Adiabatic Calorimetry

Similar documents
Relief System Sizing for Runaway Chemical Reactions: A Simple Comprehensive Approach

Relief Systems. 11/6/ Fall

Absorption - The process of contacting a vapor and gas stream with an absorbing liquid to remove specific materials from the gas stream.

WHITE PAPER TESTING GUIDE FOR MANAGEMENT OF FLASH FIRES, EXPLOSIONS, AND RUNAWAY REACTIONS

I. CHEM. E. SYMPOSIUM SERIES NO. 85

PRESSURE RELIEF VENTING SYSTEMS EXAMPLES OF GOOD AND BAD PRACTICE

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

Application Note AN-107

Accelerating Rate Calorimeter

Material Safety Data Sheet

PRACTICAL EXPERIENCE IN CARRYING OUT NON-ELECTRICAL EQUIPMENT IGNITION RISK ASSESSMENTS

The Right to Know Laws and Assessment of Risks & Hazards 2004

STARBURST, AIRBURST & FALLING STARS SAFETY DATA SHEET SECTION 1 PRODUCT IDENTIFICATION

Runaway Chemical Reaction at Corden Pharmachem, Cork

FLASH PAPER, COTTON, CORD, STRING & MATERIAL SAFETY DATA SHEET SECTION 1 PRODUCT IDENTIFICATION

CONSUMER SAFETY DATA SHEET BISSELL INCORPORATED PRINT DATE: May 25, 2010

SAFETY DATA SHEET SDS DATE: 1/15/2016 Sperm Viability Stain

Chemicals that will cause mutations to germ cells of humans that can be transmitted to Mutagenicity

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

LARGE-SCALE EVALUATION OF VENT-SIZING METHODOLOGY FOR VAPOUR-PRESSURE SYSTEMS

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR (g) and GHS Rev 03.

SAFETY DATA SHEET (800) (800) Category 2 Category 2A

SAFETY DATA SHEET (800)

MATERIAL SAFETY DATA SHEET Validation Beads for ique Screener PLUS

Material Safety Data Sheet

High Pressure Chem-SCAN Operating Manual

Material Safety Data Sheet L-Phenylalanine

Material Safety Data Sheet According to ISO/DIS Data sheet No. MSDS 0089USA Issue No 1 Date:

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Material safety data sheet

Dangerous Substances and Explosive Atmosphere regulations 2002(DSEAR): Guidance to risk assessment

SAFETY DATA SHEET (800) (800)

MATERIAL SAFETY DATA SHEET

FANTASTIK SCRUBBING BUBBLES HEAVY DUTY LEMON POWER ALL PURPOSE CLEANER

Safety Data Sheet ZYMOX SHAMPOO. ADDRESS (NUMBER, STREET, CITY, STATE, ZIP): 710 Vandustrial Dr. Westmont, IL 60559

Safety data sheet according to 1907/2006/EC, Article 31

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet According to 91/155 EEC

Material Safety Data Sheet. Drum Cartridge

SC Johnson Professional Defoamer

April 21, Print MSDS Sheet. Technical Resources Products Services Business Units & Executive Team What's New Literature How To Find Us

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET according to the Global Harmonized System

Drum Cartridge. Issuing Date Revision Date Version 1

ONONDAGA COUNTY HEALTH DEPARTMENT Annual Training Hazard Communication Right to Know

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Innovative Pressure Testing Equipment

MATERIAL SAFETY DATA SHEET according to the Global Harmonized System

Material Safety Data Sheet acc. to ISO/DIS 11014

MATERIAL SAFETY DATA SHEET DATE PREPARED: January 2001

: 634C Liquid Silicone 1 lb. Jar

Material Safety Data Sheet

Material Safety Data Sheet acc. to ISO 11014

Safety Data Sheet. 0.9% Saline Solution. Section 1: Chemical Product and Company Identification Contact Information: Growcells.com, INC.

Material Safety Data Sheet acc. to ISO/DIS 11014

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

ZER904 Zero In Wasp Nest Killer Foam 300ml

Sika Technique Primer 206 G+P

Safety Data Sheet acc. to OSHA HCS

M a t e r i a l S a f e t y D a t a S h e e t

MATERIAL SAFETY DATA SHEET according to the Hazard Communication Standard (29 CFR )

MATERIAL SAFETY DATA SHEET

ZER962 ZERO IN ANT, COCKROACH & CRAWLING INSECT KILLER SPRAY (HSE: 9034) ZER966 ZERO IN COCKROACH KILLER SPRAY 300ml (HSE: 9075)

SC Johnson Professional Windex Glass Cleaner with Ammonia-D

3-Mix-Processed Glass Abrasive SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET according to the Global Harmonized System (and with all of the information required by the CPR)

SAFETY DATA SHEET. Date of Preparation: 06/17/2014 SDS #: MSDS

Material Safety Data Sheet Product name: CBC-Normal Human RBC Hematology Controls and Calibrators Printing date 6/29/2010 Revised Date 07/12/2006

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR (g), Rev and GHS Rev 03.

MATERIAL SAFETY DATA SHEET

Safety Data Sheet Copper Compound

Substance key: BBG7080 REVISION DATE: 00/00/0000 Version Print Date: 11/29/2005. Somerville, NJ Telephone No.:

Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR (g), Rev and GHS Rev 03.

Safety Data Sheet Lyden Oil Company

SAFETY DATA SHEET (800) (800) Category 2 Category 2A

Material Safety Data Sheet acc. to ISO 11014

NFPA 1124, Code for the Manufacture, Transportation, Storage, and Retail Sales of Fireworks and pyrotechnic Articles, 2006 edition.

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET FILE NO.: AVL-ECCII

MATERIAL SAFETY DATA SHEET according to the Hazard Communication Standard (29 CFR )

KIWI EXPRESS SHINE INSTANT SHINE SPONGE - BLACK

SAFETY DATA SHEET. CU-8120 Enzyme & bacteria digestive powder. None. (800) (800) Category 5 Category 3 Category 2B

SCJP Windex Cleaner Non-Ammoniated

Material Safety Data Sheet

Material Safety Data Sheet acc. to ISO/DIS 11014

SECTION I COMPANY IDENTIFICATION

SAFETY DATA SHEET. In Accordance with 1272/2008/EC, 29 CFR 1910

HEPES Buffer Solution (1M)

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY

SAFETY DATA SHEET INTERNATIONAL FLAVORS & FRAGRANCES

SAFETY DATA SHEET. Great Lakes Orthodontics 200 Cooper Ave Tonawanda, NY CHEMTREC:

Learning from Dangerous Occurrences in the Chemical Industries

1. Identification of the substance/preparation and the company/undertaking

Material Safety Data Sheet acc. to ISO/DIS 11014

Transcription:

Adiabatic Calorimetry For DIERS Vent Sizing Data, Advanced Thermal Stability Analysis and Runaway Reaction Characterization, the assessment of runaway reactions and thermal decompositions is a critical part of the safe operation of a chemical process or drying operation. Obtaining laboratory data that can be directly scaled-up to the production size of most plant operations requires that both the heat losses and thermal inertia (phi factor) of the plant be replicated. Adiabatic calorimetry is designed to provide data that can be used for consequence assessment, emergency relief system design (using DIERS methods) and accurate thermal stability assessment.

Industrial services When is Adiabatic Calorimetry Required? Adiabatic calorimetry is required when data is sought under low heat loss/low thermal inertia conditions. This may be when a direct simulation of a process deviation requires characterization or when thermal stability screening tests indicate a narrow margin between normal processing conditions and the onset conditions of a hazardous event (e.g. an undesirable decomposition). Sizing an emergency relief vent for a runaway exothermic reac-tion demands adiabatic test data and is the primary application of the technique. However, adiabatic calorimetry is also used for other forms of consequence analysis and designing safety systems to protect against a runaway process. ADC II What is The Data Used For? Adiabatic calorimetry data is typically required to characterize: the onset temperature of thermal instability of a process mixture or material under sensitive conditions (which requires provision of a negligible safety margin) the consequence of a process deviation (or deviations) under pseudo-plant scale thermal conditions the rates of runaway reactions the data required for emergency relief system design calculations using best practice methodologies (i.e. DIERS) for runaway reactions the nature of flow from the venting of a runaway reaction the time to maximum rate of a runaway reaction from inception, or the definition of the temperature from which it takes a reaction 24 hours to reach its peak rate (often referred to as the TD24) What is Adiabatic Calorimetry? As the name implies, adiabatic calorimetry involves the quantifi-cation of energy release from a reaction or decomposition under zero heat exchange (adiabatic) conditions. Large scale process vessels are typified by very low heat losses to the environment and a low thermal inertia (i.e. the reaction vessel absorbs little of the heat generated by an exothermic process). In adiabatic calorimetry, reactions are allowed to proceed under zero heat loss conditions and, in most cases are designed to have a very low thermal inertia. The data obtained can represent a direct simulation of the large scale process vessel.

What methods of Adiabatic Calorimetry are available? Methods for adiabatic calorimetry generally fall into two categories: pressure resistant adiabatic calorimetry (such as Accelerating Rate Calorimetry (ARC) and Adiabatic Pressure Dewar Calorimetry (ADC II)), or pressure compensated adia-batic calorimetry (such as the Vent Sizing Package (VSP II)). Whilst fundamentally operating in a similar manner and producing comparable data, each method has its advantages and disadvantages. Accelerating Rate Calorimeter (or ARC), is typically used for determining the onset temperature of decomposition for unstable materials and to provide kinetic data for energetic processes which cannot be obtained in less robust calorimeters of this type. The ARC is a fully adiabatic calorimeter which has a moderate thermal inertia. This type of test is not normally directly scalable but data can be mathematically corrected to account for the thermal inertia. The ARC has a very high pressure and temperature capability (typically up to 500 C and 200 barg) and is an ideal technique for advanced thermal stability testing or testing of highly ener-getic compounds which may prove dangerous in larger scale calorimeters. Since the ARC is not easily agitated, its applica-tion for reaction simulation is limited. Similarly, the small scale nature of the bomb makes reliable semi-batch addition studies prohibitively difficult. Adiabatic Pressure Dewar Calorimeter system (or ADCII) has a lower pressure capability (typically to 40 barg) than the ARC but the thermal inertia is much lower and reactions can be performed under heat loss and thermal inertia conditions which are directly applicable up to 25 m3 (without any mathematical adjustment). Compared with other adiabatic calorimeters, the ADC II system offers several distinct advantages: exceptional thermal stability and heat retention (even at elevated temperatures and pressures) mechanical agitation (via anchor or impeller) with torque and speed measurement semi-batch additions can be made readily and in a well controlled manner the potential to rapidly change from temperature controlled conditions (using internal cooling coils) to adiabatic operation, whilst maintaining a low thermal inertia the study of runaway reaction mitigation strategies. For example, assessing the efficacy of reaction inhibition as a basis for arres-ting incipient runaway reactions by chemical inhibitor injection. The instrument is extremely versatile and is readily tailored to most applications. The larger test cell (1 litre) readily facilitates controlled semi-batch additions of liquids and gases whilst main-taining low phi factors down to 1.05 in most configurations. The apparatus can be used for differentiating between gas generating and vapor pressure controlled reactions through the conduct of runaway tempering trials. It can also be used to establish flow regime characteristics (single or two-phase) and fluid flowability/viscosity via discharge trials. Simulation of runaway reaction dynamics under fire engulfment conditions is simple to undertake with the ADC II. Vent Sizing Package 2 (VSP2 ) The Vent Sizing Package, was originally developed during the DIERS project in the mid-1980 s to collect data for vent sizing calculations on runaway exothermic reactions and decomposi-tions, and later commercialized as the VSP2. Unlike the Adiabatic Dewar and ARC systems, which use thicker wall test cells to withstand high pressures, the 120 cm3 VSP2 test cells are thin walled with lower phi factor. The apparatus is capable of studying reactions

to high pressures by using pressure balancing, whereby the lightweight test cell is placed in a high pressure chamber where the containment pressure is regulated close to that inside the cell. Maintaining a low differential pressure permits reactions to be studied up to 100 barg and 140 barg, in case of the standard and the high pressure VSP2 systems respectively. The test is fully adiabatic and operates with very low phi factors typically down to 1.05. The apparatus is agitated either through magnetic or me-chanical stirrers and reactions can be conducted under standard sealed cell conditions or to examine the tempering or flow regime characteristics of reaction runaways. The study of semi-batch additions is possible using pressure injection systems. This unit is one of the most well-known adiabatic calorimeters across the world and is particularly popular in the USA for the study of runaway reactions. What methods of Adiabatic Calorimetry do you need? Each adiabatic calorimetry method has its relative merits for specific applications. For exceptional thermal stability performance, for example studying the thermal instability of a mixture over a prolonged period, the Adiabatic Dewar technique excels. For the study of highly energetic materials and mixtures, the ARC is a safer yet equally reliable tool. For studying reaction systems that generate high pressures by gas generation or use of volatile solvents, the VSP II has an excellent peak pressure capability combined with good agitation performance. In having access to all three calorimeters within our laboratories, it is possible to select the most appropriate technique for the specific application resulting in the highest quality data for safety studies or protection system design. What can we provide? Our accredited and fully equipped laboratories in N.America, Europe, and Asia Pacific and consulting staff are available to assist you to select the most appropriate test (or tests) for any specific application. Once we understand your needs and specific plant situation, we will tailor an experimental program to your material or reaction. We ensure that unnecessary tests are not performed. We do not just provide data we always provide a complete technical report which outlines the rationale behind each test, the safety margins that should be applied (if any) and concludes with recommendations regarding safe processing conditions (made by one of our Process Safety Specialists). Our customer support service is second to none. Our consulting team can readily utilize the experimental data to calculate emergency relief system requirements (for example using methods developed by the DIERS project) or to assist in the specification of a safety system and basis of safety for a plant operation.

Directory of services With the recent expansion of services, it is useful to review what is now available. The list below is an overview of the specialist areas where we are able to provide expert advice. Consulting Capability Organization & compliance Safety Management Regulatory Compliance Support Technical Specialist Areas Hazard Assessment and Risk Analysis Explosion Prevention & Protection Modelling Chemical Reactions Energetic Materials Electrostatics Fire Prevention & Protection Occupational Health & Safety Reliability Protection & Equipment Inert Gas Protection Instrumentation and Equipment Pressure Vessels Project Engineering Incidents & Support Incident Investigation Litigation Support Insurance Risk Environment Testing Capabilities Process Safety Special Testing - Laboratory Testing - Field Tests ( Large Scale) Explosion (Deflagration) - Dust - Gas / Vapor - Hybrid - Aerosol Thermal Stability / Chemistry - Chemical Reaction Hazards - Powder Thermal Stability - Chemical Process Optimization Explosion (Detonation) - Propellants / Pyrotechnics Explosives / Fire - Mattress / Furniture - Custom Tests - Full Scale Simulation Electrostatics Process Problems Applications Safety Test Regulatory UN / DoT Transportation Classification Packaging Labelling (CPL) MSDS Notification Registration Evaluation REACH Training Capabilities Organisation & Compliance Process Safety Management Process Safety Culture COSHH OSHA Dust Explosion Prep Training ATEX 137 / DSEAR Environment / Integrated Management Systems Process Hazards Analysis Technical Specialist Dust Explosion Prevention & Protection Control of Static Electricity Gas & Vapor Explosions Chemical Reaction Hazards/ Thermal Stability Hazardous Area Classification HAZOP Protection & Equipment IEC 61508/11 SIL Levels ATEX 94/9 Hazardous / Electrical Area Classification Vent Design (Explosion, Pressure, Reactor Protection) Instrument / Equipment Supplies Process Safety Laboratory Equipment Special Equipment Large Scale Explosion High Pressure / Temperature Custom Design Explosions Dust / Gas / Vapor Explosion Testing Thermal Stability Chemistry Reaction Hazard Screen Tools Adiabatic Calorimeter Powder Thermal Stability Fire I-Cal (Fire Calorimeter) Electrostatic Equipment (JCI) Laboratory Equipment Electric Field Meter / Volt Meter Charge Relaxation Time Charge Measurement Field Test Equipment Lightening Warning Adverse Conditions Equipment Regulatory (Systems) Physical or Chemical Properties Measurement About Us Safety Consulting Engineers, Inc. (SCE) is an approved test agency, recognized by the United States Department of Transportation (DOT) to test and examine explosives or potentially explosive substances and recommend the proper shipping classification. We have the skills and credentials to assist you in all your test and analysis needs for energetic materials or processes. For more information regarding process hazards analysis, system safety, material characterization, DOT and other regulatory compliance, and any associated testing, please contact us at 847-925-8100 or email us at sceinc@sceinc.com. 2016 DEKRA Insight. All rights reserved. All trademarks are owned by DEKRA Insight, reg. U.S. Pat. & Tm. Off.; reg. OHIM and other countries as listed on our website.