Dry Plant Measurement Information

Similar documents
Minutes of the Meeting. BE IT RESOLVED, Affirmed American National, Peter McHenry Ackermann, claimed his private property, known as a vote.

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements

MEASUREMENTS LAND LINEAR MEASURE... 2 LAND AREA MEASURE... 3 VOLUME MEASURE WEIGHT or MASS... 5 MEASURES OF ANGLES AND ARCS...

Estimating Highway Maintenance Work 2008

PART 3 MODULE 6 GEOMETRY: UNITS OF GEOMETRIC MEASURE

The Right Tool for the Job

c) How much will Carrie pay for flooring her room that is 16ft by 20ft if flooring costs $12.95 / square yd? Area of room: 16 20

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS LIST

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Q = C v P S

Chapter 5 Rate, Ratio and Proportion

TECHNICAL DATA. Q = C v P S

Convert Units of Length

Section 2.3: Conversions Factors and Unit Rates

Application Worksheet

Full Range Pressure Compensating Variable Flow Control

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Math 15 Test 3 Review Section Change 4.5 yards to inches. Round your answer to the nearest inch. (1 yd = 3 ft, 1 ft = 12 in)

Medium Heavy Vehicle Safety and Foundation 1

Customary Units of Length

DESIGN DATA. Dry 105a. September 5, 2008

Unit Rates and Conversions

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Data Sheet Issue A

Jenny Castillo Tammy Muller Brandi Stemple. Intro to Physical Science Fall 2010 Dianne Phillips

Lesson 12.1 Skills Practice

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

USEFUL RELATIONSHIPS

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Model 1800 PFM Series Regulator. Technical Bulletin

A.M. The time between 12:00 midnight and 12:00 noon. Houghton Mifflin Co. 1 Grade 4 Unit 5

Model: AT-1000 L.P.G. FREEZE VALVE

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Choosing the right miniature instrument and control valve is a snap

Gas Hydraulic Valve Operator

CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG

GAS SUPPLY DESIGN GUIDE

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

Model: AT-1000 L.P.G. FREEZE VALVE

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Full Service Warehouse

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

Mathematics in Contemporary Society Chapter 9

Powers Controls RC 195 Multiple Input Receiver- Controller

Types ACE95 and ACE95Sr Tank Blanketing Valves

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Type ACE95jr Tank Blanketing Valve

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

SIZING AND CAPACITIES OF GAS PIPING

The Hoffman Specialty Series 2000 consists of main

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Type R622 Pressure Reducing Regulator

Instruction Manual VCG-6

Full Internal Relief Valves Instruction Manual

Year 9 notes part 5. Contents

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Before we begin, let us recall some important information about the metric measuring system.

ENGINEERING DATA. Engineering Data

Build Your Own Flamethrower Step-by-step Manual

T208VR Series Tank Blanketing Vacuum Regulator

Quick Reference Technical Data

Limited quantities of compressed gases.

MEGR-1912 Instruction Manual

HORIZONTAL BLADDER TANK

LP-10 LP-GAS SERVICEMAN'S HANDBOOK

UNIT PLAN. Grade Level: 3 Unit #: 4-2 Measurement: Length, Volume, Mass, & Equivalencies

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

SIZING AND CAPACITIES OF GAS PIPING

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

LESSON 9 - PRACTICE PROBLEMS

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Data Sheet Issue A

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Series 100 Slam Shut Valve. Technical Bulletin

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Storage Systems and Accessories

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

Global Connection Solutions for Local Industrial Fluid Applications

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

CAPITAL CONTROLS SERIES NXT3000

shutoff valves 900 Series psig Manual Shutoff Valves

Pneumatic Reservoir Analysis Work Sheet

Natural Gas Conversion Kit

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Transcription:

Dry Plant Measurement Information Fertilizer - Information Pages DRY PLANT MEASUREMENT Basic Formula: Pounds of Product = Cubic Feet x Product Weight Area A: 14' x 28' x width = cubic feet x product weight Area B: 10' x 6' = 60 square feet 2 = 30 2 x width = cubic feet x product weight Area C: 18' x 6' = 108 square feet 2 = 54 2 x width = cubic feet x product weight Partial Bin Measurement: 10' x 4' = 40 square feet 2 = 20 2 x width = cubic feet x product weight 433

Commonly Used Formulas Pressure in PSI of a Column of Water = Height of Column in Feet x.434 Wheel RPM = 1056 x MPH Circumference Gallons per Acre = ( GPM x 5940 ) (GPA) ( MPH x Swath in Inches ) Gallons per Minute = GPA x MPH x Swath in Inches (GPM) 5940 Capacity of a Round Tank in Gallons = Diameters in Inches Squared x Length in Inches x.0034 Gallons per Foot of Depth = Diameter in Feet Squared x 5.875 Gallons per Foot of Depth = Diameter in Inches Squared x.0408 Diameter of Circle = Circumference x.31831 Circumference of Circle = Diameter x 3.1416 Area of Circle = Square of Diameter x.7854 Capacity of a Rectangular Tank in Gallons = Length in Inches x Width in Inches x Height in Inches 231 Fertilizer - Information Pages PRESSURE METRIC MULTIPLY CONVERSION UNITS BY TO OBTAIN Atmospheres 14.70 Pounds per Square Inch Atmospheres 407.14 Inches Water Inches of Mercury 1.133 Feet of Water Inches of Mercury 0.4912 Pounds per Square Inch Inches of Water 0.0735 Inches of Mercury Inches of Water 5.204 Pounds per Square Foot Inches of Water 0.0361 Pounds per Square Inch Inches of Water 0.5781 Pounds per Square Inch Pounds per Square Inch 0.06804 Atmospheres Pounds per Square Inch 2.036 Inches of Mercury Pounds per Square Inch 2.307 Feet of Water Pounds per Square Inch 27.67 Inches of Water Atmospheres 1.0332 Kilograms per Square Centimeter Grams per Square Centimeter 0.0142 Pounds per Square Inch Kilograms per Square Centimeter 14.22 Pounds per Square Inch Kilograms per Square Meter 0.2048 Pounds per Square Foot Pounds per Square Inch 0.7031 Kilograms per Square Centimeter LENGTH VOLUME METRIC MISCELLANEOUS Centimeters Feet Feet Feet Inches Inches Kilometer Meters Meters Meters Miles (statute) Miles (nautical) Yards Yards 0.3937 304.8 30.48 0.3048 25.40 2.540 0.6214 39.37 3.281 1.094 1609.0 1853.0 91.44 0.9144 Inches Millimeters Centimeters Meters Millimeters Centimeters Miles Inches Feet Yards Meters Meters Centimeters Meters Cubic Feet 1728 Cubic Inches Cubic Feet 7.4805 Gallons (US) Gallons 0.1337 Cubic Feet Gallons 231.0 Cubic Inches Gallons (US) 0.83267 Gallons (Imperial) Gallons (Imperial) 1.20095 Gallons (US) Cubic Centimeter 0.06103 Cubic Inch Cubic Feet 28.316 Liters Gallons (US) 3.785 Liters Liters 0.03531 Cubic Feet Liters 0.2642 Gallons (US) Liters 1.057 Quarts (US) Liters 2.113 Pints (US) Pints (US) 0.4732 Liters BTU 0.252 Calories Calories 3.968 BTU Decitherm 10,000 BTU Kilogram 2.205 Pounds Kilowatt Hour 3412 BTU Ounces 28.35 Grams Pounds 453.5924 Grams Pounds 0.4536 Kilograms Therm 100,000 BTU 27 Cubic Feet = 1 Cubic Yard FORMULA FOR ACTUAL POUNDS OF NH3 (NITROGEN) PER HOUR Use the Formula: Lbs. Nitrogen x Swath Feet x MPH x.1212 = Nitrogen in One Hour Example: Lbs. of Nitrogen per Acre = 100 Swath Width in Feet = 30 Tractor Speed (MPH) = 5 100 x 30 x 5 x.1212 = 1818 lbs. per hour This will be the dial setting at 100# tank pressure in a normal fitting arrangement (12 feet hose x hose valve x 1" QDC x 3' of 1" hose). Basic Formula - Pounds of Product: 1 Acre = 16.5' x 2640' (1/2 mile) TRAILER/SPREADER CAPACITY Cubic Feet x Product Weight (to find what equipment will haul) Cubic Feet x Weight of Product 2000 (ton) Example: 38 1/2' Trailer = 1323 Cubic Feet (heaped) 1323 x 46# (Urea) = 60858 2000 (ton) = 30.42 Ton Capacity 434

Measurement Conversion Factors GENERAL One Acre One Hectare One Gallon per Acre One Mile One Gallon One Gallon 43,560 Square Feet or 0.405 Hectares 2.471 Acres 9.35 Liters per Hectare One Pound per Square Inch (PSI) 0.070 kg/cm 2 One Pound per Square Inch (PSI) One Pound One Inch AREA MEASURE 144 Square Inches 9 Square Feet 30 1/4 Square Yards 160 Square Rods 1 Acre 640 Acres 1 Square Mile 1 Rod LINEAR MEASURE 12 Inches 3 Feet 5 1/2 Feet 1 Foot 1 Yard 1 Rod 5,280 Feet or 1610 Meters or 1.61 Kilometers 128 Fluid Ounces or 8 Pints or 4 Quarts 3.79 Liters or 0.83 Imperial Gallons 6.895 kpa (Kilopascal) 454 Kilogram 2.54 Centimeters 1 Square Foot 1 Square Yard 1 Square Rod 1 Acre 43,560 Square Feet 1 Square Mile 1 Section (of Land) 16.5 Feet DRY MEASURE 1/2 Quart 2 Pints 8 Quarts 1 Pint 1 Quart 1 Peck 40 Rods 1 Furlong 4 Pecks 1 Bushels 8 Furlongs 1 Mile 1 Mile 5,280 Feet = 320 Rods LIQUID MEASURE 1/16 Pint 4 Ounces 1 Ounce 1 Gill 105 Quarts CUBIC MEASURE 1,728 Cubic Inches 27 Cubic Feet 1 Barrel 1 Cubic Foot 1 Cubic Yard 4 Gills 1 Pint = 16 Ounces 128 Cubic Feet (4 x 4 x 8 ) 1 Cord (Wood) 2 Pints 1 Quart = 32 Ounces 231 Cubic Inches 1 Gallon 4 Quarts 1 Gallon 31 1/2 Gallons 1 Barrel 31 1/2 Gallons 126 Quarts HEAD 1 Pound per Square Inch (PSI) 1 Foot of Water 1 Inch of Mercury 2,150.4 Cubic Inches 2.31 Feet of Water 2.04 Inch Mercury 0.433 Pounds per Square Inch 0.885 Inch Mercury 1.132 Foot of Water 1 Kilogram per Square centimeter 14.22 Pounds per Square Inch 1 Atmosphere (at Sea Level) 1 Meter of Water WEIGHT OF SOLUTION 7.0 Pounds per Gallon 8.0 Pounds per Gallon 8.34 Pounds per Gallon Water 9.0 Pounds per Gallon 10.0 Pounds per Gallon 11.0 Pounds per Gallon 12.0 Pounds per Gallon 14.0 Pounds per Gallon 16.0 Pounds per Gallon 18.0 Pounds per Gallon 20.0 Pounds per Gallon Imperial Gallon 14.7 Pounds per Square Inch 33.9 Feet of Water 10.35 Meters of Water 3.28 Feet of Water SPECIFIC GRAVITY.84.96 1.00 1.08 1.20 1.32 1.44 1.68 1.92 2.16 2.40 1.20 USA Gallons 1 Bushel CONVERSION FACTORS 1.09 1.02 1.00.96.91.87.83.77.72.68.65 VOLUME 1 US Gallon 1 Imperial Gallon 1 Cubic Foot 1 Liter 1 Cubic Meter 1 Acre Foot 1 Acre Inch 1 Barrel (Oil) METRIC CONVERSION LINEAR MEASURE 1 Centimeter 1 Inch 1 Decimeter 1 Foot 1 Meter 1 Yard 1 Dekameter 1 Rod 1 Kilometer 1 Mile SQUARE MEASURE 1 Square Centimeter 1 Square Inch 1 Square Decimeter 1 Square Foot 1 Square Meter 1 Square Yard 1 Acre 1 Square Rod 1 Hectare 1 Acre 1 Square Kilometer 1 Square Mile MEASURE OF VOLUME 1 Cubic Centimeter 1 Cubic Inch 1 Cubic Decimeter 1 Cubic Foot 1 Cubic Yard 1 Stere 1 Cord 1 Liter 1 Quart Dry 1 Quart Liquid 1 Dekaliter 1 Gallon 1 Peck 1 Hektoliter 1 Bushel WEIGHTS 1 Gram 1 Ounce 1 Kilogram 1 Pound 1 Metric Ton 1 English Ton 231 Cubic Inches 0.137 Cubic Feet 3.785 Liters.00379 Cubic Meters 0.833 Imperial Gallon 1.2 US Gallons 277.274 Cubic Inches 1728 Cubic Inches 7.481 US Gallons 0.0283 Cubic Meter 0.2642 US Gallon 35.314 Cubic Feet 264.2 US Gallons 43,560 Cubic Feet 325,829 US Gallons 3,630 Cubic Feet 27,100 US Gallons 42 US Gallons 0.3937 Inches 2.54 Centimeters 3.937 Inches or 0.328 Feet 3.048 Decimeters 39.37 Inches or 1.0936 Yards 0.9144 Meter 1.9884 Rods 0.5029 Dekameter 0.62137 Mile 1.6093 Kilometers 0.1550 Square Inch 6.452 Square Centimeters 0.1076 Square Foot 9.2903 Square Decimeter 1.196 Yards 0.8361 Square Meter 160 Square Rods 0.00625 Acre 2.47 Acres 0.4047 Hectare 0.386 Square Mile 2.59 Square Kilometers 0.061 Cubic Inch 16.39 Cubic Centimeters 0.0353 Cubic Foot 28.317 Cubic Decimeters 0.7646 Cubic Meter 0.2759 Cord 3.624 Steres 0.908 Quart Dry or 1.0567 Quarts Liquid 1.101 Liters 0.9463 Liter 2.6417 Gallons or 1.135 Pecks 0.3785 Dekaliter 0.881 Dekaliter 2.8375 Bushels 0.3525 Hektoliter 0.03527 Ounce 28.35 Grams 2.2046 Pounds 0.4536 Kilogram 0.98421 English Ton 1.016 Metric Ton Fertilizer - Information Pages 435

NH3 CFM Chart and Properties Fertilizer - Information Pages 436

FEI, Inc. Valves Quality Steel Tank Corporation Tank Specifications Emergency Shutoff NH3 Hardened Threads The 2" FNPT threads on the nipple portion are of hardened stainless steel to reduce wear from repeated use. Excess Flow Valve With a poppet design similar to the internal valve series, an excess flow spring is available. The spring has a closing flow of 200 GPM propane at 13 psid. Dual Service With all internal parts either stainless steel or plated steel, the valve can be used on NH3 service as well as LP gas. Marshall Excelsior Safety Stroke ME551 is constructed with durable, corrosion resistant stainless steel and is a perfect fit for the Fisher N550 series and is designed to fit all ESV sizes. It features the Airstroke actuator by Firestone with smooth acting cam and heavy return spring allowing complete opening for full flow. It is easy to install without modification with a temperature range of -60º F. to 250º F. and recommended operating pressure of 20-25 psig. DESCRIPTION VALVE-EMER SHUTOFF 1-1/4" FPT 50 GPM SNAPPY JOE VALVE-EMER SHUTOFF 2" FPT 75 GPM SNAPPY JOE VALVE-EMER SHUTOFF 3" FPT 195 GPM SNAPPY JOE RELEASE-CABLE FOR N550 ESV VALVE 50' LONG KIT-AIR CYL N550 VALVE CLOSE ONLY KIT-AIR CYL OPEN & CLOSE SPRING-EXTERNAL CLOSING FOR N550 ESV VALVES VALVE-EMER SHUTOFF 2" FPT X 3-1/4" MPT RR TANK CARS ACTUATOR-EMER SHUTOFF N550 ESV VALVES LIST PRICE $881.74 $1,941.20 $2,677.69 $505.74 $372.65 $977.96 $214.91 $3,554.30 $619.17 Remote Shutdown Safely shuts down all valves from 300 feet away in any direction. Works with electric or pneumatic ESV and internal valves. Apply to existing or pneumatic systems with minimal installation. Works with any pneumatic brand actuator eliminating unreliable cable pull systems. Operate up to 15 RSD-E1 transmitters per E-Box. Transmitters are programmable for multiple facility sites. RSD E-Box is ready to go with 110 Volts in and 12 Volts out and includes one RSD-E1 transmitter. PART NUMBER RSD-E1 RSD-E-BOX RSD-SVH-AA DESCRIPTION TRANSMITTER-REMOTE RECEIVER-STORAGE REMOTE SHUTDOWN MODULE-PNEUMATIC SOLENOID VALV LIST PRICE $384.06 $4,089.53 $674.62 129 437 Fertilizer - NH3 Pages Fertilizer - Information PART NUMBER LP-N551-10 LP-N551-16 LP-N551-24 LP-P164B LP-P327D LP-P539 LP-P551 LP-N562-26 LP-ME551

Trinity Containers NH3 Tank Specifications Fertilizer - Information Pages 438

hes NOTES

hes NOTES

hes NOTES

hes NOTES

FEI, Inc. Valves Emergency Shutoff NH3 Snappy Joe Emergency Shutoff Valves for Bulk Plants - Snappy Joe type N551 emergency shutoff valves are designed for in-line installations, usually near a bulkhead. The valves provide a means of shutting off gas in the event of a hose rupture or piping break at the transfer area to avoid a large scale loss of LP gas or NH3. The valves can be manually opened and closed at the installed location or closed remotely by either cable or air. A remote operating actuator is also available. High Flow Capacity The main poppet moves completely out of the flow stream for extremely low restriction to flow. Fertilizer - NH3 Operational Ease Moving the operating lever to the vertical position opens the valve, making it simple to tell if the unit is open or closed. A pilot valve in the poppet opens as the lever is moved upward to pressurize the hose. Once equalized, the poppet moves quickly to the open position. The valve is closed by simply pushing the lever down without first having to trip a latch. The operating lever is easily reached from across a bulkhead. All sizes look similar and operate exactly the same, an important point in an emergency situation. Type P164B a release assembly that uses 50 feet (15 meters) of cable housing which does not require elaborate guiding like uncovered cables. Pneumatic Operation Remote pneumatic closure is available with type P327D release. Depending upon valve inlet pressure, a minimum supply pressure of 30 to 70 psig (2,1 to 4,8 bar) on the P327D allows the valve to be latched in the open position with manual closure possible at the valve. Loss of supply pressure to the cylinder permits the ESV to close. Air, nitrogen or CO2 can be used for the cylinder supply source. Maximum inlet pressure to the cylinder is 125 psig (8,6 bar). Operating temperature range -40º F to 212º F (-40º C to 100º C). Type 539 pneumatic actuator permits opening and closing of the N550 Snappy Joe emergency shutoff valves (ESVs) both at the valve with the use of a pneumatic four way valve and from a remote location. The actuator opens the valve when pressure is applied. Minimum pressure is 20 psig (1,4 bar) and maximum pressure is 30 psig (2,1 bar). Upon loss of pressure, the N550 closes, assisted by the spring in the pneumatic actuator. Snappy Joe Emergency Shutoff Valves for Railroad Tank Cars - Snappy Joe type N562 Emergency Shut off Valves (ESVs) are designed for railcar protection and attach to the shutoff valves on railroad tank cars (refer to installation drawing). Typically three N562s are used two on the liquid lines and one on the vapor line. NFPA 58 regulations call for ESV protection on both sides of the transfer hose or piping. Pneumatically operated, the valve is opened and closed by means of a standard quick disconnect coupling (furnished). Approximately 20 to 60 psig (1,4 to 4,1 bar) is needed to open the valve, depending upon tank car pressure. 128

FEI FAX ORDER FORM FAX 1-800-313-3299 1% Fax Order Discount DATE: FEI ORDER NO.: BILL TO: SHIP TO: ZIP CODE: ZIP CODE: CUSTOMER NAME: SHIP TO NAME: ADDRESS: ADDRESS: TOWN: TOWN: CONTACT PERSON: PURCHASE ORDER # PHONE: SHIP VIA: COMMENTS: UPS GROUND CPU SPEEDEE PARCEL POST MOTOR FREIGHT OTHER QUANTITY PART NUMBER DESCRIPTION BILLINGS, MT ( ) HASTINGS, NE ( ) VALLEY CITY, ND ( ) YAKIMA, WA ( )

THE PRODUCTS, KNOWLEDGE, AND EXPERIENCE TO SERVE YOUR NEEDS WITH THE BRANDS YOU KNOW AND TRUST Liquid Handling Products WCCO Belting, Inc. NEW LOCATION - HASTINGS, NEBRASKA Phone: (800) 437-9702 Fax: (800) 313-3299