Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

Similar documents
OptiCare. Optimising patient care

Symbioso 200. Integrated air surface for Multicare hospital bed HEALTHCARE

PRESSURE REDISTRIBUTION SYSTEM. with people in mind

ALPHAXCELL. Active pressure relieving mattress overlay system for medium risk patients in all environments

NIMBUS range. with people in mind

LOGIC RANGE AUTOMATIC PRESSURE

Air Plus User Manual

LIFECOMFORT ACTIVE AIR

LOGIC RANGE AUTOMATIC PRESSURE REDISTRIBUTING SySTEMS

Interface Pressure Testing as an Alternating Pressure Surface

AIRCARE INTERNATIONAL Unit 3, Shannonside Business Park, Birdhill, Co. Tipperary,Ireland Tel : +353 (0) Fax : +353 (0)

Domus series. Pressure Redistribution System

Pressure Ulcers ecourse

Autom ate d t u r n i n g at yo u r f i n g e r t i ps

Seating Systems. The Company. Park House

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

User manual STARLOCK. Careways International - Innovation Quality Performance

Paradise Pump Series Operator s Manual

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

2015 Products Catalog Product Catalog. Products designed for the treatment and prevention of wounds

Foam Mattress & Cushion Range

Intelli-Gel Cushions. cushions. kirton-healthcare.co.uk

Adult Pressure Care. Star Cushion. High Performance Air Cell Cushions

Harvest Healthcare Clinical Evidence. P161M - Viscoflex Mattress P161MOE - Viscoflex Evolutive Mattress

CLPNA Pressure Ulcers ecourse: Module 5.2 Quiz II page 1

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

PressureGuard Custom Care Convertible LAL. Series

EVERYONE KNOWS WE WORK BEST UNDER PRESSURE. + WE CAN HANDLE MOISTURE TOO. ROHO S/A

DENAS Reflexo (p.21 40)

Dynamic pressure system for pressure relief

The next generation of Blood and Fluid Warming

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

An intuitive and innovative answer to your anaesthesia challenges

Instruction Manual for Configura Cushionair Portable Pump

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual soft air wds

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

QubiCell series. QubiCell series. QubiCell series. Pressure Redistribution System Comprehensive Care - Ultimate Comfort

User Guide Antidecubitus systems EURO BASIC

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

Mangar ELK Instruction & Safety Manual

New. View our Evolution Product Video at

Focused on essentials DRÄGER SAVINA 300

The next generation of Blood and Fluid Warming

E V E RYONE K N OW S WE WORK BEST P R E S S U R E. + MOISTURE TO O. RO H O

Cushions for pressure relief in the seated position

CircuFlow Quick Setup Guide

INDEX. Specifications 1. Important Safety Precautions 2. Operating Instructions 3, 4. Optional Extras (Meal Tray & Footrest) 5.

Solutions for transcutaneous monitoring

NIMBUS 4 NIMBUS PROFESSIONAL

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction.

Cobi Positioning Cushions

Series Environmental Chambers

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

ila ACTIVVE SYSTEM PLATFORM

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Intelligent Ventilation solution from ICU to MRI

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Reusable Model Numbers. Double-Coated Reusable Model Numbers. Model Numbers

Drilling Efficiency Utilizing Coriolis Flow Technology

DYNAMIC COMPRESSION THERAPY

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

Safe, comfortable & smart Forced Air Warming

FOCUS - ON - PATIENTS

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

Pneumatic high-pressure controller Model CPC7000

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Patient Home Care Information

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

AUTOVENT 4000 VENTILATOR

Supporting you in saving lives!

Innovation at its best

Focused on essentials DRÄGER SAVINA 300

Safe, comfortable & smart Forced Air Warming

Med Aire Alternating Pressure Pump and Pad System

Use this key to determine which sections of this Product Manual apply to your job.

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

TECOTHERM NEO. Instructions for Use. MEDICAL EQUIPMENT for HYPOTHERMIA of NEONATES and INFANTS. Addendum 1 to

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

fabian Therapy evolution Our 2-in-1 device

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Pressure relief characteristics in alternating pressure air cushions

C O R P O R AT E B R O C H U R E

(DynaLaL III) Dynamic True Low Air Loss Mattress Replacement System

RAM 4021-DPX Operation Manual

Panther 5 Acute Care Ventilator

How did we design such a revolutionary alternating pressure mattress system?

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

ANZAI AZ-733VI. Respiratory Gating System. since 1976

Pneumatic high-pressure controller Model CPC7000

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

RIK Fluid Overlay INSTRUCTIONS FOR USE

Transcription:

Precioso series 2 Prevention and therapy for everybody, everyday HEALTHCARE NURSING-CARE

EFFECTIVE PROVEN PREVENTION AND THERAPY Effective and proven pressure ulcer prevention and therapy for all at risk patients in everyday general nursing environments. safety of care Patient and carer safety are key factors in this system design. Precioso provides many features specifically to enhance the safety of all who come into contact with this product. flexibility of care The Precioso mattress system offers a wide range of features and options to create a flexible 24 hour care package designed to meet the pressure area care needs for nursing all at risk patients in everyday care environments. EFFORTLESS DELIVERY OF CARE The ease of use, cleaning and maintenance features of Precioso make nursing and maintenance tasks as simple and fast to perform as possible.

Effective, proven prevention & therapy Precioso with 3 cell technology provides the benefits of Zero Pressure for maximum prevention and Regular application and removal of pressure for maximum therapy. The 7.5 minute cell cycle simulates the body s normal response to pressure for natural protection. PRESSURE High Risk [01] ZERo pressure Kosiak 1 studied the link between pressure and time and showed that even very low pressure when being unrelieved will over a long period of time lead to tissue damage. He concluded that since it is impossible to completely eliminate all pressure for a long period of time, it becomes imperative that the pressure be completely eliminated at frequent intervals in order to allow circulation to the ischaemic tissues. LOW Risk ulceration no ulceration TIME [01] [02] regular application and removal of pressure The innovative design and construction of the connected air cells allows effective removal and application of pressure. This has been proven to increase the therapeutic effect of the system and promotes accelerated wound healing 2, 3. [02] REFERENCES 1 Kosiak, M., Etiology of pressure ulcers. Archives Physical Medicine and Rehabilitation. 1961; 5: 19 29. 2 West, J. et al. The effect of a unique alternating pressure mattress on tissue perfusion and temperature. Presented at the European Tissue Repair Society Conference 1995 3 Gunter, R.A. and Clark M. The effect of a dynamic pressure redistribution bed support surface upon systemic lymph flow and composition. Trend of Tissue Usability 10(3):10 15. 4

Effectiveness of an active system is a key issue in dealing with pressure sores. Carers should be well aware of what equipment they are using and should put their patient solely on proven therapy products. [03] 3 CEll TECHNOlOgY [A, b, C] The patient body weight is distributed onto two thirds of the surface thus allowing the mattress to be soft and comfortable without compromising its clinical outcome. moreover, since only one third of the surface is active at a time (infl ating/defl ating) it provides optimum stable support to the body enabling maximum pressure relief to be achieved. A B C 7.5 minute CYClE Exton-smith and sherwin studied number of movements in healthy subjects while sleeping in order to fi nd out what is the natural body behavior 4. They found out that none of the patients who moved more than 56 times during the night developed tissue damage. This frequency is equivalent to about one movement each 7.5 minutes. [03] Zero Pressure 3 cell [A, b, C] cycle [04] CONsTANT low PREssuRE Automatically maintains the selected pressure regardless of changes in the patients weight distribution or position to achieve constantly good levels of pressure redistribution. The use of active pressure redistribution products, such as ClP, is recommended for use for patients at higher risk of pressure ulcer development where frequent manual repositioning is not possible and is supported by direct scientifi c evidence from properly designed and implemented clinical studies 5. Results are for a 51 kg. 5 2 female subject ClP level 1 pressure setting supine position Results are for a 91 kg. 5 7 male subject ClP at level 2 pressure setting supine position Average pressure 22 mmhg. greater than 80 % of sensors reading below 20mmHg Average pressure 18 mmhg. greater than 55% of sensors reading below 20mmHg 4 Exton-smith, AN, sherwin RW. The prevention of pressure ulcers: signifi cance of spontaneous bodily movements. lancet. 1961; 2: 1124 1126. 5 EPuAP and NPuAP Prevention and treatment of pressure ulcers: Quick reference guide 2009. Process description statement Typical interface pressures measured in laboratory conditions by a clinical professional after 20 minutes, allowing time for force maturation. All test subjects were healthy individuals and found the surface to be comfortable after approximately one hour of use. [04] Constant low Pressure (ClP) 5

safety of care Patient and carer safety are key factors in this system design. Precioso provides many features specifically to enhance the safety of all who come into contact with this product. [01] CARDIO PulmONARY REsusCITATION (CPR) Operated by one hand, CPR enables rapid deflation for emergency situations and is accompanied by visual and audio alarms to prevent inadvertent use. [02] CAblE management Easy to use cable management system eliminates tripping hazard for staff and visitors. Also reduced potential power cable damage increases equipment availability and decreases repair costs. [01] [03] AIR FIllED side FORmERs Full length air fi lled side formers for improved patient & carer safety & security both in and while getting out of bed. [02] AIR FIllED side FORmER [03] 6

Easy, safe operation. less staff training. more time for other tasks. [04] WATER PROOF AND VAPOuR PERmEAblE COVER Two way stretchable Dartex cover is fully water proof and vapour permeable. Prevents the infection control risk from fl uid being absorbed into the mattress surface. Also reduces the risk of skin maceration due to liquid absorption and patient perspiration. [04] [05] WAVE ACTION Three cell infl ation cycle working from the foot to the head of the mattress helps prevent the patient from sliding down in bed and requiring nursing assistance to reposition. [05] [06] go button locks out controls when they have not been used for 3 minutes lowering the chance of human errors and accidental operation. [06] 7

Flexibility of care The Precioso mattress system offers a wide range of features and options to create a fl exible 24 hour care package designed to meet the pressure area care needs for nursing all at risk patients in everyday care environments. [01] FOuR mattress OPTIONs mattress replacement or active overlay options, provide fl exibility for different facilities and for patient weights. [01a] mattress REPlACEmENT system OPTION This option is designed as a full autonomous pressure relieving system used in place of the original mattress. [01a] mattress replacement system option [01b] ACTIVE OVERlAY OPTION The overlay is designed to be used together with the existing bed mattress. It is smaller & light weight for easy handling & storage. [01b] Active overlay option [01c, d] OPTIONAl INTERNAl FOAm mattress. For heavier patients (up to 210 kg) or those that wish to feel higher when laying in bed, an additional foam mattress can be easily fitted beneath the central air cells. [01c, d] Optional internal foam mattress [02] 4 WORKINg modes OPTImIsINg CARE AlTERNATINg PREssuRE THERAPY is the basic therapeutic mode simulating the natural movement of a patient and thereby helping prevent and treat pressure ulcers. max INFlATE presents firm and stable support for patient care. After 30 minutes it automatically switches to the alternating mode to prevent the risk of pressure ulcers. CONsTANT low PREsuRE automatically maintains the selected pressure regardless of changes in the patient s weight distribution or position to achieve constant good levels of pressure redistribution. TRANsPORT mode facilitates the transport of the patient in the bed as the mattress remains inflated for 24 hours when disconnected from the scu. [02] 4 working modes [03] DYNAmIC CusHION 24 HOuR CARE The optional alternating pressure dynamic seat cushion facilitates 24 hour care. uses the same system Control unit (scu) as the mattress. scu automatically changes to cushion mode when cushion connected, no manual adjustment required. [03] Dynamic cushion 24-hour care 8

Precioso system Control unit HANDlINg AND OPERATINg THE system The Precioso system Control unit (scu) is designed with ergonomics and ease of handling in mind. It is easy to carry and easy to mount on the bed. The unique air connector socket is approached easily from above reflecting the natural carer s posture. simple to use front panel controls with their clear graphical symbols make operation easy to learn and remember. [01] [02] [03] [05] [04] [01] AlTERNATINg PREssuRE THERAPY (APT) mode Once turned on, the mattress automatically switches to alternating mode and adjusts the pressure inside mattress according to each individual patient s weight and position for their optimum pressure relief. [02] max INFlATE Provides fi rm and steady surface for various nursing procedures like wound cleaning, changing linen etc. It is equipped with an automatic safety time out to return the system to alternating mode after half an hour. [03] CONsTANT low PREssuRE (ClP) mode Five different settings enable the caregiver to select the best level for their patient based on their clinical judgment taking into consideration the physiological factors, bmi, body position, weight and their psychosocial needs. The scu automatically maintains the selected pressure regardless of changes in the patient s weight distribution or position. This achieves constant good levels of pressure redistribution. The smooth pressure adjustment cycle is designed for patient comfort with 2-stage reaction levels, allowing for large pressure changes caused by any sudden extreme increases in the mattress loading. [04] go button The go button concept with its 3 minute time out when controls have not been used lower the chance of human errors and allow the nurses to concentrate on delivery of care to the patient. [05] CusHION mode INDICATOR A visual indication on the front panel confi rms to the carer that cushion has been successfully connected. 9

Effortless delivery of care The ease of use, cleaning and maintenance features of Precioso make nursing and maintenance tasks as simple and fast to perform as possible. [01] Intuitive easy to use controls The use of easy to understand pictures & indicators together with simple push button controls, make the SCU easy for carers to use. Also minimises risk of incorrect operation and training requirements giving increased safety and staff efficiency. [01] Automatic Pressure adjustment Fully automatic cell adjustment ensures optimum patient protection and easy system installation. 02 [02] Removable comfort layer Separate mattress internal layer adds to patient comfort. Easy to remove for cleaning or replacement. [02] [03] Air deck construction The construction of the connected cells increases the therapeutic effect of the system and comfort for the patient. It prevents the patient from bottoming out and slipping between the cells. Also facilitates ease of cleaning and disinfection. [03] 10

Effortless performance of service based on many years of experience supporting mattress in different healthcare settings worldwide, we have developed our service features to make your engineers life easier and keep repair costs down. [04] REPAIR strategy Three level repair strategy, patches, single cells or modules, enables cost effective mattress air cell and cover maintenance. Patch cell Patch cover [05] service DATA INTERFACE unit (sdiu) service Data Interface unit (sdiu) with infrared connection helps keep maintenance costs and times down to a minimum. use cell insert Replace cover top/bottom TECHNICAl PARAmETERs mattress dimensions 2000 860 170 mm Overlay dimensions 2000 860 130 mm Cushion dimensions 450 500 125 mm scu dimensions 136 360 290 mm max. patient weight 160 or 210 kg mattress weight (including compressor) Overlay: 9 kg mattress: 11,3 kg Replace cell module group [04] 3 level repair strategy Replace complete cover ElECTRICAl PARAmETERs Feed 220/240 Vac 50 Hz Electrical safety EN 60601-1 Protection against electrical Class II, Type b current [05] 11

Prevention and therapy for everybody, everyday Želevčice 5, 274 01 Slaný, Czech Republic tel.: +420 312 576 111, fax: +420 312 522 668, e-mail: info @ linet.com, www.linet.com 04/2013 9601-1032