Types 749B and R130 Changeover Manifolds

Similar documents
R600 and HSRL Series Instruction Manual

R122H, R222, R232A, and R232E Series Instruction Manual

R600 and HSRL Series Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

1805 Series Relief Valves

Types S100K and S102K Pressure Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

64 Series Pressure Reducing Regulators

1305 Series Pressure Reducing Regulators

MEGR-1912 Instruction Manual

MEGR-1627 Instruction Manual

1301 Series High-Pressure Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type R622 Pressure Reducing Regulator

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

1805 Series Relief Valves

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

First Stage Regulators

Inspecting LP-Gas Regulators

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

1200B2 Series Service Regulators. Instruction Manual

Types S100C and S102C Pressure

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

T208VR Series Tank Blanketing Vacuum Regulator

Pressure Regulators. Operating Instructions. Instrumentation

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Operator: Save these instructions for future use!

36H SERIES Combination Gas Valve

G96 Series BASOTROL Dual Operator Valve

1800C and 1800C-HC Series Service Regulators

Type ACE95jr Tank Blanketing Valve

Types 95L and 95H Pressure Regulators

GM Series Dual-Block Multi-Function Gas Control Valves

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

2.0 INSTALLATION & SERVICE

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

Type CT88 Backpressure Regulator

Tri-Tech Medical Inc.

BGA158 Series CE Approved Class A Shutoff Gas Valve

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

GM-7000 Series CE Approved Gas Control Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

CS800 Series Commercial / Industrial Pressure Reducing Regulators

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

SERIES SAFETY VALVE

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

630 Series Regulators and Relief Valves

S300 Series. Valve Link. Features. Fisher Controls

627 Series Pressure Reducing Regulators

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Type FEQ Slam-Shut Valve

Installation & Maintenance Manual. Economy Manifold

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

Dual Solenoid Gas Valve Installation

Your safety and the safety of others are very important.

Model 141-A Regulators

29 SERIES - SAFETY VALVE

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGC258 Series BASOTROL Gas Valve

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Regulator from 1800 B series

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

CS200 Series Commercial / Industrial Pressure Reducing Regulators

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

623 Series Dome Load Regulators

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Installation, Operation and Maintenance Manual for Back Pressure Regulator

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

PRO-50 Instrument Supply Regulator

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Propane Conversion Kit Instruction

Excela-Flo REGULATORS

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

Float Operated Level Controllers

Transcription:

Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher equipment must be installed, operated, and maintained in accordance with federal, state, and local codes and Emerson Process Management Regulator Technologies, Inc. instructions. The installation in most states must also comply with NFPA No. 54 and 58 standards. Only personnel trained in the proper procedures, codes, standards, and regulations of the LP-Gas industry should install and service this equipment. Things to tell the Gas Customer: 1. Point out the regulator s vent to the customer (or vent assembly or vent tube), and stress that this opening must remain unobstructed at all times. Tell the customer to be sure to check the vent opening after a freezing rain, sleet storm, or snow to make sure ice has not formed in the vent. 2. Show the customer the shutoff valve on the container. The customer should close this valve immediately if gas is smelled, appliance pilot lights fail to stay on or appear higher than usual, or any other abnormal situation occurs. 3. Tell the customer to call your company to service the regulator if the regulator vents gas or a leak develops in the system. Only a qualified gas service person should install or service the regulator. D450078T012 www.fisherregulators.com

Specifications The Specifications table lists the specifications for the regulators. Contact the factory if the regulators are to be used on any sevice other than LP-Gas, natural gas, or air. Changeover Manifold Assemblies CAPACITY BTU/HR. PROPANE TYPE INLET CONNECTIONS OUTLET CONNCETIONS OUTLET PRESSURE SETTING Supply Setting Reserve Setting 1,475,000 (1) R130/21 1/4-inch FNPT 1/4-inch FNPT 45 psig 3.1 bar 30 psig 2.1 bar 1,500,000 (1) 749B/21 1/2-inch FNPT 1/2-inch FNPT 15 psig 1.0 bar 5 psig 0.35 bar 1. Based on 100 psig / 6.9 bar inlet, reserve setting. Commercial Automatic Changeover Regulators CAPACITY BTU/HR. PROPANE TYPE INLET CONNECTION OUTLET CONNCETION OUTLET PRESSURE SETTING OUTLET ADJUSTMENT RANGE MOUNTING BRACKET 1,575,000 HSRL-749B 1/2-inch FNPT 3/4-inch FNPT 11-inches w.c. 27 mbar 9 to 13-inches w.c. 22 to 32 mbar P100A 1,210,000 64SR/122 1/2-inch FNPT 1/2-inch FNPT 10 psig 0.69 bar 5 to 20 psig 0.35 to 1.4 bar - - - Maximum Inlet Pressure 250 psig / 17.2 bar Temperature Range -20 to 160 F / -29 to 71 C Introduction Scope of the Manual The Instruction Manual covers installation and maintenance for the Types 749B, R130 changeover manifolds and the Types 64SR/122 and HSRL-749B commercial automatic changeover regulators. Description Changeover Manifold Assemblies Type R130/21 Composed of two Type 67C regulators and a special 0 to 60 psig / 0 to 4.1 bar pressure gauge, the Type R130/21 delivers a 45 psig / 3.1 bar outlet pressure on supply and 30 psig / 2.1 bar on reserve. The gauge, which serves as the changeover indicator, is painted red from 0 to 35 psig / 0 to 2.4 bar. When the dial reads in the 0 to 35 psig / 0 to 2.4 bar range, it indicates that the manifold has switched from the supply to the reserve cylinder. Type 749B/21 Large capacity changeover manifold for commercial and industrial applications. It consists of two Type 64 regulators and a Type 803 direct indicator. The assembly is used primarily in conjunction with either a Type HSRL or 64SR regulator. The standard outlet setting is 15 psig / 1.0 bar (supply) and 5 psig / 0.34 bar (reserve). CAUTION Capacity of all these changeover manifolds is dependent on the size of the second stage regulator with which they are used. If the manifolds are used on final-stage (pounds-to-pounds), a relief valve is required in the downstream system. Commercial Automatic Changeover Regulators Designed for large capacity multi-cylinder or tank installations, these regulators are used on such applications as bakeries, motels, restaurants, and grain dryers. The manifold portion of the assembly (Type 749B/21) consists of two Type 64 regulators and a direct mounted Type 803 indicator. Type HSRL-749B For low-pressure service. The Type HSRL second-stage portion has the drip lip vent feature and built-in travel stop to open the internal relief valve. Type 64SR/122 For high-pressure (pounds to pounds) service with the second-stage composed of Type 64SR that has internal relief. 2

MADE IN USA s MADE IN USA Types 749B and R130 1 ST STATE CHANGEOVER MANIFOLD SECTION PRESSURE GAUGE OR INDICATOR WITH RED WARNING FLAG FISHER CONTROLS FISHER CONTROLS SUPPLY INLET SUPPLY RESERVE INLET VENT VENT POINT ALL VENTS DOWN FISHER CONTROLS MADE IN USA FINAL STAGE REGULATOR VENT T40469 FINAL STAGE REGULATOR Figure 2. Changeover Regulator Operation The Changeover Manifold (Figure 2) consists of two regulators (supply and reserve) and an indicator that denotes when the reserve regulator is in operation. The Supply regulator has the handwheel labelled SUPPLY. Open both container valves slowly. Gas will now flow from both containers through the piping into the first-stage section of the regulator manifold by way of the inlet fittings. When the reserve pressure setting (see Specifications) is reached in the first-stage regulator manifold, the disk assembly in the reserve regulator will shutoff gas from the Reserve container. Gas from the Supply container will continue to enter the supply regulator until the supply pressure setting (see Specifications) is maintained. Any second or final stage regulator reduces this pressure for use by the appliance. The Supply side of the regulator manifold will continue to supply gas as long as sufficient gas remains in the Supply container. When pressure in the Supply side container drops to the reserve setting, the Reserve side of the regulator manifold will open and maintain the reserve setting to the second-stage regulator, which continues to regulate the pressure to the appliance. At the time the pressure in the Supply container drops to the reserve side pressure, a red warning flag appears in the indicator window or the pressure gauge pointer drops into the red section (Type R130) and also on the remote indicator if one is used. Switching Supply Containers The open line (pigtail or hose) must be capped because gas will escape to the atmosphere through the open connection if pressure in the supply cylinder drops to the reserve pressure setting (red indicator flag visible). Refer to Figure 3. Once the Supply container is empty, remove the Reserve cap (key 4) which is attached to the chain assembly (key 8) and the Supply handwheel (key 3) by turning them counter-clockwise. Do not remove the adjusting screw (key 5) or the nut (key 1) on the adjusting screw. Screw the Supply 3

handwheel into the old reserve side regulator until it cannot be turned any further. This side is now the new Supply side. Screw the cap and the chain assembly into the old supply side until it cannot be turned any further. This side is now the new Reserve side. When the Supply handwheel is installed in the new side, the red flag in the indicator should disappear or the pointer in the gauge should move out of the red. CAUTION There will still be pressure in the empty container equal to the Reserve side manifold setting. If the containers are cylinders, close the cylinder valve of the empty cylinder to prevent air from entering the cylinder and disconnect the cylinder. Clean the new cylinder s valve outlet. After the new cylinder is in place, slowly open the cylinder valve. The new cylinder now becomes the reserve cylinder. If only one cylinder, the new supply cylinder, is left connected, the open line (pigtail or hose) must be capped to prevent leakage or contamination. Installation Personal injury or system damage may result if these regulators are installed without appropriate overpressure protection. Maximum emergency outlet pressure for the Type 67C regulators used on the Type R130 is 50 psig / 3.4 bar over the outlet pressure setting, or 100 psig / 6.9 bar, whichever is greater. Maximum emergency outlet pressure for the 64 regulators used on the Type 749B is 220 psig / 15.2 bar. Maximum emergency outlet pressure for the Type HSRL final stage regulator is 3 psig / 0.21 bar above setpoint. Outlet pressures greater than these above set point may cause damage to regulator parts, leaks in the regulator, or personal injury due to bursting of pressure-containing parts or explosion of accumulated gas. If the regulator is exposed to an overpressure condition, it must be inspected for any damage that may have occurred. Large volumes of gas may discharge through the regulator vent during internal relief valve operation which can result in fire or explosion from accumulated gas. All vents should be kept open to permit the free flow of air into and out of the regulator. Protect openings against the entrance of rain, snow, ice formation, paint, mud, insects, or any other foreign material that could plug the vent. LP-Gas may discharge to the atmosphere through the vent. An obstructed vent which limits air or gas flow can cause abnormally high pressure that could result in personal or property damage. Make sure gas flow through the regulator is in the correct direction. There are two 1/4-inch NPT (Type R130) or two 1/2-inch NPT (Type 749B) inlet connections and the Outlet connection is clearly marked on the regulator. The installation should be adequately protected from vehicular traffic and damage from other external sources. Install the regulator high enough above ground level - at least 18 inches / 457 mm - so that rain splatter cannot freeze in the vents. Whether a protective hood is used or not, do not install the regulator in a location where there can be excessive water accumulation or ice formation, such as directly beneath a downspout, gutter, or roof line of a building. A regulator installed outdoors without a protective hood must have its vent pointed vertically down, see Figure 2, to allow condensate to drain. This minimizes the possibility of freezing and of water or other foreign material entering the vent and interfering with proper operation. Some installations, such as in areas with heavy snow fall, require a hood or enclosure to protect the regulator. Before installing the regulator, check for damage which might have occurred in shipment. Also check for and remove any dirt or foreign matter which may have accumulated in the regulator body or the pipeline. The outlets of the container valves should be cleaned to remove dirt or water. One method of doing 4

A A 8 5 5 3 SUPPLY 1 4 VIEW A-A T80219 Figure 3. Assembly Drawing CHANGEOVER REGULATOR SPRING Zinc 1D7515 Blue 1D6659 Blue T14058 Table 1. Manifold Spring Rates 749B Series (Type 64 Manifold Regulators) RESERVE OUTLET PRESSURE STANDARD SETTING AND RANGE 6 psi / 0.41 bar Adjustable Range 3 to 11 psi / 0.21 to 0.76 bar 5 psi / 0.35 bar Adjustable Range 5 to 15 psi / 0.35 to 1.0 bar R130 Series (Type 67C Manifold Regulators) 30 psi / 2.1 bar Adjustable Range 5 to 40 psi / 0.35 to 2.8 bar APPROXIMATE SUPPLY PRESSURE ABOVE RESERVE SETTING 9 psi / 0.62 bar 20 psi / 1.4 bar 14 psi / 0.97 bar this is by cracking the container valve open for a short time to blow out the dirt. Apply pipe compound to the male threads of the pipe. A relief valve is required downstream of all the regulators (except Types 64SR or HSRL) used on final-stage service. Both the Types 64SR and HSRL final-stage regulators have an internal relief valve. The internal relief valve opens when downstream pressure reaches approximately 125% to 250% above the set point for the Type 64SR or 200% to 300% above the setpoint for the Type HSRL. Be sure that the changeover manifold regulator assembly is supplying the correct pressure to the appliance. Failure to provide the correct pressure to the appliance can result in personal injury from fire and or explosion or damage downstream equipment. 5

20 6 12 5 7 L 8 3 4 1 2 T20923 9 APPLY LUBRICANT (L) Figure 4. Indicator Assembly Drawing To Change Settings in the Field: See Figure 3. 1. Remove both the supply handwheel (key 3) and reserve cap (key 4) from 1st stage manifold regulators. 2. Install a pressure gauge on the outlet side of the manifold, ahead of any final stage regulator. 3. Close the left side of the container shutoff valve. Loosen the adjusting screw nut (key 1) on the right side manifold regulator. Rotate the right side adjusting screw (key 5) clockwise to increase the reserve pressure or counter clockwise to decrease the reserve pressure. Monitor the manifold outlet pressure with the pressure gauge. Reserve pressure range should remain within the limits specified in Table 1. Exceeding the reserve limits specified in Table 1 for a given spring will prevent the manifold regulator from being able to produce the desired supply side pressures and could cause the loss of pressure control on the supply side. 4. Close the right side of the container valve and open the left side container valve. Loosen the adjusting screw nut (key 1) on the left side manifold regulator. Rotate the left side adjusting screw (key 5) clockwise to increase the reserve pressure or counter clockwise to decrease the reserve pressure. 5. IMPORTANT: Set both manifold regulators to the same reserve pressure setting. Tighten both adjusting screw nuts (key 1). 6. The indicator should show all red at the reserve setting desired. Replace the supply handwheel (key 3). The indicator should show all silver. If the reserve setting exceeds 8 psi / 0.55 bar, then the Type 803-21 indicator may not operate with the desired range. If the indicator does not show all red at the reserve pressure or all silver at the supply pressure, then some adjustment to the indicator will be required, or a pressure gauge will have to be installed in place of the indicator. 7. See Figure 4. To adjust the indicator remove the screw (key 6) and the lens (key 3). Using a small slotted screw driver, turn the adjusting screw clockwise to increase the pressure or 6

counterclockwise to decrease the pressure. The indicator should show red at about 3 psi / 0.21 bar above the new reserve setting. The indicator should show silver at about 6.5 psi / 0.45 bar above the new reserve setting. CAUTION Set both manifold regulators to the same reserve pressure setting. The supply handwheel when installed, will automatically provide the additional adjustment to set the supply pressure. Maintenance To avoid personal injury or equipment damage, do not attempt any maintenance or disassembly without first isolating the regulator from system pressure and relieving all internal pressure. Regulators that have been disassembled for repair must be tested for proper operation before being returned to service. Only parts manufactured by Fisher should be used for repairing Fisher regulators. Relight pilot lights according to normal startup procedures. Due to normal wear or damage that may occur from external sources, these regulators must be inspected and maintained periodically. The frequency of inspection and replacement of the regulators depends upon the severity of service conditions or the requirements of local, state, and federal regulations. Even under ideal conditions, these regulators should be replaced after 15 years from the date of manufacture or sooner should inspection reveal the need. Visually inspect the regulator each time a gas delivery is made for: 1. Improper installation. 2. Plugged or frozen vent. 3. Wrong regulator or no regulator in the system. 4. Internal or external corrosion. 5. Age of the regulator. 6. Any other condition that could cause the uncontrolled escape of gas. Failure to do the above could result in personal injury or property damage. Make sure the regulator vent, vent assembly, or vent tube does not become plugged by mud, insects, ice, snow, paint, etc. The vent screen aids in keeping the vent from becoming plugged, and the screen should be clean and properly installed. Replace any regulators that have had water in their spring case or show evidence of external or internal corrosion. Checking for internal corrosion may require complete removal of the adjusting screw and shut down of the gas system. Closely examine regulators directly connected to the container valve by means of a solid POL adaptor (horizontal mounting) for signs of corrosion. Correct any improper installations. Older regulators are more likely to catastrophically fail because of worn or corroded parts. Replace regulators over 15 years of age; other service or environmental conditions may dictate replacement of the regulator before it becomes 15 years old, refer to Fisher Bulletin LP-32. Regulator Repair Regulators that have been disassembled for repair must be tested for proper operation before being returned to service. Only parts manufactured by Fisher should be used to repair Fisher regulators. Be sure to give the complete type number of the regulator when corresponding with the factory. 7

LP-Gas Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872, USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc,. 2002, 2012; All Rights Reserved