries, LLC Xcaper Industries, LLC develops, manufactures and sells respiratory protection products. Whether it is a life threatening situation or a hazardous work environment our revolutionary, patented filtration technology can provide protection against toxic gases and deadly particulates. Our products address the occupational needs of firefighters, law enforcement, first responders and emergency service workers. Our technology is also utilized in products that protect everyday citizens who may become exposed to dangerous situations. Xcaper Industries, LLC PO Box 1719 Irvine, CA 92663 USA 1-800-368-57058 www.xcaper.com 8