Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Similar documents
Checking a Breathing System

Selecting and Connecting Breathing Systems

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Recommendations on Checking Anaesthesia Delivery Systems

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Keeping anaesthetic pollution to minimum in theatre environment

Breathing Systems. Professor Khalid Bashir

Canine Endotracheal Intubation

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

o An experienced and trained assistant is available to help you with induction.

DPA 02 TM Diamedica Portable Anaesthesia System INSTRUCTIONS AND USER GUIDE

Monitoring, Ventilation & Capnography

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Day-to-day management of Tracheostomies & Laryngectomies

Medical Instruments in the Developing World

Breathing Process: Inhalation

Practical considerations in anaesthetising exotic species. By Keith Simpson BVSc MRCVS AMIIE(Electronics).

Anesthesia monitoring

Guidelines on Monitoring in Anaesthesia

Flow meter. bellow vaporizer. APL valve. Scavenging system

Learning objectives. First Response Learning Module 2 Based on ILCOR and ANZCOR 2016

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

First Response Learning Module 2 Based on ILCOR and ANZCOR Victorian Newborn Resuscitation Project Updated March 2018

VENTILATORS PURPOSE OBJECTIVES

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites

Page: 1 of 6 Responsible faculty: (Signature/Date)

Mechanical Ventilation

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Operating & troubleshooting a self inflating bag. Victorian Newborn Resuscitation Project Updated February 2012

STANDARDIZED PROCEDURE NEONATAL INTUBATION (Neonatal)

RESUSCITATION. If baby very floppy and heart rate slow, assist breathing immediately. If baby not breathing adequately by 90 sec, assist breathing

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Circulation and Respiration: Vital Signs Student Version

International Journal of Science, Environment and Technology, Vol. 5, No 5, 2016,

Oxygen Dialflow Meter. Instructions for Use

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

Micro Dial-Flowmeter. Instructions for Use

Nitrous oxide Quiz 2017 Answers

SERVICE KITS AND CALIBRATION NOTES

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

II. Set up the monitor

Understanding Tracheostomy Care

Anesthesia. Midmark Animal Health Products

Section 2.9 Decannulation

Laryngeal Mask Airway (LMA) Indications and Use for the NH EMT-Intermediate and Paramedic

NARKOVET ANAESTHETIC UNIT

Rev. B. Operating Instructions

Patient Information for the: Humanitarian Device for use in the Control of Air Leaks

ACUC ۰ ROUTINE PROCEDURE

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

Clinical Skills. Administering Oxygen

Endotracheal Suctioning: In Line ETT

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN

Equipment and supplies - pediatric intensive care service.

Anaesthetic infrastructure and supplies

Breathing systems. Non-rebreathing system using a unidirectional valve pair. Non-rebreathing systems

Operation and Maintenance of the EPV200 Portable Ventilator

Understanding Tracheostomy Care for your Child

Anesthesia Machine Intro

Oxygen Dialflow Meter. Instructions for Use

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Draeger Fabius GS Pre-Use Check

The centerpiece of a comprehensive anaesthesia workstation

QED-100 Clinical Brief

ANESTHESIA VAPORIZER SERVICE RECOMMENDATIONS

VAPOMATIC ANESTHETIC VAPORIZER

BASIC PHYSICS APPLIED TO ANAESTHESIOLOGY

Complex Care Hub Manual: Oxygen Therapy

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Summary of Cardiac Anesthesia Technician Responsibilities

The development of this workbook was undertaken by trainers and developers within SAMPLE

M5400 Operators Manual

Anes Machine Use and Pre-use Check - CA1 focus

PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT

Using the Lifebox oximeter in the neonatal unit. Tutorial 1 the basics

የIትዮዽያ የደረጃዎች ኤጀንሲ ETHIOPIAN STANDARDS AGENCY ES DRAFT UPLOAD REQUEST FORM FOR PUBLIC COMMENTS

Airway Control and Ventilation... 1 Adult... 1 Pediatric... 1 Neonate... 2 Jones & Bartlett Learning, LLC NOT FOR SALE OR DISTRIBUTION

INSTRUCTIONS FOR USE KING LT 2

Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

Figure 1. A schematic diagram of the human respiratory system.

Instructions/Procedure for Use of the Speaking Valve

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Section 14: Equipment failure

KimVent * Closed Suction System Solutions for the Home Care Pediatric Patient. Instructions for Use. Ballard* Trach Care* Technology

Figure 5. Nasal mask in place

Nitrous Oxide Sedation

SPEMS SKILLS PROFICIENCY CRITERIA Paramedic

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

Breathing Devices. Chapter 8 KNOWLEDGE OBJECTIVES SKILL OBJECTIVES. 6. List four precautions to take when using oxygen.

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

B.L.S احیای پایھ کودکان American Heart Association

Anesthesia Machines. Inhaled Anesthetic Agents

APNOEA AND PRE-OXYGENATION

Medical Ventilators. Ryan Sanford Daniel Tajik

Auditing the non-emergency use of a fan or oxygen to relieve breathlessness at rest: Background form

Transcription:

Proceedings of the World Small Animal Sydney, Australia 2007 Hosted by: Next WSAVA Congress

NURSES SETTING UP FOR ANAESTHESIA HOW TO PLAN FOR A SAFE ANAESTHETIC Sandra Forysth, BVSc DipACVA Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Private Bag 11222, Palmerston North New Zealand. S.F.Forsyth@massey.ac.nz Anaesthesia usually proceeds smoothly but when things go wrong they can be disastrous so it makes sense to try and minimise the potential for these problems to occur. This means that all anaesthetic and monitoring equipment should be set up and checked, that all potential problems are considered and that the patient is supported and monitored appropriately during the anaesthetic and peri-anaesthetic period. Pre-anaesthetic Monitoring Sedated patients don t often show unusual reactions but after administration of sedative drugs they should be placed in an area where they can be frequently monitored. The area should be warm as animals can become cold due to lack of movement and reduced metabolic rate. Hypothermia after acepromazine is especially common because the drug induced peripheral vasodilation further enhances heat loss. Hypothermia reduces drug metabolism, lowers requirements for subsequent drugs, may induce bradycardia and slows recovery. In some patients usual sedative doses may result in marked depression so that respiration is compromised. This is most commonly seen in older animals, brachycephalics breeds, (bulldogs, pugs, Pekinese etc) and in those with pre-existing respiratory or cardiac disease. Respiratory depression raises carbon dioxide which in itself may not compromise the patient unless it becomes very high but hypoventilation can cause hypoxia in a patient that is breathing room air. Blood and tissue hypoxia can result in cell death, organ dysfunction and possibly death of the patient. Using the correct agents at an appropriate dose doesn t always ensure freedom from complications so sedated patients need to be monitored. Setting up the Equipment We usually choose an anaesthetic circuit (ie circle or T-piece) based on the weight of the patient but patients of the same weight have different capacities to cope with the resistance in a circle system. Go ahead and choose a circuit based on weight or size but watch the animal for the first 5-10 minutes after connection to the machine and intermittently throughout the anaesthetic period to ensure that it is coping. For example in our practice, animals under 5 kg routinely go on a T-piece and those over, on a circle. However, occasionally dogs weighing 5-10 kg appear to expend a huge amount of effort in moving their chest wall for very little movement of the reservoir bag. If we are sure that there is no obstruction in the ET tube or kinking of the tubing then it usually means that there is too much resistance in the anaesthetic circuit and that the animal needs a T-piece rather than a circle. Changing the system usually Proceedings results in of a the much WSAVA reduced Congress, ventilatory Sydney, effort. Australia 2007

Check for Leaks Before inducing anaesthesia the machine must be checked to make sure that it is functioning properly. This means ensuring that there is enough agent (halothane or isoflurane) and oxygen to last for the duration of the procedure. Thymol, a preservative in halothane can build up within the vaporiser and make it appear as though there is sufficient agent present when in fact there is not. Vaporizers need regular servicing (about once per year) to ensure that they are accurate (ie put out the concentration of halothane or isoflurane that is indicated on the dial) and to drain and clean them to prevent thymol build up. Thymol can also make the vaporiser sticky so that it becomes difficult to rotate the gauge when changing concentration. Isoflurane doesn t contain a preservative so this is not a problem with these vaporisers. A full oxygen cylinder contains hundreds of litres of oxygen (depending on cylinder size) and the gauge needle sits on the red area (supposedly, meaning nearly empty) when there is about ¼ of the oxygen remaining. So if we run the oxygen at 1 L/min then when the oxygen cylinder moves to the red area there is still over a hundred litres of oxygen present ie at least 1½ hours of oxygen if running at 1 l/min. It is not necessary to change the oxygen cylinder as soon as it reaches the red area after all the oxygen supply company will happily take back a ¼ cylinder and charge for a full one. Although we don t need to change the cylinder at this point we should still ensure that there will be sufficient oxygen to last the duration of the procedure. The anaesthetic machine should be checked to ensure that there are no leaks in the system as there is nothing more frustrating or potentially dangerous than attempting to ventilate an apnoeic patient and finding too many leaks in the anaesthetic system. To check the machine, the pop-off valve is closed (pressure relief valve), the patient port occluded with a thumb or finger and the reservoir bag inflated until no wrinkles are present. The oxygen is turned off and the bag observed for reappearance of wrinkles. A deflating reservoir bag indicates that there is at least one leak in the system. Common sites for leaks include the reservoir bag (inhalation agents perish rubber), at joints especially around the soda lime canister and within tubing of the Y-piece. Ideally a pressure check like this should be carried prior to every anaesthetic but should be done at least once a day or after changing the soda lime. Once a day a high pressure system check should also be carried out. This is done by occluding the fresh gas flow rate port and turning the oxygen flow meter to 1L/min. After a short of time you should observe the flow meter falling due to the build up in pressure. If the bobbin or ball does not fall a leak in the backbar should be considered. Endotracheal Tubes Setting up also includes estimating the size of ET tube needed by the patient and then getting one or two tubes either side of this. This array of tubes is necessary so that if intubation is difficult, a small tube is available for easy placement when an airway needs to be secured rapidly. Some animals

especially the brachycephalics breeds of dogs (bulldogs, Pekinese, pugs etc) frequently have tracheal hypoplasia ie a smaller trachea than expected and so they need an ET tube that is very much smaller than anticipated. So, in these breeds it pays to have a very wide range of tubes available at the time of intubation. Larger tubes should be available because occasionally the patient will have a wider trachea than anticipated. It is necessary to use the correct sized tube, otherwise the cuff is excessively inflate to prevent leakage which exerts pressure on a localized area of the trachea and can potentially cause tracheal necrosis. This is a greater problem with the red rubber tubes because the cuffs are low volume, high pressure although some of the clear tubes may have a similar effect. The cuff on every tube selected should be checked by inflating and gently squeezing it. The reason for squeezing the cuff is that you may detect a slow leak that won t be detected if the cuff is simply left to deflate naturally. Induction is a time when large amounts of anaesthetic agent are given to overcome the extremely strong protective airway reflexes. Consequently, cardiovascular and respiratory depression can be profound and apnoea is extremely common. Having ET tubes close at hand is a necessity so that rapid intubation can be achieved if necessary. Support and Monitoring Equipment Support and monitoring equipment should also be organised prior to induction. If the patient is to receive fluids then these should be warmed to about 38 o C and an administration set attached. Appropriate sized catheters should be available and the tape necessary to keep them in place. If the animal is to receive fluids for hours to days post-operatively then a sterile preparation of the catheter site should be carried out. It is not sufficient to simply wipe the site with alcohol or methylated spirits for long term catheter placement. The catheter should also be taped or glued firmly in place to prevent movement as this can result in thrombophlebitis necessitating premature removal of the catheter. Heating pads should be pre-warmed so that they are ready for the patient. Monitoring equipment such as dopplers, pulse oximeters, Apalerts, ECGs etc should be checked to see that they are working properly prior to use. Complicated cases It pays to be a pessimist when setting up for the anaesthesia of a complicated case or critical patient. This is because if all or most complications are considered and contingencies set up to manage them, they rarely occur. In our practice we make a table of the emergency drugs that may be needed for a particular patient and calculate the volume of drug that would need to be drawn up. By doing this and having the doses available there is no need to do various calculations in the heat of a critical moment Drugs for 10 kg Mg/kg Mg/ml Volume (ml)

Atropine 0.01 0.65 0.15 Adrenaline 0.01 1 0.1 Lignocaine 1 20 0.5 Conclusion Setting up for an anaesthetic involves not just getting the equipment out but checking that it is functioning properly so that in the case of an emergency everything is ready to go.