490 Micro GC Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

490 Micro GC Site Preparation Checklist

Customer Responsibilities

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

DD2 Site Preparation Checklist Hardware Site Preparation Specification

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

6890 GC Site Preparation

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

Series Environmental Chambers

UltraLo 1800 Alpha Particle Counter

AB SCIEX QTRAP 4500 System

Xcalibur, Gemini. User Manual. [Instrument version from September 2013 onwards] X-ray Diffractometer Systems. Version 2.

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Avio 500 ICP-OES. ICP-Optical Emission Spectroscopy PREPARING YOUR LAB. Preparation Checklist. Suitable Working Area

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Miris Ultrasonic Processor

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Columbus Instruments

Your local gas generation partner. Precision series Modular gas generation solution for GC.

SonoMeter 30 Energy Meters

Varian 240-MS GC/MS Ion Trap Mass Spectrometer Pre-installation Instructions

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Preparing Your Laboratory for the Optima 7300 V and 8300 ICP-OES Spectrometers

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

HumiSys HF High Flow RH Generator

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist

Varian 400-MR Magnetic Resonance Spectrometer Pre-installation Instructions

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

User Manual. Quantos Automated Dosing Liquid Module

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

7820A GC Site Preparation Checklist

GasSense NDIR User Manual

APEX TM III MASS SPECTROMETER SITE GUIDE AND PRE-INSTALLATION INSTRUCTIONS

Oxford Instruments Plasma Technology

PRC CO ² -LASER PRESENTATION


RPS900W Redundant Power Supply. Installation Guide.

Pneumatic spool valve islands

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Preinstallation Checklist and Instructions for the TriStar These Preinstallation Checklist and Instructions were reviewed and approved by:

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Pneumatic high-pressure controller Model CPC7000

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

Additel 780 Series Pressure Controller

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Cryostream 800 Series

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

NGN Series nitrogen generator

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Pressure Automated Calibration Equipment

Recirculating Coolers

Pneumatic high-pressure controller Model CPC7000

Workhorse-15 Oxygen Generator

VACUUM REGULATORS CONTENTS

Microscopy Cryogenic WORKSTATION. Performance by Design

Genesis MX SLM-Series

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Electro-Pneumatic Converter YT-940 SERIES

HYDRAULICS. H89.8D - Hydraulic Bench

PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Technical Information

High Pressure Breathing Air Compressors

Variable Temperature Storage Dewar Mount Inserts

Current Leads for Cryogenic Systems

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

TA Instruments Installation Requirements for the Thermal Discovery Series

IMPORTANT SAFETY INSTRUCTIONS

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Digital Vacuum Regulator

Nitrogen Supply System

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

Additel 780 Series Pressure Controller

Ultrasonic level transmitter and indicator

New AQF Filter Polymer Filtration System

User Manual. Agilent 1260 Infinity Analytical- and Preparative-scale Fraction Collectors

Pneumatic valve islands

Pre-installation Checklist

THE WATER-COOLED INDUSTRIAL RANGE

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Transcription:

Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the key first step in ensuring that your instruments and software systems operate reliably over an extended lifetime. This document is a checklist AND information guide prepared for you that outlines the supplies, consumables, space and utility requirements for your equipment for your site. Customer Responsibilities Make sure your site meets the following prior specifications before the installation date. For details, see specific sections within this checklist, including: Guidance When completing the relevant checkboxes in the checklist using a X or tick mark, please note that "X" stands for FAIL and for PASS. The site meets the requirements for Instrument space dimensions, floor loading and door access as describe in the Section 1 - Dimensions and Weights below. The Laboratory where the instrument will be located meets the environmental conditions for Temperature and water requirements as described in Section 2 Environmental Conditions The Power in the Laboratory meets the requirements for location, voltage/ current rating and number of socket outlets as described in Section 3 Power consumption Additional item to be made available by the customer at the time of installation including a suitable high vacuum pump, ideally 70 Litres/sec turbo molecular pump, water to the correct specification and Liquid Nitrogen or Helium to the correct purity as described in Section4 - Additional requirements to be supplied by the customer. An Uncompensated Geiger Muller tube radiation monitor should be available to carry out a critical examination of the equipment. Please consult Other Requirements section below for other product-specific information. For more details, please consult the product-specific Site Preparation. If Agilent is delivering installation and familiarization services, users of the instrument should be present throughout these services; otherwise, they will miss important operational, maintenance and safety information. Issued: 03-Dec-2014, Revision: 2.3 Copyright 1 2014 Agilent Technologies Page 1 of 2

Important Customer Information 1. If you have questions or problems in providing anything described as a Customer Responsibilities above, please contact your local Agilent or partner support/service organization for assistance prior to delivery. In addition, Agilent and/or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory. 2. Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to re-arrange any services that have been purchased. 3. Other optional services such as additional training, operational qualification (OQ) and consultation for user-specific applications may also be provided at the time of installation when ordered with the system, but should be contracted separately. Important Customer Web Links and contact information How to get information on your product? - http://www.agilent.com/chem/xrd Need to know more? - customer Education http://www.agilent.com/chem/education Need technical support, FAQs? - http://www.chem.agilent.com/en-us/technical- Support/Pages/default.aspx Need supplies? - Please contact your local call center NOTE: Please use your local call centers when contacting us for any Sales & Service related questions quoting your system type and serial number. Site Preparation Completion Date completed Customer signature Issued: 03-Dec-2014, Revision: 2.3 Copyright 2 2014 Agilent Technologies Page 2 of 2

Section 1 - Dimensions and Weight Identify the laboratory space before your system arrives based on the content below. Pay special attention to the total height and total weight requirements for all system components you have ordered. Also pay special attention to the total weight of the modules you have ordered to ensure your laboratory floor can support this weight. Fig.1 SuperNova Suggested Layout Issued: 03-Dec-2014, Revision: 2.3 Copyright 1 2014 Agilent Technologies Page 1 of 6

1. Ceiling should be minimum 2.3m high. 2. Floor able to bear the system weight of about 500kg over an area of 0.48m2. 3. Floor should be flat and horizontal within a tolerance of 3mm. 4. Adequate space is required around the system for servicing. The minimum clearance from the walls and a suggested system layout are shown in drawing above (Fig.1). 5. For the air cooled configuration Air Cooler unit, or for any additional third party chiller, an extra space of footprint 70 cm x 50 cm is required close to the system. 6. Unpacked, the largest subassembly will fit through a door aperture of 90 cm. Check the door aperture to ensure the system can be assembled in its designated area (Tab.1) 7. Packed largest box will fit through door and elevator aperture of 125cm. Check the door and elevator size in areas where boxes will be storage or transport (Tab.2) 8. When the low temperature option is fitted an extra 100 cm space on the left-hand side of the system is required. 9. An engine hoist or several people should be available to help with assembly. 10. Table should be provided for PC and monitor if not ordered from Agilent. 11. If temperature controllers ordered table for controllers should be provided. Tab.1 Largest system components Weight Height Depth Width Instrument Description Kg lbs cm in cm in cm in Kappa Goniometer 106 234 64 25 47 19 43 17 Protection cabinet 120 265 72 28 92 36 100 39 Electronics rack 140 309 104 41 77 30 60 24 Option devices Weight Height Depth Width Kg lbs cm in cm in cm in Air Cooler 25 55 93 37 32 13 70 30 Helijet Head 10 22 25 10 10 4 30 12 Helijet transfer line 3 7 150 60 6 2,5 250 98 ILM210 5 11 10 4 30 12 44 17 Mercury ITC 5 11 10 4 30 12 44 17 GFC1 12 27 26 10 38 15 45 18 Tab.2 System will be shipped with boxes Issued: 03-Dec-2014, Revision: 2.3 Copyright 2 2014 Agilent Technologies Page 2 of 6

Approximate Boxed Weights Weight Height Depth Width Kg lbs cm in cm in cm in Goniometer 160 353 90 35 95 37 60 24 Electronics rack 195 408 138 54 92 36 77 30 Protection cabinet 240 528 100 39 115 61 105 39 X-ray source(s) / CCD detector Option devices 122 270 105 41 100 39 90 35 Weight Height Depth Width Kg lbs cm in cm in cm in Air Cooler 92 198 90 36 107 42 50 20 LN2 Dewar 120 265 155 61 70 28 70 28 Cryojet 145 320 190 75 70 28 80 31 Helijet 90 198 55 22 60 24 95 37 Section 2 -Environmental Conditions Operating your instrument within the recommended temperature ranges insures optimum instrument performance and lifetime. Tab. 3 Instrument operating temperature range Instrument Description Operating temp range C (F) SuperNova 18-25 (64-77) Air Cooler 18-25 (64-77) Helijet Head 18-28 (64-82) Cryojet Head 18-30 (64-86) ILM210 18-30 (64-86) Mercury ITC 18-30 (64-86) GFC1 18-28 (64-82) Operating humidity range (%) 30-75 without 30-75 without 30-75 without Heat Dissipation (BTU) 4000 2050 N/A N/A 103 342 342 Issued: 03-Dec-2014, Revision: 2.3 Copyright 3 2014 Agilent Technologies Page 3 of 6

Tab. 4 Instrument storage temperature range Instrument Description Storage temp range C (F) SuperNova 10-40 (50-104) Air Cooler 10-40 (50-104) Helijet Head 10-40 (50-104) Cryojet Head 10-40 (50-104) ILM210 10-40 (50-104) Mercury ITC 10-40 (50-104) GFC1 10-40 (50-104) Storage humidity range (%) Heat Dissipation (BTU) 1. SuperNova may be cooled using either ambient air or an external water supply. This decision must be made at the time of ordering to enable the system to be pre-configured before shipment. 2. Performance can be affected by sources of heat & cold e.g. direct sunlight, heating/cooling from air conditioning outlets, drafts and/or vibrations. 3. The site s ambient temperature conditions must be stable for optimum performance. Stability of ambient temperature during operation should be about ± 1 C. 4. Clean location, dust free environment > 2m from air conditioning or heating units. Cooling water supply line Tab. 5 Cooling circuit parameters Min flow rate 1.8 l/min Supply Line Pressure 3-5 bar gauge Return Line Pressure Maximum of 1 bar Temperature stability Temperature range ± 5 C 10 20 C Composition Filtered, without deposits, chemically neutral and optically clear 1. This is only required if the SuperNova is not to be used with the Air Cooler or third party chiller. 2. Take care to check Return Line Pressure on closed loop water systems 3. Note: If the external cooling water for the SuperNova system is to be supplied by a third party chiller, this circuit should incorporate its own bypass valve system as the SuperNova Chiller will Issued: 03-Dec-2014, Revision: 2.3 Copyright 4 2014 Agilent Technologies Page 4 of 6

only take water as and when it is required. The third party chiller supply pressure must be set to 3 bars. Section 3 -Power Consumption Tab. 6 Instrument line voltage Instrument Description Line Voltage (V) Frequency (Hz) Fuse Rating (A) SuperNova (computer, goniometer, interface, water chillers etc.) SuperNova*US (computer, goniometer, interface, water chillers etc.) SuperNova (temperature attachments, etc) SuperNova *US (temperature attachments, etc) 3 x single phase outlet 208-240 (± 10 %) 3 x single phase outlet 115-120 (± 10 %) 4 x single phase outlet 208-240 (± 10 %) 4 x single phase outlet 115-120 (± 10 %) 50/60 Hz ±5% 60 Hz ±5% 1 x 16 Amp - system 1 x 16 Amp - PC + monitor 1 x 20 Amp - system 1 x 20 Amp - PC + monitor 50/60 Hz ±5% 1 x 13 Amp 60 Hz ±5% 1 x 20 Amp 1. US Voltage ~115V is optional (to be requested at the time of ordering). 2. Outlets location should be on wall behind the system. 3. Common Earth should be supplied for all connections <0.5 Ohm. 4. Circuit breaker should be fitted to all outlets. 5. Fit a line voltage regulator if the power supply voltage fluctuates more than ±10 %. 6. In areas where the electrical power supply is unreliable an uninterruptible power supply (UPS) is recommended. The UPS should have minimum specifications of 2200VA with single phase output. Section 4 - Additional requirements to be supplied by the customer 1. For information on Agilent consumables, accessories and laboratory operating supplies, please visit http://www.chem.agilent.com/en-us/products/consumables/pages/default.aspx 2. The distance between the water supply and the chiller is not limited but the supply must deliver 3-5 bar gauge pressure with a minimum 1.8 liters/min flow or supply pressure regulator must be Issued: 03-Dec-2014, Revision: 2.3 Copyright 5 2014 Agilent Technologies Page 5 of 6

fitted and set to 3 bar. 3. The water supply should have a wall mounted shut off valve. 4. A turbo molecular pump, capacity 70 liters/sec is REQUIRED before each use of the Helijet, and must be supplied if not purchased as part of the system. 5. Liquid nitrogen and/or helium should be available during the installation to enable the low temperature attachments to be tested / demonstrated. 6. If the seismic resistant plate was purchased appropriate mounting should be present to allow attaching seismic plate to the floor. Required holes should be prepared in the floor prior the installation. Bottom view of SuperNova system with seismic resistant plate is shown on the picture below. Seismic resistant plate thickness is 15mm. Mounting holes diameter is 15mm. Fig.2 Seismic resistant plate Gas Options Purity Regulator Minimum pressure Flow rate Helijet, Ultra optics low pressure 0.5 bar gauge 30-40 cm3/min @ Helium 99.95% regulator ATP Liquid Options Purity Quantity Helium Helijet 99.99% 50L Nitrogen Nitrogen powered LTs Up to 75L Issued: 03-Dec-2014, Revision: 2.3 Copyright 6 2014 Agilent Technologies Page 6 of 6