Section 8100 Index SIGHT FEED VALVES WITH SHUT-OFFS...45 BULLS-EYE SIGHT FEED VALVES UNIVERSAL...42 FULL VISION FLOW SIGHTS...49 OVERFLOW SIGHTS...

Similar documents
Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

shutoff valves 900 Series psig Manual Shutoff Valves

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Choosing the right miniature instrument and control valve is a snap

1800CPB2 Service Regulators

VERTICAL BLADDER TANK

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Pressure Regulator B-95

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Model Series 62 Constant Differential Relay

HORIZONTAL BLADDER TANK

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

FILTER TYPE PRESSURE SNUBBER

Pressure Dump Valve Service Kit for Series 2300 Units

Installation, Operation, and Maintenance Manual

Air Operated Hydraulic Pumping Systems to 50,000 psi

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

1800CPB2 Pilot-Loaded Service Regulators

TECHNICAL DATA. Q = C v P S

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

TECHNICAL DATA. Q = C v P S

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

TECHNICAL DATA. Q = C v P S

PRO-50 Instrument Supply Regulator

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

TECHNICAL DATA. Q = C v P S

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

TECHNICAL DATA. Q= Cv S

ADAPTABILITY & PRECISION

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Eaton Filtration, LLC

Chlorinator. MODEL C-731 (Floor Mounted)

1800C and 1800C-HC Service Regulators

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Eaton Filtration, LLC

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Types 749B and R130 Changeover Manifolds

Industrial Regulator Series 1800/2000

Pressure Dump Valve Service Kit for Series 3000 Units

1800C & 1800C-HC Service Regulators

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

S300 Series. Valve Link. Features. Fisher Controls

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

2.0 INSTALLATION & SERVICE

627 Series Pressure Reducing Regulators

Dean Pump Self-Priming Chemical Process Pumps

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Suggested Installation & Operating Instructions for Sidewinder Pumps

OWNER S TECHNICAL MANUAL

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

D05T Compact Design Pressure Regulating Valves

GREIG FILTERS, INC. OPERATION MANUAL

Variable Area Flow Meters

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

TECHNICAL ACCESSORIES

Pressure Sensing Valve - Model 4023

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

Installation, Operation, and Maintenance Manual

Worldwide Contacts. General Description

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

776 Cryogenic Safety Valve

TECHNICAL DATA CAUTION

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Flow Material Length. Weight GPM LPM. Style 3095

Horizontal Bladder Tanks

FILTER BYPASS CONTROL

CASH VALVE TYPE KP BACK PRESSURE VALVES

ACCU-MIX 1200 / / 26270

Vertical Bladder Tanks

BACK PRESSURE / SUSTAINING

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Constant Pressure Crude Oil Container Model CPCCP

Models: C62/63/64-A/D

TEST SPECIFICATION NYT-909-C

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Air Amplifiers & SYSTEMS

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

DBML-60/80 Squeeze Tool

D05 Pressure Regulating Valves

Regulator from 1800 B series

Transcription:

Section 800 Index BULLS-EYE SIGHT FEED VALVES UNIVERSAL...42 Ruggedly constructed, provide adjustable, visible flow control on pressurized or gravity feed systems. Units selected according to piping arrangement and are used where considerable capacity of fluid must be dispensed. SIGHT FEED VALVES WITH SHUT-OFFS...4 Provide adjustable, visible flow control. Straight pattern regulates liquid flow from full flow to complete shutoff. Toggle and solenoid shutoff provide complete shutoff while retaining flow setting. FULL VISION FLOW SIGHTS...4 OVERFLOW SIGHTS...4 Full Vision Flow sights provide visible flow and are used on gravity or pressurized oil lines. Overflow Sight provide constant visible oil level for circulating oil systems. SMALL SIGHT FEED VALVES...4 Provides adjustable, visible flow control on pressurized or gravity feed systems. Units are selected according to piping arrangement requirements. MULTIPLE SIGHT FEED VALVES...44 Provide adjustable, visible flow control to widely separated points from one central location. Used on pressurized or gravity feed systems. Select according to number of locations to be lubricated. PREISION RELIEF VALVES...4 Precision Relief Valves provide safety where certain maximum pressure should not be exceeded. Units are adjustable. SOLENOID VALVE OPERATORS...46 ONSTANT FLOW ONTROL VALVES...46 Solenoid operators are available in all voltages and frequencies. onstant flow control valves provide a fixed flow rate and are used in low pressure lubricating systems. WINDOW FLOW SIGHTS...48 Flow sight with restrictive orifices provide a visible fixed flow rate which can be selected according to orifice size. Full flow sights provide a visible flow with no restrictions to flow rate. Section 800 Index SHUTOFF VALVES...4 Provide rapid, positive open/closed action. Operates in any position and are compact in size. Offered with either toggle or solenoid shutoff controls. P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6 4

Universal Sight Feed Valves Universal Sight Feed Valves Unique porting arrangement simplifies field piping and installation. Extremely sturdy cast aluminum one piece body. Vent Hole Large sight glass windows permit excellent observation of the liquid stream. Threaded retaining rings secure the glass sights. Excellent flow haracteristics Pressure 2 P.S.I. to Orifice P.S.I. Sight hamber Maximum with Vent Sealed Valve Body Aluminum, Gold Anodized Needle Ass y Steel, Plated Sight Glass Temperature 22 F. Maximum Port ¼ Dia. Sight ½ Dia. Style SFB UNIVERSAL PATTERN BULLS-EYE SIGHT FEED VALVES allow visual observation of the liquid stream from a distance, with the volume of flow controlled by an adjustable needle valve. The Bulls-eye sight feed valve has excellent flow characteristics with low pressure drop. These units are principally used on gravity or pressure oiling systems of larger machinery for lubrication where considerable capacities of oil must be dispensed. The rugged, sturdy construction makes them especially suitable for paper mill machinery, steel mills, rolling mills, sugar mills, steam and gas engines, gear units, etc. Their use can be extended to any application requiring adjustable, visible flow control. Large sight glass windows on both sides of the valve are properly gasketed to prevent leakage and permit an excellent observation of the liquid stream. The sights can easily be removed for cleaning or replacement without disconnecting the valve. Threaded retaining rings on both sides secure the glass with full circumferential support for excellent sight pressure integrity. The unique features of this valve is the porting arrangement, which allows the user to select several combinations of patterns to simplify field piping and installation. Body Style B D B-20- B-20-2 B-20- B-20-4 B-20- B-20-6 B-20- B-20-8 T-Handle Tamperproof 4 4 6 6 Also Available in Remote Mounting /6 /6 /6 /6 /6 /6 42 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6

Small Sight Feed Valves Needle valve regulates liquid flow from full flow to a complete shutoff. Precision flow control for fine metering of liquids. Large vented sight chambers are provided for easily observing the flow of liquid. SMALL SIGHT FEED VALVES control the volume of liquid being dispensed while permitting visual observation of liquid flow. The valves are primarily used on gravity or pressure oiling systems for bearing lubrication on machinery. Their use can be extended to any application requiring adjustable, visible, flow control. They are equipped with needle valve control that regulates liquid flow from full flow to a complete shutoff. The valves are available with a conventional exposed adjustment, but can be provided with tamperproof construction. The construction is rugged and sturdy. The bodies are made of plated steel. The sight glass is firmly held between two seals, a solid one at the bottom and a split one on top for venting. The purpose of the vent is to eliminate any air block which might occur in some applications which develop a suction or back pressure. There are some applications under which vacuum or pressure must be maintained on the discharge side of a valve. For applications requiring air tight sight chambers, solid gaskets can be provided. Body machined from solid bar stock resulting in sturdy and compact designs. Pressure 2 P.S.I. to Sight Glass Orifice Sight hamber Body Steel, Plated, Sq. is Vented Temperature Port Style SFG 22 F. Maximum /6 Dia. B-6- B-6-2 B-6- B-6-4 B-6- B-6-6 B-6- Straight O.D. Tube O.D. Tube Remote Also Available w/ and Tamperproof B 2 2 2 2 2 /6 2 /6 2 Small Sight Feed Valves Angle ross Inverted Angle L L L B-628- B-628-2 B-628- B-628-4 B-628- B-628-6 B-628- O.D. Tube O.D. Tube Remote 2 /6 2 /6 2 /6 2 /6 Also Available w/ and Tamperproof /6 B-62- B-62-2 B-62- B-62-4 B-62- B-62-6 B-62- O.D. Tube O.D. Tube Remote 2 /6 2 /6 2 /6 2 /6 Also Available w/ and Tamperproof /6 B-60- B-60-2 B-60- B-60-4 B-60- B-60-6 B-60- O.D. Tube O.D. Tube Remote 2 2 2 2 2 2 Also Available w/ and Tamperproof /6 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6 4

Multiple Sight Feed Valves Multiple Sight Feed Valves Needle valve assembly permits fine adjustment over the entire range,from extremely low drop rate to a stream. Generous sight viewing glass. B-0-2 B-0- B-0-4 B-0- B-0-6 B-0- B-0-8 B-0- B-0-0 B-0- B-0-2 B-0- B-0-4 B-0- B-0-6 B-0- B-0-8 B-0- B-0-20 B-0-2 B-0-22 B-0-2 B-0-24 No. of Feeds 2 4 6 8 0 2 4 6 8 20 2 22 2 24 Modular stacked manifold system permits feeding of liquid to widely separated points. Pressure 2 P.S.I. to Valve Body Aluminum Alloy Sq. Orifice Sight hamber Sight Glass is Vented Temperature 22 F. Maximum Port /6 Dia. L 2 4 6 6 8 M 4 6 6 8 0 2 2 4 6 8 8 Style SFM Additional Valves Specify Part B-- MULTIPLE SIGHT FEED VALVES permit feeding of liquids to widely separated points, controlled and observed from one central location. They are suitable for gravity or pressure lubricating systems. These valves are used in a variety of industries: chemical, mining, paper, agricultural, marine, woodworking, textile, and can be used to lubricate typical equipment like pumps, compressors, machine tools, bearings, seals, punch presses and rollers. A revolutionary principle regarding the assembly of these valves has been incorporated. The customer, for the first time. has the option of changing the unit in the field by merely stacking them together, eliminating the costly tie-rod and manifold method. Very compact, the multiple valves require only the minimum amount of space making the valves especially suitable for lubricating inaccessible places. onstruction is extremely sturdy using a " square aluminum alloy. O rings between the valves form a positive seal. The generous sight viewing glass is firmly held between two gaskets. Buna-N seals are furnished throughout and are suitable in operation for 22 F. and 2 P.S.I. maximum. The valve assembly is provided with a single " female inlet, and the outlets are equipped with " O.D. tube fittings. The sight chamber of the valve is equipped with a vent. The purpose of this vent is to eliminate any air block which might occur in some applications which develop a suction or back pressure. Modification for special applications can also be furnished such as solenoid actuation, special gasket material and other materials. onnector Kit A-6- onnector Kit for Multiple Sight Feed Valve Part A-6-44 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6

Sight Feed Valves with Shutoffs ADJUSTABLE SIGHT FEED VALVES WITH TOGGLE SHUTOFF are widely used for gravity oiling systems where small quantities of liquid are to be dropped in. Their use can be extended to applications requiring adjustable, visual, flow control. The needle valve permits fine adjustment over the entire range, from extremely low drop rate to a stream. The adjustments are retained by a friction lock. The toggle shuts off the flow completely, without interfering with the setting in any way. The sight chamber below the needle valve allows visual check of the feed rate and the venting of this chamber allows discharge by gravity. Pressure 2 P.S.I. to Drip Nozzle, Sight hamber is Vented Temperature 22 F. Maximum Port Dia. Body Aluminum Alloy Sight Glass ADJUSTABLE SIGHT FEED VALVES WITH SOLENOID SHUTOFF permit shutoff of drop feeding without disturbing the selected adjustable flow rate. A Needle valve regulates liquid flow. Fine adjustments can be made and the sight chamber permits excellent observation of the liquid. The friction lock retains the setting. The solenoid is available in all voltages and frequencies and the coil is permanently molded into the housing, creating a very durable and water resistant construction. The sight chamber of the valve is equipped with a vent. For applications requiring air tight sight chambers, solid gaskets can be provided. Pressure to Drip Nozzle P.S.I. D 0 P.S.I. A Sight is Vented Temperature 22 F. Maximum Port Dia. Body Aluminum Alloy Sight Glass Sight Feed Valves with Shutoffs Model Voltage and Frequency B-64- B-64-2 B-64- B-64-4 B-64- B-64-6 B-64-8 B-64- B-64-0 B-64- B-64-2 B-64- B-64- Male Male Male -8 Thd. /6-20 Fem. Thd. O.D. Tube O.D. Tube Male Male O.D. Tube O.D. Tube 2 /6 2 /6 2 /6 2 /6 2 2 2 /6 2 /6 Model B-8- B-8-2 B-8- B-8-4 B-8- B-8-6 B-8-8 B-8- B-8-0 B-8- B-8-2 B-8- B-8- Male Male Male O.D. Tube O.D. Tube Male Male O.D. Tube O.D.Tube -8 Thd. 2 /6 /6 2 /6 2 /6 2 /6 /6 B-64-8 -8 Thd. /6 B-8-20 -8 Thd. 2 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6 4

onstant Flow ontrol Valves & Solenoids ontrol Valves & Solenoids ONSTANT FLOW ONTROL VALVES have a fixed flow rate and can be equipped with orifices producing a specific flow rate ranging from ounces per minute to gallon per minute. The flow rate selected will remain constant within plus or minus 20% for ounces to ounces per minute, and within plus or minus 0 % for pint to gallon per minute. This accuracy will be retained with varying pressures, ranging from PSI minimum to 2 PSI maximum, and with any oil having a viscosity of 400 SSU minimum to 0 SSU maximum. Flow control valves are used in low pressure lubricating systems. They do not require frequent adjustment usually needed on ordinary valves and are, therefore, especially suitable for use in automated plants, for elevated, distant, or hard to get at places. The cylinder in the body, as well as the piston and spring, can readily be removed due to the unique construction. This allows a piston with a certain orifice to be exchanged with a different one for changing the flow rate if necessary. Flow Rate Non Adjustable See Table Pressure P.S.I. Minimum 2 P.S.I. Maximum Temperature 22 F. Maximum Oil Viscosity Between 400 SSU and 0 SSU Body Aluminum Alloy Piston Brass Piston increases or decreases the area of the outlet port of the cylinder, furnishing a constant flow rate under varying pressure. Style SP SOLENOID VALVE OPERATORS are designed to achieve new standards of quality and reliability. The new operator is available in all voltages and frequencies. onstruction is very rugged. The coil housings are steel, with a ½ NPS conduit connection. The coil is permanently molded into the housing, creating a very durable, water resistant construction. The center core and plunger are stainless steel. Buna-N plunger seat and seals are standard. Ethylene propylene and Viton - A seals are also available. This operator has been designed to achieve an absolute minimum amount of maintenance and repair which has become increasingly important in the lubricating industry. Oil-Rite is completely confident in this new design and will warranty each unit against failure. A free replacement coil is offered for any coil that fails in the field. This is an exclusive feature of Oil-Rite. This new operator is interchangeable with the following Oil-Rite electrically controlled lubrication dispensers, chain oiler and valves: DEY, DE, DEH, DEJ, DEF, DE, SLVA, and SLV. Media Temperature -4 F. to +8 F. Nominal Power Watts oil onstruction lass B +0. Water Resistant oil Housing Steel enter ore Stainless Steel Plunger Stainless Steel, Ethylene Propylene,Viton -A Water Resistant molded coil. Designed to achieve an absolute minimum amount of maintenance and repair. Style SLV B-844- B-844-2 B-844- B-844-4 B-844- B-844-6 B-844- B-844- Flow Rate Per Minute OZ. 6 OZ. OZ. PT. QT. GAL. GAL. GAL. Flow Tolerance ± 20% ± 0% Orifice Size.024.0.08.04.06.0.06. Model Voltage and Frequency Model B-2- B-2-2 B-2- Special - Please onsult Factory Viton is a registered trademark of Dupont Dow orp. Seal Material Buna-N Viton -A Ethylene Propylene 46 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6

Shutoff Valves & Precision Relief Valves SOLENOID SHUTOFF VALVES are compact and suited for applications requiring rapid, positive, open and closed action in locations where space is a premium, hard to reach, or in automated plants. It operates in any position and is furnished with ¼ pipe threads. The solenoid valve is normally closed. When current is applied to the solenoid, the valve port opens and it is automatically closed again when the current is shutoff. These valves are for continuous duty and flow cannot be adjusted. They are available in all commercial voltages and frequencies. The coil is permanently molded into the housing, creating a very durable, water resistant construction. Solenoid valves are usually pipe mounted. They are sturdy in construction, using aluminum alloy bodies and stainless steel plungers and springs. Buna-N seals are standard. Neoprene, Butyl, or Ethylene Propylene and Viton -A seals are also available upon request. Mechanical 2 Way NEMA Temperature Electrical Nominal Power oil onstruction Materials Body Seals Optional Seals oil is molded into the housing, creating a water resistant construction. Normally losed Enclosure 22 F. Maximum Watts Valve port opens when current is applied and is automatically closed when current is shut off. orrosive resistant aluminum body. lass B +0. Water Resistant Aluminum Alloy Buna-N Ethylene Propylene,Viton -A, Neoprene Butyl Style SLV PREISION RELIEF VALVES meet the industry s requirements for more exacting and reliable performance. The relief valve has a fixed upper pressure rating which is held within close tolerances. In addition, relief pressures can be reduced and any setting locked. The setting for the upper limit is tamperproof and cannot be adjusted. These units are used as a safety device on reservoirs where a certain maximum pressure should not be exceeded, or for any other application demanding pressure to be relieved at a specific value. The valves are offered in relief pressure ratings of 0 PSI and 60 PSI maximum. They have a ¼ inch pipe thread. The function of this device is simple. A plunger equipped with an O-ring is seated against a port inside the valve body. A spring holds the plunger to its seat. An enclosure cap is screwed over the valve body which is used to adjust the valve for the upper pressure limit. A vent hole on the top of the cap allows the escape of the released air or liquid. A locknut is provided on the valve body to lock the cap in place. Units are installed by means of the pipe thread provided. To use the relief valve for the maximum rated pressure, screw the top cap down until seated and lock this setting with the locknut. Should it be desirable to reset the valve for a lower pressure, it is only necessary to back off the top cap to a suitable point producing the desired pressure relief, and lock the setting with the locknut. Pressure Adjustable Temperature 22 F. Maximum Body Aluminum Alloy Piston Brass Seal Viton -A Spring Stainless Steel Stainless Steel spring holds the plunger to its seat. Style SFB orrosive resistant aluminum body. Shutoff Valves & Precision Relief Valves Model Voltage and Frequency Seal Material Model B-2- B-2- Orifice Size /6 Maximum Pressure 0 P.S.I. 2 P.S.I. A-444- A-444-2 Pressure Setting Minimum Maximum P.S.I. P.S.I. 0 ± P.S.I. 60 ± P.S.I. Viton is a registered trademark of Dupont Dow orp. P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6 4

Window Flow Sights WINDOW FLOW SIGHTS WITH RESTRITED ORIFIE dispense liquid at a fixed flow rate which is determined by the orifice selected. The flow of liquid is downward through a nozzle in the transparent sight and can readily be observed. Pipe threads for inlet and outlet are provided. All units are normally furnished with a pressure tight sight. These flow sights have many applications. They provide a simple, tamperproof method of furnishing the desired amount of lubrication for bearings without the use of control valves. The sights can be used as components in oiling systems and in a multitude of applications involving fluid transfer. The construction is rigid. Bodies are machined from steel bar stock, and are plated. Buna-N seals are used. and outlet are offered in or female pipe threads. The sights are glass. There are four standard orifices available, ranging from to in diameter. Special orifices are available on request Pressure Temperature Sight Body Seals Orifice 2 P.S.I. Maximum 22 F. Maximum Glass-Pressure Tight Solid Gaskets Steel, Plated Buna-N Brass WINDOW FLOW SIGHTS FOR FULL FLOW offer no restrictions to the flow, permitting liquid to flow freely. The flow of liquid and its clarity can be visually observed through the sights. The units have an airtight sight chamber. The Window Sights are primarily used in low pressure oil lines. There are no restrictions on the inside, therefore, no pressure drop, resulting in the full flow of liquid equal to respective pipe size. They can be installed in any position, either horizontally, vertically, or at an angle, and are offered in various pipe sizes. onstruction is simple and sturdy. Body is made from bar stock and is steel, plated. The sight is glass with Buna-N seals. Maximum recommended pressure is 2 P.S.I., and maximum temperature is 22 F. There are five standard pipe thread sizes ranging from to female pipe thread. Larger sizes can be provided on request. Pressure Temperature Sight Body Seals 2 P.S.I. Maximum 22 F. Maximum Glass-Pressure Tight Solid Gaskets Steel, Plated Buna-N Window Flow Sights B-222- B-222-2 B-222- B-222-4 Style SF Restricted orifice dispenses a fixed flow rate of liquid. Bodies are machined from steel bar stock and are plated. Flow values shown in table are approximate and are based on #20 oil at 0 F. at 0 P.S.I. and gravity discharge. Orifice Dia. /6 G.PM..06.2.6. Style SF Liquid flow rate will be approximately equal to that for the respective pipe size. A-- A--2 A--2 A--2 A-20- Fem. Fem. /6 /6 Special - Please onsult Factory Metering a constant rate of flow through a fixed port. Visual indication of liquid flow, clarity and condition of liquid. B 2 2 2 /64 D /6 /6 /6 I /6 /64 /6 K /6 /6 /6 /6 48 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6

Full Vision Flow & Over Flow Sights FULL VISION FLOW SIGHTS WITH RESTRITED ORIFIE are used in oil lines to check the flow of oil and its clarity by visual observation. The large size and construction permits maximum visibility and dependable inspection of liquid flow from a distance. They are often used at elevated heights to tell at a glance whether oil is circulating. The flow of liquid is downward through a nozzle in the sight. All units are furnished with a removable vent plug. The sight chamber is normally vented when flow is discharged by gravity and closed when flow is discharged by low pressure. Pressure 2 P.S.I. Maximum for Acrylic 0 P.S.I. Maximum for Pyrex Temperature 60 F. Maximum Acrylic, 22 F. Maximum Pyrex Bodies Aluminum Sights Acrylic, except Dia. which is ellulose Acetate and Pyrex Style SFX Style SFX Transparent sight permits maximum visibility and inspection of liquid flow from a distance. Light in weight with aluminum alloy body. Restricted orifices and large sight offer a simple, effective, tamperproof method for dispensing liquids at a specific flow rate. OVER FLOW SIGHTS are used in oil lines of circulating systems to maintain a constant visible oil level. In addition, they permit checking of the liquid flow and clarity of liquid at a glance. Used mainly on large ring oil or reservoir type bearings of steam turbines or gear boxed, they can be used on many other applications. The construction is lightweight with aluminum alloy bodies and acrylic sight chambers withstanding temperatures up to 60 F. Pyrex sights are available on request which withstand up to 22 F. Bolts and standpipe are steel, plated. Buna-N seals are standard. The unit is very rigid, but can be disassembled for cleaning if required. Pressure Low Pressure to Stand Pipe Gravity Discharge Temperature 60 F. Maximum Body Aluminum Alloy Sight Acrylic, Pyrex Stand Pipe Steel, Plated Style SO Full Vision Flow & Over Flow Sights Acrylic Pyrex B-8-2 B-8-22 B-66-4 B-66-4 B-8-2 B-8-22 B-26- B-26-4 B-26- B-26-4 Fig. 2 2 A 2 2 2 B 2 2 2 2 /6 /6 D /6 I /6 /6 K 2 4 4 G.P.M.. 2.4 6. 6 26. B-2- B-2-2 B-2- B-2-4 B-2-6 Special - Please onsult Factory Pyrex Sight P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6 4 I /6 /6 /6 /6 /6 N

Notes Notes 0 P. O. BOX 20, MANITOWO, WI 422-20 (20) 682-6 FAX (20) 682-6