Installation Instructions

Similar documents
ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

LAZY RIVER 3 3 PUMP LOCATION

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Hydrotherapy Jets System for a Fiberglass Pool

Installation of Your SprayMaster System

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

Office Use Only Fee Paid

To purchase replacement parts and accessories, or to obtain technical assistance, visit:

SINGER MODEL 106/206-RPS-L&H

Providing quality commercial equipment since 1998 for pool, spa, fountain and spray ground

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

PRO SINK -R 1 and 2. Dilution system CONTENTS

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

Pressure Compensating (PC) Spray Stakes

Intelligent pool systems. Line of Unique Systems and Products

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

GATE INSTALLATION INSTRUCTIONS

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

COUNTER CURRENT UNIT. Instruction Manual

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Inflatable Dock Slide Owner s Manual

BS Series Basket Strainer

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

6900 Professional Parkway East, Sarasota, FL Phone Fax Certificate of Authorization #43 FL Lic.

Nicheless LED Lighted Bubbler

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

icon i150 / i350 Installation / Operation Manual

Air Operated Hydraulic Pumping Systems to 50,000 psi

FOAM FRACTIONATORS. Also Known As. Phoam Phraxtionators Protein Skimmers Air Strippers

INSTALLING AN INEXPENSIVE AIR LINE TO MEASURE WATER DEPTHS IN WELLS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

WATERFALLS DECK JETS SCONCES. Waterfall, - Cut the waterfall notch in the inner edge of the bond beam at the stee tive cover nd protec a

Chlorinator MODEL MK-I

STATIONARY SERIES 1/2 HP - 40 HP. UAB STELSA

Table of Contents. We also carry a wide range of supplemental products for splash pad systems and pools.

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SINORIX Valve Reconditioning

Waterblade Installation Manual

American Flagpole & Flag Co. 1(800)

ROCKSOLID DUAL POST ANCHOR

Pontoon Slide Owner s Manual

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Troyer s Gourd Rack 8 unit F R H O P

IT S TIME TO PLAY! Owner s Guide A&A BUILT-IN POOL CLEANING AND CIRCULATION SYSTEMS

CENTER PIVOT EVALUATION AND DESIGN

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

RAINBOW CHLORINE/BROMINE FEEDER MODEL #320

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

GM Series Dual-Block Multi-Function Gas Control Valves

175 m2 (1,880 sq ft) Kit

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS

Aqua Pilot Suction Pool Cleaner

Installation and commissioning instructions 255 series and 256 series

MODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

HGC-200 Hydro Gas Chlorinator

Irrigation System Winterization and Pressurization Procedures

INSTALLATION INSTRUCTIONS

TROUBLESHOOTING GUIDELINES

Valves. Controllers. Valves Two Types

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

Head to Head Demo Comparison Sheet

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

STATIONARY TRUCK INTERNAL HALYARD CAM CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL COMMERCIAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

Digester Processes. 1. Raw Sludge Pumping System

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

ABRASIVE REGULATOR II

Bar valve with fixed shower head Installation guide

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

ROCKSOLID SINGLE POST ANCHOR

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

ABRASIVE REGULATOR II

Pressure Dump Valve Service Kit for Series 3000 Units

SIZING OF WATER PIPING SYSTEM

KENNEDY VALVE RESILIENT WEDGE GATE VALVE MAINTENANCE MANUAL

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Transcription:

Installation Instructions Splashdown Fountain The Splash Down telescoping fountainhead comes in two sizes: the SD22 for use in water depths from 6 to 24 inches and the SD44 for use in water depths of 25 to 48 inches. The preplaster installation instructions are identical for both sizes. See the POST-PLASTER INSTRUCTIONS for both of the telescoping fountainheads as well as for the WATER LILY and the CRYSTAL SPRAY. PRE-PLASTER INSTRUCTIONS 1. Determine the location of each Splash Down fountainhead and dig the necessary trenches to accommodate the 1½ feed lines to the fountainheads. Dig a vertical hole at least 25 to 26 deeper than the trench to accommodate the 24 long lower fitting. (See Figure 1) NOTE: Do not place a fountainhead any closer than 6 to the edge of a bench or shelf. 2. The trenches must be deep enough to allow the Tee in the fountainhead assembly to be at least 4 below the finished concrete (gunite or shotcrete) surface. 3. Each Splash Down fountainhead must be fed with a separate 1½ line and 1 brass gate valve. This is imperative to assure the proper adjustment of each individual fountainhead. 4. After the fountainhead has been glued in place, fill the dirt in around the lower fitting and feed lines making sure the unit remains plumb. 5. Just before installing the finished surface to the pool, cut the A&A risers flush with the concrete surface. This should be done at the same time the cleaning heads are set. 6. Using the same color floor fitting housing as used in the floor cleaning system, glue the fittings in place. (See Figure 2) 7. Do Not remove the plaster shield from the floor fitting housing until the finished surface has been applied to the pool. The fountainhead tube must be sized and cut after the pool is filled. WATER LINE WATER LINE FROM WATER SOURCE 1 1 2 " FEED LINE A&A RISER THIS TEE SHOULD BE A MIN. OF 4" BELOW CONCRETE SURFACE CUT THE A&A RISER FLUSH WITH THE CONCRETE SURFACE AND GLUE THE FLOOR FITTING IN PLACE BEFORE PLASTERING 24" A HOLE 25" TO 26" MUST BE DUG BELOW THE TEE TO ACCOMMODATE THE 24" LONG LOWER FI TTING. A&A Manufacturing o (602) 256 6935 t (800) 851 8482 f (602) 532 4896 3750 West Indian School Road Phoenix, Arizona 85019 aamfg.com Figure 1 Figure 2 Page 1 of 6 Rev20170719

POST-PLASTER INSTRUCTIONS SD22 Instructions 1. Remove the plaster shield from the floor fitting housing. After the pool is filled, measure the exact depth of the water at the fountainhead location. 2. With an A&A Installation tool (with 3 prongs), remove the fountainhead collar from the floor fitting housing. 3. Remove the fountainhead nozzle (see Figure 3) from the fountainhead tube and cut the tube to the length required for the nozzle to rise within 2 of the pool water surface. Cut the plain end of the tube opposite the end with the inlet fitting. Note! The SD22 is already sized for a 24 water depth. The fountainhead tube is 24 long, however, the floor fitting is 2 deep and absorbs 2 of the length. If the water depth is 18, cut the tube 18 long and the nozzle will automatically be 2 below the water surface. 4. IMPORTANT, before gluing the nozzle to the end of the sized fountainhead tube, insert the cut end of the tube up through the bottom of the fountainhead collar then glue the nozzle in place using clear PVC to PVC cement. (See Figure 4) 5. Reinstall the assembly by installing the collar back into the floor fitting housing. NOZZLE (GLUED IN PLACE FOUNTAINHEAD NOZZLE NOT GLUED FLOOR FITTING HOUSING AFTER CUTTING THE FOUNTAINHEAD TO LENGTH, GLUE THE FOUNTAINHEAD NOZZLE TO THE SIZED FOUNTAINHEAD TUBE. (USE A CLEAR PVC TO PVC CEMENT) SECONDARY FOUNTAIN HEAD TUBE 24" FOUNTAINHEAD TUBE Figure 4 NOZZLE COLLAR (NOT GLUED) STOP RING (NOT GLUED) INLET FITTING GLUED IN PLACE Figure 3 FLOOR FITTING INTERNAL SD44 Instructions 1. Follow steps #1 and #2 above. 2. Remove the Nozzle Collar from the Primary Fountainhead Tube (see Figure 5) and lift the Secondary Tube out of the Primary Tube then remove the Stop Ring. 3. At full extension, the SD44 rises 45 above the Floor Fitting Housing. Therefore, if the water depth is less than 47 the Secondary Tube must be cut off accordingly. Example: If the water depth at the Floor Fitting Housing is 36, the Secondary Tube must be cut off 11. (47-36 =11 ) 4. It is IMPERATIVE that the following assembly sequence be followed: Figure 5 PRIMARY FOUNTAIN HEAD TUBE INLET FITTING GLUED IN PLACE Page 2 of 6

POST- PLASTER INSTRUCTIONS (Cont.) A. Insert the Secondary Tube down through the Nozzle Collar and glue the Stop Ring in place with a clear PVC to PVC cement. B. Insert the Primary Fountainhead Tube up through the Floor Fitting Internal, then insert the Secondary Tube down into the Primary Tube and glue the Nozzle Collar onto the top of the Primary Tube using clear PVC to PVC cement. C. Reinstall the assembly into the Floor Fitting Housing and lock in place with an A&A Installation Tool. Water Lily Instructions 1. NOTE! Due to the delicate water pattern that this fountain head forms, the Water Lily is not recommended for windy locations. 2. Remove the plaster shield from the floor fitting housing. After the pool is filled, measure the exact depth of the water at the fountainhead location. 3. With an A&A Installation Tool (with 3 prongs) remove the fountainhead collar from the floor fitting housing. 4. Remove the fountainhead nozzle (see Figure 3) from the fountain head tube and cut the tube to the desired height of the Water Lily Fountain. Since the tube is 24 long, the maximum height possible is 18 above the water level in an area where the water depth is a maximum of 6 deep. If an 18 fountain is desired the tube does not need to be cut. Simply glue the fountain head to the 24 tube. For proper effect, do not exceed 18 above water. 5. IMPORTANT, before gluing the nozzle to the end of the sized fountainhead tube, insert the cut end of the tube up through the bottom of the fountainhead collar then glue the nozzle in place using clear PVC to PVC cement. (See Figure 4) 6. Reinstall the assembly by installing the collar back into the floor fitting housing. Use special spanner wrench supplied. Crystal Spray Instructions 1. Remove the plaster shield from the floor fitting housing. After the pool is filled, measure the exact depth of the water at the fountainhead location. 2. With an A&A Installation tool (with 3 prongs), remove the fountainhead collar from the floor fitting housing. 3. Remove the fountainhead nozzle (see Figure 3) from the fountainhead tube and cut the tube to the length required for the nozzle to rise 1 above the pool water surface. Cut the plain end of the tube opposite the end with the inlet fitting. 4. IMPORTANT, before gluing the nozzle to the end of the sized fountainhead tube, insert the cut end of the tube up through the bottom of the fountainhead collar then glue the nozzle in place using clear PVC to PVC cement. (See Figure 4) 5. Reinstall the assembly by installing the collar back into the floor fitting housing. Page 3 of 6

How to Determine Fountain Base Size The following drawing and chart are provided so that you can determine how close you may install the Splash Down Fountain to a pool edge. The higher the desired peak of the fountain, the further the fountainhead must be installed from the pool edge. D R Splashdown (Column) Height Radius Diameter 2-0 3-0 6-0 2-6 3-9 7-6 3-0 4-6 9-0 3-6 5-3 10-6 4-0 6-0 12-0 H Crystal Spray @ 7gpm Height Radius Diameter 40 27 54 Water Lily Height Radius Diameter 20 12 24 To Use the Above Chart: 1. Determine the desired fountain height you are trying to accomplish. 2. Find that height in the left column of the above chart and in column #2 you will find the approximate minimum distance the fountainhead must be installed from the pool edge. Any closer and the water from the fountain will fall on the deck of the pool. 3. Column #3 shows the diameter of the entire fountain base. 4. Example: If you desire a fountain height of 2-0 the fountainhead must be at least 3 feet from the pool s edge and the diameter of the fountain base will be 6-0. 5. Minimum water depth is 6 inches maximum water depth for the SD22 is 24 inches and for the SD44 the maximum water depth is 48 inches. 6. You cannot place a fountainhead any closer than 6 inches to the edge of a bench or shelf. 7. Approximately 8 GPM is required for each fountainhead. 8. Splash Down Fountains must be installed parallel to the water line in areas such as bench shelves, extended steps (other than the 1st step), spa floor, etc. Do Not install them in the pool floor, radii or side walls. 9. The fountain housing must be plumbed and set at a perfect 90 angle so that the fountain comes up in a perfectly vertical column. Note: In the above drawing, the radius and diameter boundaries appear to be twice as large as the fountain column of water. The additional area is required to contain any intermittent sprays and splashes. Page 4 of 6

Splash Down Fountains With In-Floor Cleaning Splash Down Header Details 1. Note that the feed line to the Splash Down Fountain interrupts the feed line to the wall returns. Do not interrupt the line to the cleaning system. 2. If more than one fountain is installed, run a separate line for each with its own 1 brass gate valve. This will allow for individual adjustment, assuring the desired fountain height and effect of each. 3. It is necessary for a ball valve or 2-way valve to be installed between the fountain feed lines and the wall returns so that fountain water heights may be individually adjusted. (See Figure 6) 4. Do not use a 2-way or 3-way valve in place of the gate valve to feed the fountains. These valves would allow rapid opening of the feed line making it possible to damage the fountainheads. THREE WAY VALVE BALL VALVE OR TWO WAY VALVE 3 2 FROM FILTER R R POOL WALL RETURNS G TO IN-FLOOR WATER VALVE 1" LINE 1" BRASS GATE VALVE 1 1 2" LINE TO FOUNTAIN Splash Down Fountains With Wall Returns 1. Note that the feed line interrupts the return line ahead of the ball valve or 2-way valve feeding the wall returns. (See Figure 7) 2. If more than one fountain is involved, install a feed line and 1 brass gate valve for each fountain. This will allow individual adjustment for the water height of each fountain. 1" LINE 1 1 2" BALL VALVE OR TWO WAY VALVE G 2 2" LINE TO WALL RETURNS 1" BRASS GATE VALVE 1 1 2" LINE TO FOUNTAIN Splash Down Fountains With a Separate Booster Pump 1. If a separate pump is used to feed the Splash Down Fountain or Fountains, it will be necessary to run a feed line to wall returns as well. (See Figure 8) 2. Since each fountainhead will use approximately 8 gpm, it is necessary to have a means for discharging any excess water from the booster pump. 3. If more than one fountainhead is being supplied from the booster pump, it is essential that each fountainhead be supplied by its own feed line and brass gate valve. This will allow for the individual height adjustment of each Splashdown fountain. BOOSTER PUMP 1" LINE 2 S SUCTION GRATES S G 1" BRASS GATE VALVE 1 1 2" BALL VALVE OR TWO WAY VALVE R R POOL WALL RETURNS 1 1 2" LINE TO FOUNTAIN Page 5 of 6

WATER LINE A&A RISER FROM WATER SOURCE 1 1 2 " FEED LINE THIS ELBOW SHOULD BE MIN. 4" BELOW CONCRETE SURFACE Bubble Jet Detail Page 6 of 6