Non-Return Valve SRK 22A

Similar documents
Non-Return Valve SRK 22A. Original Installation Instructions

Inverted Bucket Steam Trap IB 16A-7

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

Steam Trap MK 25/2 MK 25/2S

Shut-Off Valve GAV 56F. Original Installation Instructions

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Control Valves ZK 610 ZK 613

UNA 45 UNA 46 UNA 46A

Control Valve ZK 29. Original Installation Instructions

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

GESTRA. GESTRA Steam Systems CB 1... CB 2... Installation Instructions Swing Flap Non-Return Valves CB 1..., CB 2...

Type BBS-03, BBS-05, BBS-06, BBS-25

GESTRA Steam Systems AK 45. Installation Instructions Condensate Drain Valve AK 45

Pressure relief valve

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Declaration of Conformity as per Directive 97/23/EC

Flowmeter. Original operating manual DFM

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

PV4 and PV6 Piston Valves

Manual Actuated Boiler Blowdown Valves

TP1 and TP2 Temporary Cone Shaped Strainers

Pressure relief valve

CVS10 Sanitary Check Valves

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

AVM7 Stainless Steel Thermostatic Air Vent

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

DCV6 Disc Check Valve

Operating and maintenance manual Filter and reducing station Series / 1.0

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Siphon vessel / Priming aid

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

TSS21 Sealed Thermostatic Steam Tracer Trap

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

MF2M Monnier Miniature Compressed Air Filter

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Declaration of Conformity as per Directive 97/23/EC

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Dual Solenoid Gas Valve Installation

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Installation & Operation Manual Proven Quality since 1892

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

6301 TYPE CAST IRON SAFETY VALVES

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

GI Series Diaphragm Pressure Gauge Guard

Pressure Reducing Valve for Steam Type 2333 A

Instruction Manual Contact Pressure Vacuum Gauge

for the of and the EM55-1

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

S and SF Inverted Bucket Steam Traps

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SCA Series Inverted Bucket Steam Traps

TITAN FLOW CONTROL, INC.

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

ML3M Monnier Miniature Compressed Air Lubricator

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Spirax Compact FREME Flash Recovery Energy Management Equipment

Pressure Reducing Valve DMV 750

Transcription:

Non-Return Valve SRK 22A Original Installation Instructions 819238-02

Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose... 3 Basic safety notes... 4 Qualification of personnel... 4 Protective gear... 5 Typographic features of warning notes... 5 Formatting features for warnings of property damage... 5 Description... 5 Scope of supply and equipment specification... 5 Task and function... 7 Storing and transporting the equipment... 8 Storing the equipment... 8 Transporting the equipment... 8 Mounting and connecting the equipment... 9 Preparing installation... 9 Connecting the equipment... 9 Operation... 11 After operation... 11 Removing external dirt deposits... 11 Servicing and repairing the equipment and installing spare parts... 11 Troubleshooting... 12 Putting the equipment out of operation... 13 Removing harmful substances... 13 Removing the equipment... 13 Re-using equipment after storage... 14 Disposing of the equipment... 14 Technical data... 15 Dimensions and weights... 15 Pressure & temperature ratings... 17 Opening pressures [mbar]... 17 Pressure drop chart... 18 Manufacturer's declaration... 19

Foreword This installation & operating manual will help you use the valve SRK 22A safely and efficiently for its intended purpose. This valve will be called equipment in this document. This installation & operating manual is intended for anyone commissioning, using, operating, servicing, cleaning or disposing of this equipment and, in particular, for professional after-sales service technicians, qualified personnel and authorised and trained staff. All of these persons must read and understand the content of this installation & operating manual. Following the instructions given in this installation & operating manual helps avoiding danger and increases the reliability and service life of the equipment. Please note that in addition to the instructions given in this installation & operating manual you must also observe all locally applicable rules and regulations concerning the prevention of accidents as well as approved safety guidelines for good professional practice. Availability Keep this installation & operating manual together with the plant documentation for future reference. Make sure that this installation & operating manual is available to the operator. The installation & operating manual is part of the equipment. Please hand over this installation & operating manual when selling the equipment or passing it on. Formatting features in the document Certain text elements of this installation & operating manual feature a specific typographic design. You can easily distinguish the following text elements: Standard text Cross-reference Listing Sub-items in listings Steps for action. Safety Here you will find additional useful information and tips serving to assist you in using the equipment to its fullest potential. Use for the intended purpose The non-return valve SRK 22A ensures unidirectional flow in pipes by preventing a backflow of fluids. The equipment must only be used within the allowable pressure and temperature limits and only if the chemical and corrosive influences on the equipment are taken into account. Correct use includes compliance with the instructions given in this installation & operating manual, in particular obedience to all safety instructions. Any other use of the equipment is considered to be improper. Note that the equipment is also used incorrectly if the materials of the equipment are not suitable for the fluid. 3

Basic safety notes Risk of severe injuries The equipment is under pressure during operation and may be hot. Before carrying out any work on the equipment make sure that the following requirements are met: The pipes must be depressurized (0 bar). The fluid must be completely removed from the pipes and the equipment. During work on the equipment the installation must be switched off and protected against unauthorised or unintended activation. The pipes and the equipment must have cooled down to room temperature (approx. 20 C). If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment. Before working on the equipment make sure that it is completely decontaminated. Always wear the protective clothing prescribed for contaminated areas when working on the equipment. The equipment must only be used with fluids that do not attack the material and the gaskets and sealings of the equipment. Otherwise leaks may occur and hot or toxic fluid could escape. The equipment and its component parts must only be mounted or removed by qualified personnel. A qualified person must be acquainted with and experienced in the following: Making pipe connections. Selecting suitable lifting gear and understanding the rules for its safe use. Working with dangerous (contaminated, hot or pressurized) fluids. Risk of minor injuries Sharp edges on internals present the danger of cuts to hands. Always wear industrial gloves when servicing the equipment. If the support of the equipment during installation is insufficient the equipment might fall down, thereby causing bruises or injuries. Make sure the equipment is safely held in place during installation and cannot fall down. Wear protective safety footwear. Information on property damage or malfunctions Malfunctions will occur if the equipment is installed in a wrong position or with the flow arrow pointing in the opposite direction of the fluid flow. This may result in damage to the equipment or the installation. Make sure that the flow arrow on the equipment body matches the indicated direction of the fluid flow in the pipe. If the material is unsuitable for the fluid, increased wear may occur and fluid may escape. Make sure that the material is suitable for the fluid used in your installation. Qualification of personnel A qualified person must be acquainted with and experienced in the following: the pertinent on-site rules and regulations for preventing fire and explosions as well as industrial safety regulations working on pressure equipment making pipe connections working with dangerous (hot or pressurized) fluids lifting and transporting loads observing all notes and instructions in this installation & operating manual and the applicable documents 4

Protective gear The required protective gear depends on the types of fluid used and the regulations on site. For more information on suitable safety clothing and safety gear refer to the safety data sheet of the fluid in question. Protective gear comprises the following items: protective helmet work boots industrial leather gloves Typographic features of warning notes DANGER Notes with the heading DANGER warn against imminent dangerous situations that can lead to death or serious injuries. Formatting features for warnings of property damage Attention! This information warns of a situation leading to property damage. Description Scope of supply and equipment specification Scope of supply Our equipment is delivered packed and ready for assembly. WARNING Notes with the heading WARNING warn against possibly dangerous situations that could lead to death or serious injuries. CAUTION Notes with the heading CAUTION warn against dangerous situations that could lead to minor or moderate injuries. 5

Equipment specification No. Designation 1 Spring retainer 2 Spring to close 3 Valve disc 4 Guide ribs 5 Body No. Designation 6 Nameplate (lasered on the body) 7 Seat (not shown) 8 Direction of flow 6

End connections The equipment is designed for clamp connections to DIN 32676. Other end connections are not available. Name plate The following items are indicated on the body: Manufacturer Type designation Nominal size Design temperature Design pressure Direction of flow Material Batch code Date of manufacturing Task and function The non-return valve SRK 22A ensures unidirectional flow in pipes by preventing a backflow of fluids. The valve disc is pressed against the seating surface in the event of reverse flow. As a result, the closed valve prevents a backflow of fluid. The guide ribs ensure correct alignment of the valve disc. When fitted with springs, the equipment can be installed in any plane. Different types of springs with different strengths are available. The force of the spring ensures that the valve only opens when the fluid flows in the right flow direction. Application of European Directives Pressure Equipment Directive The equipment conforms to this directive (see "Manufacturer's Declaration" section) and can be used for the following media: Fluids of group 2 ATEX Directive The equipment does not have its own potential ignition source and is not subject to this directive (see "Manufacturer's Declaration" section). When installed, static electricity may arise between the equipment and the connected system. When used in potentially explosive atmospheres, the plant manufacturer or plant operator is responsible for discharging or preventing possible static charge. If it is possible for medium to escape, e.g. through actuating mechanisms or leaks in threaded joints, the plant manufacturer or plant operator must take this into consideration when dividing the area into zones. 7

Storing and transporting the equipment Attention! Equipment can be damaged if stored or transported improperly. Close all openings with the sealing plugs or covers supplied with the equipment or use similar sealing covers. Protect the equipment against moisture and corrosive atmospheres. Please contact the manufacturer if the specified transport and/or storage requirements cannot be met. Storing the equipment Please observe the following items when storing the equipment: Do not store the equipment for more than 12 months. Use the supplied sealing plugs or other suitable seal caps in order to seal off all openings of the equipment. Protect the sealing surfaces and contact areas against mechanical damage. Protect the equipment and all components against hard shocks and impacts. Store the equipment only in closed rooms that meet the following environmental conditions: Air humidity below 50 %, not condensing Indoor air: clean, salt-free and non-corrosive Temperature 5 40 C. Make sure that all these requirements are always met when storing the equipment. Please contact the manufacturer if you cannot comply with the recommended storage conditions. Transporting the equipment Meet the requirements for storage also when transporting the equipment. Prior to transport seal off connections with sealing plugs. If you do not have the sealing plugs supplied with the equipment use appropriate seal caps to seal off the connections. For short distances (only a few metres) you can transport the equipment unpacked. When transporting the equipment over larger distances use the original packaging. If you do not have the original packaging use a box that protects the equipment adequately against corrosion and physical damage. For a short period of time the equipment may be transported even if the temperature is below 0 C, provided that the equipment is completely empty and dry. 8

Mounting and connecting the equipment Preparing installation Take the equipment out of the transport packaging. Check the equipment for transport damage. Contact the manufacturer if you detect any kind of shipping damage. When supplied by the factory, the connections may be sealed off with sealing plugs. Remove sealing plugs before mounting the equipment. Keep the sealing plugs and the packing for further use. DANGER Personnel working on pipes are exposed to safety risks and may suffer severe injuries, poisoning or even loss of life. Make sure that no hot or hazardous fluid is in the equipment or the pipes. Make sure that the pipes upstream and downstream of the equipment are depressurised. Make sure that the installation is switched off and protected against unauthorised or unintended activation. Make sure that the equipment and the pipes have cooled down to room temperatures. Wear protective clothing that is suitable for the fluid and, if necessary, wear protective gear. For more information on suitable protective clothing and safety gear refer to the safety data sheet of the fluid in question. Drain pipes until they are empty. Switch the installation off and protect it against unauthorised or unintended re-activation. Connecting the equipment DANGER Incorrectly connected equipment can cause fatal accidents or severe injuries. Make sure that only qualified skilled personnel connect the equipment to pipes. Make sure that the flow arrow on the equipment body matches the direction of flow in the pipe. Specialist personnel must be highly qualified and fully experienced in making pipe connections for the respective type of end connection. Attention! Equipment will be damaged if the end connections are undersized. Make sure that the connections are strong and rigid enough to support the weight of the equipment and to withstand the forces that occur during operation. Make sure that the pipe system of the plant is clean. Note that equipment without spring can only be installed in vertical pipes with upward flow. Equipment with springs can be installed in any position. To ensure that the pipe is completely drained, the equipment must be installed in a vertical pipe with downward flow. Make sure that the flow arrow on the equipment body matches the desired flow direction. Make sure that the equipment is free from foreign matter. 9

Mount the equipment in the desired installation position. Observe 3 mm space required for servicing. For the installation of the equipment you need clamps. The following component parts to DIN 32676 are required: two clamps (9) two clamp sockets (11) welded to the pipes two suitable gaskets (12) These parts can be obtained directly from the manufacturer. Make sure that both clamp sockets (11) are properly welded to the pipes. Put a gasket (12) between each socket clamp and the body (5). Put the two clamps (9) around the clamp socket and the body. Close the clamps. Tighten the (wing) nuts (10) hand tight. Make sure that the equipment is safely mounted and that all connections are made correctly. 10

Operation During operation you cannot change the settings. After operation DANGER If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment. Only qualified personnel are allowed to perform work on contaminated equipment. Always wear the protective clothing prescribed for contaminated areas when working on the equipment. Make sure that the equipment is completely decontaminated before carrying out any service work. Follow the pertinent instructions for handling the hazardous substances in question. Servicing and repairing the equipment and installing spare parts The equipment does not require any particular maintenance. Examine the equipment at regular intervals and check it for correct operation. If necessary, clean the equipment. No spare parts are available for the equipment. Replace a defective device with a new one. To clean or replace the equipment you have to take it out of the pipeline. For this purpose proceed in reverse order of mounting the equipment. Attention! Frost damage may occur when the installation is shut down. Drain the equipment if ambient temperatures below 0 C (frost) are to be expected. Removing external dirt deposits To remove dirt deposits rinse the equipment with fresh water and wipe it with a clean, lintfree cloth. To remove any persistent residues use a cleaning agent that is suitable for the material and carefully wipe the equipment with a clean, lint-free cloth. 11

Troubleshooting Problem Cause Remedy Loud noise Seat is leaking (equipment does not close properly) The equipment is operating in the Raise the volume flow by increasing the unstable range of the volume flow pump capacity. with the valve disc oscillating. In the case of upward flow remove the fitted spring. Dirty deposits on the seat/valve disc have accumulated. The spring is damaged or worn. The seat or valve disc is damaged. Install a valve of smaller nominal size. Check the condition of the equipment. Clean the gasket faces of the equipment. Replace the equipment if it is damaged. Equipment is leaking fluid. A gasket is worn or damaged. Re-tighten the nuts on the clamps. Check the condition of the gaskets. Replace any defective gasket. If faults occur that are not listed above or cannot be corrected, please contact our Technical Service or authorized agency in your country. 12

Putting the equipment out of operation Removing harmful substances DANGER If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment. Only qualified personnel are allowed to perform work on contaminated equipment. Always wear the protective clothing prescribed for contaminated areas when working on the equipment. Make sure that the equipment is completely decontaminated before carrying out any service work. Follow the pertinent instructions for handling the hazardous substances in question. Qualified personnel must have extensive experience with and a working knowledge of: pertinent rules and regulations concerning handling hazardous substances special regulations for handling the hazardous substances encountered on site using the required personal protective equipment (PPE) and clothing Attention! Environmental damage may be caused by poisonous fluid residues. Before disposing of the equipment make sure that it is clean and free of fluid residues. For the disposal of all materials observe the pertinent legal regulations concerning waste disposal. Remove all residues from the equipment. For the disposal of all residues observe the pertinent legal regulations concerning waste disposal. Removing the equipment DANGER Personnel working on pipes are exposed to safety risks and may suffer severe injuries, poisoning or even loss of life. Make sure that no hot or hazardous fluid is in the equipment or the pipes. Make sure that the pipes upstream and downstream of the equipment are depressurised. Make sure that the installation is switched off and protected against unauthorised or unintended activation. Make sure that the equipment and the pipes have cooled down to room temperatures. Wear protective clothing that is suitable for the fluid and, if necessary, wear protective gear. For more information on suitable protective clothing and safety gear refer to the safety data sheet of the fluid in question. 13

CAUTION Danger of bruising if the equipment falls down. When removing the equipment make sure the it is safely held in place and cannot fall down. Suitable measures are for instance: Equipment that is not too heavy may be supported by a second person. For heavy equipment use suitable lifting equipment of sufficient strength. Detach the end connections of the equipment from the pipes. Put the equipment onto a suitable base. Store the equipment as described in section "Storing the equipment" on page 8. Re-using equipment after storage Observe the following instructions if you want to remove the equipment and use it again somewhere else: Make sure that the equipment is free of any fluid residues. Make sure that all connections are in good condition and leak-free. If necessary re-work welded connections in order to ensure that they are in good working condition. Disposing of the equipment Attention! Environmental damage may be caused by poisonous fluid residues. Before disposing of the equipment make sure that it is clean and free of fluid residues. For the disposal of all materials observe the pertinent legal regulations concerning waste disposal. The equipment is made from the following materials: Component DIN / EN ASME Body, seat and guide ribs Valve disc, spring retainer, spring 1.4408 A351CF8M 1.4571 AISI 316Ti Use the equipment only for its intended purpose and the service conditions for which it was specified. 14

Technical data Dimensions and weights Nominal size [mm] 15 20 25 32 40 50 ["] ½ ¾ 1 1¼ 1½ 2 Overall length A [mm] 23.0 29.5 33.5 38.0 43.0 54.0 Diameter of flange B [mm] 50.5 50.5 64.0 77.5 91.0 106.0 Diameter of groove C [mm] 43.5 43.5 56.5 70.5 83.5 97.0 Inside diameter D [mm] 29.5 29.5 44.0 56.5 66.0 81.0 Weight [kg] 0.2 0.4 0.6 0.75 1.4 2.0 15

Dimensions of pipe end connections Nominal size [mm] 15 20 25 32 40 50 Pipe dimensions to DIN 11850 ["] ½ ¾ 1 1¼ 1½ 2 DN25 1 29.0 1.5 DN32 1 35.0 1.5 DN40 41.0 1.5 DN50 53.0 1.5 DN65 70.0 2.0 DN80 85.0 2.0 Pipe dimensions to ISO 1127 OD 21.3 1 21.3 1.6 Pipe dimensions to ASME BPE OD 26.9 1 26.9 1.6 OD 33.7 33.7 2.0 OD 42.4 1 42.4 2.0 OD 48.3 48.3 2.0 OD 60.3 60.3 2.0 OD 76.1 76.1 2.0 OD 88.9 88.9 2.0 NPS 1" 1 25.4 1.65 NPS 1,5" 38.1 1.65 NPS 2" 50.8 1.65 NPS 2,5" 63.5 1.65 NPS 3" 76.2 1.65 1 To ensure a gap-free connection for these pipe diameters a special socket with transition piece (for inside diameter D) is required. In this case a gasket with inside diameter D must be used. 16

Pressure & temperature ratings T (inlet temperature) [ C] -200 20 200 p (service pressure) [barg] DN 15 DN 50 10.0 10.0 6.0 Max. admissible service pressure (PMA): 10 bar Application limits for valve disk gasket Metal-to-metal DN 15 DN 50 EPDM (FDA approved) FPM (FDA approved) Tmin minimum temperature [ C] -200-40 -25 Tmax maximum temperature [ C] 200 150 200 Application range liquids, gases, steam water, condensate, steam mineral oils, gases, air Opening pressures [mbar] DN Direction of flow Without spring With spring Upwards Upwards Horizontal Downwards 15 2.5 10.0 7.5 5.0 20 2.5 10.0 7.5 5.0 25 2.5 10.0 7.5 5.0 32 3.5 12.0 8.5 5.0 40 4.0 13.0 9.0 5.0 50 4.5 14.0 9.5 5.0 17

Pressure drop chart The curves given in the chart are valid for water at 20 C. To ascertain the pressure drop for other fluids, you have to calculate the equivalent water flowrate. The formula for this is given in the data sheet. The values indicated in the chart are based on spring-loaded valves and horizontal flow. With vertical flow insignificant deviations occur only within the range of partial opening. For more details please contact the manufacturer. A B C D Partial opening / unstable range Full opening / stable range Equivalent water volume flow Vw Pressure drop p 18

Manufacturer's declaration For more information on the Conformity Assessment according to European rules refer to our Declaration of Conformity or our Declaration by Manufacturer. To download the current Declaration of Conformity or Declaration by Manufacturer go to www.gestra.com/documents or contact: GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon +49 421 3503-0 Telefax +49 421 3503-393 E-Mail info@de.gestra.com Web www.gestra.de This declaration is no longer valid if modifications are made to the equipment without consultation with us. 19

Agencies all over the world: www.gestra.de GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon +49 421 3503-0 Telefax +49 421 3503-393 E-Mail info@de.gestra.com Web www.gestra.de 819238-02/04-2018_kx_mm (808905-02) GESTRA AG Bremen Printed in Germany 20