University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

Similar documents
BREATHE SAFELY: The Proper Use of Respiratory Protection

Respiratory Protection Program 29CFR

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Respiratory Protection Program

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

HOW TO USE A RESPIRATOR

A. Evaluation of the written program

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

University of Dayton Respiratory Protection Program 29 CFR

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

RESPIRATORY PROTECTION PROGRAM

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

RESPIRATORY PROTECTION

Respiratory Protection. Program

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

"RESPIRATORY PROTECTION AND SAFETY"

VFlex 9105/9105S Particulate Respirator N95

RESPIRATORY PROTECTION PROCEDURE

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Particulate Respirator N95

Respiratory Protection Self Inspection Checklist

Respiratory Protection

N95 Respirator Fit-testers Training. UMDNJ Office of Environmental Health & Safety Services (EOHSS)

Respiratory Protection Training

3 Choosing the Right Respirator

Standards of Practice Respiratory Protection: Appendix C

RESPIRATORS & FIT TESTING

Respiratory Protection Self-Inspection Checklist

"RESPIRATORY PROTECTION AND SAFETY"

8200/07023 Particulate Respirator N95

Respiratory Protective Equipment Program Appendix A - Definitions and Key Terms

Respiratory Protection

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

Respiratory Protection

EP30g, Respiratory Protection.pdf

PPE Refresher Using your SCBA

RESPIRATORY PROTECTION PROGRAM

Respiratory Protection in Agriculture

RESPIRATORY PROTECTION PROGRAM

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference)

The Following information is based on material prepared by the American Lung Association

National Personal Protective Technology Laboratory

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

Phalanx Alpha Phalanx Beta and Ultra Elite

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

Respirator Awareness. Overview of Respiratory Standard and Considerations for Choosing a Respirator Focusing on Non-IDLH; Air Purifying Respirators

Respiratory Protection for Producers

9210/37021, 9211/37022* Particulate Respirator N95

Respiratory Protection Written Program

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

A. APPLICATIONS 1. WARNING TO USER

Ontario Operations PMP - Daily Safety Message. Respirator Safety

OSHA s Respiratory Protection Standard 29 CFR

Respiratory Protection Basics

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Respiratory Protection

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Personnel Protective Equipment

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM FOR SOUTHEAST MISSOURI STATE UNIVERSITY CAPE GIRARDEAU, MISSOURI

San Mateo County Health System Environmental Health Services Division. Respirator Use

Respiratory Protection Program

Respiratory Protective Equipment: An Employer s Guide

Respiratory Protection Program

Using a Filtering Facepiece Respirator

Central Washington University

HAZWOPER 8-Hr Refresher Aug. 20, 2012

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

RESPIRATORY PROTECTION SAFETY PROGRAM

Respiratory Protection Programs Policy

East Brunswick Fire District #1

Respiratory Protection

Personal Protective Equipment 29 CFR 1926

29 CFR Part Compliance Made Easier

Barry Sanders has the following disclosures to make:

Section 3. Respiratory Protection Plan (SPPM 3.24)

Respiratory Protection Program

RESFT 101 Intro to Quantitative Fit Testing

How to Comply With the 2015 Revised Worker Protection Standard For Agricultural Pesticides. What Owners and Employers Need To Know

Respiratory Protection

City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015

When you have completed this exercise, you will be better able to: Demonstrate checkout, donning and doffing of your SCBA

Respiratory Protective Equipment: An Employer s Guide

Michael Pate Utah State University

Respiratory Protection Program

Helping protect people At work, at home, for life

West Clinton Fire District

How to Make a Respirator Program and Calculating the Cost

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Respiratory Protection Program

WRITTEN RESPIRATORY PROGRAM:

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

RMM 311 Respiratory Protection Program Page 2 March 2013

Safety Best Practices Manual

Transcription:

University of Alabama Office of Environmental Health and Safety Respirator Protection Training

Medical Reasons That Could Prohibit the Use of a Respirator A history of pulmonary or lung problems such as: Asbestosis, asthma, COPD, emphysema, TB, silicosis, shortness of breath, etc. Do not use a respirator if you have any health or respiratory problem until you obtain clearance from a Physician or other Licensed Health Care Professional.

Other Reasons Not to use a Respirator Beards, stubble, or sideburns will prevent a good facepiece seal. Do not use any respirator unless you are clean-shaven. No exception to this rule If you have facial hair you will not be fit tested

Who uses respirators? An estimated 5 million workers are required to wear respirators in 1.3 million workplaces throughout the United States. Respirators protect workers against insufficient oxygen environments, harmful dusts, fogs, smokes, mists, gases, vapors, sprays and biological hazards. These hazards may cause cancer, lung impairment, other diseases, or death.

If Worn Properly. An air purifying respirator will reduce, but not eliminate the inhalation of contaminants. Does not supply oxygen. Does not totally eliminate exposure to or risk of contracting any disease or infection.

Selection of Respirators Employer must select and provide an appropriate respirator based on the respiratory hazards to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.

Tight -Fitting Coverings Quarter Mask Half Mask Full Facepiece Mouthpiece/Nose Clamp (no fit test required)

Loose-Fitting Coverings Hood Helmet Loose-Fitting Facepiece Full Body Suit

Negative Pressure Respirator A respirator in which the air pressure inside the facepiece is negative during inhalation with respect to the ambient air pressure outside the respirator.

Filtering Facepiece A negative pressure particulate respirator with a filter as an integral part of the facepiece or with the entire facepiece composed of the filtering medium. (Dust Mask)

Air-Purifying Respirator (APR) A respirator with an air-purifying filter, cartridge, or canister that removes specific air contaminants by passing ambient air through the airpurifying element.

Your Respirator EHS recommends the Survivair Series 2000 Halfmask Dual Cartridge respirator. They come in small, medium, and large sizes. We maintain a supply of parts, cartridges, and respirators for most situations.

Survivair Series 2000 Respirator Lightweight silicone construction Comfortable User friendly Fits a variety of face shapes and sizes Cartridges available for a wide range of contaminants

Survivair Series 2000 Respirator When properly fitted, has a APF of 10

Assigned Protection Factor (APF) The workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer implements a continuing, effective respiratory protection program as specified in this section.

Assigned Protection Factors (APF s) Must use the APF s listed in Table 1 to select a respirator that meets or exceeds the required level of protection When using a combination respirator (e.g., airline with an airpurifying filter), must ensure that the APF is appropriate to the mode of operation in which the respirator is being used

TABLE 1 ASSIGNED PROTECTION FACTORS 5 Respirator Type 1, 2 Quarter Mask Half Mask Full Face Helmet/Hood Loose-Fitting Air Purifying 5 3 10 50 ----------------- ----------------- PAPR -------------------- 50 1,000 4 25/1,000 25 SAR! Demand! Continuous Flow! Pressure Demand/ other (+) pressure -------------------- -------------------- -------------------- 10 50 50 50 1,000 1,000 --------------------- 4 25/1,000 --------------------- -------------------- 25 -------------------- SCBA! Demand! Pressure Demand/ other (+) pressure -------------------- -------------------- 10 ------------------ 50 10,000 50 10,000 -------------------- -------------------- 1 May use respirators assigned for higher concentrations in lower concentrations or when required use is independent of concentration. 2 These APF s are only effective when employer has a continuing, effective respirator program per 1910.134. 3 This APF category includes filtering facepieces and elastomeric facepieces. 4 Must have manufacturer test evidence to support an APF of 1,000 or else these respirators receive an APF of 25. 5 These APFs do not apply to escape-only respirators. Escape respirators must conform to 1910.134(d)(2)(ii) or OSHA s substance specific standards, if used with those substances.

Prior to use A written respiratory program must be implemented User must be medically fit to use a respirator Have had adequate training for the hazard they are to be subjected to Must be trained in the use of intended respirator Must be fit tested

Prior to donning respirator Select the appropriate size, a medium fits most people. Only a secure snug fit protects you, so make sure you have the correct size. The shape of your face, facial hair and condition of your skin can affect your fit. Inspect the respirator for defects.

Respirator Parts Facepiece Exhalation valve Inhalation valve Straps

Inhalation Valves

Exhalation Valve

Determine the adequacy of the (a) Chin properly placed; respirator fit: (b) Adequate strap tension, not overly tightened; (c) Fit across nose bridge; (d) Respirator of proper size to span distance from nose to chin; (e) Tendency of respirator to slip; (f) Self-observation in mirror to evaluate fit and respirator position.

Donning the Respirator 1. Connect bottom strap around your neck. 2. With one hand, hold the respirator to your face. 3. While holding the respirator in place, slip the head harness over your head. 4. Adjust and tighten the head harness straps until the respirator fits snugly to your face. The best way to tighten a respirator is to tighten the straps from the bottom up. To be sure that you know how to don the respirator properly, you should demonstrate donning the respirator to your supervisor or safety professional.

A properly donned Survivair 2000 dual cartridge half mask facepiece. To be properly donned, the respirator must be correctly oriented on the face and held in position with both straps. The straps must be correctly placed, with the upper straps high on the head and the lower strap below the ears. For persons with long hair, the lower strap should be placed under (not over) the hair.

RESPIRATOR FIT CHECKS Perform both a Positive Pressure Seal Check and a Negative Pressure Seal Check

Positive Pressure Seal Check Begin by closing the respirator's exhalation valve by covering it with your hand, then breathe out slowly. The facepiece will bulge out slightly. Hold your breath for about 10 seconds. If during this time no air leaks from around the facepiece, you know you have a good fit. If you do not have a good fit, readjust the head harness straps, and repeat the pressure test.

Negative Pressure Seal Check Begin by closing the respirator's inhalation valves with your hands, then breathe in slowly. The facepiece will collapse slightly. Hold your breath for about 10 seconds. And if during this time no air leaks in from around the facepiece, you know you have a good fit. If you do not have a good fit, readjust the head harness straps, and repeat the pressure test.

Fit Test A qualitative fit test (yes it fits or no it does not fit) is used. Dependent on the detection of a saccharin (sweet) tasting mist.

What is done? Sensitivity Test This test is done to assure that the person being tested can detect the sweet taste of the test solution at very low levels. The Sensitivity Test Solution is a very dilute version of the Fit Test Solution. The test subject should not eat, drink, or chew gum for 15 minutes before the test.

The test hood is placed over the subject s head (without the respirator on) and the sensitivity solution is misted inside to make sure the subject can detect the test solution. Sensitivity Test

The subject dons the respirator, the hood is again placed over the head and the Fit Test Solution (a very concentrated saccharin solution) is misted into the hood. Next

The subject is asked to perform several exercises, normal breathing, deep breathing, turning their head side to side and up and down. Finally they are asked to read the Rainbow Passage. If the test solution is not detected during these exercises the subject has a properly fitted respirator. And Last

Monitoring Your Respirator As you work, you must not only monitor the seal around your face, but you must also monitor how well your respirator is working. You will know that your respirator is not working when: You can smell or taste the contaminant Breathing becomes difficult You become dizzy or sick feeling The manufacturer's recommended service life of the filters or cartridges expires The respirator is damaged WARNING: Never use or continue to use a respirator that is not working perfectly.

Monitoring Your Respirator After using your respirator, you should clean and inspect it. A mild soap and water solution is usually sufficient for cleaning but a disinfectant should be used periodically also. As you clean, be sure to look for: Worn or frayed straps Worn or damaged fittings Broken buckles Improperly seated or cracked valves

Monitoring Your Respirator If you find ANYTHING wrong with your respirator, have it repaired or replaced immediately! NEVER knowingly use a malfunctioning or broken respirator or cartridge NEVER use parts or cartridges not specifically designed for use with your respirator Do not leave your respirator hanging from the straps for extended times

Storing Respirators After cleaning and thoroughly drying your respirator, place it in a sealable plastic bag away from: Dust Sunlight Heat Extreme cold Moisture Damaging chemicals

Cartridge Service Life The problem is Cartridges designed for the Survivair 2000 respirator do not have a end-of-service-life indicator (ESLI), i.e. a colored area or spot on the cartridge that changes color to indicate the cartridge needs replaced. No one works in an area with a consistent level of contamination.

Cartridge Service Life So.. Change cartridges at least yearly More often if you smell/taste the contaminant or breathing becomes difficult.