ME3-HCL Electrochemical sensor

Similar documents
Electrochemical Sensor

Electrochemical Sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Nemoto Sensor Engineering Company Ltd

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Nemoto Sensor Engineering Company Ltd

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Phosgene Sensor. Sensoric COCl2 3E 1

MD61 Thermal Conductor Gas Sensor

an ISO9001 company TECHNICAL INFORMATION FOR SK-25F Technical Information for Figaro Oxygen Sensor SK-25F

MODEL GT820 OXYGEN SENSOR

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Ozone. Sensoric O3 3E 1

Operation manual Oxygen sensor

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

12/07/2016 Grove Gas Sensor(O₂) Wiki

Grove - Gas Sensor (O2)

Transmitter CS 21 Operation Manual

O3 3E 1 F Gas Sensor Module

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Instruction and Maintenance Manual

Dissolved Oxygen Guide

Columbus Instruments

GENERAL INFORMATION FOR TGS SENSORS. Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

Instruction and Maintenance Manual

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

Sensoric 4-20 ma Transmitter Board Operation Manual

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

MANUAL KPS Pressure Control Valve

75 Allen Street Lexington, MA Minute Model & Pricing Overview Guide

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Technical Data Sheet MF010-O-LC

Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω

M iniature Amplified Pressure Sensors

an ISO9001 company TECHNICAL INFORMATION FOR TGS5141 Technical Information for Carbon Monoxide Sensors

HTD series digital differential pressure sensors

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Application Note AN-107

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Amplified Middle Pressure Sensors

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Oxygen Flue Gas Analyzer BA 2000

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

an ISO9001/14001 company

PC12K Flush Diaphragm Pressure Sensor with Clamp

Specifications of Oxygen Sensor Module V-8344A

Transmitter CS 21 Operation Manual

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

GasSense NDIR User Manual

Grove - Gas Sensor(MQ9)

LFE OEM TCD - Thermal Conductivity Detector

PC10 Piezoresistive Silicon Pressure Sensor

DISSOLVED OXYGEN SENSOR BT34i

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

LUMAZOTE T ECHNICAL BRO CHU RE

Standard Operating Procedure for H 2 S and SO 2 Converter

Applications Note: Use of "pentane equivalent" calibration gas mixtures

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

Coriolis Mass Flow Meter

MS52XX-C&T SMD Pressure Sensor

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Best Practice Guide, Servomex 2700

Heavy Duty Dissolved Oxygen Meter

Manual of SF6 Comprehensive Tester

an ISO9001 company TECHNICAL INFORMATION FOR TGS5042 Technical Information for Carbon Monoxide Sensors

PERME- OX2/230 Oxygen Transmission Rate test system

Digital deadweight tester Model CPD8500

SPECIFICATION FOR APPROVAL THE PIEZOELECTRIC SOUNDER

SX150A. Features. Typical Applications. Description

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Operation and Maintenance Manual

COSMO INSTRUMENTS CO., LTD.

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Operating Instructions

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

MS54XX Miniature SMD Pressure Sensor

PRELIMINARY DATASHEET

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

OxiQuant S. Operating Instructions

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Digital dead-weight tester Model CPD8500

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

PRODUCT CONFORMITY CERTIFICATE

Electro-Pneumatic Converter YT-940 SERIES

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Oxygen Sensor Operating Principle Guide

Installation and Operation Manual

Transcription:

ME3-HCL Electrochemical sensor Manual (Model:ME3-HCL) Zhengzhou Winsen Electronics Technology Co., Ltd

ME3-HCL gas sensor ME3-HCL electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current. 1. Features * Low consumption * High precision * High sensitivity * Wide linear range * Good anti-interference ability * Excellent repeatability and stability 2. Application Widely used in industrial and environmental protection fields 3. Technical Parameter 4. External dimension Detection gas Measurement Range Max detecting concentration Sensitivity Resolution ratio Response time(t 90 ) Bias voltage Load resistance(recommend) Repeatability Stability(/month) Output Linearity Zero drift(-20 ~40 ) Storage temperature Storage Humidity HCL 0~20ppm 200ppm (0.8±0.4)µA/ppm 0.1ppm 30S 0mV 10Ω <2 % output value <2 % linear 0.2ppm -20 ~50 15 % ~90 % RH(no condensation) Pressure range Standard atmosphere ±10% Anticipated using life 2 years(in air)

5.Characterization Features of Sensitivity, response and resuming Output signal/μa Data graph of concentration linearity features Output signal/μa Time /s Concentration/ ppm Zero point changing upon Variable Temperature Output signal/ppm Output upon variable temperature Output signal/20 6.Basic circuit Temperature/ Temperature/

7. Anti-Interference: ME3-HCL sensor also responds to other gases besides target gas. Below are the response characteristics of interferential gases Gas Concentration ME3-HCl CO 200ppm <2ppm NO2 5ppm -5ppm CL2 10ppm <-10ppm CH4 400ppm 0ppm NO 35ppm 0ppm H2 500ppm <2ppm HCN 10ppm <0.2ppm C2H4 100ppm <6ppm H2S 15ppm 29ppm 8.Application Notes: Sensor shall Avoid organic solvent, coatings, medicine, oil and high concentration gases; All ME Sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment, otherwise, it will damage the function of sensor; All ME sensors shall not be applied in corrosive gas environment, or the sensor will be damaged; Please test the sensitivity of gas sensors in clean atmosphere; Sensors Shall be avoided to face the gas, which flow directly from front side; To avoid to bend and break of pins;

Blowhole of the sensor should not be blocked and polluted, which will cause the sensitivity decrease; Excessive impact or vibration should be avoided; Do not use the sensor when the shell is damaged; It takes some time for the sensor to return to normal state After applied in high concentration gas; Do not take apart the sensor, otherwise electrolyte leakage can cause sensor damage; Working electrode and reference electrode of the sensor shall be in short circuit when stored.; To preheat over 48hs before using and soldering forbidden; Note: To keep continual product development, we reserve right to change design features without prior notice! Zhengzhou Winsen Electronics Technology Co., Ltd Add.: NO.299 Jin Suo Road, National Hi-Tech Zone, Zhengzhou, 450001 China Tel.: 0086-371-67169097 /67169670 Fax:0371-60932988 E-mail:sales@winsensor.com