PRODUCT NUMBER: Rd40 Aluminium Canister HgP3

Similar documents
PRODUCT NUMBER: Rd40 Aluminium Canister K2

Overview. Features & Benefits

Feature Other Straps : Standard black webbing 44 mm PES with PTFE treatment (water repellent / anti stain) Breaking strength :> 2700 dan

Feature Other Straps : Standard black webbing 44 mm PES with PTFE treatment (water repellent / anti stain) Breaking strength : > 2700 dan

PRODUCT NUMBER: A COMPACT AIR A150401

PRODUCT NUMBER: DuraFlex Harness 1-point Rear anchorage, size M/L

Nordic. Feature Other Straps : Standard black webbing 44 mm PES with PTFE treatment (water repellent / anti stain) Breaking strength : > 2700 dan

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

56 LESLIE HOUGH WAY SALFORD GREATER MANCHESTER M6 6AJ UNITED KINGDOM. Tel: +44 (0) Fax: +44 (0)

USER MANUAL EMERGENCY ESCAPE BREATHING APPARATUS FENZY BIO-S-CAPE IN ACCORDANCE WITH EN 1146 STANDARD 0194/ /0060

CARTRIDGE Model: 2030 LD P3 R P/N

PPE: RESPIRATORY PROTECTION EQUIPMENT

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

Breathable Compressed Air

Respiratory Protective Equipment

Respiratory Protection Disposable and Reusable Respirators and their approvals systems

SOUTH AFRICAN NATIONAL STANDARD

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

OPERATION MANUAL MPV-623 AIR-FED VIZOR

3M Personal Safety Division 3M Supplied Air Respirator System S200+ Work. in a World of. Comfort. The Power To Protect Your World

D Lightweight Respiratory Protection

University of Dayton Respiratory Protection Program 29 CFR

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits

Respiratory Protection for Producers

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

National Personal Protective Technology Laboratory

DATASHEET SUPPLIER ART.NO. STAXS. ART.NO. F M Aura respirator with shrouded valve 6 x 8 pcs per box STAXS ART.NR.

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

PERSONAL PROTECTIVE EQUIPMENT

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you. Respiratory Protection

Fire Escape Hood OPERATION AND INSTRUCTIONS

Dräger X-plore Rd40 Filters Filter

OPERATION MANUAL MPV-627 AIR FED HALF MASK

RESPIRATORY PROTECTION

Respiratory Protection Self Inspection Checklist

Particulate Respirator N95

Helping you to correctly select and use respirators. With support from

75 Years of Health and Safety Guidance

Model XSMKIT. Operations and Instructions WARNING

VFlex 9105/9105S Particulate Respirator N95

Operate Breathing Apparatus

Phalanx Alpha Phalanx Beta and Ultra Elite

Respiratory Protection Programs Policy

Respiratory Protection Self-Inspection Checklist

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

8214/8514/07187 Respirator N95 Particulate

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Honeywell North Air-Fed Suits BSL 4 Integrated Respiratory Protection and Protective Clothing

HAZWOPER 8-Hr Refresher Aug. 20, 2012

Respiratory Protection Basics

The Dräger X-plore Series

M 98 RESPIRATOR FOR CIVIL DEFENCE AND LAW ENFORCEMENT

Personal Protective Equipment (PPE) BBK. Working together. Living in safety.

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

SAFETY DATA SHEET (EC REGULATION No 1907/2006 ) Date: 24/04/2008 Page 1/5 Version: N 1 (23/04/2008) Revision: N 1 (23/04/2008) SAFETY DATA SHEET

Safety Relief Valve HON 832

A. Evaluation of the written program

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

A. APPLICATIONS 1. WARNING TO USER

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

North RU8500 Series Half Masks

SR500 PAPR Copyright 2015 by The S.E.A. Group 1

Safety Data Sheet according to Regulation (EC) No 1907/2006

Personal Protective Equipment 29 CFR 1926

2 Hazards identification

Feature Other Straps : Standard black webbing 44 mm PES with PTFE treatment (water repellent / anti stain) Breaking strength :> 2700 dan

Trio Silesse Skin Barrier Wipe Solution

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND COMPANY / UNDERTAKING. USE : White Contrast Paint used as a contrast aid in NDT

Respiratory Protection

RESPIRATORS & FIT TESTING

Hauptüberschrift Optionale zweite Zeile

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

PPE Refresher- Levels of Protection

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

Oxygen Dialflow Meter. Instructions for Use

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

1000 Series. Quality. Superior Filter Media. SABS Quality Mark. Metal Nose Clip. Foldable. Made in South Africa. Comfort Valve. Usage: Application:

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

Dräger X-plore 3500 Half Mask

Safety Data Sheet according to Regulation (EC) No 1907/2006

Oxygen Dialflow Meter. Instructions for Use

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

8200/07023 Particulate Respirator N95

MSA AUER SSR 90 [K60]

Personal Protective Equipment

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

San Mateo County Health System Environmental Health Services Division. Respirator Use

3M Particulate Respirators and 8835+

Safety Data Sheet according to (EC) No 1907/ ISO

STANDARDS FOR COMPRESSED GAS TESTING

Personal Protective Equipment (PPE) Hydrogen Fluoride Hydrofluoric Acid Solutions

Transcription:

Europe / Africa PRODUCT NUMBER: 1784140 Rd40 Aluminium Canister HgP3 The HgP3 canister is part of the broad choice of canisters offered to protect against many hazardous gases, vapors and/or particulates in many applications. The Honeywell range provides high quality and a cost-effective protection. The canisters of RD40 Honeywell range are tested against the European standards EN14387 and EN148 and/or EN143. Overview Reference Number 1784140 Product Type Respiratory Protection Range Reusable APR Brand Honeywell Brand formerly known as FERNEZ by Willson Industry Industry Product Use For use with full-face mask equipped with an Rd40 connector For protection against mercury vapours, solid and liquid particles. s & Benefits Aluminium casing Ø107mm allows easy detection of damages caused by external shocks providing extra safety. Performance requirements for gas and particles significantly above standard for excellent filtration efficiency over extensive period of time. Canister made of high-grade charcoal, additionally treated for an optimal gas absorption. Specific canister structure for low breathing resistance and more comfort for the user. Low profile so as not to obstruct the field of vision Individually packed. Page 1 Of 3

Aluminium SPECIFIC FILTER 450 HG P3-1784140 Presents safety caps on both ends of storage once open up to 6 months. Technical Description Filters Cartridges Standard RD40 connection in compliance with the EN148 - Particle filters efficiency (EN143)- EN14387 (Gas/vapours and combined filters for respiratory with negative pressure) - Conformed to the requirements of the European Community Directive 89/686/EEC (Personnal Protective Equipment), belongs to the EC Category III and is CE marked, followed by the identification of the certification body (0194), which assure the quality control (according to the article 11B). Protection Type Combination Connection Type RD40 Protection Level P3 Class 3 Material special aluminium alloy with PE cover activated and impregnated charcoal without chrome Ø 106mm Certifications E.C. Declaration of Conformity EC Category PPE 3 Quality Assurance ISO 9001 / 2000 EC Certificate Number 757 EC Attestation EC Attestation EC Attestation Number 757 Literature & Documents 1784140 HgP3 tested substances http://www.honeywellsafety.com/supplementary/documents_and_downloads/respiratory_protection /reusable_respirators/4294974286/1033.aspx Additional Information User Manual User Manual Filters Maintenance Life Cycle Depends on absorption capacity, concentration of contaminant and user breathing Storage Information Page 2 Of 3

4 years after date of manufacturing. 6 months after opening. - Store the filters in a cool, dry, location with the caps attached - The maximum permissible storage period is specified on the filter - Storage temperature range: -20 C / +50 C - Maximum humidity during storage: 80% Care Instructions Aluminium SPECIFIC FILTER 450 HG P3-1784140 Controls before use Users must Ensure that the level of protection offered by the respirator is sufficient for the type and concentration of contaminant(s) in the work area Respect the shelf life figuring on the filter Check the seal points Limitations of use For use only by trained and qualified personal Do not use where the oxygen level or the atmosphere is less than 17% Do not use with organic gases and vapours with a boiling point below 65 C After use, an opened canister must be repacked properly with its caps if it is likely to be re-used. It must be replaced no later than within 6 months after opening If a user identifies the break through of the canister by the smell or taste of a gas, the canister must be replaced immediately If the breathing resistance of the canister increased significantly, it must be changed Maximum permitted time of use of the mercury filter (HgP3) is 50 hours (per the EN14387) Particular cautions have to be taken in Atex environments Filter with a mass over 300 g may not be used fitted directly onto half-masks Disposal Canister must be disposed in accordance with the local waste disposal regulations. Packaging EAN Code 3603837841401 Packaging Specs Individual Box 12 x 12 x 11 Packaging Specs Stocker Box 59 x 23 x 23 Unit of Measure CM Quantity per Box/Pack/Case 1 unit of 346 gr Quantity per Carton 50 units for a gross weight 17,30 kg Page 3 Of 3

E.C. Declaration of Conformity The manufacturer or its legal representative supplier in the European Community: Honeywell Safety Products Europe Declares that the Personal Protective Equipment described here after conforms to the provisions of the European Council Directive 89/686/CEE: Designation: Rd40 Aluminium Canister HgP3 Reference: 1784140 Standard(s): EN141 This PPE is the object of the below EC examination certificate n : 757 Delivered by: INSPEC 56 Leslie Hough Way Salford M6 6AJ Greater Manchester United Kingdom +44 (0)12 96 68 29 66 Drawn up in Villers-Cotterêts, on the 02/05/2016 By: Eric PUILLE Division: Respiratory Protection Zl Paris Nord II 33, rue des Vanesses BP 50288 95958 Roissy CDG France Tel: +33 (0) 49 90 79 79 Fax: +33 (0)1 49 90 79 80 www.honeywellsafety.com

Part # Number 1784140 Rd40 Aluminium Canister HgP3 Gases Tested Conditions and results - Mercury vapours Hg - The toxic concentration by volume of the test gas is 13 mg/m3 Aerosols tested - The tested air flow is 30 litres per minute - Minimum length required before "breakdown": Hg 100 hours. Conditions and results * Liquid paraffin for liquid particulates - The tested air flow is 95 litres per minute * Sodium chloride for solid particulates - The aerosol penetration for the test must be less than: *0.05% for sodium chloride *0.05% for parrafin oil - Breathing resistance less than: * 2.6 mbar at 30l/min. * 9.8 mbar at 95l/min