Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Similar documents
Installation Effects on Ultrasonic Flow Meters for Liquids. Jan Drenthen - Krohne

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

The ERCB Directive 017 Overview

Influence of Reynolds number on Cd of Critical flow venturi nozzle and validation with ISO standards

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

Gas Measurement Fundamentals Certification. Curriculum

Truck-mounted Mass Flow Metering for LPG Delivery

Case Study Results on Natural Gas Custody Transfer Measurement with Coriolis Meters in Saudi Arabia

Oil and Gas Custody Transfer

Recalibration of gas meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Measurement & Analytics Wet gas monitoring

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

OIL AND GAS INDUSTRY

Vehicle-mounted meters, pump supplied

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246)

Metering Code Gas TSO, measurement by connected party Effective from to the present

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Valve actuation at the world s largest flow metering calibration facility

Cold-acclimatised pipelines

CORESTA RECOMMENDED METHOD N 6

Drilling Efficiency Utilizing Coriolis Flow Technology

Calibrating and Monitoring MUSMs in Natural Gas Service

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion Pressure Drop Testing

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Study of Thermal Effect on Calibration of an Ultrasonic Flow Meter

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

The Discussion of this exercise covers the following points:

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS

Instruction Manual. Pipe Friction Training Panel

Vehicle- or rack-mounted liquefied gas meters, pump supplied

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

Products Solutions Services. Gas Flow Measurement

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Traceable calibration of automatic weighing instruments in dynamic operation

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Gerald D. Anderson. Education Technical Specialist

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

SINGLE VALVE WITH LOW-FLOW BYPASS

Manual of Petroleum Measurement Standards Chapter 6 Metering Assemblies Section 3A Pipeline and Marine

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Chapter 22 Testing Protocols

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

An innovative technology for Coriolis metering under entrained gas conditions

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Organisation Internationale de Métrologie Légale

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

White Paper August , Rev AA

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

8:30 am 10:00 am Calculation of Petroleum Prover Quantity Calibration (COLM Ch. 12.4)

Evaluations on CO2 Rich Natural Gas. Jörg Wenzel - Sick

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

ULTRASONIC FLOW METER CALIBRATIONS CONSIDERATIONS AND BENIFITS American School of Gas Measurement Technology, September 2007.

Experiment 8: Minor Losses

Cover Page for Lab Report Group Portion. Head Losses in Pipes

H&D Fitzgerald Pressure Pyknometry System Mark 5

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

Test on a Twin-Screw Compressor

Tube rupture in a natural gas heater

InstrumentationTools.com

Lab 1. Adiabatic and reversible compression of a gas

CUSTODY TRANSFER METERING

THE IMPLEMENTATION OF TOROIDAL THROAT VENTURI NOZZLES TO MAXIMIZE PRECISION IN GAS FLOW TRANSFER STANDARD APPLICATIONS

SITRANS F C. Flow sensor SITRANS FCS400 3/157. At ordering the following fraction or standard density scales can be specified: Overview

ULTRASONIC METER FLOW CALIBRATIONS CONSIDERATIONS AND BENIFITS. Joel Clancy

FAQs about Directive 017

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

pren CEN standard-draft pr EN 12261

NFOGM temadag

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Peria G Mohamed, Abbas Al-Shawwaf, Mahdi Al-Qazweeni & Nasser Bu-Arki Kuwait Oil Company

Ultrasonic Flowmeter USZ 08

Gas Flow Calibration Basics

CALIBRATION PARAMETERS IMPACT ON ACCURACY OF NATURAL GAS ULTRASONIC METER

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Wet Gas Flowmetering Guideline

Lesson 6: Flow Control Valves

Research and Development. Money in the Pipeline

TP Validating a dynamic grid model with tracer gas injection and analysis

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

All-Russia D.I.Mendeleyev Scientific and Research Institute for Metrology (VNIIM)

Transcription:

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility Jos G.M. van der Grinten, NMi EuroLoop Bart van der Stap, Flowways Dick van Driel, Krohne Abstract The operational experiences obtained during the calibration of several types of liquid flow meter clearly demonstrate EuroLoop s ability to test the viscosity dependent performance of these instruments. The temperature as observed during a series of successive runs recorded at a constant flow rate, demonstrates a stability that is a factor 50 better than originally specified. Extension of a previous intercomparison between the EuroLoop and Trapil facilities using an 8 7 path ultrasonic transfer flow meter and EuroLoop s small prover [2] was extended using the big prover. All 19 results match a normalized deviation. For 16 results. Sample analysis performed at two independent laboratories as part of EuroLoop s metrological maintenance, reveals a significant viscosity difference for the lowest and highest viscosity liquids. The density of the samples agrees within their mutual uncertainties, which is important for mass flow measurements. 1. Introduction For most types of liquid flow meters for custody transfer purposes like ultrasonic flow meters, turbine meters and coriolis flow meters, the performance is depending on the Reynolds number dependent velocity profile or on the liquid viscosity directly. Also the factor of Dp devices like orifices, nozzles and Venturis, is depending on the Reynolds number and therefore on the viscosity as well. The EuroLoop Liquid Hydrocarbon Flow Facility operates on three different liquid viscosities 1, 10 and 100 mm²/s (centi-stokes, cst) covering a large range of Reynolds numbers (approximately 1 10 3 4 10 6 ). The rationale behind the construction of EuroLoop is that calibration of a flow meter using different liquid viscosities gives the user of the meter insight on the viscosity dependent performance of the meter. For the manufacturer this knowledge enables him to compensate for the different flow profiles or different viscosities in the meter electronics. In addition EuroLoop can operate at a very constant liquid temperature which will keep the viscosity constant as well. This is extremely important for the calibration of turbine meters, where the calibration needs to be performed with a constant viscosity over the entire range of flow rates. 1

NMi EuroLoop operates the facility and is responsible for the metrological performance. The design of the facility was described earlier [2]. Accreditation is in the process of being acquired [1] and the first round robin tests have been performed [2]. All calibration certificates are issued by NMi EuroLoop. Maintenance is done by Krohne, the designer and constructor of the facility. The actual specifications of the facility are shown in the table below. After years of construction and testing the current paper gives an anthology of operational experiences obtained during calibrations using the EuroLoop Liquid Hydrocarbon Flow Facility and its metrological maintenance. Table 1: Specifications of the EuroLoop Liquid Hydrocarbon Flow Facility Small circuits Large circuits Flow 10 1 200 m 3 /h 30 5 000 m 3 /h Dimensions of meters 4 12 (100 300 mm) 12 30 (300 750 mm) Flanges and pressure classes ANSI 150, PN 10 ANSI 150, PN 10 Kinematic viscosity 1, 10, 100 mm 2 /s (cst) 1, 10, 100 mm 2 /s (cst) Temperature stability Better than 0.1 C Better than 0.1 C Maximum back pressure 12 bar(g) 12 bar(g) Overall uncertainty volume by piston / master 0.02% / 0.06% 0.02% / 0.06% Overall uncertainty mass by piston / master 0.04% / 0.07% 0.04% / 0.07% 2. Description of facility Each circuit, schematically displayed in Fig. 1, is split between a small and a large diameter loop. The temperature increase, resulting from the work exerted on the liquid by the pumps, is reduced by a cooling system using water. A back pressure of 6 9 bar(g) avoids cavitation in the liquid. If necessary, e.g. during the calibration of Venturi tubes, the back pressure can increased to 12 bar(g) to avoid cavitation in the throat of the Venturi. In that case operation has to be performed with great caution as safety valves open at 12.5 bar. The primary references for calibration consist of a large piston prover and a small piston prover, which are both operated on all three liquids. The secondary references are master meters, which is a combination of an upstream monitoring full bore and downstream reduced bore ultrasonic meter. The temperature in each circuit is monitored by fast ultrasonic sensors that measure the average temperature in a cross section of the pipe without disrupting the flow pattern. The ultrasonic temperature sensor is combined with an upstream pressure transmitter and a downstream Pt100. If the liquid properties change the readings of the ultrasonic temperature measurement and the Pt100 will start to deviate. In this way the operator is triggered to have the liquids analyzed again. In addition the operator has a diagnostic tool for checking the liquid homogeneity. 2

Fig. 1:. Schematic drawing of the EuroLoop Liquid Hydrocarbon Flow Facility. One circuit is shown, the others are identical. The piston provers are shared by all three circuits. Each calibration starts with the specification of the calibration set-up. For the small circuits 24 meter straight length is available, for the large circuits 28 meter is available. In each configuration sufficient length is planned behind flow disturbances, like reducers or expanders. Before the start of the calibration all air and vapours are eliminated from the circuits and leak tests are performed. The liquid is homogenized, which is tested by the ultrasonic temperature measurements in the circuits. The last step in the preparation is an integrity check of the system. For each calibration there is a choice to use only the master meters as reference, or to use both master meters and piston prover. The latter option guaranties a substantially lower uncertainty, but requires more time. The calibration itself starts with temperature equalization by circulating the liquid at a flowrate above 0.5. The calibration flow rates and repeats can be performed according to API MPMS, OIML R117 or client wishes. 3

3. Traceability The traceability of the EuroLoop Liquid Hydrocarbon Flow Facility is schematically shown in Fig. 2. The piston provers are directly traceable to length, the master meters are traceable to the piston provers and the meter under test is traceable to either the master meters or the piston provers. A more elaborate description on the traceability of EuroLoop was discussed in an earlier paper [2]. m Piston Prover Master Meter Meter under Test Fig. 2: Traceability chain of the EuroLoop Liquid Hydrocarbon Flow Facility. 4. Metrological maintenance Part of the metrological maintenance is the regular determination of the density and the kinematic viscosity of all three liquids. The density and kinematic viscosity are obtained from analyzing samples from the test fluids. For this purpose we use two labs. A test laboratory is located close to EuroLoop and performs routine tests according to the appropriate ASTM standards [3][4]. Test results are available with 24 hours. The lab has an ISO 9001 certificate but does not hold an ISO 17025 accreditation. The calibration laboratory holds and ISO 17025 accreditation for viscosity, however the accredited density is outside the range we need at EuroLoop. This lab is further away and delivery times are between one and three weeks. Both laboratories obtain their traceability from reference liquids that are externally purchased from an ISO 17025 accredited laboratory. EuroLoop needs results fast and also needs an ISO 17025 accredited lab. For that reason a small proficiency test (PT) was organized between both labs to verify if they produce equivalent results.. The liquids were circulated in the test sections in order to homogenize them. Then samples were taken and for each liquid two bottles were filled directly after each other. The samples were labelled and send to the labs. Lab A analyzed the sample at 10, 20 and 30 C. Due to time constraints Lab B could perform the analysis at 20 and 30 C only. Results were returned by calibration certificates and are graphically displayed in Fig. 3. The upper graphs show the results of the analysis. In order to distinguish the results of both labs the results of Lab A were plotted at the nominal temperature minus 0.5 C and for Lab B at the nominal temperature plus 0.5 C. The date of the analysis is shown in the legend of the graph. On the scale used, all results look identical. 4

En [-] En [-] ν [mm²/s] ρ [kg/m³] 33 rd International North Sea Flow Measurement Workshop In order to compare results between laboratories the so-called normalized deviation used, which is defined as: is (1) This is the ratio of the difference between two results and the uncertainty of the difference. If the difference of two measurement results is smaller than the uncertainty of the difference, i.e., results are in agreement. When the uncertainties have a coverage factor of, the confidence level of this assessment is at least 95.4%. 1000 100 10 1 5 15 25 35 t [ C] Viscosity 1 mm²/s Lab A 1 mm²/s Lab B 10 mm²/s Lab A 10 mm²/s Lab B 100 mm²/s Lab A 100 mm²/s Lab B 880 860 840 820 800 780 760 740 720 Density 5 15 25 35 t [ C] 1 mm²/s Lab A 1 mm²/s Lab B 10 mm²/s Lab A 10 mm²/s Lab B 100 mm²/s Lab A 100 mm²/s Lab B En of Viscosity En of Density 12.00 10.00 8.00 6.00 4.00 2.00 0.00 5 15 25 35 t [ C] 1 mm²/s 10 mm²/s 100 mm²/s 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 5 15 25 35 t [ C] 1 mm²/s 10 mm²/s 100 mm²/s Fig. 3: Proficiency test results for kinematic viscosity [mm²/s] (left hand side) and density (right hand side) of EuroLoop s three hydrocarbon liquids. The upper graphs show the results of the analysis, where the viscosities are plotted on a logarithmic scale. The lower graphs depict the normalized differences. In the lower part of Fig. 3 the values are plotted. For the density all values are less than 1, which means the labs agree. For the viscosities the results for the 10 mm²/s liquid agree very well. The results for the other liquids differ significantly. The laboratories were asked for clarification but have not responded so far. 5

The agreement of the density results is important for the comparison of a mass flow meter with a volume reference. For the uncertainty of the density the root-sum-square value of both labs are taken, i.e. 0.025%. In the viscosity comparisons the 10 cst results are extremely well in agreement and for this reason the differences observed for the other liquids are remarkable. For the 1 cst liquid, which means a difference in the measured viscosities of 7%, too much for comparing facilities that operate on different liquid viscosities. The viscosity values obtained at the accredited lab will be used for reference. EuroLoop will use a 1% uncertainty for all liquid viscosities and corresponding Reynolds numbers. Further steps will be taken which will include a critical evaluation of our own sampling procedures, a repetition of the comparison to see if differences are consistent over time, looking for laboratories that have a relevant ISO 17025 accreditation and supplier audits that will focus on the details of the measurement processes for density and viscosity. 5. Calibration experiences Now the facility is operational we are acquiring experience with the different types of flow meters. The examples shown comprise two turbine meters in series, two different coriolis meters and an ultrasonic meter. All results are anonimized unless the owner has given us explicit consent to mention details of the meters. 5.1 Turbine meters The two 16 turbine meters were calibrated in series. Both meters were configured with a pipe bundle 20D upstream of the meter. The schematic setup is displayed in Fig. 4. The meters are red, the inlet pipe with the flow conditioners is yellow and the flow conditioners are white. Below the spools the length of each section is indicated. Above the spool the pipe number are written. A B Fig. 4: Schematic configuration of the calibration setup of two 16 turbine meters. 6

Deviation [%] Deviation [%] 33 rd International North Sea Flow Measurement Workshop The meters were calibrated with the 10 cst liquid, however due to elevated temperature of 25.9 C the effective kinematic viscosity was 7.88 mm²/s. The as-found results of the calibrations are shown in Fig. 5. The deviation of both meters is in the range of -0.15% and 0.00%. Both meters show a relatively flat curve in the lower operating range. Between 60% and 100% of one meter raises while the other curve drops. The meters have been sent back to the manufacturer for furter examination. One of the observations made during the calibrations is that the temperature variation during a series of succesive repeats at one specific flow rate is very low. The double standard deviation equals =0.002 C, which corresponds to a viscosity stability of better than 4 10-4 mm²/s. Both values are less than the calibration uncertainty of the quantities. The temperature stability appears to be a factor 50 better than the design specification in Table 1, which is beyond expectation. Despite this impressive result the uncertainty analysis will be based on a temperature repeatability (2s) of 0.05 C. 0.1 0.1 MuT A, 10 mm²/s MuT A, 10 mm²/s 0.0 MuT B, 10 mm²/s 0.0 MuT B, 10 mm²/s -0.1-0.1-0.2 0 1000 2000 3000 4000 Volume Flow Rate [m³/h] -0.2 10 000 100 000 1 000 000 Reynolds number [-] Fig. 5: As-found calibration results of two turbine meters A (in blue) and B (in red). The deviation is plotted as a function of the flow rate [m³/h] (left) and the Reynolds number [-] (right). 5.2 Coriolis meters An example of the calibration of a coriolis meter is shown in Fig. 6. The coriolis meter was calibrated using the piston prover as a reference. On the left hand side the deviation is plotted versus the mass flow rate, on the right hand side the deviation is plotted versus the Reynolds number. The error bars in both graphs indicate the expanded overall uncertainty ( ). All results range between -1.5% and +0.5%. In the left graph of Fig. 6 the viscosity dependency of the meter is clearly visible. The difference between the deviations at a specific flow rate exceeds the uncertainties and is therefore significant. The higher the viscosity the more the curve drops to minus at low flow rates. The right hand graph of Fig. 6 shows that the curves on the different product connect well in the overlapping Reynolds range. This knowledge allows the manufacturer to compensate for the Reynolds dependency. 7

Devaition [%] Deviation [%] Deviation [%] Deviation [%] 33 rd International North Sea Flow Measurement Workshop For a different coriolis meter Fig. 7 shows an example what will happen if such compensation is in place. Here calibration results are plotted using a liquid with a nominal viscosity of 100 mm²/s. The results are cumulated from runs performed on two dates. Where in Fig. 6 the results of a regular coriolis meter for the highest viscosity liquid range from -1.5% to 0.0%, the deviations for the viscosity compensated meter are between -0.2% to 0.05%. This is a reduction in the dispersion of the observed deviations with a factor six. Before putting out the flag, some remarks are to be made here. During the measurements the coriolis meter showed substantial variations of the viscosity indication while the actual viscosity was constant. Unfortunately, there was no opportunity to test the meter with other liquid viscosities. It would be interesting to test the meter with both lower and higher viscosities. And lastly the question is whether the viscosity compensation mechanism is influenced by other parameters or conditions. 1.0 1.0 0.5 0.5 0.0 0.0-0.5-0.5-1.0-1.5 (1.161 ± 0.002) mm²/s (11.13 ± 0.37) mm²/s (91.6 ± 4.5) mm²/s -1.0-1.5 (1.161 ± 0.002) mm²/s (11.13 ± 0.37) mm²/s (91.6 ± 4.5) mm²/s -2.0 0 200 400 600 800 1 000 Mass flow rate [kg/h] -2.0 1 000 10 000 100 000 1 000 000 10 000 000 Reynolds number [-] Fig. 6: Results of the calibration of a coriolis meter with three different viscosity liquids. The deviation [%] is plotted versus the mass flow rate [kg/h] (left graph) and versus the Reynolds number [-]. Error bars represent the overall expanded uncertainty. 0.15 0.1 0.05 0.15 0.1 0.05 0 0-0.05-0.05-0.1-0.15-0.2-0.25 0 500 1000 1500 2000 2500 3000 Mass flow rate [kg/h] 100 mm²/s, 29 Apr 2015 100 mm²/s, 24 Apr 2015-0.15 100 mm²/s, 29 Apr 2015-0.2 100 mm²/s, 24 Apr 2015-0.25 1000 10000 100000 Reynolds number [-] Fig. 7: Calibration results of a coriolis meter with viscosity compensation using a liquid with a nominal viscosity of 100 mm²/s. The deviation [%] is plotted versus the mass flow rate [kg/h] (left graph) and versus the Reynolds number [-]. Error bars represent the overall expanded uncertainty. -0.1 8

Deviation [%] Normalized deviation En [-] 33 rd International North Sea Flow Measurement Workshop 5.3 Ultrasonic meters For ultrasonic meters Reynolds-based profile corrections are already common practise. This makes the meter suitable for intercomparison exercises. In a previous paper [2] an intercomparison was described between the Trapil and EuroLoop facilities, in which only EurpLoop s small piston prover was used. At EuroLoop the calibrations were repeated with the big piston prover using a single meter (i.e. 8 Altosonic 5 NG meter s/n A14050085 19YA20901_2002) that was used in the previous experiment. The calibration results were compared with the previously obtained results at Trapil [2]. The left picture in Fig. 8 gives an overview of all calibration results obtained both at Trapil and at EuroLoop utilizing the big piston prover. All calibration results are found in a bandwidth of 0.2%, which is the result of the implementation of a profile correction algorithm. Error bars indicate the overall expanded uncertainties, black for Trapil s results and blue for EuroLoop s results. Uncertainties range between 0.03% and 0.11%, which is caused by differences in repeatability. The agreement between Trapil and EuroLoop was evaluated using defined in Eq. 1. The Trapil results were obtained at Reynolds numbers that differ from the Reynolds numbers of the EuroLoop results. In order to compare the results a linear interpolation was used to translate the observed deviations at Trapil and their uncertainties to the Reynolds numbers of the EuroLoop observations. In formula: in which is the Reynolds number of the observation at EuroLoop, and are the adjacent Reynolds numbers corresponding to the deviations and in Trapil, and are the expanded uncertainties corresponding to and. (2) 0.15 0.10 0.05 0.00-0.05-0.10 Gasoline 0.80 mm²/s -0.15 Heating oil 5.6 mm²/s Heavy crude 64 mm²/s -0.20 Euroloop 1 mm²/s LP Euroloop 10 mm²/s LP -0.25 Euroloop 100 mm²/s LP 1000 10000 100000 1000000 10000000 Reynolds number [-] 0.0 1000 10000 100000 1000000 10000000 Reynolds Number [-] Fig. 8: Meter curves obtained at EuroLoop and Trapil for meter A (left). The deviation of the meter [%] is plotted versus the Reynolds number [-]. Error bars indicate the total uncertainty (k=2) of the measurement results. The grey and the blue bars are attached to Trapil and EuroLoop results respectively. On the right the normalized deviation [-] is plotted versus the Reynolds number [-]. 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 En 1 mm²/s En 10 mm²/s En 100 mm²/s 9

The results are depicted in the right graph of Fig. 8. All 19 values are less than 1, 16 values are less than 0.5. These results mean that all Trapil and EuroLoop results agree with at least 95.4% confidence. 6. Conclusions Now EuroLoop is fully operational the characteristics of the facilities can be compared with the specifications the facility was designed to. From the operational experiences described in the previous chapters to following conclusions can be drawn. 1. EuroLoop is very suitable to test the viscosity dependence of flow meters. Instruments with viscosity compensation installed can be calibrated and verified at EuroLoop leading to improved meter performance at lab conditions. 2. The temperature stability observed during a series of successive calibration runs at one specific flow rate appears to be much more constant than originally expected. Instead of 0.1 C double standard deviations of 0.002 C were observed. Despite this impressive result a temperature repeatability (2s) of 0.05 C will be used in the uncertainty analysis. 3. After earlier intercomparisons using the small piston prover [2], even better comparison results were obtained between Trapil and EuroLoop using the big piston prover. All observations have a normalized difference smaller than 1, which means that the results agree with more than 95.4% confidence. From the 19 observations, 16 had a normalized difference of smaller than 0.5. 4. Point of attention for the metrological maintenance is the analysis of liquid samples. Although traceability is in order, there is a significant difference between the two test and calibration laboratories for the lowest and highest viscosity liquids. The density of the samples agrees within their mutual uncertainties. Further steps will be necessary to resolve the differences. 7. References [1] Jos van der Grinten, Bart van der Stap and André Boer (2015): Preparing the new EuroLoop liquid flow facility for accreditation, Lecture presented at the 3rd European Flow Measurement Workshop, 17-19 March 2015, Noordwijk, The Netherlands [2] Jos van der Grinten, Bart van der Stap and Pico Brand (2015): Round robin testing for the new EuroLoop liquid flow facility, International Symposium for Fluid Flow Measurement, 14-17 April 2015, Arlington, Virginia, USA [3] ASTM D 7042-14 (2014): Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity), ASTM International, PA, USA [4] ASTM D 4052-11 (2011): Standard Test Method for Density, Relative Density, and API Gravity of Liquids by Digital Density Meter, ASTM International, PA, USA 10