Installation and Operation Manual

Similar documents
8675/8677/8678 OWNER S MANUAL

Canis Major Wet Dental / Treatment Lift Table. For models: CMDT-45 CMDT-WS-45 CMDT-60 CMDT-WS-60. User s Guide Rev.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Portable Massage Table User Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Heavy-Duty Hot Knife

Cocoa Patio Pond with Lit Spillway

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

OPERATION MANUAL ASPEN MASSAGE TABLE OR MULTI-PURPOSE LIFT TABLE. (800) (760) Fax: (760)

Prestan professional Training manikin

ROPV R40 E Series User Manual

Revolution Gurney Attachment

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Owner s Manual & Safety Instructions

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

HAS2400 Hepa Air Scrubber

6 digital caliper with case

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

User Instruction Manual

PC1131 Electric Air Compressor

Freedom8 ShoeBox Compressor Manual

FLANGED TWO-PIECE BALL VALVES

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Please Do Not Return This Product To The Store!

AIR INLINE METAL SHEAR

Installation Instructions Air Compressor Part # 2780, 2781

MODEL NUMBER: P PORTABLE COMPRESSOR

FLANGED TWO-PIECE BALL VALVES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

This document to be used with Hurley traditional Davits

walk with independence

Owner s Manual & Safety Instructions

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Copyright Trek Bicycle Corporation 2005 All rights reserved

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

ROLL FORMER CORP. ROLL FORMER CORP. Manufacturers of quality roll forming equipment leading

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

DLx1200, DLx1500, DLx1900, DLx2300 PULLING WINCHES. U.S. Patent Canadian Patent Model #DLx1200

1000 Lb. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Parts and Owners Manual

High Power Commercial Blenders

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

100C Air Compressor Kit

444C DUAL PERFORMANCE VALUE PACK

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

Model OPERATING INSTRUCTIONS. Due to continuing improvements, actual product may differ slightly from the product described herein.

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

PILOT PEDAL DRIVE INSTRUCTIONS

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

FLANGED MULTI-PORT BALL VALVES

TrekMill USER'S MANUAL MM5050

400C & 450C DUAL PERFORMANCE VALUE PACKS

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

User s Guide. VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System. For Models: Rev L (11/10/15)

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

600 / 600FC OWNER'S MANUAL

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

USER MANUAL

OPERATOR'S MANUAL GRASS CATCHER GC-4D

Model ASSEMBLY and OPERATING INSTRUCTIONS

OPERATOR S MANUAL. Fabric Grass Catcher PART NO PRINTED 1/2011 PRINTED IN USA

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

ULTRA QUIET & OIL FREE

COMPACT METAL bender 99826

2 Gallon Air Compressor

TABLE OF CONTENTS. INTRODUCTION to the AirVAC... 2 SAFETY INFORMATION... 3 DIMENSIONS & SPECIFICATIONS... 5 UNIT OVERVIEW... 6

200 PSI COMPRESSORS - MODEL NUMBERS

602 STRINGING MACHINE OWNER'S MANUAL

IMPORTANT SAFETY INSTRUCTIONS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

12" 8A Electric Snow Shovel

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

POWER ASSISTED BICYCLES OWNERS MANUAL

Owner s Manual W Automatic Aboveground Pool Cleaner

USER GUIDE TO POWER ASSISTED BIKES

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-300. Club Volleyball Gear. For fixed-height Basketball Hoop Systems

TWO KAYAK VERTICAL FOLD-DOWN CARRIER

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Accu-Tab PowerBase 3012AT by Axiall Corporation

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

Quadratec Delrin Door Hinge Pin Bushings for Jeep Wrangler YJ & TJ 94-06

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

User s Guide. VetPro 1000 Mobile Dental Delivery System. For Models:

SUP Owner s Manual.

Foldable Magne c Exercise Bike

WEATHERIZING INSTRUCTIONS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

FOLD AND ROLL PLAYBACK TABLE TENNIS TABLE

FOOSBALL ASSEMBLY, INSTRUCTIONS AND RULES PL

OPERATOR'S MANUAL. TOTALIFT - II LATERAL TRANSFER / TRANSPORT CHAIR Model No R02 AN

Transcription:

Installation and Operation Manual Model 416 Podiatry Examination Chair 1

2

Contents General Operation and Care of Equipment... 3 Important Instructions... 4 Unpacking... 5 Operation of Table s Features... 6 Care of Table... 9 Power Systems Maintenance... 9 General Operation and Care of Equipment This manual covers the instructions for the installation, operation, and normal care of the 416 Podiatry Examination Chair. For the purpose of this manual, the word TABLE is synonymous with the word CHAIR. This table has been designed to help reduce effort and work fatigue involved in the examination and treatment of an ever-increasing number of patients during the doctor s normal working day. The angle of the table top, (TILT), and the upper section of the table, (BACK), are adjusted by the use of an electromechanical power unit. The seat height of this table is fixed at 22-1/2". The angle of the table top, (TILT), may be varied from the horizontal to 30 degrees. The upper portion of the table, (BACK), can be adjusted from horizontal to a full chair sitting position, and the foot section may be manually extended - 8-7/8". The combination of these three motions provide a table which can not only be tailored to meet the individual doctor s requirements, but will meet the requirements of most examinations and treatments being performed in the doctor s office today. The FOOT CONTROL, accessory p/n 9A97002 (optional) and the HAND CONTROL, accessory p/n 9A93001, (standard) both can be used to control manual table adjustments and to enter and use preset programmed positions. They also contain an auto return feature which automatically sends the table to a preset, home, sitting position with the single touch of a button. SCOPE OF WARRANTY Midmark Corporation ( Midmark ) warrants to the original retail purchaser that it will repair or replace components of the domestic and international medical products manufactured by Midmark (except for components not warranted under Exclusions ) that are defective in material or workmanship under normal use and service. Midmark s obligation under this warranty is limited to the repair or replacement, at Midmark s option, of the applicable components. This limited warranty shall only apply to defects that are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. This warranty extends only to the first retail purchaser of a product and is not transferable or assignable. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of delivery to the original user, shall be one (1) year for all warranted products and components. (A) Ultrasonic cleaner products are guaranteed for a period of two (2) years after ship date when used in accordance with manufacturer s instructions. (B) Replacement parts and accessories carry a ninety (90) day warranty. OBTAINING WARRANTY SERVICE Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark.com; by phone at 1-800-MIDMARK; by facsimile at 1-800- 365-8631; or by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380. It is the retail purchaser s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser s expense. It is also the retail purchaser s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this warranty. EXCLUSIONS This warranty does not cover, and Midmark shall not be liable, for the following: (1) defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner; (2) products which are not installed, used, and properly cleaned and maintained as required in the Midmark Installation and/or Installation/ Operation Manual for the applicable product; (3) products considered to be of a consumable nature; (4) accessories or parts not manufactured by Midmark; (5) charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark; (6) costs and expenses of routine maintenance and cleaning; and (7) representations and warranties made by any person or entity other than Midmark. EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER: MIDMARK S ONLY OBLIGATION UNDER THIS WARRANTY IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDI- RECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR DELAYS, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS. NO AUTHORIZATION No person or firm is authorized to create or approve for Midmark any other obligation or liability in connection with the products. WARRANTY DISCLAIMER THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACE- MENT OF DEFECTIVE PARTS. STATUTE OF LIMITATIONS No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any, or for any other claim arising out of or relating to the products, more than ninety (90) days following expiration of the limited warranty period. 3

Important Instructions Safety First: The primary concern of the Midmark Corporation is that this equipment be operated and maintained with the safety of the patient and doctor in mind. To assure safer and more reliable operation: 1. Read this manual before installing or operating your equipment. 3. Be sure that you understand the instructions contained in this manual before attempting to install or operate this equipment. 4. This manual should remain permanently affixed to the equipment. 2. It is the responsibility of the purchaser to assure that appropriate personnel are informed on the contents of this manual. Warnings Throughout this manual are Notes, Cautions, and Danger warnings that call attention to particular procedures. The items are used as follows: 4 A note is used to amplify an operating procedure, practice, or condition. CAUTION A CAUTION is used for an operating procedure, practice, or condition which, if not correctly followed, could result in equipment damage. A is used for an operating procedure, practice, or condition which, if not correctly followed, could result in personal injury. For your personal safety and that of your patients, all warnings are repeated here. Become thoroughly familiar with them and observe them at all times. 1. Do not lift at point B, fig. 1. This is not a supported area. Lifting at this point could cause personal injury or damage to the table. 2. Use 115 volt - 60 hertz alternating current only. Failure to do so could result in personal injury or equipment damage. 3. Do not use this table in an explosive or oxygenenriched atmosphere. Using the table in these situations could cause personal injury or equipment damage. 4. All exposed metal parts of the table are electrically grounded. When performing a cauterization or similar treatment, the patient must be insulated from the metal portions of the table by a nonconductive material. Failure to do so could result in electrical shock or burns to the patient. 5. If the table malfunctions, immediately remove your foot or hand from the control switch, unplug the power cord from the wall receptacle, and assist the patient from the chair. 6. Keep your arms and legs and your patent s arms and legs clear of all moving parts when changing table positions. Failure to do so could result in personal injury. 7. Keep all foreign objects away from the foot switch or hand control so that the switches are not accidently activated. Failure to do so could result in personal injury or damage to the table. 8. Be sure all persons and equipment are clear of the table before activating the auto return. Failure to do so could result in personal injury or damage to the table. 9. Be sure all persons and equipment are clear of the table before activating any programmed positions. Failure to do so could result in personal injury or equipment damage. 10.Failure to return the foot section or debris tray to its storage position before lowering or auto returning the chair tilt could result in personal injury or equipment damage. 11. Failure to perform a periodic inspection of your equipment could result in personal injury or equipment damage.

Unpacking and Installation UNPACKING: To avoid damaging the table when unpacking, do not use a knife or other sharp object to open the carton. To begin, Break the bands holding down the carton to the base. Lift carton off the base and remove the poly bag by pulling the staples loose around the skid. Remove the 4 bolts holding the table to the skid at point A and lift table up out of the skid by points C, not at B. C FIGURE 1 B A Do not lift at point B, fig. 1. This is not a supported area. Lifting at this point could cause personal injury or damage to the table. Use 115 volt - 60 hertz alternating current only. Failure to do so could result in personal injury or equipment damage. A C B Do not use this table in an explosive or oxygen-enriched atmosphere. Using the table in these situations could cause personal injury or equipment damage. All exposed metal parts of the table are electrically grounded. When performing a cauterization or similar treatment, the patient must be insulated from the metal portions of the table by a nonconductive material. Failure to do so could result in electrical shock or burns to the patient. ELECTRICAL The electrical rating of the Model 416 is 115 V.A.C., 60 Hertz, 6 Amperes. The three pronged grounding plug on the table power cord must be inserted into a matching three-pronged, grounding, non-isolated correctlypolarized 120-volt receptacle. The single table power cord provides power to all of the table s electromechanical actuators and to both of the duplex receptacles located on lower sides of the seat (Item A, Fig 2). This equipment is not designed for continuous operation. If the unit is operated continually, a thermal overload switch will shut off the actuator motor. If normal Operation ceases, immediately remove your foot or hand from the control switch. The overload switch will automatically reset after the motor cools (minimum 15 minutes). The 416 table actuators are fused to protect the operator as well as the table. Should the unit fail to start after a cool down period, contact an authorized service center to investigate the cause of the failure. 5

Operation of Table Power Features For optimal performance, allow the table to reach room temperature before using. Plug table power cord into proper receptacle as described above under ELECTRICAL. DISABLE SWITCH: A disable switch which interrupts power to all table actuator motors is located beneath the duplex receptacle on the left-hand side of the table (B, Fig. 2). When the switch is positioned toward the foot end of the table, all controls are disabled. Changing the position of the switch toward the head end of the table allows power to be supplied for table positioning. To insert plug, align plug tab with notch in the receptacles. Push inward until tab clicks into the locked position. To remove plug, depress tab while pulling on the plug. The table may be operated with the hand control connected into the foot control receptacle if so desired, or vice versa. Turn the disable switch, (B, Fig. 2), towards the head end to power up the table. Then press AUTO RETURN. The table s actuator motors will run and shut down automatically. You may now begin to position the table. CAUTION Always disable the controls to the table when it is required to remain in a fixed position during cauterization or when the table is left unattended. If the table malfunctions, immediately remove your foot or hands from the control switch, unplug the power cord from the wall receptacle, and assist the patient from the chair. Insert hand control cord into the receptacle of both the table, (C, Fig. 2), and into the receptacle in the bottom of the hand control, (A, Fig. 3). A Keep your arms and legs and your patent s arms and legs clear of all moving parts when changing table position. Failure to do so could result in personal injury. B C Keep all foreign objects away from the foot switch or hand control so that the switches are not accidentally activated. Failure to do so could result in personal injury or damage to the table. FIGURE 2 6

Patient Positioning (Manual) The table is now ready for operation. If the table does not respond to attempts to move the table using the hand control or foot control, refer to reinitialization steps on page 8. Your Model 416 can actuate 2 power motions, BACK and TILT. ADJUSTMENT OF TABLE BACK SECTION To raise the upper portion of the table from the horizontal toward the chair position, depress the button marked BACK UP and hold down until the desired position is obtained or the chair position is achieved. To lower the upper portion of the table from the chair position, depress the button marked BACK DOWN and hold down until the desired position is obtained or the most horizontal position is achieved. DO NOT continue to hold the control switch down after the table reaches either of the extreme positions. Extended operation of the motor at either of these positions will overheat the actuator motor. ADJUSTMENT OF THE TABLE TOP ANGLE To tilt the table top, depress the button marked TILT UP and hold down until the desired degree of tilt is obtained or until the table reaches its maximum amount of movement. To bring the table top angle down toward horizontal, depress the button marked TILT DOWN and hold down until the desired position is obtained or the horizontal position is achieved. DO NOT continue to hold the control switch down after the table reaches either of the extreme positions. Extended operation of the motor at either of these positions will overheat the actuator motor. Be sure all persons and equipment are clear of the table before activating the auto return. Failure to do so could result in personal injury or damage to the table. AUTO RETURN The auto return will lower any amount of tilt and raise the back, moving the table motions simultaneously until the table reaches a sitting patient entry or exit position. To activate the auto return, depress the green button marked AUTO RETURN just once. If for any reason the AUTO RETURN must be stopped, press the red button marked STOP or any other button in an emergency. FIGURE 3 A Patient Positioning (Programmable) The table is now ready for operation. If the table does not respond to attempts to move the table using the hand control or foot control, refer to reinitialization steps on page 8. The model 416 table can be programmed to keep up to four doctor specified positions in its computer memory. Once the position is placed in memory, only one switch or button must be activated to simultaneously operate both power motions of the table. This allows quick positioning for frequently performed procedures. 7

PROGRAMMING THE TABLE To store a table position in the computer memory, the following steps must be taken: Be sure all persons and equipment are clear of the table before activating any programmed positions. Failure to do so could result in personal injury or equipment damage. For optimal results, always make certain the table is in its home, auto returned, position before beginning to enter any programmed positions. 1. Using either the foot or hand control, (Fig. 3 & 4), move the table to the desired position using one function at a time and without starting and stopping each function more than once. 2. Press the yellow switch or button marked PROGRAM once, holding down for 2 or 3 seconds. 3. Next press one of the blue switches or buttons with the number you choose to assign to this position. 4. Press the green switch or button marked AUTO RETURN, allow the table to run to the preset home position. 5. Press the blue, numbered, program switch or button you have just entered and the table will run all actuators simultaneously until the desired position is reached. FIGURE 4 If for any reason the PROGRAMMED POSITION- ING must be stopped, press the red switch or button marked STOP or any other switches or buttons in an emergency. Should the doctor wish to change a PROGRAMMED POSITION, simply go to the steps listed above. The old position will be replaced by the new. In the event of a power outage, your model 416 will maintain its memory up to four days after the loss of power. REINITIALIZATION Depress the PROGRAM, POSITION 1, and POSITION 2 switches simultaneously for a minimum of five seconds. Release these switches and depress the AUTO RETURN switch for seven seconds or until the table begins to move. Release the AUTO RETURN switch. The motors will continue to run for approximately eighteen seconds. The table is now ready for normal operation. If table malfunction persists, then contact your dealer or Midmark s service department at 1-800-MIDMARK. FOOT SECTION EXTENSION To accommodate taller patents your table s length can be extended by holding knob, (A, Fig. 5), down while pulling outward on the foot assembly. Release knob and push the foot section assembly inward until it rests against the seat. 8

A B Care of Table CARE OF UPHOLSTERY The upholstery material used to cover the top of the table is resistant to most medicinal-type stains, but may be damaged by solvents and dyes. Regular care should be maintained by daily wiping with a damp cloth or sponge and a periodic cleaning with a mild soap and water solution. Any fluid spilled on the upholstery should be removed as quickly as possible. In the case of stain, attempt to remove it with soap and water. FIGURE 5 DEBRIS TRAY To expose the debris tray for use, simply pull outward. By loosening the side knobs, (B, Fig. 5), the tray can be positioned parallel to the floor and locked (knobs tightened). To clean the tray, loosen the knobs and turn it over or remove it entirely from the chair by lifting the tray out of the notches in the support arms. Failure to return the foot section or debris tray to its stored position before lowering or auto returning the table could result in personal injury or equipment damage. Disinfecting: Premium uph. use 20:1 diluted bleach solution CARE OF PAINTED METAL SURFACES All painted metal surfaces should be wiped clean with a clean, soft cloth weekly, and a periodic application of paste wax to smooth paints will preserve the finish luster. CARE OF PLASTIC COMPONENTS All the plastic table parts should be cleaned with a clean damp cloth weekly. Any soiled areas may be cleaned with soap and water or other household cleaners. CARE OF MOVING PARTS All moving parts, such as the foot section slides, back hinges, and debris tray assembly should be lubricated occasionally with a light machine oil to help insure quiet, dependable operation. Maintenance Little routine maintenance is required other than a periodic inspection of the electrical cords to make sure they are free of cuts or damage and clear of moving parts. Due to the mechanical, electrical nature of this equipment, periodic inspections at six (6) month intervals by your dealer are recommended. FIGURE 6 Failure to perform a periodic inspection of your equipment could result in personal injury or equipment damage. 9

S 10

11

R Copyright by Midmark Corporation 1989 12 Midmark Corporation, Versailles, Ohio 45380 U.S.A. 937-526-3662 TELEX 288007 FAX 937-526-5542 003-0439-00 Rev. F (8/15)