PERME- OX2/230 Oxygen Transmission Rate test system

Similar documents
STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

MODEL GT820 OXYGEN SENSOR

Columbus Instruments

FPG8601 Force Balanced Piston Gauge

AES 28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

12mm Dissolved Oxygen Sensor Care and Use Instructions

Single UNO. Incubator. .com. Main Features: Incubating chamber. of a Multi Well plate. Manual Air/CO 2 mixer. operation.

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

LogIT Dissolved Oxygen Probe

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

InFlow Modular perfusion bioreactor

OxyProbe II Instruction Manual

Traysealer T 100. Tray packaging in the smallest space

Electrochemical Sensor

Electrochemical Sensor

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Armfield Distillation Column Operation Guidelines

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

ME3-HCL Electrochemical sensor

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Experiment B-3 Respiration

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

29 Pressure, Temperature relationship of a gas

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Series Environmental Chambers

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

PRODUCT OVERVIEW Headspace Analysers On-line Analysers Gas Mixers Leak Detectors Permeability Testers

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

HumiSys HF High Flow RH Generator

Oxygen Sensor with Electrode

Porter Analytical & Industrial Products

Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

STERILIZABLE DISSOLVED OXYGEN SENSORS

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Accelerated Corrosion Test Chambers

Oxygen Meter User Manual

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Bold Line Top Stage Incubator

Comparative Study of Oxygen Permeation Through Polymers and Gas Barrier Films

Automatic Permeability Testing: The Challenges and Solutions Author: Alyce Hartvigsen, PBI-Dansensor A/S, Ringsted, Denmark

NEULOG OXYGEN LOGGER SENSOR GUIDE

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Long term stability tests of INO RPC prototypes

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

PRODUCT SHEET. Order probe only as RXPROBE02

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Dissolved Oxygen/Temp Waterproof Tester

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

DISSOLVED OXYGEN SENSOR BT34i

Model 601CV. Mass Flow Controller. Product Features:

PRC CO ² -LASER PRESENTATION

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

AES-28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Hand-held pressure calibrator with integrated pump Model CPH6600

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Nataliya Sharova, Truls Norby NorECs Norwegian Electro Ceramics AS

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

krones Sensometic VP and VPL The intelligent probe filler systems

Mass Flow Controller (MFC) for Gases

ME 8843-Advanced Mechatronics. Project Proposal-Automatic Bike Transmission

KMT Waterjet Systems Inc.

Overview. Front Panel: Keypad and Display

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Pneumatic spool valve islands

Generating Calibration Gas Standards

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Sartorius CCL kg Prototype Mass Comparator

Best Practice Guide, Servomex 2700

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

FAS-W. Features. Applications. Automatic condensation hygrometer

Transmitter CS 21 Operation Manual

Mass Spec will not Autotune

THE PMI ADVANCED PERM POROMETER

Grove - Gas Sensor (O2)

FLUORESCENCE DETERMINATION OF OXYGEN

Dead-weight tester High-pressure version Model CPB3800HP

Design Features. General Description

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Customer Responsibilities

KRONES filling systems for beer Filling of glass containers and cans

3 Flow and Pressure Control

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

APPLICATION NOTE. GC Integrated Permeation Device

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing

NEW: CO2 incubator with sterilizable sensor

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Making OTR Measurements in Bottles using the. BottlePerm Fixture

Transcription:

PERME- OX2/230 Oxygen Transmission Rate test system 1

Principle O2 O2 Test Film N2 N2 To Sensor Mount the sample specimen between the upper and lower cells. The chambers are sealed off. Oxygen (99.999 %) through the upper cell. Nitogen flows through the lowerlower cell. The Oxygen molecule is diffused through the specimen and is carried to the sensor. The Coloumetric sensor measures the quantity of Oxygen that is in the N2 gas. For package test, the some different. The sample is positionned in a attachement where the pur N2 flows inside the pack. Outside can be pure O or ambient air (18% O2) 2

What is a coulometric cell? Cathode Anode H e a t e r O2 measured in N2 stream Solid State Electrolyte O2 + 4 e 2O ² (Cathode) 2O² O2 + 4 e (anode) The electric current produced by the sensor is proportional with the number of atoms flowing to the sensor. The temperature of the sensor is adjusted to 40 C to make it independent to the room temperature. 3

Test Phases 1. Flushing N2 in N2 out At the start of the test you will Flush the upper and flower chamber with pure N2. This is to remove all the traces of O2 that are around both sides of the samples. This time (conditioning time) is very often 4 hours. 4

Test Phases 2. Testing O2 in N2 in O2 in N2 + O2 out Once the chamber has been completely flushed you then can insert pure O2 in the upper chamber and N2 in the lower chamber. The O2 will diffusse through the sample and the test gas will be brought to the sensor. The test time depends on the type of product you are measuring. The test time needs to be set until there is no change in permeability. 5

Structure of the OX 2/230 Modules with 3 test positions Modules interconnected One control PC Water vapour and ox units combined Package testing attachment on top Up to 9 satellite modules 6

3 independent testing cells (Unique feature) 3 testing cells can give 3 results respectively, and can be connected together to enlarge the testing area for higher barrier materials. Each cell can has its own testing mode: Cycle, proportional or independently. Each cell can be started individually. 7

Optional Satellite Modules Up to 9 modules (27 test cells) can be incorporated. All of them are interconnected and one software package is controlling all of them. All the units contain a high precise idenytical sensor. Max. capacity: total 30 positions. Water Vapour and Oxygen unit can be mixed in one testing line. Each module can start to test different samples while other modules or master are running. 8

Parameters Following parameters are controlled N2 flow Set to 10 ml/min Individual set for each cell and zero cell Displayed in software O2 flow Set to 60 ml/min Set with external flowmeter One regulation for all measuring cells Zero Flow Flow regulated to 10 ml/min Displayed in Software 9

O2 humidity Regulated with pressure method (0 %, 100 % and 35-90 %) One regulation for all cells Precision 2% Display of value in software Water reservoir with viewing glass N2 humidity Regulated with pressure method (0 %, 100 % and 35-90 %) One regulation for all cells Precision 2% Display of value in software Water reservoir with viewing glass 10

Temperature testing positions One temperature setting for all cells (15-55 C) Displayed in software Resolution 0,1 % No cooling medium Measuring Cell temperature Temperature controlled to 40 C Displayed in software Resolution 0,1 C 11

Output For gasses Centralized output for the gasses. Colored tubing In Water for visual help 12

3 Chambers - Individual measurements 3 Different samples - No contamination 3 Individual zeroing between measurements 13

Test Chamber 1 Test Chamber 2 Test Chamber 3 Every Cycle Ref. Chamber Chamber 1 Ref Chamber Chamber 2 Ref Chamber Ref.Chamb er Sensor Correct Zero Individual results Flexibiity 14

Powerful Software Convenient and sophisticated Windows based software can show the testing parameters for each cell from all the master modules. Main interface General info for each cell is clearly shown. The actual status of each cell is written and graphical indicated. 15

Really Powerful Software Multiple modes of standard, proportional, non-proportional, cycle, and manual extend the testing range, make the parameter selection and set-up easier, and allow a flexible operation. Quick-start interface 16

Really Powerful Software Test control interface Parameters for each cell/sample can be set up easily. 17

Really Powerful Software Cell status interface Status of each cell can be shown independently and clearly. For each measuring points you can see the values for Temp, Flow, Permeability 18

Really Powerful Software Diagnostic interface Diagnostic interface can be used to check the status of main functional parts, including: sensor s life time, how usage, temperature, humidity, flow, as well as the satellite modules ID. 19

Really Powerful Software Single test Report interface Report for each cell can be displayed and printed respectively. 20

Really Powerful Software Callog interface 21

Package Testing Chamber Testing temperature of package test can be controlled precisely by Package Environmental Chamber. Temperature control range is from 5 to 55 centigrade. Temp diaplayed with 0.1 C. Connected with the module. Positioned on top of the module 22

Package Testing Each Package can have own set-up Lens Testing PET preform Testing Cap testing Tray Testing Bottle Testing 23

Technical Data 24