Swift FX Nano Swift FX Nano for Her

Similar documents
Mirage FX. User Guide. English NASAL MASK

AirFit Nasal Mask. User guide N10. English

Mirage Micro. User Guide. English. nasal mask

Swift LT NASAL PILLOWS SYSTEM. User Guide English

User guide English r1 Quattro Air Amer Multi Multi Book.indb 1 14/07/ :30:10 AM

Mirage FX. User Guide. English NASAL MASK

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR NASAL PILLOWS SYSTEM

Fitting / Mise en place / Colocación / Ajuste

Fitting / Mise en place / Colocación / Ajuste

User Guide. English. Nasal Pillows System

User Guide. English. Nasal Pillows System

Mirage Micro for Kids. nasal mask

Mirage Vista Nasal Mask

Quattro Air Non-vented full face mask

Quattro FX Quattro FX for Her

English USER GUIDE User guide

Mirage Micro for Kids

Swift FX Nano Swift FX Nano for Her

Mirage FX. User Guide. English NASAL MASK

Mirage Micro. User Guide. English. nasal mask

Nasal mask. User guide. User guide English

English. ivolve Full Face Mask. User Manual

English USER GUIDE User guide

Mirage Quattro FULL FACE MASK

Full face mask. User guide English

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Full face mask. User guide. English

Mirage Quattro FULL FACE MASK

Mirage Liberty. User Guide 61850/ APAC ENG MIRAGE LIBERTY USER r2 cover.qxp 3/04/2007 4:39 PM Page 1. English FULL FACE MASK

Mirage FX. User Guide. English NASAL MASK

Hospital masks. User guide. English

Instructions for Use. OptiLife Nasal Lab Mask

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Quattro FX Quattro FX for Her

AirFit Nasal Mask. User guide N10. English

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

Invacare Twilight II Nasal Mask

User guide English book.indb 1 14/07/ :51:19 AM

Pixi. User Guide. Pixi TM PEDIATRIC MASK. English. pediatric MASK

Mirage Activa LT. User Guide. English. nasal mask

ComfortGel Full. Full Face Mask

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Log on now to to find useful tips on managing your treatment. Mirage Swift II. Nasal Pillows System. User Guide.

Ultra Mirage II Nasal Mask

Full face mask. User guide. English

Full face benefits in a compact size

EasyFit SilkGel Full Face Mask

Mirage Kidsta Nasal Mask

Please read the entire Information and Welcome Guides before using your device.

English Please read the entire Information and Welcome Guides before using your device.

English Please read the entire Information and Welcome Guides before using your device.

Micro Dial-Flowmeter. Instructions for Use

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

EasyFit Full Face Mask, Silicone EasyFit Full Face Mask, Gel

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

S8 Lightweight II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICE

Oxygen Dialflow Meter. Instructions for Use

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Rev. B. Operating Instructions

Owner s Manual. Model H4685

This mask changes everything

Oxygen Dialflow Meter. Instructions for Use

Dialflow Regulator. Instructions for Use

Pressure Regulator. Instructions for Use

SOTR Special Operations Tactical Respirator

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

S8 Series II. S8 AutoSet Spirit II S8 AutoScore II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICES

Contents Warnings, Cautions, and Notes Contents of the Package Introduction to the Harmony S/T A Tour of the Harmony S/T...

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR. English. nasal pillows system

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Model ASSEMBLY and OPERATING INSTRUCTIONS

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

English

OPERATING MANUAL EASY-LOAD PUMP HEADS

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

User guide User guide English

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Copyright Trek Bicycle Corporation 2005 All rights reserved

User manual STARLOCK. Careways International - Innovation Quality Performance

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

Pressure Injection Cell Operator s Manual

SASK-A-POLE OWNERS AND USERS MANUAL

2018 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice.

OPERATING MANUAL EASY-LOAD PUMP HEADS

Bimini Top, Bimini Top Plus for Jeep Wrangler Vehicles Items # , # and #

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Owner s Manual & Safety Instructions

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

User guide User guide English

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

M5400 Operators Manual

Transcription:

Swift FX Nano Swift FX Nano for Her NASAL MASK User Guide English

Did you know? Replacing your mask and supplies is one of the most important steps in maintaining effective therapy Replace when... The cushion is discolored. The cushion is cracked, torn or damaged in any way. The headgear is stretched and needs to be tightened more than when it was new. The short tube is stretched or punctured. What to do... Consult your equipment provider to learn what replacement schedule may be available through your insurance policy.

Swift FX Nano Swift FX Nano for Her NASAL MASK / MASQUE NASAL / MASCARILLA NASAL / MÁSCARA NASAL Fitting / Mise en place / Colocación / Ajuste 1 2 3 4 5 6 i

Removal / Retrait / Remoción / Remoção Disassembly / Démontage / Desmontaje / Desmontagem 1a b 2 ii

Reassembly / Remontage / Montaje / Remontagem 1 2 3 4 5 6 7 iii

A 2 B 3 1 4 5 10 11 12 6 7 C 8 9 D E iv

Mask components / Composants du masque / Piezas de la mascarilla / Componentes da máscara Item / Désignation / Artículo / Item Description / Description / Descripción / Descrição 1 Headgear right / Harnais droit / Arnés derecho / Lateral direita do arnês 2 Top buckle / Boucle supérieure / Hebilla superior / Fivela superior 3 Back strap / Sangle arrière / Correa posterior / Correia traseira 4 Back strap fastener / Attache sangle arrière / Broche de la correa posterior / Fecho da correia traseira 5 Headgear left / Harnais gauche / Arnés izquierdo / Lateral esquerda do arnês 6 Mask cushion / Bulle du masque / Almohadilla / Almofada da máscara 7 Soft wraps / Housses souples / Fundas blandas / Envoltórios macios 8 Short tube / Tuyau court / Tubo corto / Tubo curto 9 Swivel / Pièce pivotante / Pieza giratoria / Peça giratória Part number / Code produit / Número de pieza / Nº da peça Swift FX Nano Swift FX Nano for Her 61530 (2 x G) 61544 (2 x P) v

Item / Désignation / Artículo / Item Description / Description / Descripción / Descrição 10 Vent / Orifice de ventilation / Ventilación / Respiradouro 11 Elbow / Coude / Codo / Cotovelo 12 Swivel ring / Anneau pivotant / Aro de la pieza giratoria / Anel da peça giratória A Complete system / Système complet / Sistema completo / Sistema completo B Frame system / Entourage complet / Sistema de armazón / Sistema da armação C Short tube assembly / Ensemble tuyau court / Conjunto del tubo corto / Conjunto do tubo curto D Mask cushion / Bulle du masque / Almohadilla / Almofada da máscara E Headgear / Harnais / Arnés / Arnês Part number / Code produit / Número de pieza / Nº da peça Swift FX Nano 62200 (Std) 62251 (W) 62220 (Std) 62271 (W) 62236 (1) 62237 (10) 62230 (Std) 62281 (W) Swift FX Nano for Her 62201 (S) 62221 (S) 62244 (1) 62245 (10) 62231 (S) 62238 62248 S: Small / Petit / Pequeño / Pequeno Std: Standard / Standard / Estándar / Padrão W: Wide / Large / Ancho / Largo G: Gray / Gris / Gris / Cinza P: Pink / Rose / Rosa / Rosa vi

English Swift FX Nano Swift FX Nano for Her NASAL MASK Thank you for choosing the Swift FX Nano / Swift FX Nano for Her. Please read the entire manual before use. Intended Use The Swift FX Nano / Swift FX Nano for Her channels airflow noninvasively to a patient from a continuous positive airway pressure (CPAP) or bilevel device. The Swift FX Nano is: to be used by patients >66 lb (30 kg) for whom positive airway pressure has been prescribed intended for single-patient re-use in the home environment and multipatient re-use in the hospital/institutional environment. GENERAL WARNINGS The vent holes must be kept clear. The mask should only be used with CPAP or bilevel devices recommended by a physician or respiratory therapist. The mask should not be used unless the device is turned on. Once the mask is fitted, ensure the device is blowing air. Explanation: CPAP and bilevel devices are intended to be used with special masks (or connectors) which have vent holes to allow continuous flow of air out of the mask. When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation. This applies to most models of CPAP or bilevel devices. Follow all precautions when using supplemental oxygen. English 1

Oxygen flow must be turned off when the CPAP or bilevel device is not operating, so that unused oxygen does not accumulate within the device enclosure and create a risk of fire. Oxygen supports combustion. Oxygen must not be used while smoking or in the presence of an open flame. Only use oxygen in well ventilated rooms. At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate. This warning applies to most types of CPAP or bilevel devices. The technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the CPAP or bilevel device function. Discontinue using this mask if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist. Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental condition. If symptoms occur, consult your physician or dentist. As with all masks, some rebreathing may occur at low CPAP pressures. Refer to your CPAP or bilevel device manual for details on settings and operational information. Remove all packaging before using the mask. Using your mask When using your mask with ResMed CPAP or bilevel devices that have mask setting options, refer to the Technical specifications section in this user guide for mask selection options. 2

For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative. Fitting The fitting illustrations in this user guide show the sequence for obtaining the best fit and comfort when using your mask. A diagram showing the names of parts can be found in the Mask Components diagram near the beginning of this guide. Fitting steps 1. Ensure that the bottom of the cushion opening is aligned with the bottom of your nose. Place the mask over your nose. 2. Pull the headgear over your head. The buckle on the top strap should sit on top of your head and the fabric back strap should go around the back of your head. 3. Adjust the top strap by pulling the strap through the buckle, one notch at a time. Do not overtighten. The mask should sit comfortably over your nose and the back strap should sit just above your ears. 4. Adjust the fasteners on the fabric back strap until the mask is comfortably sealed. The fabric back strap can be positioned over or under the hair. 5. Adjust the mask cushion until it sits comfortably on your nose. 6. Finally, connect the free end of the short tube assembly to the device air tubing. If the mask leaks, readjust the fabric back strap before the top strap. Removing your mask To remove your mask pull the mask and headgear by the fabric back strap up and over your head. English 3

Disassembly Refer to the disassembly illustrations in this user guide. A diagram showing the names of parts can be found in the Mask Components diagram near the beginning of this guide. Disassembly steps 1. Remove the headgear by slightly twisting each headgear arm and pulling away from the node on the mask cushion. 2. Peel the mask cushion away from the swivel ring. Note: The headgear straps are not intended to be disassembled and can be washed together. Reassembly Refer to the reassembly illustrations in this user guide. A diagram showing the names of parts can be found in the Mask Components diagram near the beginning of this guide. Reassembly steps 1. Using your forefinger and thumb to stretch the inside of the mask cushion, insert the swivel ring into the mask cushion. 2. Allow the mask cushion to sit in the groove on the swivel ring. The mask cushion is correctly positioned when it is located in the swivel ring groove with no gaps. Ensure that the swivel ring is not pushed all the way into the mask cushion. 3. Rotate the elbow to ensure it moves freely in the swivel ring. 4. Thread the top strap through the top buckle with the notches facing up. 5. Hold the headgear arm with the opening facing you. Latch the headgear arm onto the node on the mask cushion. Make sure that the text on the headgear lines up with the text on the mask cushion. 6. Repeat the previous step with the other headgear arm. Ensure that the headgear straps are not twisted. 7. Thread the fabric back strap through each side of the headgear, then fold over to secure. Ensure that the fastener is on the outside with the ResMed logo facing out. 4

Cleaning your mask in your home Your mask and headgear should only be handwashed by gently rubbing in warm (approximately 86 F/30 C) water using mild soap. All components should be rinsed well with drinking quality water and allowed to air dry out of direct sunlight. WARNING Do not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol or products that smell strongly (eg, citrus) to clean any of the mask components. Residual vapours from these solutions can be inhaled if not rinsed thoroughly. They may also damage the mask, causing cracks. CAUTION If any visible deterioration of a system component is apparent (cracking, crazing, tears etc), the component should be discarded and replaced. Avoid connecting flexible PVC products (eg, PVC tubing) directly to any part of the mask. Flexible PVC contains elements that can be detrimental to the materials of the mask, and may cause the components to crack or break. Daily/After each use: To optimize the mask seal, facial oils should be removed from the cushion after use. Handwash the separated mask components (excluding headgear). If the vent or rotating parts such as the swivel, swivel ring or ball joint require cleaning, use a soft bristle brush. Weekly: Handwash the headgear. It may be washed without being disassembled. English 5

Reprocessing the mask between patients This mask should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, www.resmed.com/masks/sterilization/americas. If you do not have internet access, please contact your ResMed representative. Troubleshooting Problem/possible cause Solution Mask is too noisy. Vent is blocked or partially blocked. Elbow inserted incorrectly. Mask is leaking. If the vent requires cleaning, use a soft bristle brush. Remove the elbow from the mask and then reassemble according to the instructions. Ensure that the swivel ring on the elbow has not been inserted too far into the cushion. Refit or reposition your mask. Readjust the back strap to bring the mask closer to the face and improve your seal. Check that your mask is assembled correctly. 6

Problem/possible cause Solution Mask leaks around face. Mask is not positioned correctly. Mask may have been fitted incorrectly. Cushion membrane is creased or folded. Mask is not tightened correctly. Mask may be the wrong size. Check that the ResMed logo is facing upward on the top of the cushion across the bridge of your nose. Pull the mask away from your face and reposition, ensuring that the lower corners of the mask fully enclose your nose. If necessary, readjust the top strap to keep the mask in the right place. Remove and refit your mask according to the fitting instructions. Ensure you position the cushion correctly over your nose before pulling the headgear over your head. Do not slide the mask down your face during fitting as this may lead to folding or curling of the cushion. Ensure that the headgear straps are not overtightened or loose. Readjust the back strap to bring the mask closer to the face and improve your seal. Check that the headgear is not twisted. Talk to your clinician. Mask does not fit properly. Mask is incorrectly assembled. Mask may be the wrong size. Cushion may be dirty. Disassemble the mask, then reassemble according to the instructions. Ensure that the swivel ring on the elbow has not been inserted too far into the cushion. Check that the printing on the left headgear strap (Swift FX) aligns to the printing on the cushion arm (Nano). Talk to your clinician. Clean cushion according to the instructions. English 7

Technical Specifications Pressure-flow curve The mask contains passive venting to protect against rebreathing. As a result of manufacturing variations, the vent flow rate may vary. Pressure Flow (cm H2O) (L/min) 4 20 8 29 12 37 16 43 20 49 22.5 52 30 61 Dead space information Therapy pressure Resistance Environmental conditions Gross dimensions Physical dead space is the empty volume of the mask to the end of the swivel. Using the wide cushions it is 125 ml. 4 to 30 cm H2O Drop in pressure measured (nominal) at 50 L/min: 0.5 cm H2O at 100 L/min: 2.0 cm H2O Operating temperature: +41 F to +104 F (+5 C to +40 C) Operating humidity: 15% to 95% relative humidity non-condensing Storage and transport temperature: -4 F to +140 F (-20 C to +60 C) Storage and transport humidity: up to 95% relative humidity non-condensing Small: 16.9" (H) x 3.94" (W) x 2.95" (D) (430 mm (H) x 100 mm (W) x 75 mm (D)) Standard: 16.9" (H) x 4.09" (W) x 2.95" (D) 430 mm (H) x 104 mm (W) x 75 mm (D) Wide: 16.9" (H) x 4.49" (W) x 2.95" (D) 430 mm (H) x 114 mm (W) x 75 mm (D) Mask fully assembled with short tube assembly (no headgear) 8

Mask setting options For S9: Select 'Pillows' For other devices: Select 'SWIFT' (if available), otherwise select 'MIRAGE' as the mask option. Notes: The mask system does not contain BPA, PVC, DEHP or phthalates. This product is not made with natural rubber latex. The manufacturer reserves the right to change these specifications without notice. Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a dry place out of direct sunlight. Disposal This mask does not contain any hazardous substances and may be disposed of with your normal household refuse. English 9

Symbols The following symbols may appear on your product or packaging: Catalog number Batch code Humidity limitation Temperature limitation Fragile, handle with care Not made with natural rubber latex Manufacturer European Authorized Representative Keep away from rain This way up Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Caution, consult accompanying documents Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician) 10

Limited warranty ResMed Ltd (hereafter ResMed ) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke. Warranty is void on product sold, or resold, outside the region of original purchase. Warranty claims on defective product must be made by the initial consumer at the point of purchase. This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office. English 11

Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA ResMed (UK) Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire OX14 4RW UK See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip Swift is a trademark of ResMed Ltd and is registered in U.S. Patent and Trademark Office. Velcro is a trademark of Velcro Industries B.V. 2014 ResMed Ltd.

1 2 3 4 5 6 TM Swift FX Nano for Her NASAL MASK

1 2 3 4 5 6 628034/5 2014-05 Swift FX Nano / Swift FX Nano for Her USER AMER MULTI TM Swift FX Nano NASAL MASK 628034 Global leaders in sleep and respiratory medicine www.resmed.com