PROPERTIES OF R-134A (1,1,1,2-TETRAFLUOROETHANE)

Application Worksheet

Troubleshooting Guide. Pg. 1

Using P-T Analysis As A Service Tool

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

The Hoffman Specialty Series 2000 consists of main

OPERATING INSTRUCTIONS

Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries

Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant

Technical Committee on LP-Gas at Utility Gas Plants

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Single & Headered Relief Vent Piping Analysis

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

Venting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014

Analytic and Experimental Techniques for Evaluating Compressor Performance Losses

System Conditions Harmful to Compressors Their Diagnosis and Prevention

Product Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES

Single- or Two-Stage Compression

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

Control Valve Sizing. Sizing & Selection 3 P 1. P 2 (Outlet Pressure) P V P VC. CONTENTS Introduction Nomenclature Calculating C v

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Seminar 65 Compression Challenges for Low GWP Refrigerants

Brazed Heat Exchangers

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.


KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

The capacity of the cargo tank venting system (46 CFR );

Capacities Valve Station, type ICF 15, 20, 25

Brazed Heat Exchangers - Edition 2. Click Anywhere to enter

Low GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Two-Stage Linear Compressor with Economizer Cycle Where Piston(s) Stroke(s) are Varied to Optimize Energy Efficiency

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Unit C-2: List of Subjects

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

Tproperties of refrigerants, arranged for the occasional user. The

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

FMU4X, FMC4X FMU4P, FMC4P

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

CO 2 refrigeration in warm climates. Copyright 2012 shecco All rights reserved.

VBS-9263 Series. Application. Features. Applicable Literature

Plunger Fall Velocity Model

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

SIZING AND CAPACITIES OF GAS PIPING

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Natural Gas Gathering

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

VB-7263 Series. Application. Features. Applicable Literature

Product Data. CK5A, CK5B, CK5P Furnace N-Coils. Sizes A018 thru A060

SELECTION CRITERIA FOR SAFETY VALVE

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Distillation Design The McCabe-Thiele Method

Cavitation in Valves

A virtual EXV mass flow sensor for applications with two-phase flow inlet conditions

VB-7273 Series. Application. Features. Applicable Literature

Updated Performance and Operating Characteristics of a Novel Rotating Spool Compressor

Expansion Tank Design (Chilled Water)

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

SIZING AND CAPACITIES OF GAS PIPING

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

Gerald D. Anderson. Education Technical Specialist

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Heat Pump Connections and Interior Piping

2 are both ways of saying a ratio of 2 to 5

Gas Turbine Performance Analysis

SHOP WELDED TANKS STANDARD CONNECTIONS

Plunger Fall Velocity Model

ENGR 292 Fluids and Thermodynamics

Product Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP

Pump-Fan-Compressor Sizing

CORRECTING FOR HUMIDITY EFFECTS ON TSI GENERAL PURPOSE FLOWMETERS

Regulating valves REG-SA and REG-SB

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

North American Orifice Metering System

EN00 Pre-Instructional Survey

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Chapter 2: Pure Substances a) Phase Change, Property Tables and Diagrams

Calculation of Gas Density and Viscosity

CASED HORIZONTAL FURNACE COIL. Model CK3B. Form No. SS-CK3B-01 FEATURES

Gas Lift Valve Testing

CHAPTER 3 : AIR COMPRESSOR

iphone Application Slurry Pump System Calculator Instructions

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

Designing a Pond Loop using. Alan Watts, CGD, IAI AWEB Supply Baton Rouge, LA

Unit A-2: List of Subjects

Lecture Outline Chapter 15. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Transcription:

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES THIS REPORT WAS PREPARED BY THE ORGANIZATION(S) NAMED BELOW. NEITHRE THE ORGANIZATION(S) BELOW, NOR ANY PERSON ACTING ON BEHALF OF THEM: (A) MAKES ANY WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS, OR IMPLIED, (I) WITH RESPECT TO THE USE OF ANY INFORMATION, APPARATUS, METHOD, PROCESS OR SIMILAR ITEM DISCLOSED IN THIS REPORT, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR (II) THAT SUCH USE DOES NOT INFRINGE ON OR INTERFERE WITH PRIVATELY OWNED RIGHTS, INCLUDING ANY PARTY'S INTELLECTUAL PROPERTY, OR (III) THAT THIS REPORT IS SUITABLE TO ANY PARTICULAR USER'S CIRCUMSTANCE; OR (B) ASSUMES RESPONSIBILITY FOR ANY DAMAGES OR OTHER LIABILITY WHATSOEVER (INCLUDING ANY CONSEQUENTIAL DAMAGES, EVEN IF DENKMANN THERMAL STORAGE, LTD. OR ANY DTS LTD. REPRESENTATIVE HAS BEEN ADVISED OF THE POSSBILITY OF SUCH DAMAGES) RESULTING FROM YOUR SELECTION OR USE OF THIS TECHNOTE OR ANY INFORMATION, APPARATUS, METHOD, PROCESS, OR SIMILAR ITEM DISCLOSED IN THIS TECHNOTE. ORGANIZATION(S) THAT PREPARED THIS TECHNOTE DENKMANN THERMAL STORAGE, LTD. You may, as holder of this copyrighted technote, make one hardcopy for your own use. If this hardcopy becomes lost or dog-eared, you may make another single hardcopy from the E copy on your hard drive. Please do not give copies to others instead have them visit this website and download their own copy. Oh, the above disclaimer? The lawyers make me do it! Jim Denkmann / The Windy City / U.S.A. 2007 J. Denkmann, Selecting EPR Port Diameters 1

Selecting EPR Port Diameters This paper presents an example for prdicting the full-open (100% wide open) port diameter required for a pressure regulator. Thes method identifies mass flow and specific vapor volume, then calculates a theoretical Cv for the regulator which is used when selecting regulator ports from a manufacturer s catalog. It is usually desirable that the port diameter of a regulator < the connected pipe size. 1.1 Summary of Equations (1) btu TR 200 TR m min = h leave h enter mass flow to evaporator, pounds per minute (lb/min) (2) 0.947m Cv = finding Cv when mass flow, p across port, specific volume are known p ρ Nomenclature h enter h leave m P p enthalpy of refrigerant entering evaporator, btu/lb enthalpy of refrigerant leaving evaporator, btu/lb mass flow, pounds per minute pressure, pounds per square inch, gauge (psig) pressure, pounds per square inch, absolute (psia) t temperature, ºF TR V p net refrigerating effect, tons (1 TR=200 btu/min) specific volume, cubic feet per pound (also 1/ρ), ( ft 3 /lb) differential pressure, pounds per square inch (psi) ρ weight density of fluid, pounds per cubic foot (lb/ft 3 ) 2007 J. Denkmann, Selecting EPR Port Diameters 2

1.2 Selecting Minimum Regulator Port Diameter (Cv) Problem: Select the EPR port diameter for the evaporator shown in Figure 1 below. Given: a 15 TR evaporator to be installed on a dock maintained at 45 ºF. Liquid will be supplied to this evaporator with HPL at a mean condensing pressure of 155 psig (subcooled to 30 ºF) into a thermal expansion valve. The regulator will be set to maintain an evaporating temperature of 25 ºF; the TXV will superheat the leaving vapor by 10 ºF. Figure 1 graphically depicts the process and plots the respective state points for predicting the following: Step 1 - find evaporator mass flow and vapor specific volume Step 2 - find the minimum port Cv required when the EPR is wide open Step 3 - select a regulator port diameter from above find port o p=45.0 p=169.29 t_ref=30 F p=53.72 t_ref=35 F 15 TR p_evap=53.72 t_sat=25 F p=169.29 t_ref=30 F subcooling h=64.6 btu/lb p=53.72 t_sat=25 F flash gas x=0.0075 h=138.8 t_sat=86 F 70.07 74.18 618.98 625.2 t_ref=35 F superheating h=6.2 btu/lb Figure 1 While five values of enthalpy are given in Figure 1, only two of these are needed to solve for mass flow to this evaporator. The other values are shown to emphasize the impact of liquid subcooling and vapor superheat upon mass flow in the following equation: btu TR 200 TR m min = h leave h enter (1) 2007 J. Denkmann, Selecting EPR Port Diameters 3

Step 1 Find m,v We first solve Eq 1 for the refrigerant state points used to select both the evaporator and it s companion EPR port diameter. Vapor leaving the evaporator has these state points (and properties): h=625.2, p=73.72, t sat =25 ºF, t ref =35 ºF. Air passes over the evaporator at an entering temperature of 45 ºF. High pressure liquid enters the TXV at a mean condensing pressure = 170 psia, t sat =86 ºF, is then subcooled in a remote heat exchanger to 30 ºF ( t=56 ºF), then is supplied to the TXV at an enthalpy, h=74.18 btu/lb. The numerator of Eq 1 solves to 3,000 btu/min; the denominator solves to h=625.2 74.18 = 551.02 btu/lb 1. The resulting mass flow under these conditions is 5.44 lb/min. Specific volume of the suction vapor will be found on page 54 of the Little Red Book, for data in the subcooling and superheat regions, 25 ºF, 53.72 psia saturated refrigerant. Look down the left-most column to 35 ºF then read across to the specific volume, 5.4735 ft 3 /lb. Note that for each pound of liquid supplied to this evaporator, very little heat is exchanged in the gaseous superheat region, h=6.22 btu/lb for a 10 ºF rise in sensible temperature. This is a price one pays for superheating ammonia vapor in an evaporator. However, TR is more strongly affected (reduced mass flow) by subcooling HPL by 56 ºF as seen in Eq 1 and Figure 1. If the liquid subcooling process were absent from this analysis, the mass percentage of liquid supplied to this evaporator would have to increase by 13% to 6.17 lb/min for the same 15 TR. No doubt, the HPL line diameter would also have to increase due to the presence of flash gas. It is for this very reason (flash gas inside a HPL line) that subcooling this particular fluid stream has found favor in the industry. Answer: m = 5.44 lb/min Answer: V = 5.4735 ft 3 /lb 1 The leaving enthalpy used in this calculation takes credit for vapor superheat because this superheat occurs inside the evaporator, therefore it becomes useful to the cycle. However, the loss in net refrigerating capacity of a compressor due to suction vapor superheat outweighs the small increase in evaporator capacity due to this same vapor superheat. 2007 J. Denkmann, Selecting EPR Port Diameters 4

Step 2 Find Theoretical Port Diameter This step predicts a theoretical port Cv from Eq 2. In step 3, we use this value to select an available port diameter (Cv) from a manufacturer s catalog. Because of the large increase in vapor specific volume when ammonia vapor is superheated, this increase should be taken into account when solving Eq 2 if accuracy is of importance. After vapor passes through the regulator, the downstream pressure is p=45 psia the intermediate pressure for this facility. Therefore p across the regulator is found from p=p in p out = 8.72 psi. Cv = 0.947m 1 p V (2) Answer: Cv = 4.08 Step 3 Select Regulator Port Diameter from Manufacturer s Catalog Reference 3 reflects a 6.4 Cv for a 3/4" port installed in an HA4A regulator. Note that the TR reflected in the table for suction vapor capacities is based upon saturated 86 ºF liquid, a saturation temperature for the high side regarded as a typical mean (evaporative cooled systems). These capacities do not take 56 ºF liquid subcooling into account, therefore the manufacturer applies a correction factor to their data = 3% increase for each 10 ºF liquid subcooling below the saturation temperature. After applying the subcooling correction factor and interpolating between data shown in reference 3, Suction Vapor Capacities (Tons), the adjusted capacity of a ¾ port becomes 24 TR, p=9 psi, and 25 ºF evaporating temperature. While this port diameter is somewhat larger than required, it will still give adequate performance. If the solution of Eq 2 yields a Cv between two manufacturers Cv data, select the next larger port. The selected suction pipe diameter for 15 TR would either be 1½" sch 80 or 2" sch 40, depending upon allowable pressure drop and length of run. Typically, most contractors would rather purchase a larger regulator body rather than purchase and install two concentric reducers. For further data regarding equations used for predicting pressure drop through valves having a port diameter < connected pipe diameter, see reference 2. Answer: HA4AD, 2" with 3/4" port. end of text 2007 J. Denkmann, Selecting EPR Port Diameters 5

References: 1. ASHRAE, 2005, Handbook of Fundamentals, Chapter 2, American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. 2. Crane, 1976, Technical Paper 410, Flow of Fluids Through Valves, Fittings and Pipe, Crane Company 3. Hansen, 2002, Collection of Instructions, HA4A suction vapor capacities 2007 J. Denkmann, Selecting EPR Port Diameters 6